Tải bản đầy đủ (.pdf) (20 trang)

Bsi bs en 61753 083 2 2008

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (556.43 KB, 20 trang )

BRITISH STANDARD

Fibre optic
interconnecting
devices and passive
components
performance
standard —
Part 083-2: Non-connectorised singlemode fibre optic C-band/L-band WDM
devices for category C — Controlled
environment

ICS 33.180.20

12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:

BS EN
61753-083-2:
2008


BS EN 61753-083-2:2008

National foreword
This British Standard is the UK implementation of EN 61753-083-2:2008. It is
identical to IEC 61753-083-2:2007.
The UK participation in its preparation was entrusted by Technical Committee
GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting
devices and passive components.
A list of organizations represented on this committee can be obtained on
request to its secretary.


This publication does not purport to include all the necessary provisions of a
contract. Users are responsible for its correct application.
Compliance with a British Standard cannot confer immunity from
legal obligations.

This British Standard was
published under the authority
of the Standards Policy and
Strategy Committee
on 31 March 2008

© BSI 2008

ISBN 978 0 580 55516 9

Amendments/corrigenda issued since publication
Date

Comments


EUROPEAN STANDARD

EN 61753-083-2

NORME EUROPÉENNE
February 2008

EUROPÄISCHE NORM
ICS 33.180.20


English version

Fibre optic interconnecting devices
and passive components performance standard Part 083-2: Non-connectorised single-mode fibre
optic C-band/L-band WDM devices for category C Controlled environment
(IEC 61753-083-2:2007)
Norme de qualité de fonctionnement
des dispositifs d'interconnexion
et composants passifs à fibres optiques Partie 083-2: Dispositifs WDM
bande C/bande L à fibres optiques
unimodales, non connectorisés,
pour catégorie C Environnement contrôlé
(CEI 61753-083-2:2007)

Lichtwellenleiter Verbindungselemente
und passive Bauteile Betriebsverhalten Teil 083-2: Nicht mit Steckverbindern
versehene Einmoden-LichtwellenleiterC-Band/L-Band-WDM-Bauteile
für die Kategorie C Kontrollierte Umgebung
(IEC 61753-083-2:2007)

This European Standard was approved by CENELEC on 2008-02-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the

Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.

CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC -

All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61753-083-2:2008 E


BS EN 61753-083-2:2008

–2–

Foreword
The text of document 86B/2447/FDIS, future edition 1 of IEC 61753-083-2, prepared by SC 86B, Fibre
optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 61753-083-2 on 2008-02-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement

(dop)


2008-11-01

– latest date by which the national standards conflicting
with the EN have to be withdrawn

(dow)

2011-02-01

Annex ZA has been added by CENELEC.
__________

Endorsement notice
The text of the International Standard IEC 61753-083-2:2007 was approved by CENELEC as a European
Standard without any modification.
__________


–3–

BS EN 61753-083-2:2008

CONTENTS
1

Scope ...............................................................................................................................4

2

Normative references .......................................................................................................4


3

Definitions ........................................................................................................................ 6

4

Abbreviated terms ............................................................................................................6

5

Test procedure .................................................................................................................6

6

Test report........................................................................................................................6

7

Performance requirements ...............................................................................................6
7.1
7.2

Dimensions .............................................................................................................6
Test details and requirements .................................................................................6

Annex A (normative) Sample size, sequencing and grouping requirements .......................... 12
Annex ZA (normative) Normative references to international publications with their
corresponding European publications ................................................................................... 14
Bibliography.......................................................................................................................... 13

Table 1 – Test details and requirements ................................................................................. 7
Table A.1 – Sequencing and number of samples for each test .............................................. 12

www.bzfxw.com


BS EN 61753-083-2:2008

–4–

FIBRE OPTIC INTERCONNECTING DEVICES AND
PASSIVE COMPONENTS PERFORMANCE STANDARD –
Part 083-2: Non-connectorised single-mode fibre optic
C-band/L-band WDM devices for category C –
Controlled environment

1

Scope

This part of IEC 61753 contains the minimum initial test and measurement requirements and
severities which a fibre optic C-band/L-band WDM device shall satisfy in order to be
categorised as meeting the IEC standard, Category C – controlled environment. The
requirements cover devices with single-mode non-connectorised pigtails.
C-band/L-band WDM devices combine and / or split C band and L band optical signals. A
guard band is required between the used wavelength in the C and L band.
Commercially available C-band/L-band WDM devices have narrower wavelength ranges such
as 1 530 nm to 1 564 nm for C-band and 1 574 nm to 1 625 nm for L-band, compared with
ITU-T Supplement N.39 Definitions, 1 530 nm to 1 565 nm for C-band and 1 565 nm to 1
625 nm for L-band. This standard describes performance standards for commercially available

C-band/L-band WDM devices.

