Tải bản đầy đủ (.pdf) (66 trang)

Bsi bs en 62196 2 2012 + a12 2014

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (6.17 MB, 66 trang )

BS EN 62196-2:2012+A12:2014
62196-2:2012+A11:2013
Incorporating
corrigenda
September
2012
and
October2012
2014
Incorporating
corrigendum
September
2012
Incorporating
corrigendum
September

BSI Standards Publication

Plugs, socket-outlets,
vehicle connectors and
vehicle inlets — Conductive
charging of electric vehicles
Part 2: Dimensional compatibility and
interchangeability requirements for a.c.
pin and contact-tube accessories


BS EN 62196-2:2012+A12:2014

BRITISH STANDARD


National foreword
This British Standard is the UK implementation of
EN 62196-2:2012+A12:2014, incorporating corrigendum
October 2014. It is identical to IEC 62196-2:2011. It supersedes
BS EN 62196-2:2012+A11:2013, which will be withdrawn on 16 June 2017.
Where a common modification has been introduced by amendment,
the tags carry the number of the amendment. For example, the common
modifications introduced by CENELEC amendment A11 are indicated
by .
The UK participation in its preparation was entrusted by Technical
Committee PEL/23, Electrical accessories, to Subcommittee PEL/23/4,
Protected type plugs and sockets.
A list of organizations represented on this subcommittee can be
obtained on request to its secretary.
This publication does not purport to include all the necessary provisions
of a contract. Users are responsible for its correct application.
© The British Standards Institution 2014.
Published by BSI Standards Limited 2014
ISBN 978 0 580 88428 3
ICS 29.120.30; 43.120

Compliance with a British Standard cannot confer immunity from
legal obligations.
This British Standard was published under the authority of the Standards
Policy and Strategy Committee on 30 June 2012.

Amendments/corrigenda issued since publication
Date

Text affected


30 September 2012

Inserted missing pages (pp.23-63)

30 June 2013

Implementation of CENELEC amendment A11:2013

30 September 2014

Implementation of CENELEC amendment A12:2014:
STANDARD SHEET 2-IIa (Sheet 1) and STANDARD
SHEET 2-IIa (Sheet 2) updated

30 November 2014

Implementation of CENELEC corrigendum October 2014:
STANDARD SHEET 2-IIa (Sheet 1) replaced


EN
EN
62196-2:2012+A11
EN62196-2:2012+A12
62196-2

EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM


August
2014
May2013
2012
April
Incorporating corrigendum October 2014

ICS 29.120.30; 43.120

English version

Plugs, socket-outlets, vehicle connectors and vehicle inlets Conductive charging of electric vehicles Part 2: Dimensional compatibility and interchangeability requirements for
a.c. pin and contact-tube accessories
(IEC 62196-2:2011)
Fiches, socles de prise de courant, prises
mobiles et socles de connecteurs de
véhicule Charge conductive des véhicules
électriques Partie 2: Exigences dimensionnelles de
compatibilité et d’interchangeabilité pour
les appareils à broches et alvéoles pour
courant alternatif
(CEI 62196-2:2011)

Stecker, Steckdosen,
Fahrzeugkupplungen und
Fahrzeugstecker Konduktives Laden von
Elektrofahrzeugen Teil 2: Anforderungen und Hauptmaße für
die Kompatibilität und Austauschbarkeit
von Stift- und Buchsensteckvorrichtungen

für Wechselstrom
(IEC 62196-2:2011)

This European Standard was approved by CENELEC on 2012-02-01. CENELEC members are bound to comply
with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard
the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and notified
to the CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,
Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2012 CENELEC -

All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 62196-2:2012 E


BS EN 62196-2:2012
62196-2:2012+A12:2014

BS EN 62196-2:2012
62196-2:2012+A11:2013
EN
62196-2:2012
BS EN
62196-2:2012
EN
62196-2:2012+A12:2014
62196-2:2012+A11:2013
EN
62196-2:2012
BS EN
62196-2:2012
EN 62196-2:2012
EN 62196-2:2012

-2-––22- ––
-2-2-

Foreword
Foreword
Foreword
The text of document 23H/267/FDIS, future edition
1 of IEC 62196-2, prepared by SC 23H, "Industrial
Foreword

The
text
document 23H/267/FDIS,
future

edition 1accessories"
of IEC 62196-2,
prepared by
"Industrial
plugs
andof
of IEC TC 23,
"Electrical
was submitted
to SC
the 23H,
IEC-CENELEC
The text
ofsocket-outlets",
document 23H/267/FDIS,
future
edition 1 of IEC 62196-2,
prepared by
SC
23H,
"Industrial
plugs
and
socket-outlets",
of
IEC
TC
23,
"Electrical
accessories"

was
submitted
to
the
IEC-CENELEC
The
ofsocket-outlets",
document
23H/267/FDIS,
future
edition
1accessories"
of IEC 62196-2,
prepared by
"Industrial
parallel
vote
and approved
by
as
EN
62196-2:2012.
plugstext
and
of CENELEC
IEC TC 23,
"Electrical
was submitted
to SC
the 23H,

IEC-CENELEC
parallel
votesocket-outlets",
and approved by
CENELEC
as
EN 62196-2:2012.
plugs
and
of
IEC
TC
23,
"Electrical
accessories"
was
submitted
to
the
IEC-CENELEC
parallel vote and approved by CENELEC as EN 62196-2:2012.
parallel vote and approved by CENELEC as EN 62196-2:2012.
The following dates are fixed:
The following dates are fixed:
The following dates are fixed:
The
following
are fixed:
(dop)
2012-11-01

