Tải bản đầy đủ (.pdf) (30 trang)

Bsi bs en 01159 3 2003

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (321.4 KB, 30 trang )

BS EN
1159-3:2003

BRITISH STANDARD

Advanced technical
ceramics — Ceramic
composites,
thermophysical
properties —
Part 3: Determination of specific
heat capacity
--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

The European Standard EN 1159-3:2003 has the status of a
British Standard

ICS 81.060.20

12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.


BS EN 1159-3:2003


National foreword
This British Standard is the official English language version of
EN 1159-3:2003. It supersedes DD ENV 1159-3:1995 which is withdrawn.
The UK participation in its preparation was entrusted to Technical Committee
RPI/13, Advanced technical ceramics, which has the responsibility to:


aid enquirers to understand the text;



present to the responsible international/European committee any
enquiries on the interpretation, or proposals for change, and keep the
UK interests informed;



monitor related international and European developments and
promulgate them in the UK.

A list of organizations represented on this committee can be obtained on
request to its secretary.
Cross-references
The British Standards which implement international or European
publications referred to in this document may be found in the BSI Catalogue
under the section entitled “International Standards Correspondence Index”, or
by using the “Search” facility of the BSI Electronic Catalogue or of British
Standards Online.
This publication does not purport to include all the necessary provisions of a
contract. Users are responsible for its correct application.

Compliance with a British Standard does not of itself confer immunity
from legal obligations.

This British Standard was
published under the authority
of the Standards Policy and
Strategy Committee on
22 April 2003

Summary of pages
This document comprises a front cover, an inside front cover, the EN title page,
pages 2 to 26, an inside back cover and a back cover.
The BSI copyright date displayed in this document indicates when the
document was last issued.

Amendments issued since publication
Amd. No.

Date

Comments

© BSI 22 April 2003

ISBN 0 580 41605 4
--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy


Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.


EUROPEAN STANDARD

EN 1159-3

NORME EUROPÉENNE
EUROPÄISCHE NORM

April 2003

ICS 81.060.20

Supersedes ENV 1159-3:1995

English version

Advanced technical ceramics - Ceramic composites,
thermophysical properties - Part 3: Determination of specific
heat capacity
Céramiques techniques avancées - Composites
céramiques, propriétés thermophysiques - Partie 3:
Détermination de la capacité thermique spécifique

Hochleistungskeramik - Keramische Verbundwerkstoffe,
thermophisikalische Eigenschaften - Teil 3: Bestimmung
der spezifischen Wärmekapazität


This European Standard was approved by CEN on 2 January 2003.
--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official
versions.
CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United
Kingdom.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG

Management Centre: rue de Stassart, 36

© 2003 CEN

All rights of exploitation in any form and by any means reserved
worldwide for CEN national Members.

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

B-1050 Brussels


Ref. No. EN 1159-3:2003 E

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.


EN 1159-3:2003 (E)

Contents
page
Foreword......................................................................................................................................................................3
Scope ..............................................................................................................................................................4

2

Normative references ....................................................................................................................................4

3

Terms and definitions....................................................................................................................................4

4
4.1
4.2
4.3
4.4
4.5
4.5.1
4.5.2

4.5.3
4.6
4.6.1
4.6.2
4.6.3
4.7
4.7.1
4.7.2

Method A - Drop calorimetry.........................................................................................................................5
Principle ..........................................................................................................................................................5
Apparatus .......................................................................................................................................................5
Standard reference materials .......................................................................................................................5
Test specimens ..............................................................................................................................................5
Calibration of calorimeter .............................................................................................................................5
General............................................................................................................................................................5
Electrical Calibration .....................................................................................................................................6
Calibration using standard reference material ...........................................................................................6
Test procedures .............................................................................................................................................6
Test without a crucible ..................................................................................................................................6
Test with a crucible........................................................................................................................................6
Description of test .........................................................................................................................................7
Calculations....................................................................................................................................................7
General............................................................................................................................................................7
Determination of the calorimetric calibration factor ..................................................................................8

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

1


4.7.3

Determination of mean specific heat capacity C p ....................................................................................8

5
5.1
5.1.1
5.1.2
5.1.3
5.2
5.2.1
5.3
5.4
5.5
5.6
5.6.1
5.6.2
5.6.3
5.7
5.7.1
5.7.2