2

Normative references

www.bzfxw.com

The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60793-2-50, Optical fibres – Part 2-50: Product specifications - Sectional specification for
class B single-mode fibres
IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)
IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention
IEC 61300-2-9, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-9: Tests – Shock
IEC 61300-2-14, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-14: Tests – Optical power handling and damage
threshold characterisation


–5–

BS EN 61753-083-2:2008

IEC 61300-2-17, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-17: Tests – Cold

IEC 61300-2-18, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-18: Tests – Dry heat - High temperature endurance
IEC 61300-2-19, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-19: Tests – Damp heat (steady state)
IEC 61300-2-22, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-22: Tests – Change of temperature
IEC 61300-2-42, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-42: Tests – Static side load for connectors
IEC 61300-2-44, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-44: Tests – Flexing of the strain relief of fibre optic
devices
IEC 61300-3-2, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-2: Examinations and measurements – Polarization
dependence of attenuation in a single-mode fibre optic device
IEC 61300-3-6, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-6: Examinations and measurements – Return loss

www.bzfxw.com

IEC 61300-3-7, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 3-7: Examinations and measurements – Wavelength
dependence of attenuation and return loss

IEC 61300-3-20, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 3-20: Examinations and measurements – Directivity of
fibre optic branching devices
IEC 61300-3-32, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 3-32: Examinations and measurements – Polarisation
mode dispersion measurement for passive optical components


IEC/PAS 61300-3-38, Fibre optic interconnecting devices and passive components – Basic
test and measurement procedures – Part 3-38: Examinations and measurements – Group
delay and chromatic dispersion 1
IEC 61753-021-2: Fibre optic interconnecting devices and passive component performance
standard – Part 021-2: Fibre optic connectors terminated on single mode fibre for category C
– Controlled environment

___________
1

To be published.


BS EN 61753-083-2:2008
3

–6–

Definitions

3.1
guard band
a wavelength range between two wavelength ranges C-band/L-band. WDM devices combine
and/or split C-band and L-band wavelength ranges

4

Abbreviated terms

JME


Jones matrix eigenanalysis

MPS

modulation phase shift

PMD

polarization mode dispersion

PSA

Poincaré sphere analysis

WDM

wavelength division multiplexing

5

Test procedure

Unless otherwise specified, all test methods are in accordance with the appropriate
IEC 61300 standard (see Table 1). Each test defines the number of samples to be evaluated.
The samples used for each test are intended to be previously unstressed new samples but
may also be selected from previously used samples if desired. The samples shall be
terminated onto single-mode fibres as per IEC 60793-2-50. All measurements shall be carried
out at normal room conditions, unless otherwise stated.


www.bzfxw.com

The tests shall be performed in sequential order as shown in Table A.1.

All tests are to be carried out to validate performance over the required operating wavelength
range. All tests shall be carried out over the optical wavelength 1 530 nm to 1 564 nm and
1 574 nm to 1 625 nm, unless otherwise stated.

6

Test report

Fully documented test reports and supporting evidence shall be prepared and be available for
inspection as evidence that the tests have been carried out and complied with.

7
7.1

Performance requirements
Dimensions

Dimensions shall comply with either an appropriate IEC interface standard or with those given
in appropriate manufacturers drawings, where the IEC interface standard does not exist or
cannot be used.
7.2

Test details and requirements

The requirements are given only for pigtailed WDM devices. For connectorised components
the connector performances shall be in compliance with IEC 61753-021-2.



–7–

BS EN 61753-083-2:2008

A minimum length of fibre or cable of 1,5 m per port shall be included in all climatic and
environmental tests.
The test details and requirements are given in Table 1.
Table 1 – Test details and requirements
No
1

Tests

Requirements

Attenuation

≤ 0,8 dB

IEC 61300-3-7

Attenuation shall be met over the following
operating wavelength range.
Operating wavelength range in C-band:
1 530 nm - 1 564 nm.
Operating wavelength range in L-band:
1 574 nm - 1 625 nm.