• latest
datedates
by which
the document has
(dop)
2012-11-01
• to
latest
date
by
which
the
document
be implemented
national
levelhas
by
(dop)
2012-11-01
• latest
date by whichatthe
document
has
be
implemented
at
national
level
by
(dop)

2012-11-01
• to
latest
date
by
which
the
document
has
publication
of an identical
national
to
be implemented
at national
level by
publication
of
an
identical
national
to
be
implemented
at
national
level
by
standard orof
byan

endorsement
publication
identical national
byan
endorsement
publication
of
identical
national
(dow)
2015-02-01
• standard
latest dateor
the national
standard
orby
bywhich
endorsement
(dow)
2015-02-01
• standard
latest dateorconflicting
by
which
the
national
by
endorsement
standards
with

the
(dow)
2015-02-01
• latest date by which the national
standards
conflicting
with
the
(dow)
2015-02-01
• document
latest date conflicting
by which
national
have
to bethe
withdrawn
standards
with
the
document
have to be with
withdrawn
standards
conflicting
the
document have to be withdrawn
document have to be withdrawn
EN 62196-2 is to be read in conjunction with EN 62196-1. The clauses of the particular requirements in
EN

62196-2
is to be
in the
conjunction
with EN
62196-1.
The1.clauses
of the
in
Part
2 supplement
or read
modify
corresponding
clauses
in Part
Where the
textparticular
indicates requirements
an "addition" to
EN 62196-2
is to be
read
in conjunction
with EN
62196-1.
The clauses
of the
particular
requirements

in
Part
2
supplement
or
modify
the
corresponding
clauses
in
Part
1.
Where
the
text
indicates
an
"addition"
to
EN
is to be
in the
conjunction
with EN
62196-1.
The1.clauses
of the
in
or a62196-2
"replacement"

of read
the relevant
requirement,
test
specification
or explanation
of
Part 1,requirements
these
changes
Part
2 supplement
or
modify
corresponding
clauses
in Part
Where
the
textparticular
indicates
an
"addition"
to
or
"replacement"
of modify
the relevant
requirement,
test specification

or of
explanation
Part
1, an
these
changes
Part
2 supplement
or
in Part 1.
Where
text of
indicates
"addition"
to
area
to the relevant
textthe
ofcorresponding
Part
1, which clauses
then
becomes
part
thethe
standard.
Where
no
change
is

or
a made
"replacement"
of the relevant
requirement,
test specification
or explanation
of
Part
1, these
changes
are
made
to
the
relevant
text
of
Part
1,
which
then
becomes
part
of
the
standard.
Where
no
change

is
or
a
"replacement"
of
the
relevant
requirement,
test
specification
or
explanation
of
Part
1,
these
changes
necessary,
words
"Thistext
clause
of Part
1 is applicable"
are used.
are
made tothe
the
relevant
of Part
1, which

then becomes
part of the standard. Where no change is
necessary,
the
words
"Thistext
clause
of Part
1 is applicable"
are used.
are
made
to
the
relevant
of
Part
1,
which
then
becomes
part
of
the
standard.
Where
no
change
is
necessary, the words "This clause of Part 1 is applicable" are used.

This standard
the Principle
the Safetyare
Objectives
for Electrical Equipment Designed
necessary,
thecovers
words "This
clause ofElements
Part 1 is of
applicable"
used.
This
standard
covers the
Principle
Elements
of the Safety Objectives for Electrical Equipment Designed
for
Use
within
Certain
Voltage
Limits
(LVD
2006/95/EC).
This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed
for
Use
within Certain

Voltage
LimitsElements
(LVD - 2006/95/EC).
This
standard
covers the
Principle
of the Safety Objectives for Electrical Equipment Designed
for Use
within Certain
Voltage
Limits (LVD - 2006/95/EC).
for
Use
within
Certain
Voltage
Limits
(LVD
2006/95/EC).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
Attention
is drawn
to the[and/or
possibility
that
some
elements
of this
beall

the subject
of
patent
rights.
CENELEC
CEN]
shall
not of
bethe
held
responsible
for document
identifying may
any or
patent
Attention
is drawn
to the possibility
that
some
of
the
elements
of this
document
may
be thesuch
subject
of
patent

rights.
CENELEC
[and/or
CEN]
shall
not of
bethe
held
responsible
for document
identifying may
any or
all
such
patent
Attention
is
drawn
to
the
possibility
that
some
elements
of
this
be
the
subject
of

rights.
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent
rights.
patent
rights.
CENELEC
[and/or
CEN]
shall
not
be
held
responsible
for
identifying
any
or
all
such
patent
rights.
rights.

Endorsement notice
Endorsement notice
Endorsement
notice
EN 62196-2:2012/A11:2013
–2–
The text of the International StandardEndorsement

IEC 62196-2:2011notice
was approved by CENELEC as a European
The
text of
the International
Standard IEC 62196-2:2011 was approved by CENELEC as a European
Standard
without
any modification.
The text of
the International
Standard IEC 62196-2:2011 was approved by CENELEC as a European
Standard
without
any modification.
The
text
of
the
International
Standard IEC 62196-2:2011 was approved by CENELEC as a European
Standard without any modification.
Standard without any modification.

ForewordForeword
to amendment A11

This document (EN 62196-2:2012/A11:2013) has been prepared by CLC/TC 23BX "Switches, boxes
and enclosures for household and similar purposes, plugs and socket outlets for d.c. and for the
charging of electrical vehicles including their connectors".