Method B - Differential scanning calorimetry .............................................................................................9
Principle ..........................................................................................................................................................9
General............................................................................................................................................................9
Stepwise heating method..............................................................................................................................9
Continuous heating method .........................................................................................................................9
Apparatus .....................................................................................................................................................10
Differential scanning calorimeter ...............................................................................................................10
Standard reference materials, SRM ...........................................................................................................10

Test specimens ............................................................................................................................................10
Temperature calibration ..............................................................................................................................10
Test procedure for the determination of Cp ..............................................................................................11
General..........................................................................................................................................................11
Method 1: Measurements requiring the knowledge of the K factor........................................................11
Method 2: Measurements requiring the use of a reference standard material (SRM) ..........................12
Calculation of results ..................................................................................................................................13
Method requiring the knowledge of the K factor ......................................................................................13
Method using an SRM .................................................................................................................................14

6

Test report ....................................................................................................................................................16

Annex A (normative) Drop calorimetry - Determination of the calibration factor using standard
reference material ........................................................................................................................................19
Annex B (informative) Standard reference material...............................................................................................20
Annex C (informative) Materials for calorimeter calibrations ...............................................................................25
Bibliography ..............................................................................................................................................................26

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

2

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.



EN 1159-3:2003 (E)

Foreword

This document (EN 1159-3:2003) has been prepared by Technical Committee CEN/TC 184 "Advanced technical
ceramics", the secretariat of which is held by BSI.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by October 2003, and conflicting national standards shall be withdrawn at the latest
by October 2003.
This document supersedes ENV 1159-3:1995.
EN 1159 Advanced technical ceramics – Ceramic composites, thermophysical properties consists of three parts:


Part 1: Determination of thermal expansion



Part 2: Determination of thermal diffusivity



Part 3: Determination of specific heat capacity

www.bzfxw.com

Annex A is normative. Annexes B and C are informative.

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following

countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal,
Slovakia, Spain, Sweden, Switzerland and the United Kingdom.

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

3


EN 1159-3:2003 (E)

1

Scope

This part of EN 1159 describes two methods for the determination of the specific heat capacity of ceramic matrix
composites with continuous reinforcements (1D, 2D, 3D).
Unidirectional (1D), bi-directional (2D) and tridirectional (XD, with 2 < x ≤ 3).
The two methods are:


method A: drop calorimetry;




method B: differential scanning calorimetry.

They are applicable from ambient temperature up to a maximum temperature depending on the method: method A
may be used up to 2 250 K, while method B is limited to 1 900 K.
NOTE
Method A is limited to the determination of an average value of the specific heat capacity over a given temperature
range and can give a larger spread of results.

2

Normative references

This European Standard incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For
dated references, subsequent amendments to or revisions of any of these publications apply to this European
Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the
publication referred to applies (including amendments).

www.bzfxw.com

ENV 13233:1998, Advanced technical ceramics – Ceramic composites – Notations and symbols.

3

Terms and definitions

For the purposes of this European Standard, the following definitions and those given in ENV 13233:1998 apply.
3.1
specific heat capacity, Cp
amount of heat required to raise the temperature of a mass unit of material by 1 K at constant temperature and

pressure
Cp =

1 dQ
m dT

where
Q

is the heat required for a test-piece of mass m

3.2
mean specific heat capacity, C p
amount of heat required to raise the temperature of a mass unit of a material from temperature T1 to temperature
T2 at a constant pressure, divided by the temperature range (T2 – T1) expressed in K
3.3
representative volume element (R.V.E.)
the minimum volume which is representative of the material considered
Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

4

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

EN 60584-1, Thermocouples - Part 1: Reference tables (IEC 60584-1:1995).



EN 1159-3:2003 (E)

4

Method A - Drop calorimetry

4.1 Principle
A test piece is dropped from a conditioning chamber at a constant temperature T1 to another chamber at a constant
temperature T2.
The mean specific heat capacity is determined from the measured amount of heat required to maintain the
temperature constant in the second chamber. Transfer of the test piece shall be done under conditions as close as
possible to adiabatic conditions.

4.2 Apparatus
4.2.1 Drop calorimeter, there are several types of drop calorimeters. They include one (or more) conditioning
chambers and measuring chambers which can be operated under controlled atmosphere and which are all
equipped with a temperature control system which allows a temperature stability of less than 1 K.

Heat transfer by radiation during the drop shall be avoided as far as possible.

