Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

BRITISH STANDARD

Fibre optic
interconnecting
devices and passive
components — Basic
test and measurement
procedures —
Part 2-22: Tests — Change of
temperature

The European Standard EN 61300-2-22:2007 has the status of a
British Standard

ICS 33.180.20

12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:

BS EN
61300-2-22:2007


BS EN 61300-2-22:2007

Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

National foreword
This British Standard is the UK implementation of EN 61300-2-22:2007. It is
identical to IEC 61300-2-22:2007. It supersedes BS EN 61300-2-22:1997 which


is withdrawn.
The UK participation in its preparation was entrusted by Technical Committee
GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting
devices and passive components.
A list of organizations represented on this committee can be obtained on
request to its secretary.
This publication does not purport to include all the necessary provisions of a
contract. Users are responsible for its correct application.
Compliance with a British Standard cannot confer immunity from
legal obligations.

This British Standard was
published under the authority
of the Standards Policy and
Strategy Committee
on 31 August 2007

© BSI 2007

ISBN 978 0 580 54207 7

Amendments issued since publication
Amd. No.

Date

Comments


EUROPEAN STANDARD


EN 61300-2-22

Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

NORME EUROPÉENNE
June 2007

EUROPÄISCHE NORM
ICS 33.180.20

Supersedes EN 61300-2-22:1997

English version

Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-22: Tests Change of temperature
(IEC 61300-2-22:2007)
Dispositifs d'interconnexion
et composants passifs à fibres optiques Méthodes fondamentales d'essais
et de mesures Partie 2-22: Essais Variations de température
(CEI 61300-2-22:2007)

Lichtwellenleiter Verbindungselemente
und passive Bauteile Grundlegende Prüf- und Messverfahren Teil 2-22: Prüfungen Temperaturwechsel
(IEC 61300-2-22:2007)

This European Standard was approved by CENELEC on 2007-04-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on

application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2007 CENELEC -

All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61300-2-22:2007 E


EN 61300-2-22:2007

–2–

Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

Foreword
The text of document 86B/2440/FDIS, future edition 2 of IEC 61300-2-22, prepared by SC 86B, Fibre
optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-22 on 2007-04-01.

This European Standard supersedes EN 61300-2-22:1997.
EN 61300-2-22:1997 specifies tests Na and Nb of EN 60068-2-14, however this EN 61300-2-22:2007
describes the test method of Nb and specifies “optional cycle” for some other performance categories.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement

(dop)

2008-01-01

– latest date by which the national standards conflicting
with the EN have to be withdrawn

(dow)

2010-04-01

Annexes ZA and ZB have been added by CENELEC.
__________

Endorsement notice
The text of the International Standard IEC 61300-2-22:2007 was approved by CENELEC as a European
Standard without any modification.
__________


–3–


EN 61300-2-22:2007

Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

CONTENTS

1

Scope ...............................................................................................................................4

2

Normative references .......................................................................................................4

3

General description ..........................................................................................................4

4

Apparatus .........................................................................................................................4

5

Procedure ........................................................................................................................4

6

5.1 Preconditioning .......................................................................................................5
5.2 Initial measurements ............................................................................................... 5

5.3 Testing ....................................................................................................................5
5.4 Recovery .................................................................................................................6
5.5 Final measurements ................................................................................................6
Severity ............................................................................................................................ 6

7

Details to be specified ...................................................................................................... 7

Bibliography............................................................................................................................ 8
Annex ZA (normative) Special national conditions ......................................................................... 9
Annex ZB (normative) Normative references to international publications with their
corresponding European publications ......................................................................................9
Figure 1 – Temperature profile................................................................................................ 5
Figure 2 – Optional temperature profile ................................................................................... 6
Table 1 – Severities ................................................................................................................ 6


Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

EN 61300-2-22:2007

–4–

FIBRE OPTIC INTERCONNECTING DEVICES AND
PASSIVE COMPONENTS –
BASIC TEST AND MEASUREMENT PROCEDURES –
Part 2-22: Tests – Change of temperature

1


Scope

This part of IEC 61300 describes a procedure to determine the suitability of a fibre optic
device to withstand the effects of a change of temperature or a succession of changes of
temperature.

2

Normative references

The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60068-2-14, Basic environmental testing procedures – Part 2-14: Tests – Test N: Change
of temperature

3

General description

This procedure is conducted in accordance with IEC 60068-2-14, test Nb. The device under
test (DUT) is first subjected to one extreme of temperature for a given period of time. It is then
subjected to the other extreme of temperature for an equal period of time.

4

Apparatus

The apparatus consists of suitable environmental chambers in accordance with IEC 60068-214, test Nb.

The rate of change of temperature shall be: (1 ± 0,2) °C/min

5

Procedure

These procedures are in accordance with IEC 60068-2-14, test Nb.
Unless otherwise stated in the relevant specification:


include 1,5 m of cable in the climatic chamber for each port monitored during the test;



if optical measurements are requested during the test by the relevant specification, these
measurements shall be performed (at a minimum) at the end of each dwell at each
temperature extreme;



allow dependence on wavelength scan time for components that require wavelength
scanning.


–5–
Preconditioning

Unless otherwise stated in the relevant specification, maintain the DUT under standard
atmospheric conditions for 2 h minimum. Clean the mechanical and optical alignment parts of
the DUT according to the manufacturer's instructions.

5.2

Initial measurements

Take initial examinations and measurements as required by the relevant specification.
5.3

Testing

5.3.1 Place the specimen in the chamber in its normal operating position and make
connections to the monitoring equipment.
5.3.2 Unless otherwise specified, the temperature profile in Figure 1 shall be applied. Start
at standard atmospheric conditions and ramp down to the low temperature T A at 1 °C/min.
Maintain the low temperature during t 1 for a minimum of 60 min. Ramp up to the high
temperature T B at 1 °C/min. Maintain the temperature during t 1 , then ramp down to the low
temperature and repeat this profile for the required number of cycles.