The following dates are fixed:


latest date by which this document has to be implemented
at national level by publication of an identical national
standard or by endorsement

(dop)

2013-10-15



latest date by which the national standards conflicting with
this document have to be withdrawn

(dow)

2017-10-15

Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association.
This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment
Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC).


EN 62196-2:2012/A12:2014


–3–
-2-

BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

Foreword Foreword
to amendment A12
This document (EN 62196-2:2012/A12:2014) has been prepared by CLC/TC 23BX "Switches, boxes
and enclosures for household and similar purposes, plugs and socket outlets for d.c. and for the
charging of electrical vehicles including their connectors".
The following dates are fixed:




latest date by which this document has to be
implemented at national level by publication of
an identical national standard or by
endorsement
latest date by which the national standards
conflicting with this document have to
be withdrawn

(dop)

2015-06-16

(dow)


2017-06-16

This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment
Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
__________


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

–4
3 ––
-3-

BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
EN 62196-2:2012

Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD
applies.

Addition to Annex ZA of EN 62196-1:2012:
Publication

Year

Title

EN/HD

Year

IEC 60068-2-14

-

Environmental testing Part 2-14: Tests - Test N: Change of
temperature

EN 60068-2-14

-


BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
EN 62196-2:2012/A11:2013


5–
–– 4
–4–



BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

Annex ZB
(normative)

Special national conditions
Special national condition: National characteristic or practice that cannot be changed even over a
long period, e.g. climatic conditions, electrical earthing conditions.
NOTE If it affects harmonization, it forms part of the European Standard / Harmonization Document.

For the countries in which the relevant special national conditions apply these provisions are
normative, for other countries they are informative.
Clause

Special national condition

6.1

United Kingdom
Mode 1 will not be used in the United Kingdom.

10.101


France
nd

Add a 2 paragraph: When plugs & socket-outlets are used and socket-outlets are
accessible to uninstructed persons, they shall be provided with shutters (as presently
defined in Type 3).
10.101

Portugal
Shutters are compulsory on live (phase and neutral) contact holes of socket-outlets and
connectors not exceeding 16 A when these accessories are accessible to uninstructed
persons (ordinary persons BA1, handicapped persons BA2 or children BA3).
In locations with restricted access to skilled persons, socket-outlets and connectors
without shutters may be accepted.


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

–5–
–6
5 ––
–2–
–2–

BS EN 62196-2:2012+A11:2013
BS EN
EN 62196-2:2012+A11:2013
62196-2:2012+A11:2013
BS EN 62196-2:2012

EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2
 IEC:2011
62196-2  IEC:2011

CONTENTS
CONTENTS
FOREWORD ........................................................................................................................... 7
4
FOREWORD
...........................................................................................................................
4
7
INTRODUCTION
..................................................................................................................... 8
6
9

9
INTRODUCTION
.....................................................................................................................
6
10
1 Scope ...............................................................................................................................
7
1
2

10

9
Scope
...............................................................................................................................
7
Normative
references .......................................................................................................

2
3

10
11
Normative
7
Terms and references
definitions .......................................................................................................
8

3
4

11
Terms
definitions .......................................................................................................10
8
Generaland
............................................................................................................................

4
5


11
General
............................................................................................................................10
Ratings .............................................................................................................................
8

5
6

11
Ratings
.............................................................................................................................
8
Connection
between the power supply and the electric vehicle .........................................10

6
7

13
Connection
between
the power
supply and the electric vehicle .........................................
8
14
Classification
of accessories
..........................................................................................

11

7
8

13
Classification
of accessories .......................................................................................... 14
11
Marking ..........................................................................................................................

8
9

13
Marking
..........................................................................................................................
11
Dimensions
.................................................................................................................... 14

9
....................................................................................................................
11
10 Dimensions
Protection against
electric shock .................................................................................... 14
12
15


14
10
against
....................................................................................
11 Protection
Size and colour
of electric
earthingshock
conductors
........................................................................... 15
12
14
11
and colour
of earthing
conductors ........................................................................... 15
12 Size
Provision
for earthing
.....................................................................................................
12
14
12
earthing ..................................................................................................... 15
12
13 Provision
Terminals for
.......................................................................................................................
13
12

16
14 Terminals
Interlocks ....................................................................................................................... 15
13

15
14
13
15 Interlocks
Resistance.......................................................................................................................
to ageing of rubber and thermoplastic material ............................................. 16
15
15
to ageing ......................................................................................................
of rubber and thermoplastic material ............................................. 16
16 Resistance
General construction
13
15
16
construction
......................................................................................................
13
17 General
Construction
of socket-outlets
........................................................................................ 16
15
17
........................................................................................

18 Construction of socket-outlets
plugs and vehicle
connectors ................................................................. 16
13
15
18
plugs and
vehicle
connectors ................................................................. 16
13
19 Construction of vehicle
inlets
..........................................................................................
15
19
of vehicle.....................................................................................................
inlets .......................................................................................... 16
13
20 Construction
Degrees of protection
15
20
protectionand
.....................................................................................................
21 Degrees
Insulationofresistance
dielectric strength ................................................................... 16
13
15
21

resistance
and dielectric strength ................................................................... 16
22 Insulation
Breaking capacity
...........................................................................................................
13
17
22
capacity............................................................................................................
........................................................................................................... 16
13
23 Breaking
Normal operation
14
16
23
operation
24 Normal
Temperature
rise ............................................................................................................ 17
14
16
24
rise
............................................................................................................
25 Temperature
Flexible cables
and
their connection ............................................................................... 17
14