Details
This test shall be performed over
1 530 nm – 1 564 nm and
1 574 nm – 1 625 nm.
Launch fibre length: ≥ 1,5 m.
Source: depolarized.
Spectral width of light source shall
be narrower than 1 nm. Tunable
wavelength light source is
recommended.
The test conditions shall provide
attenuation measurement results
with accuracy of < ±0,05 dB over
the operating wavelength range.

2

Out of band
attenuation
IEC 61300-3-7

≥12 dB (pass band wavelengths)

Details: same as in test No. 1

≥25 dB (Blocked wavelengths)
Out of band attenuation shall be met over the
operating wavelength range.

www.bzfxw.com


Operating wavelength range in C-band:
1 530 nm – 1 564 nm.
Operating wavelength range in L-band:
1 574 nm – 1 625 nm.
3

Directivity

≥35 dB Class T

Details: same as in test No. 1

IEC 61300-3-20

≥60 dB Class V

All ports not under test shall be
terminated to avoid unwanted
reflections contributing to the
measurement.

Directivity shall be met over the operating
wavelength range.
Operating wavelength range in C-band:
1 530 nm – 1 564 nm.

Other conditions:

Operating wavelength range in L-band:

1 574 nm – 1 625 nm.

The directivity shall be measured
between any pair of input or output
ports.


BS EN 61753-083-2:2008

No
4

5

Tests

–8–

Requirement

Return loss

≥35 dB Type T

IEC 61300-3-6

≥60 dB Type V

Test over the full C-Band and LBand wavelength range (1 530 nm
to 1 625 nm).


Return loss shall be met over the operating
wavelength range.

Test to be performed at each input
port and output port.

Operating wavelength range in C-band:
1 530 nm – 1 564 nm.

RL accuracy shall be less than
±0,1 dB.

Operating wavelength range in L-band:
1 574 nm – 1 625 nm.

All ports not under test shall be
terminated to avoid unwanted
reflections contributing to the
measurement.

≤0,2 dB

Option 1, Method A;

PDL shall be met over operating wavelength
range.

Other details: same as in test
No. 1.


Operating wavelength range in C-band:
1 530 nm -1 564 nm.

The allowable loss combination
applies to all combination of input
and output ports.

Polarisation
dependent loss
IEC 61300-3-2

Operating wavelength range in L-band:
1 574 nm – 1 625 nm.
6

Details

Wavelength
dependent loss
IEC 61300-3-7

≤0,3 dB

Details: same as in test No. 1

Wavelength dependent loss shall be met over
operating wavelength range.
Operating wavelength range in C-band:
1 530 nm – 1 564 nm.

Operating wavelength range in L-band:
1 574 nm -1 625 nm.

7

Chromatic
dispersion
IEC 61300-3-38

≤5 ps/nm.

www.bzfxw.com
MPS method is recommended.

Chromatic dispersion shall be met over
operating wavelength range.

Operating wavelength range in C-band:
1 530 nm – 1 564 nm.
Operating wavelength range in L-band:
1 574 nm – 1 625 nm.
8

Polarisation mode
dispersion (PMD)
IEC 61300-3-32

≤0,1 ps
PMD shall be met over operating wavelength
range.

Operating wavelength range in C-band:
1 530 nm – 1 564 nm.
Operating wavelength range in L-band:
1 574 nm – 1 625 nm.

Either of the JME or the PSA
method is recommended.


–9–

No
9

Tests

Requirement

Optical power
handling and
damage threshold
characterisation

≥500 mW

IEC 61300-2-14

After the test the out of band attenuation limits
of test No. 2 shall be met.


After the test the attenuation limits of test No. 1
shall be met.

After the test the return loss limits of test No. 4
shall be met.

BS EN 61753-083-2:2008

Details
Power level increments on short
term test: defined by low power
insertion loss of samples.
Test wavelength on short term test:
1 550 nm and 1 590 nm.
Duration of short term exposure:
3 h.
Test wavelength(s) on long term
test: dependant on actual
operating wavelength or band.
Duration of long term test: 500 h.