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

The conditioning chamber shall have a homogeneous temperature zone size greater than the test specimen size.
The measuring chamber shall have a homogeneous temperature zone of a sufficient length to accept several
specimens and a sufficient thermal inertia to limit the temperature disturbance, due to the drop.

4.2.2 Balance, with an accuracy of 0,1 mg for test pieces over 10 mg and an accuracy of 0,01 mg for test pieces
below 10 mg.


www.bzfxw.com

4.2.3 Temperature detectors, thermocouples in accordance to EN 60584-1 shall be used for the measurement
of temperature up to 1 920 K.
For higher temperature, infrared detectors or any other suitable device may be used.
4.2.4

Data acquisition system, the sampling period during the test shall be less than 0,5 s.

4.3 Standard reference materials
Standard reference materials which can be used for calibration purposes are listed in annex B.

4.4 Test specimens
The test specimens shall be representative of the material.
NOTE
This criterion is generally met by test specimens containing the maximum number of representative volume
elements, compatible with the volume of the crucible, if this number is less than five, several solutions are possible:

a) the test specimens should have an exact number of representative volume elements;
b) the material should be ground to powder and a specimen taken from this powder. However this solution will
lead to results which may differ from results obtained on solid test pieces and should be used only if no other
solution is possible;
c) the material should be cut into specimens and a number of similar test specimens should be tested and an
average value determined.

4.5 Calibration of calorimeter
4.5.1

General


Calibration of calorimeters, may be done according to two different methods. The first consists in dissipating a
known amount of thermal power using a calibrated resistor introduced in the second chamber of the calorimeter. In
Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

5


EN 1159-3:2003 (E)

the second method a reference specimen with known specific heat capacity is dropped according to the procedure
described in section 4.6.
4.5.2

Electrical Calibration

The calibration factor is the ratio of a known amount of thermal power dissipated in the resistor to the steady state
calorimetric output signal and is measured at temperature T2.
NOTE 1

The method using power dissipation in a resistor is limited to 1 350 K.

NOTE 2
chamber.


This method can only be used if the sensitivity of the calorimeter is not affected by the filling of the measuring

4.5.3

Calibration using standard reference material

This calibration is called “drop calibration”. A specimen made from a standard reference material with a known
specific heat capacity is dropped according to the test procedures described in section 4.6. (See annex B for
standard reference material). This allows determination of the calibration factor (see annex A).

4.6 Test procedures
--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

NOTE
The avoidance of interaction between the test specimen and the calorimetric conditioning and measuring chambers
can require the use of a sealed crucible.

4.6.1

4.6.1.1

Test without a crucible
Test with drop calibration

www.bzfxw.com

The test without a crucible and with drop calibration is done in the following order:
R, T, R, T, R, T, R
with
R = test of standard reference material, and;

T = test of test specimen.
Carry out each test as described in 4.6.3.
4.6.1.2

Test with electrical calibration

The test without a crucible and with calibration using power dissipation in a resistor is done in the following order:


calibration of calorimeter;



test on three test specimens.

Carry out each test as described in 4.6.3.
4.6.2
4.6.2.1

Test with a crucible
General

The mass of all empty crucibles used for the test shall not differ by more than 5 %.
4.6.2.2

Test with drop calibration

The test with a crucible and with drop calibration is carried out in the following order:
Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy


6

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.


EN 1159-3:2003 (E)

C, C + R, C + T, C, C + R, C + T, C, C + R, C + T, C
with
C

is the test with the empty crucible;

C + R = test of crucible plus standard reference material;
C + T = test of crucible plus test specimen.
Carry out each test as described in 4.6.3.
4.6.2.3

Test with electrical calibration

The test with a crucible and with calibration using power dissipation in a resistor is done in the following order:


calibration of calorimeter;




carry out the following sequence:
C, C + T, C, C + T, C, C + T, C

with
C

is the test with the empty crucible;

C + T = test with crucible plus test specimen.
Carry out each test as described in 4.6.3.
4.6.3

Description of test

www.bzfxw.com

The test piece (test specimen, standard material or empty crucible) and reference material shall be dried at
(110 ± 5) °C until the difference in weight of two successive weighings is lower than 0,2 mg:


measure the mass when a crucible is not used with an accuracy of ± 0,1 mg or ± 0,1 % whichever is the
smaller;



when a crucible is used, measure the mass of each assembly dropped, (empty crucible, crucible and standard
reference material, crucible and test specimen);




place the test piece (test specimen, standard material or empty crucible) in the conditioning chamber at
temperature T1 and wait for a sufficient period (in the order of 15 min), to reach thermal equilibrium of the test
piece with its environment. Measure T1 and T2 start recording the calorimetric signal before the test piece is
dropped. Drop the test piece. Stop the record when the steady state output signal is reached.