16
25
cables
and their
connection ............................................................................... 17
14
26 Flexible
Mechanical
strength
.......................................................................................................
18
26
strength .......................................................................................................
14
27 Mechanical
Screws, current-carrying
parts and connections .............................................................. 17
15
17
27
current-carrying
parts and
connections
15
28 Screws,
Creepage
distances, clearances
and
distances .............................................................. 18
17

28
distances
.............................................................. 18
29 Creepage
Resistancedistances,
to heat, toclearances
fire and to and
tracking
.......................................................................
15
17
29
to heat,
to fireto
and
to tracking
....................................................................... 18
15
30 Resistance
Corrosion and
resistance
rusting
................................................................................
17
30
resistancecurrent
to rusting
................................................................................
31 Corrosion
Conditionaland

short-circuit
withstand
test ............................................................... 18
15
17
31
short-circuit
current
withstand
test ............................................................... 18
32 Conditional
Electromagnetic
compatibility
(EMC)
..............................................................................
15
17
32
(EMC) .............................................................................. 18
33 Electromagnetic
Vehicle driveovercompatibility
............................................................................................................
15
17
33
driveover
............................................................................................................ 18
101 Vehicle
Components
...................................................................................................................

15
19
101
...................................................................................................................
15
102 Components
Coding resistors
............................................................................................................. 18
16
102 Coding resistors ............................................................................................................. 19
16
Table 101 – Overview of the basic vehicle interface, configuration Type 1, single
12
13
phase
...................................................................................................................................
10
Table 101
– Overview of the basic vehicle interface, configuration Type 1, single
phase ................................................................................................................................... 13
10


BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC:2011

7–
–– 6


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

–3–

Table 102 – Overview of the basic vehicle interface, configuration Types 2 and 3,
12
three-phase or single phase .................................................................................................. 13
10

14
Table 103 – Configuration types and standard sheets ........................................................... 15
12


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

–8
9 ––
–6–

BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC:2011

INTRODUCTION
Responding to global challenges of CO 2 reduction and energy security, the automobile

industries have been accelerating the development and commercialization of electric vehicles
and hybrid electric vehicles. In addition to the prevailing hybrid electric vehicles, battery
electric vehicles including plug-in hybrid electric vehicles are going to be mass-marketed. To
support the diffusion of such vehicles, this standard provides the standard interface
configurations of a.c. vehicle couplers and accessories to be used in conductive charging of
electric vehicles, taking the most frequent charging situations into consideration.
IEC 62196 is divided into several parts:
Part 1: General requirements
Part 2: Dimensional compatibility and interchangeability requirements for a.c. pin and contacttube accessories
Part 3: Dimensional compatibility and interchangeability requirements for pin and contact-tube
accessories for dedicated d.c. charging or for combined a.c./d.c.charging (under
consideration)


BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC:2011

9 ––
––10

BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

–7–

PLUGS, SOCKET-OUTLETS, VEHICLE CONNECTORS
AND VEHICLE INLETS –
CONDUCTIVE CHARGING OF ELECTRIC VEHICLES –

Part 2: Dimensional compatibility and interchangeability requirements
for a.c. pin and contact-tube accessories

1

Scope

This standard applies to plugs, socket-outlets, vehicle connectors and vehicle inlets with pins
and contact-tubes of standardized configurations, herein referred to as accessories. They
have a nominal rated operating voltage not exceeding 500 V a.c., 50 to 60 Hz, and a rated
current not exceeding 63 A three-phase or 70 A single phase, for use in conductive charging
of electric vehicles.
This standard covers the basic interface accessories for vehicle supply as specified in
IEC 62196-1, and intended for use in conductive charging systems for circuits specified in
IEC 61851-1:2010.
Electric vehicles covers all road vehicles, including plug-in hybrid road vehicles (PHEV), that
derive all or part of their energy from on-board batteries.
NOTE 1

These accessories may provide a contact that can be used for the proximity contact function.

These accessories are intended to be used for circuits specified in IEC 61851-1:2010 which
operate at different voltages and frequencies and which may include ELV and communication
signals.
These accessories may be used for bidirectional energy transmission (under consideration).
This standard applies to the accessories to be used in an ambient temperature of between
– 30 °C and + 50 °C.

text
 country, other requirements may apply: FI.

NOTE
2 deleted
In the following
These accessories are intended to be connected only to cables with copper or copper-alloy
conductors.
Vehicle inlet and vehicle connector to this standard are intended to be used for charging in
modes 1, 2 and 3, cases B and C. The socket-outlets and plugs covered by this standard are
intended to be used for charging mode 3 only, case A and B.
The modes and permissible connections are specified in Part 1.

2

Normative references

This clause of Part 1 is applicable except as follows:
Addition:
IEC 60068-2-14, Environmental testing – Part 2-14: Tests – Test N: Change of temperature


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

– 10
11 ––
–8–

3

BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013

BS EN 62196-2:2012
62196-2  IEC:2011

Terms and definitions

This clause of Part 1 is applicable.

4

General

This clause of Part 1 is applicable, except as follows:
Addition at the end of the subclause:
Accessories according to this standard are intended for modes 1, 2 and 3, cases A to C. The
socket-outlets and plugs covered by this standard shall be used only in mode 3.

5

Ratings

This clause of Part 1 is applicable except as follows:
5.1 Replacement:
Rated operating voltage range:
0 to 30 V (signal or control purposes only);
200 to 250 V a.c.
380 to 480 V a.c.
5.2 Replacement:
2 A (signal or control purposes only)
13 A single phase
16 A single and three-phase

20 A single and three-phase
30-32 A single and three-phase
60-63 A single and three-phase
70 A single phase, only
NOTE
the following

textIndeleted
 countries, the branch circuit overcurrent protection device is based upon 125 % of the
accessory rating: US.