10

Vibration
IEC 61300-2-1

11

Cold
IEC 61300-2-17


After the test the attenuation limits of test No. 1
shall be met, and the attenuation shall be within
±0,5 dB of the original value.

Frequency range: 10 Hz -55 Hz

After the test the out of band attenuation limits
of test No. 2 shall be met.

Amplitude: 0,75 mm

After the test the return loss limits of test No. 4
shall be met.

Number of cycles (10 Hz – 55 Hz 10 Hz): 15

During the test the attenuation value shall be
measured at a maximum interval of 1 h.

Temperature: (–10 ± 2) °C;

During and after the test the attenuation limits
of test No. 1 shall be met, and the attenuation
shall be within ±0,5 dB of the original value.
After the test the out of band attenuation limits
of test No. 2 shall be met.

Dry heat - High
temperature

endurance
IEC 61300-2-18

Duration per axis: 0,5 h

Exposure duration: 96 h;
Preconditioning procedure:
standard atmospheric condition for
2 h;
Recovery procedure: allow
specimen to return to 20 °C in
period not exceeding 2 h.

www.bzfxw.com

After the test the return loss limits of test No. 4
shall be met.
12

Number of axis: 3 orthogonal

During the test the attenuation value shall be
measured at maximum interval of 1 h during the
first 16 h, and thereafter at a maximum interval
of 24 h until completion of the test.
During and after the test the attenuation limits
of test No. 1 shall be met, and the attenuation
shall be within ±0,5 dB of the original value.
After the test the out of band attenuation limits
of test No. 2 shall be met.

After the test the return loss limits of test No. 4
shall be met.

Temperature: (+60 ± 2) °C;
Exposure duration: 96 h ;

Preconditioning procedure:
standard atmospheric condition for
2 h;
Recovery procedure: allow
specimen to return to 20 °C in
period not exceeding 2 h.


BS EN 61753-083-2:2008

No
13

14

Tests

– 10 –

Requirement

Details
Temperature: (+40 ± 2) °C;


Damp heat (steady
state)

During the test the attenuation value shall be
measured at maximum interval of 1 h.

IEC 61300-2-19

During and after the test the attenuation limits
of test No. 1 shall be met, and the attenuation
shall be within ±0,5 dB of the original value.

Exposure duration: 96 h;

After the test the out of band attenuation limits
of test No. 2 shall be met.

Preconditioning procedure:
standard atmospheric condition for
2 h;

Relative Humidity: 93 −+32 %;

After the test the return loss limits of test No. 4
shall be met.

Recovery procedure: allow
specimen to return to 20 °C in
period not exceeding 2 h.


Change of
temperature

During the test the attenuation value shall be
measured at maximum interval of 30 min.

High temperature: (+60 ± 2) °C;

IEC 61300-2-22
Test Nb

During the test the attenuation limits of test
No. 1 shall be met. During and after the test the
attenuation shall be within ±0,5 dB of the
original value at ambient conditions.

Duration at extreme temperature:
1 h;

After the test the out of band attenuation limits
of test No. 2 shall be met.

Rate of temperature change:
1 °C/min;

After the test the return loss limits of test No. 4
shall be met.

Preconditioning procedure:
standard atmospheric condition for

2 h;

Low temperature: (–10 ± 2) °C;

Number of cycles: 5;

Recovery procedure: allow
specimen to return to 20 °C in
period not exceeding 2 h.
15

Optical fibre cable
flexing
IEC 61300-2-44

www.bzfxw.com

During the test the attenuation limits of test
No. 1 shall be met. During and after the test the
attenuation shall be within ±0,5 dB of the
original value at ambient conditions.

Tensile load: 2 N for reinforced
cable;

After the test the out of band attenuation limits
of test No. 2 shall be met.

Number of cycles: 30 times.


Cycle: ±90;

After the test the return loss limits of test No. 4
shall be met.
16

Fibre/Cable
retention
IEC 61300-2-4

During the test the attenuation limits of test
No. 1 shall be met. During and after the test the
attenuation shall be within ±0,5 dB of the
original value at ambient conditions.
After the test the out of band attenuation limits
of test No. 2 shall be met.
After the test the return loss limits of test No. 4
shall be met.