4.7 Calculations
4.7.1

General

The change in heat Q corresponding to the drop of the test piece is related to the area A under the calorimetric
output signal by the following equation.
Q = K⋅A
where
K

is the calorimeter calibration factor.

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

7



EN 1159-3:2003 (E)

4.7.2

Determination of the calorimetric calibration factor

4.7.2.1

Electrical calibration (see annex A)

K =

heat dissipated
= H
area under the calorimetric output signal
A

4.7.2.2

With standard reference material

See annex B.
4.7.3

Determination of mean specific heat capacity C p

The mean specific heat capacity is determined using the following formula:
C p (T1 , T2 ) =

1 Qi (T1 , T2 )

mi (T2 - T1 )

where
T1

is the initial temperature at which test pieces, are conditioned;

T2

is the calorimeter temperature;

Qi (T1,T2)

is the heat variation between T1 and T2;

mi

is the mass of the test piece, determined by weighing;

www.bzfxw.com

C p (T1 , T2 ) mean specific heat capacity between T1 and T2.

The subscript i has a different meaning depending on the type of test piece:


i = c for an empty crucible;




i = t for a test piece;



i = t + c for a test piece and crucible.

without crucible
Cpt =

K • At


mt  T2 − T1 





C pt =

K (Ac + t - Ac )
m t (T2 - T1 )

with
At

is the value of integration of calorimetric output signal of test specimen;

Ac


is the value of integration of calorimetric output signal of crucible;

Ac+t

is the value of integration of calorimetric output signal of test specimen plus crucible.

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

8

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

with crucible


EN 1159-3:2003 (E)

5

Method B - Differential scanning calorimetry

5.1 Principle
5.1.1

General


The method consists in measuring the difference in power needed to raise the temperature of the test specimen in
its crucible and of an empty identical crucible using the same heating programme which may be stepwise heating
or continuous heating.
Stepwise heating allows only the determination of the mean specific heat capacity C p (T1, T2 ) over a temperature
range (T1, T2) while continuous heating allows to determine the specific heat capacity Cp at a given temperature.
5.1.2

Stepwise heating method

The mean specific heat capacity C p (T1, T2 ) is measured in a temperature interval defined by two isothermal levels
T1 and T2. The heat QE which is necessary to change the temperature from T1 to T2 is determined by integrating
the thermal power PE with respect to time. The corresponding heat QE is:
QE =

∫o PE dt = (mt Cp (T1 ,T2 ) + Cc + C o ) (T2 - T1 )
t

where
mt

is the mass of the test specimen;

C p (T1, T2 )

is the mean specific heat capacity of the test specimen;

Co

is the heat capacity of the calorimeter;


Cc

is the heat capacity of the crucible.

Another experiment for the determination of the base line is performed using an identical imposed heating
sequence with the empty crucible. The corresponding heat QB is given by:
QB =

∫o PB dt = [Cc + Co ](T2 - T1 )
t

From the above equations the mean specific heat capacity can be calculated as:
C p (T1 - T2 )=

5.1.3

QE - QB
m t (T2 - T1 )

Continuous heating method

Temperature is increased linearly versus time at a constant heating rate ß. Using the same notation as in 5.1.2 the
thermal power PE supplied at every moment to the system is:

(

)

K ⋅ S c + t = mt Cp + C c + Co β

Another experiment for the determination of the base line is performed with the empty crucible. The corresponding
thermal power is given by
K ⋅ S c = (C c + C o ) β
--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

9


EN 1159-3:2003 (E)

The specific heat capacity can be calculated from:
Cp =

K (S c + t − S c )
mt β

with
K

the calibration factor and Sc, Sc+t are the output signals, where K ⋅ Sc and K ⋅ Sc+t are the thermal powers
supplied to the system.

5.2 Apparatus

5.2.1

Differential scanning calorimeter

There are two types of differential scanning calorimeters operating on power compensation and heat
5.2.1.1
flux principles, both designed to operate under adiabatic conditions.