6

Connection between the power supply and the electric vehicle

This clause of Part 1 is applicable except as follows:
6.1 Replacement:
This section provides a description of the physical conductive electrical interface
requirements between the vehicle and the power supply, which allows the following design at
the vehicle interface:
a basic interface that provides for current ratings up to 63 A a.c. three-phase and up to 70 A
a.c. single phase.
Different configuration types for the basic interface may allow different application of mode
and current ratings. See introduction to relevant standard sheets for more details.


BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC:2011


11 ––
–– 12

BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

–9–


textIndeleted
 country, Mode 1 will not be allowed: UK.
NOTE
the following
6.2 Replacement:
There shall be the following type of vehicle inlets:
basic
6.3 Replacement:
There shall be the following type of vehicle connectors:
basic
6.4 Not applicable
6.5 Replacement:
The basic interface may contain up to 7 power or signal contacts, with unique physical
configurations of contact positions for single or three phases. The electrical ratings and their
function are described in Table 101. The electrical ratings and their function are described in
the Standard Sheets.
Each vehicle inlet shall only mate with the corresponding type of vehicle connector. Each plug
shall only mate with the corresponding type of socket-outlet.
The accessories, configuration Types 1, 2 or 3 are rated as follows:



configuration Type 1 vehicle coupler is rated 250 V, 32 A single phase;



configuration Type 2 vehicle coupler, socket-outlet and plug are rated:







250 V, 13 A or 20 A or 32 A or 63 A or 70 A single phase,



380-480 V, 13 A or 20 A or 32 A or 63 A, three-phase.

configuration Type 3 vehicle coupler is rated:


250 V, 16 A or 32 A, single phase,



380-480 V, 32 A, or 63 A three-phase.

Configuration Type 3 socket-outlet and plug are rated:



250 V, 16 A or 32 A single phase,



380-480 V, 32 A, or 63 A three-phase.


BS EN 62196-2:2012
BS EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
12
–– 13
EN 62196-2:2012+A11:2013
– 10
– ––
62196-2  IEC:2011
BS EN 62196-2:2012
– 10 –
62196-2
 IEC:2011

10

62196-2
 IEC:2011
Table 101 – Overview of the basic vehicle interface,
Table 101
– Overview of
the 1,

basic
vehicle
interface,
configuration
Type
single
phase
configuration
Type
single
phase
Table 101
– Overview of
the 1,
basic
vehicle
interface,
a
c
a.c.
Position number
configuration
Type 1, single phase Functions

BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

a

c


a.c.
Position number
Functions
L1 (mains 1)
1
250 V 32 A b
a
c
a.c.
Position 1number
Functions
b
L1
(mains 1)
250 V 32 A
2
250 V 32 A
L2 (mains 2)/N(neutral)
250VV
V 32
32AA
Ab
1
250
L1 (mains
1)
2
250
32

L2 (mains
2)/N(neutral)
3
Rated for fault
PE (ground/earth)
2
250 Vfor32
A
L2 PE
(mains
2)/N(neutral)
3
Rated
fault
(ground/earth)
4
30 V 2 A
CP (Control pilot)
3
Rated
PE
4
30 Vfor2fault
A
CP (ground/earth)
(Control pilot)
5
30 V 2 A
CS (Connection)
4

30
V
2
A
CP
(Control
pilot)
5
30 V 2 A
CS (Connection)
a
Position number does not refer to the location and/or identification of the contact in the
a
accessory.
V location
2A
CS (Connection)
Position 5number does not refer to30the
and/or identification
of the contact in the
b
accessory.
a
In the following
branch
circuit
overcurrent
protection is based
125in%the
of

Position
numbercountries,
does not the
refer
to the
location
and/or identification
of the upon
contact
b
the
device
rating:countries,
USA.
accessory.
In
the
following
the branch circuit overcurrent protection is based upon 125 % of
cb
the
device
rating: and
USA.5, environmental conditions may demand larger conductor crossNote
deleted
Forthe
contacts
In
following4 countries,
the branch circuit overcurrent protection is based upon 125 % of

c
sections.
the
rating:
USA.5, environmental conditions may demand larger conductor crossFor device
contacts
4 and
sections.
c
For contacts 4 and 5, environmental conditions may demand larger conductor crosssections.

Table 102 – Overview of the basic vehicle interface,
Table 102 –Types
Overview
of 3,
the
basic vehicle
interface,
configuration
2 and
three-phase
or single
phase
configuration
Types
2
and
3,
three-phase
or

single
phase
Table 102 – Overview of the basic vehicle interface,
Three phase
Single phaseor single phase
configuration
Types 2 and 3, three-phase

Three phase
Single phase
a
a
I max
I max
Three phase a
Single
phase
a
Functions
I max
I max
I max
I max
A a
A a
Functions
I max
I max
A
A

Functions
f
Type 2
Type 3
Type 2 b
Type 3
number
V a.c.
A
A
b
Type 2
Type 3
Type 2
Type 3
b
1
480
63
70
63
L1 (mains 1)
Type 2
Type 3
Type 2 b
Type 3
b
1
480
63

70
63
L1 (mains 1)
c
c
2
480
63
L2 (mains 2)b
1
480
63
70
63
L1 (mains 1)
c
c
2
480
63
L2 (mains 2)
c
c
c
c
3
480
63
L3
2