17

Static side load
IEC 61300-2-42

During the test the attenuation limits of test
No. 1 shall be met. During and on completion of
the test the attenuation shall be within ±0,5 dB
of the original value at ambient conditions.
After the test the out of band attenuation limits
of test No. 2 shall be met.

After the test the return loss limits of test No. 4
shall be met.

Pulling force: (10 ± 1) N at 5 N/s
for reinforced cables;
(5 ± 0,5) N at 0,.5 N/s for
secondary coated fibres;
Point of application: 0,3 m from the
end of the device of the tensile
load;
Duration of the test: 120 s at 10 N
and 60 s at 5 N (maintaining the
load).
Tensile load: 1 N for 1 h for
reinforce cable;
Tensile load: 0,2 N for 5 min for
buffered fibres;
Two mutually perpendicular
directions.


– 11 –

No
18

Tests
Shock
IEC 61300-2-9


BS EN 61753-083-2:2008

Requirement
After the test the attenuation limits of test No. 1
shall be met, and the attenuation shall be within
±0,5 dB of the original value at ambient
conditions.
After the test the out of band attenuation limits
of test No. 2 shall be met.
After the test the return loss limits of test No. 4
shall be met.

Details
Components;
Shock: 500 g n
Modules;
0,125 kg ≤ module mass
<0,225 kg: 200 g n
0,225kg ≤ module mass
<1 kg: 50 g n
Number of axis: 6
Number of shock: 2 per axis
Duration: 1 ms duration
Pulse: half sine

www.bzfxw.com


BS EN 61753-083-2:2008


– 12 –

Annex A
(normative)
Sample size, sequencing and grouping requirements
The sequential order for the tests is given in the following Table A.1. The number of samples
to be evaluated for each test is defined in the sample size column.
Table A.1 – Sequencing and number of samples for each test

Sequence
number

Tests

Sample size

1

Attenuation

12

2

Out of band attenuation

12

3


Directivity

12

4

Return loss

12

5

Polarisation dependent loss

12

6

Wavelength dependent loss

12

7

Chromatic dispersion

12

8


Polarisation mode dispersion

12

9

Optical power handling and damage threshold
characterisation

4

10

Vibration

4

11

Cold

12

Dry heat - High temperature endurance

4

13

Damp heat (steady state)


4

14

Change of temperature

4

15

Optical fibre cable flexing

4

16

Fibre/Cable retention

4

17

Static side load

4

18

Shock


4

www.bzfxw.com
4


– 13 –

BS EN 61753-083-2:2008

Bibliography
ITU-T Recommendation G.671: Transmission characteristics of optical components and subsystems
ITU-T Recommendation G.694.1: Spectral grids for WDM applications: DWDM frequency grid
ITU-T Recommendation G Sup39: Optical system design and engineering considerations

___________

www.bzfxw.com


BS EN 61753-083-2:2008

– 14 –

Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Publication

Year

Title

EN/HD

Year

Optical fibres Part 2-50: Product specifications - Sectional
specification for class B single-mode fibres

EN 60793-2-50
+ corr. July

2004
2004

2)

IEC 60793-2-50

-


1)

IEC 61300-2-1

-

1)

Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-1: Tests - Vibration (sinusoidal)

EN 61300-2-1

2003

2)

IEC 61300-2-4

-

1)

Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-4: Tests - Fibre/cable retention

EN 61300-2-4


1997

2)

IEC 61300-2-9

-

1)

Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-9: Tests - Shock

EN 61300-2-9

1997

2)

IEC 61300-2-14

-

1)

Fibre optic interconnecting devices and
EN 61300-2-14
passive components - Basic test and
+ corr. November

measurement procedures Part 2-14: Tests - Optical power handling and
damage threshold characterization

2006
2006

2)

IEC 61300-2-17

-

1)

Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-17: Tests - Cold

EN 61300-2-17

2003

2)

IEC 61300-2-18

-

1)


Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-18: Tests - Dry heat - High
temperature endurance

EN 61300-2-18

2005

2)

IEC 61300-2-19

-

1)

Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-19: Tests - Damp heat (steady state)

EN 61300-2-19

2005

2)

1)

Undated reference.