Power compensation type: each cell has an additional heater to compensate for the temperature
5.2.1.2
variations from the overall heating programme. The power which is supplied to either cell heater to maintain equal
temperatures during heating is measured.
Heat flux type: power is exchanged between each cell and its respective surrounding, during the
5.2.1.3
heating programme. The difference in power exchange between the two cells is measured.
5.2.2

Balance, with an accuracy better than 0,1 mg.

5.2.3 Temperature detectors, thermocouples in accordance with EN 60584-1 shall be used for the
measurement of temperature.
5.2.4

Data acquisition system, the time duration between two successive measurements shall be less
than 0,5 s.

5.3 Standard reference materials, SRM
Standard reference materials shall be used for calibration. An example is given in annex B.

5.4 Test specimens

The test specimens shall be representative of the material.
NOTE
This criterion is generally met by test specimens containing the maximum number of representative volume
elements, compatible with the volume of the crucible, if this number is less that 5, several solutions are possible:

a) the test specimens should have an exact number of representative volume elements;
b) the material should be ground to powder and a specimen taken from this powder. However this solution will
lead to results which may differ from results obtained on solid test specimens and should only be used if no
other solution is possible;
c) the material should be cut into pieces and a number of similar test pieces should be tested and an average
value determined.

5.5 Temperature calibration
A temperature calibration curve for the furnace using the same heating rate as for the determination of the specific
heat capacity is established by using the melting points of standard reference materials (see for example annex C).
Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

10

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

Both comprise two measuring cells housed in a furnace which provides overall system heating. One cell contains
the test specimen and its crucible, the other contains an empty crucible only.



EN 1159-3:2003 (E)

Thermocouples shall be calibrated in accordance with EN 60584-1.

5.6 Test procedure for the determination of Cp
5.6.1

General

Depending on the necessity to use or not a calibration factor K for the calorimeter, two methods can be used:
Method 1: measurements requiring the knowledge of the K factor; in that case, care shall be taken in order to
ensure that the calibration is valid for all the measurements to be done.
NOTE

Generally, this can be done by running a test using a test specimen with well-known properties.

Method 2: measurements requiring the use of a reference standard material during a series of tests.
5.6.2

Method 1: Measurements requiring the knowledge of the K factor

5.6.2.1

Determination of the K factor

The calibration factor K is obtained by electrical calibration. It is determined from the ratio of a known amount of
power dissipated in a resistor to the steady state calorimetric output signal.
5.6.2.2
5.6.2.2.1


Measurements with the specimen for the determination of the Cp
General

5.6.2.2.2

Test sequence for the stepwise heating method (see Figure 1)

Generation of the base line:
1)

weigh the two empty crucibles to the nearest 0,1 mg;

2)

place the two crucibles in the calorimeter;

3)

set the calorimeter heating rate, initial and final temperature, and cooling rate;

NOTE

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

A series of measurements shall always be referenced to a base line measurement performed under identical
experimental conditions as the other measurements in the series. The type of crucible used depends on the type of
the test specimen and on the temperature range and shall be the same for the series of measurements. The mass
of all empty crucibles used in the series shall not differ by more than 5 %.

Generally the heating rate is in the range 1 K/min to 20 K/min.


4)

heat to an initial temperature, and wait for the temperature to be stabilised at the initial temperature;

5)

heat at a constant rate to final temperature of the first step while recording the calorimeter output signal
until the final temperature is reached and stabilised in order to obtain a base line;

6)

repeat 3 to 5 for the number of steps required;

7)

cool down to initial temperature;

8)

remove the crucibles from the measurement cell.

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

11



EN 1159-3:2003 (E)

Measurements using a test specimen
Weigh the test specimen and place it in the crucible to be located in the measurement cell. Repeat operations 2
to 8 of the above paragraph on generation of the base line. Repeat this procedure for a minimum of three test
specimens.
5.6.2.2.3

Test sequence for the continuous heating method (see Figure 2)

Generation of the base line:
1)

weigh the two empty crucibles to the nearest 0,1 mg;

2)

place the two crucibles in the calorimeter;

3)

set the calorimeter heating rate, initial and final temperature, and cooling rate;

NOTE

4)

Generally the heating rate is in the range 1 K/min to 20 K/min.


heat to an initial temperature, and wait for the temperature to be stabilised at the initial temperature;

5) heat at a constant rate to final temperature of the first step while recording the calorimeter output signal
until the final temperature is reached and stabilised in order to obtain a base line;
6)

cool down to initial temperature;

7)

remove the crucibles from the measurement cell.