480
63
L2 (mains
(mains 3)
2)
-c
-c
3
480
63
L3 (mains 3)
b, e
4
480
63
70
63
NL3(neutral)
3
480
63
(mains 3)
-c
-c
b, e
4
480
63
70
63

N (neutral)
5

Rated for fault
PE (ground/earth)
b, e
4
480
63
70
63
N (neutral)
5

Rated for fault
PE (ground/earth)
6
30
2
CP (Control pilot)
5

Rated for fault
PE (ground/earth)
6
30
2
CP (Control pilot)
PP (Proximity) d or
7

30
2
d
6
30
2
CP
(Control pilot)
d
CS PP
(Connection
switch)
or
(Proximity)
7
30
2
d
CS (Connection switch)
d
a
or
PP125
(Proximity)
In7 the following
countries,
the
branch
circuit
overcurrent

protection
is
based
upon
%
of
the
device
30
2
CS (Connection switch) d
a
rating:
USA.
Note
In thedeleted
following
countries, the branch circuit overcurrent protection is based upon 125 % of the device
b
rating:
USA.
a
Forthe
single
phase countries,
charging, contacts
1 and
4 shall
be used. protection is based upon 125 % of the device
In

following
the branch
circuit
overcurrent
b
rating:
USA.
c
For
single
phase
charging,
contacts
1
and
4
shall
be used.
Unused contacts need not to be installed. Not provided
for standard sheets 2-IIIa and 2-IIIb.
Position
f
number
Position
f
number
Position

b
c

d
c
d
e
d
e
f
fe
f

U max
U max
V a.c.
U
V max
a.c.

For
single
phase charging,
contacts
1 and Not
4 shall
be used.
Unused
contacts
need not sheet
to
be 2-IIIa.
installed.

provided
for standard sheets 2-IIIa and 2-IIIb.
Not
provided
for standard
Unused
contacts
need not sheet
to be 2-IIIa.
installed. Not provided for standard sheets 2-IIIa and 2-IIIb.
Not
provided
for
standard
For single phase system supply phase to phase this contact can be used for L2 (mains 2).

Not
provided
for standard
sheet phase
2-IIIa. to phase this contact can be used for L2 (mains 2).
For single
phase
system
Position
number
does
notsupply
refer to
the location and/or identification of the contact in the accessory

For single
phase does
system
phase
to phase
this contact
can beofused
for L2 (mains
Position
number
notsupply
refer to
the location
and/or
identification
the contact
in the 2).
accessory
Position number does not refer to the location and/or identification of the contact in the accessory

6.6 This subclause of Part 1 is not applicable.
6.6 This subclause of Part 1 is not applicable.
6.6 This
subclause of Part
is not applicable.
6.101
Communication
and1 control
pilot function
6.101 Communication and control pilot function

The
pilot and proximity
detection,
connection contacts shall be used in accordance
6.101control
Communication
and control
pilotorfunction
The control
pilot and proximity detection, or connection contacts shall be used in accordance
with
IEC 61851-1:2010.
with
IEC 61851-1:2010.
The control
pilot and proximity detection, or connection contacts shall be used in accordance
with IEC 61851-1:2010.


BS EN 62196-2:2012+A11:2013
EN
BS 62196-2:2012+A11:2013
EN 62196-2:2012
BS EN 62196-2:2012
62196-2  IEC:2011
62196-2  IEC:2011

7
7


13 ––
–– 14

BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

– 11 –
– 11 –

Classification of accessories
Classification of accessories

This clause of Part 1 is applicable except as follows:
This clause of Part 1 is applicable except as follows:
7.4
Replacement:
7.4
Replacement:
According to electrical operation
According to electrical operation
– Suitable for making and breaking an electrical circuit
– Types
Suitable
for 3making
and
1 and
up to 32
A; breaking an electrical circuit
Types 1 and 3 up to 32 A;
– Not suitable for making and breaking an electrical circuit

– Type
Not suitable
and
breaking
electrical
2 rated for
63 making
A and 70
A and
Type an
3, rated
63 A.circuit
Type 2 rated 63 A and 70 A and Type 3, rated 63 A.
NOTE
NOTE

under load for configuration
under load for configuration
under load for configurations
under load for configurations

Communication circuits to this standard are deemed not to make or break load in the purpose of this clause.
Communication circuits to this standard are deemed not to make or break load in the purpose of this clause.

7.5
Replacement:
7.5
Replacement:
According to the function as specified in Clause 6
According to the function as specified in Clause 6

– Basic type only.
– Basic type only.
Addition:
Addition:
7.101
7.101







8
8

According to the Standard Sheet used
According to the Standard Sheet used
Configuration Type 1;
Configuration Type 1;
Configuration Type 2;
Configuration Type 2;
Configuration Type 3.
Configuration Type 3.

Marking
Marking

This clause of Part 1 is applicable.
This clause of Part 1 is applicable.


9
9

Dimensions
Dimensions

This clause of Part 1 is applicable except as follows:
This clause of Part 1 is applicable except as follows:
9.1 Replacement:
9.1 Replacement:
Accessories shall comply with the relevant standard sheets as specified below and in Table
Accessories shall comply with the relevant standard sheets as specified below and in Table
103:
103:
Configuration Type 1
Configuration Type 1
– Vehicle couplers not exceeding 250 V, 32 A single phase: standard sheet 2-I.
– Vehicle couplers not exceeding 250 V, 32 A single phase: standard sheet 2-I.
– Optional locking system: standard sheet 2-Ia.
– Optional locking system: standard sheet 2-Ia.
NOTE

In the USA, the standard sheets 2-I and 2-Ia may be applied to vehicle couplers with rated current up to

NOTE
the USA,
the standard sheets 2-I and 2-Ia may be applied to vehicle couplers with rated current up to

80

A.textIndeleted
80 A.