2)

Valid edition at date of issue.

www.bzfxw.com


– 15 –
Publication
IEC 61300-2-22

Year
1)
-

IEC 61300-2-42

-

IEC 61300-2-44

BS EN 61753-083-2:2008

Title
Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-22: Tests - Change of temperature

EN/HD

EN 61300-2-22

Year
2)
2007

1)

Fibre optic interconnecting devices and
passive components - Basic test and
measurement procedures Part 2-42: Tests - Static side load for
connectors

EN 61300-2-42

2005

2)

-

1)

Fibre optic interconnecting devices and
EN 61300-2-44
passive components - Basic test and
measurement procedures Part 2-44: Tests - Flexing of the strain relief of
fibre optic devices

2005


2)

IEC 61300-3-2

-

1)

Fibre optic interconnecting devices and
EN 61300-3-2
passive components - Basic tests and
measurement procedures Part 3-2: Examinations and measurements Polarization dependence of attenuation in a
single-mode fibre optic device

1999

2)

IEC 61300-3-6

-

1)

Fibre optic interconnecting devices and
EN 61300-3-6
passive components - Basic test and
measurement procedures Part 3-6: Examinations and measurements Return loss


2003

2)

IEC 61300-3-7

-

1)

Fibre optic interconnecting devices and
EN 61300-3-7
passive components - Basic test and
measurement procedures Part 3-7: Examinations and measurements Wavelength dependence of attenuation and
return loss

2001

2)

IEC 61300-3-20

-

1)

Fibre optic interconnecting devices and
EN 61300-3-20
passive components - Basic test and
+ corr. March

measurement procedures Part 3-20: Examinations and measurements Directivity of fibre optic branching devices

2001
2002

2)

IEC 61300-3-32

-

1)

Fibre optic interconnecting devices and
EN 61300-3-32
passive components - Basic test and
measurement procedures Part 3-32: Examinations and measurements Polarisation mode dispersion measurement
for passive optical components

2006

2)

IEC/PAS 61300-3-38

-

1)

Fibre optic interconnecting devices and

passive components - Basic test and
measurement procedures Part 3-38: Group delay and chromatic
dispersion

-

www.bzfxw.com

-


BS EN 61753-083-2:2008
Publication
IEC 61753-021-2

Year
1)
-

– 16 –

Title
EN/HD
Fibre optic interconnecting devices and
EN 61753-021-2
passive component performance standard Part 021-2: Fibre optic connectors terminated
on single-mode fibre for category C Controlled environment

Year
2)

2008

www.bzfxw.com


www.bzfxw.com

blank


BS EN
61753-083-2:
2008

BSI — British Standards Institution
BSI is the independent national body responsible for preparing
British Standards. It presents the UK view on standards in Europe and at the
international level. It is incorporated by Royal Charter.
Revisions
British Standards are updated by amendment or revision. Users of
British Standards should make sure that they possess the latest amendments or
editions.
It is the constant aim of BSI to improve the quality of our products and services.
We would be grateful if anyone finding an inaccuracy or ambiguity while using
this British Standard would inform the Secretary of the technical committee
responsible, the identity of which can be found on the inside front cover.
Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.
BSI offers members an individual updating service called PLUS which ensures
that subscribers automatically receive the latest editions of standards.
Buying standards

Orders for all BSI, international and foreign standards publications should be
addressed to Customer Services. Tel: +44 (0)20 8996 9001.
Fax: +44 (0)20 8996 7001. Email: Standards are also
available from the BSI website at .
In response to orders for international standards, it is BSI policy to supply the
BSI implementation of those that have been published as British Standards,
unless otherwise requested.
Information on standards

www.bzfxw.com

BSI provides a wide range of information on national, European and
international standards through its Library and its Technical Help to Exporters
Service. Various BSI electronic information services are also available which give
details on all its products and services. Contact the Information Centre.
Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email:
Subscribing members of BSI are kept up to date with standards developments
and receive substantial discounts on the purchase price of standards. For details
of these and other benefits contact Membership Administration.
Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001.
Email:
Information regarding online access to British Standards via British Standards
Online can be found at />Further information about BSI is available on the BSI website at
.
Copyright
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any
means – electronic, photocopying, recording or otherwise – without prior written

permission from BSI.

BSI
389 Chiswick High Road
London
W4 4AL

This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.
Details and advice can be obtained from the Copyright & Licensing Manager.
Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553.
Email:



Tài liệu bạn tìm kiếm đã sẵn sàng tải về

Tải bản đầy đủ ngay
×