Measurements using a test specimen
Weigh the test specimen and place it in the crucible to be located in the measurement cell. Repeat operations 2
to 7 of the above paragraph on generation of the base line. Repeat this procedure for a minimum of three test
specimens.
5.6.3
5.6.3.1

Method 2: Measurements requiring the use of a reference standard material (SRM)
General



measurements with two empty crucibles for the generation of the baseline;



measurements with one empty crucible and one crucible with the SRM;




measurements with one empty crucible and one crucible with the test specimen.

5.6.3.2

Test sequence for the stepwise heating method (see Figure 3)

Generation of the base line
1)

weigh the two empty crucibles to the nearest 0,1 mg;

2)

place the two crucibles in the calorimeter;

3)

set the calorimeter heating rate, initial and final temperature, and cooling rate;

NOTE

4)

Generally the heating rate is in the range 1 K/min to 20 K/min.

heat to an initial temperature, and wait for the temperature to be stabilised at the initial temperature;


Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

12

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

The two methods described in the following paragraphs 5.6.3.2 and 5.6.3.3 require each:


EN 1159-3:2003 (E)

5) heat at a constant rate to final temperature of the first step while recording the calorimeter output signal
until the final temperature is reached and stabilised in order to obtain a base line;
6)

repeat 3 to 5 for the number of steps required;

7)

cool down to initial temperature;

8)

remove the crucibles from the measurement cell.


Measurement with a test specimen or with a SRM
Weigh the test specimen or the SRM and place it in the crucible to be located in the measurement cell. Repeat
operations 2 to 8 of the above paragraph on generation of the base line. Repeat this procedure for a minimum of
three test specimens.
5.6.3.3

Test sequence for continuous heating method (see Figure 4)

Generation of the base line
1)

weigh the two empty crucibles to the nearest 0,1 mg;

2)

place the two crucibles in the calorimeter;

3)

set the calorimeter heating rate, initial and final temperature, and cooling rate;

NOTE

4)

Generally the heating rate is in the range 1 K/min to 20 K/min.

heat to an initial temperature, and wait for the temperature to be stabilised at the initial temperature;

6)


cool down to initial temperature;

7)

remove the crucibles from the measurement cell.

Measurements using a test specimen or an SRM
Weigh the test specimen or the SRM and place it in the crucible to be located in the measurement cell. Repeat
operations 2 to 6 of the above paragraph on generation of the base line. Repeat this procedure for a minimum of
three test specimens.

5.7 Calculation of results
5.7.1

Method requiring the knowledge of the K factor

5.7.1.1

Stepwise heating method (see Figure 1)

NOTE
The use of a computer with an adapted software greatly simplifies data acquisition and treatment, and its use is
recommended.

For the considered temperature interval the shaded areas, A, are the integrals of the output signal, s, with respect
to time.
For the base line run with an empty crucible, one obtains:
K ⋅ Ac = (C c + C o ) (T2 - T1 )


Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

13

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

5) heat at a constant rate to final temperature of the first step while recording the calorimeter output signal
until the final temperature is reached and stabilised in order to obtain a base line;


EN 1159-3:2003 (E)



For crucible plus test specimen:
K ⋅ A c + t = (m t C p + C c + C o ) (T2 - T1 )
t

From these two equations one obtains:
C pt (T1 , T2 ) =

K ( Ac + t - A c )
m t (T2 - T1 )

where


K

is the mean calorimeter calibration factor for the temperature range T1 to T2, in watt per volt, (W.V-1);

Co

is the heat capacity of the calorimeter, in joule per kelvin, (J.kg .K-1);

Cc

is the heat capacity of the crucible, in joule per kelvin, (J.kg .K-1);

Cpt

is the mean specific heat capacity of the test specimen, in joule per kilogram and per kelvin, (J.kg-1.K-1);

mt

is the mass of the test specimen, in kilogram, (kg).

-1

-1

5.7.1.2

Continuous heating method (see Figure 2)

Using the same notations as in 5.7.1.1 plus

Cp


as the specific heat capacity of the test specimen, one obtains for each temperature:

t

for the empty crucible:
KS c = (C c + C o ) β



for crucible plus test specimen:
KS c + t = (m t C p + C c + C o ) β
t

The specific heat capacity of the test specimen for each temperature T is then obtained from:
C pt =

K(S c + t - S c )
m t .β

where β is the constant heating rate in (K . S-1), K the calibration factor at a temperature T and Sc, Sc+t are the
output signals of the calorimeter in volt (V).
5.7.2
5.7.2.1

Method using an SRM
Stepwise heating method (see Figure 3)


NOTE
The use of a computer with an adapted software greatly simplifies data acquisition and treatment, and its use is
recommended.