Configuration Type 2
Configuration Type 2

Accessories not exceeding 480 V, 63 A three-phase or 70 A single phase: standard

Accessories
notIIb,
exceeding
480IIf,V,IIg63and
A three-phase
or 70 A single phase: standard
sheets
2-II, IIa,
IIc, IId, IIe,
IIh.
sheets 2-II, IIa, IIb, IIc, IId, IIe, IIf, IIg and IIh.
Configuration Type 3
Configuration Type 3
– Accessories not exceeding 250 V, 16 A single phase, one pilot: standard sheet 2-IIIa;
– Accessories not exceeding 250 V, 16 A single phase, one pilot: standard sheet 2-IIIa;
– Accessories not exceeding 250 V, 32 A single phase, two pilots: standard sheet 2-IIIb;
– Accessories not exceeding 250 V, 32 A single phase, two pilots: standard sheet 2-IIIb;


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014


14 ––
–– 15

BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012

– 12 –

62196-2  IEC:2011



Accessories not exceeding 480 V, 63 A three phase, two pilots: standard sheet 2-IIIc;



Retaining means and packaging room: standard sheet 2-IIId.
Table 103 – Configuration types and standard sheets

Configuration
Type

Standard Sheet

Applicable
accessories

Rated voltage
V


Rated
current
A

Phase

1

2-I

Vehicle couplers

Not exceeding 250

32

Single-phase

70

Single-phase

2

2-II

Accessories

Not exceeding 480

63

Three-phase

Not exceeding 250

16

Single-phase

Not exceeding 250

32

Single-phase

Not exceeding 480

63

Three-phase

3

2-III

Accessories

10 Protection against electric shock
This clause of Part 1 is applicable except as follows:

Addition:
10.101 Accessories of configuration Type 3 shall be provided with shutters. Accessories of
other configuration types may be provided with shutters.
Compliance is checked by inspection.

11 Size and colour of earthing conductors
This clause of Part 1 is applicable except as follows:
Replacement:
The core connected to the earthing terminal shall be identified by the colour combination
green-and-yellow. The nominal cross/sectional area of the earthing conductor and of the
neutral conductor, if any, shall be at least equal to that of the phase conductors.
NOTE
the following

textIndeleted
 countries, the colour green may be used to identify the earthing conductor: JP, USA, CA.

12 Provision for earthing
This clause of Part 1 is applicable.

13 Terminals
This clause of Part 1 is applicable.


BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC:2011

15 ––

–– 16

BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

– 13 –

14 Interlocks
This clause of Part 1 is applicable for configuration Type 1.
Addition for configuration Types 2 and 3:
Accessories shall be provided with a latching device according to standard sheets 2-II or 2IIId to prevent the connection to be separated unintentionally or by unauthorized persons.
The interlock function shall be performed by the proper functioning of the latching device.
A means shall be provided to indicate that the interlock is properly engaged.
Compliance is checked by inspection and manual test.

15 Resistance to ageing of rubber and thermoplastic material
This clause of Part 1 is applicable.

16 General construction
This clause of Part 1 is applicable.

17 Construction of socket-outlets
This clause of Part 1 is applicable

18 Construction of plugs and vehicle connectors
This clause of Part 1 is applicable.

19 Construction of vehicle inlets
This clause of Part 1 is applicable.


20 Degrees of protection
This clause of Part 1 is applicable.

21 Insulation resistance and dielectric strength
This clause of Part 1 is applicable.

22 Breaking capacity
This clause of Part 1 is applicable.


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

16 ––
–– 17
– 14 –

BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC:2011

23 Normal operation
This clause of Part 1 is applicable.

24 Temperature rise
This clause of Part 1 is applicable except as follows:
24.1 Addition after the seventh paragraph:
For accessories dependent upon a coding resistor to establish the accessory’s assigned
current rating, the test shall be repeated using a set of samples for each coding resistor value

and tested at the maximum current corresponding to that coding resistor value.

25 Flexible cables and their connection
This clause of Part 1 is applicable.

26 Mechanical strength
This clause of Part 1 is applicable except as follows.
Addition:
26.101
Isolating caps, if any, shall be fixed sufficiently to the contact pins so that they
withstand the mechanical force and abuse to which the accessories may be exposed in
normal use. They shall be subjected to the tests of 26.103 and 26.104.
26.102

After each of the following tests, the samples shall show no damage as follows:



no part shall become detached;



no part shall have moved, loosened or deformed to the extent that the samples no longer
function or operate as intended.



no uninsulated live part shall become accessible with the probe illustrated in Part 1,
Figure 2.




no reduction shall occur of creepage and clearance between uninsulated live parts of
opposite polarity, uninsulated live parts and accessible dead or grounded metal parts,
below the minimum acceptable values.



no other evidence of damage shall result, that could increase the risk of fire or electric
shock.