TB
t1
Temperature in
the chamber

Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

5.1

EN 61300-2-22:2007

A
Time t


t1

TA
First cycle

Second cycle
IEC 263/07

A = start of first cycle.

Figure 1 – Temperature profile
NOTE It is permissible to increase the dwell time at each extreme to allow sufficient time to perform a complete
set of measurements.

5.3.3 Optional cycle: for some performance categories, it may be necessary to ramp to the
high temperature first and include a dwell at room temperature between ramps to the extreme
temperatures. In this case, the profile in Figure 2 shall be applied.
Start at standard atmospheric conditions and ramp up to the high temperature T at 1 °C/min.
Then maintain the high temperature during t 1 for a minimum of 60 min. Ramp down to
standard atmospheric conditions at 1 °C/min. Maintain standard atmospheric conditions for a
minimum of 60 min. Ramp down to the low temperature T L at 1 °C/min. Maintain that
temperature during t 1 for a minimum of 60 min. Ramp up to standard atmospheric conditions
at 1 °C/min and dwell for a minimum of 60 min. The subsequent cycles will have the same
pattern.


Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

EN 61300-2-22:2007


–6–

Second cycle

First cycle
T
t1

t1

A

Time t

TL

IEC 264/07

A = start of first cycle

Figure 2 – Optional temperature profile
5.4

Recovery

Allow the specimen to remain under standard atmospheric conditions for a period of at least
2 h.
5.5


Final measurements

Record final measurements as required by the relevant specification. Unless otherwise
specified in the relevant specification, clean the DUT according to the manufacturer's
instructions prior to recording final measurements.

6

Severity

Each of the following severities consist of a combination of a low temperature with the
corresponding high temperature and the corresponding number of cycles. One of them shall
be specified in the relevant specification:
Table 1 – Severities
Category

Low temperature

High temperature

Number of cycles

°C

°C

C

–10


+60

5

U

–25

+70

12

E

–40

+85

12

O

–40

+75

21

A


–40

+65

20

G

–40

+65

20

S

–30

+60

20


–7–

Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

7

EN 61300-2-22:2007


Details to be specified

The following details, as applicable, shall be specified in the relevant specification:


severity;



initial examinations and measurements and performance requirements;



examinations and measurements during test and performance requirements;



final examinations and measurements and performance requirements;



deviations from test procedure;



additional pass/fail criteria;




relevant monitoring procedure.


EN 61300-2-22:2007

–8–

Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

Bibliography
IEC 61300-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 1: General and guidance
NOTE Harmonized as EN 61300-1:2003 (not modified).

IEC 61300-2-47, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-47: Tests – Thermal shocks
NOTE Harmonized as EN 61300-2-47:2007 (not modified).

___________


–9–

EN 61300-2-22:2007

Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

Annex ZA
(normative)
Special national conditions

Special national condition: National characteristic or practice that cannot be changed even over a long
period, e.g. climatic conditions, electrical earthing conditions.
NOTE If it affects harmonization, it forms part of the European Standard / Harmonization Document.

For the countries in which the relevant special national conditions apply these provisions are normative,
for other countries they are informative.
Clause

Special national condition

6, Table 1

Finland
In the categories E, O, A and G, the minimum temperature shall be –45 °C.
__________

Annex ZB
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication

Year


IEC 60068-2-14

-

1)

Title

EN/HD

EN 60068-2-14
Environmental testing Part 2: Tests - Test N: Change of temperature
__________

Year
2)

1999


Licensed copy: Bradford University, University of Bradford, Version correct as of 21/03/2012 14:31, (c) The British Standards Institution 2012

BS EN
61300-2-22:2007

BSI — British Standards Institution
BSI is the independent national body responsible for preparing
British Standards. It presents the UK view on standards in Europe and at the
international level. It is incorporated by Royal Charter.
Revisions

British Standards are updated by amendment or revision. Users of
British Standards should make sure that they possess the latest amendments or
editions.
It is the constant aim of BSI to improve the quality of our products and services.
We would be grateful if anyone finding an inaccuracy or ambiguity while using
this British Standard would inform the Secretary of the technical committee
responsible, the identity of which can be found on the inside front cover.
Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.
BSI offers members an individual updating service called PLUS which ensures
that subscribers automatically receive the latest editions of standards.
Buying standards
Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: +44 (0)20 8996 9001.
Fax: +44 (0)20 8996 7001. Email: Standards are also
available from the BSI website at .
In response to orders for international standards, it is BSI policy to supply the
BSI implementation of those that have been published as British Standards,
unless otherwise requested.
Information on standards
BSI provides a wide range of information on national, European and
international standards through its Library and its Technical Help to Exporters
Service. Various BSI electronic information services are also available which give
details on all its products and services. Contact the Information Centre.
Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email:
Subscribing members of BSI are kept up to date with standards developments
and receive substantial discounts on the purchase price of standards. For details
of these and other benefits contact Membership Administration.
Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001.
Email:
Information regarding online access to British Standards via British Standards

Online can be found at />Further information about BSI is available on the BSI website at
.
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any
means – electronic, photocopying, recording or otherwise – without prior written
permission from BSI.

BSI
389 Chiswick High Road
London
W4 4AL

This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.
Details and advice can be obtained from the Copyright & Licensing Manager.
Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553.
Email:



Tài liệu bạn tìm kiếm đã sẵn sàng tải về

Tải bản đầy đủ ngay
×