For the considered temperature interval the shaded areas, A, are the integrals of the output signal, s, with respect
to time.
--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

14

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.


EN 1159-3:2003 (E)

For the base line run with an empty crucible, one obtains:
K Ac = (C c + C o ) (T2 - T1 )


for crucible plus test piece:
K A c + t = (m t C p + C c + C o ) (T2 - T1 )
t




for crucible plus reference piece:

K Ac + r = (mr Cp r + C c + C o ) (T2 - T1 )
where
K

-1

is the mean calorimeter calibration factor in watt per volt, (W.V );
-1

C o is the heat capacity of the calorimeter in joule per kelvin, (J.kg .K-1);
Cc

-1

is the heat capacity of the crucible in joule per kelvin, (J.kg .K-1);

C pt is the mean specific heat capacity of the test piece in joule per kilogram and per kelvin, (J.kg-1.K-1);

Cpr is the mean specific heat capacity of the reference piece in joule per kilogram and per kelvin, (J.kg-1.K-1);
mt

is the mass of the test specimen in kilogram, (kg);

mr

is the mass of the standard reference material in kilogram, (kg).

The mean specific heat capacity of the test piece is then obtained from:


Cpt (T1, T2 )= Cpr
5.7.2.2

mr (Ac + t − Ac)
mt (Ac +r − Ac )

Continuous heating method (see Figure 4)

Using the same notations as in 5.7.2.1 plus



Cpt

as the specific heat capacity of the test specimen;

Cpr

as the specific heat capacity of the standard reference material, one obtains for each temperature:

for the empty crucible:
KS c = (C c + C o ) β



for crucible plus test specimen:

KS c + t = (m t C pt + C c + C o ) β



for crucible plus standard reference material:


KSc +r =  mr Cpr + Cc + Co  β




--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

15


EN 1159-3:2003 (E)

The specific heat capacity of the test specimen for each temperature T is then obtained from:

Cpt = Cpr

mr.(Sc + t − Sc )
mt.(Sc + t − Sc )


where β is the constant heating rate in (Ks-1), K the calibration factor at a temperature T and S, Sc+t, Sc+r are the
output signals of the calorimeter in volt (V).

6

Test report

The test report shall contain at least the following information:
a)

name of the testing establishment;

b)

date of the test; a unique identification of the report and of each page, the customer’s and signatory's names
and addresses;

c)

reference to this European standard, i.e. “Determined in accordance with EN 1159-3”;

d)

type of method of measurement used;

e)

brief details of the equipment used, or any procedures adopted, including necessary deviations;

f)


calibration procedures if applicable;

g)

material type, manufacturing code, batch number;

h)

methods of production of test specimens from supplied material (if appropriate);

i)

relevant test parameters (as required for each test);

j)

results of individual tests on required number of test specimens;

k)

mean results and standard deviation (if required);

l)

comments about the test or the test results;

m) value of specific heat capacity at each required temperature, or value of the mean specific heat capacity
between two temperatures calculated on at least three test specimens.


--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

16

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.


EN 1159-3:2003 (E)

--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

Key
1

Output signal

2
3

Temperature
Time

4

Time


Figure 1 — Stepwise heating method (with calibration factor)

Key
1

Output signal

4

Time

2
3

Temperature
Time

5
6

Test piece
Base line

Figure 2 — Continuous heating method (with calibration factor)

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004

00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.

17


EN 1159-3:2003 (E)

Key
1

Output signal

2
3

Temperature
Time

4

Time

Figure 3 — Stepwise heating method (with standard reference material)

1

Output signal

5


Test piece

2
3

Temperature
Time

6
7

Base line
Reference

4

Time

Figure 4 — Continuous heating method (with standard reference material)

Copyright British Standards Institution
Reproduced by IHS under license with BSI - Uncontrolled Copy

18

Document provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/2004
00:17:52 MST Questions or comments about this message: please call the Document
Policy Group at 303-397-2295.


--`,,,,`,,`,,,,,,,``,`,,,``,``-`-`,,`,,`,`,,`---

Key



Tài liệu bạn tìm kiếm đã sẵn sàng tải về

Tải bản đầy đủ ngay
×