26.103

Change of temperature test

Accessories with isolating caps on the contacts shall not be adversely affected by the
temperature stress conditions which may occur in normal use.
Compliance is checked by conditioning the accessories, while mated with their
complementary accessory, as specified in this subclause. Test specimens of the largest and
smallest size caps shall be tested.
The specimens are mated with their complimentary accessory and subjected to the change of
temperature test of IEC 60068-2-14 with following parameters:


Test procedure

Nb


BS EN 62196-2:2012+A11:2013

EN 62196-2:2012+A11:2013
BS EN 62196-2:2012

17 ––
–– 18

62196-2  IEC:2011

BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

– 15 –



Lower temperature

TA

-30 °C



Higher temperature

TB

+100 °C




Slew rate

3 K/min



Exposure time

t1



Number of cycles

5

1h

26.104 A set of six contact assemblies with isolating caps shall be subjected to a pull test. A
force of 20 N is applied for 1 min and it shall be applied in a direction opposite from the pin or
contact, along the pin or contact axis. The pulling force shall be applied in a way where it
causes no effect on the fixing area of the part.
NOTE

The force can be applied by a drilling in the isolated cap, rectangular to the pin axis, close to the end.

27 Screws, current-carrying parts and connections
This clause of Part 1 is applicable.


28 Creepage distances, clearances and distances
This clause of Part 1 is applicable.

29 Resistance to heat, to fire and to tracking
This clause of Part 1 is applicable.

30 Corrosion and resistance to rusting
This clause of Part 1 is applicable.

31 Conditional short-circuit current withstand test
This clause of Part 1 is applicable.

32 Electromagnetic compatibility (EMC)
This clause of Part 1 is applicable.

33 Vehicle driveover
This clause of Part 1 is applicable except as follows:
33.3

Not applicable

33.4.

Not applicable

101 Components
101.1

Ratings


A component shall be used in accordance with its rating established for the intended
conditions of use.


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

18 ––
–– 19
– 16 –

BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC:2011

Compliance is checked by inspection.
101.2

Mechanical assembly

Loosening of parts in an accessory as a result of vibration due to storage, handling and
operation shall not result in a risk of fire, electric shock, injury to persons, or electrical energy
– high current levels.
Compliance is checked by inspection
101.3

Current-carrying parts

An uninsulated live part, or a component that has uninsulated live parts shall be so secured to

the base or mounting surface, or otherwise insulated that the part does not turn or shift in
position resulting in a reduction of creepage distances, clearances and distances below the
minimum required values of Part 1, Clause 28.
Compliance is checked by inspection.
101.4

Electrical connections

101.4.1 The requirements described in 101.4.2 to 101.4.4 apply to connections of internal
wiring that are factory installed in the accessory.
Compliance is checked by inspection.
101.4.2 A splice or connection shall be mechanically secure and shall make electrical
contact.
Compliance is checked by inspection.
101.4.3

A soldered connection is determined to be mechanically secure when the lead is



wrapped one full turn around a terminal,



bent at a right angle after being passed through an eyelet or opening, except on printed
wiring boards where components are inserted or secured (as in a surface-mounted
component) and wave- or lap-soldered, or




twisted with other conductors.

Compliance is checked by inspection.
101.4.4 A splice shall be provided with insulation equivalent to that of the wires involved
unless permanent clearance and creepage distances are maintained between the splice and
other metal parts. Insulation over the splice is not prohibited from having


a splicing device such as a pressure wire connector, having suitable voltage and
temperature ratings;



insulating tubing or sleeving used to cover a splice.

Compliance is checked by inspection.

102 Coding resistors
The vehicle connector and plug of configurations Type 2 and Type 3b and 3c shall be
provided with a coding resistor (R c ) to define the maximum current capability of the cable
assembly and vehicle connector and plug.


BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC:2011

19 ––
–– 20


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

– 17 –

The resistor values and tolerances shall be as specified in IEC 61851-1:2010, Clause B.5,
"System for simultaneous proximity detection and current coding for vehicle connectors and
plugs" .
Compliance is checked by inspection.

___________


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

20 ––
–– 21

BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012

– 34
18 –

STANDARD SHEETS 2-I –
CONFIGURATION TYPE 1


62196-2  IEC/CEI:2011

FEUILLES DE NORME 2-I –
CONFIGURATION TYPE 1

32 A VEHICLE COUPLER HAVING
RATED OPERATING VOLTAGES UPTO
250 V A.C.

CONNECTEUR 32 A AVEC TENSIONS DE
SERVICE ASSIGNEES
JUSQU’A 250 V C.A.

Overview

Vue d'ensemble

The standard sheets 2-I apply to
configuration Type 1 vehicle couplers for
operating voltages up to 250 V a. c. and
operating currents up to 32 A single phase.

Les feuilles de norme 2-I s’appliquent aux
connecteurs de véhicules de configuration
de Type 1 pour des tensions de service
jusqu’à 250 V c.a. et des courants de
fonctionnement jusqu’à 32 A monophasé.

For configuration Type 1, Annex A "Pilot
function through a control pilot circuit using

PWM modulation and a control pilot wire"
and Clause B.2 "Circuits diagrams for
mode 1, mode 2 and mode 3, using a basic
single
phase
vehicle
coupler"
of
IEC 61851-1 shall be applied. +V d.c. of
Table B.2 of IEC 61851-1:2010 shall be a
+5 V regulated supply.

Pour la configuration de Type 1, l’Annexe
A (Fonction pilote à travers un circuit pilote de
contrôle utilisant une modulation de largeur
d’impulsion (PWM) et un fil pilote) et l’Article
B.2 (schéma de circuit pour modes de charge
1, 2 et 3, utilisant la prise mobile monophasée
basique) de la CEI 61851-1 doivent
s’appliquer. +V DC du Tableau B.2 de la
CEI 61851-1:2010 doit être à +5V en
alimentation régulée.

The standard sheets 2-Ia
optional locking system.

define

the


Les feuilles de norme 2-Ia définissent le
système de retenue en option.


BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC/CEI:2011

21 ––
–– 22

BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

– 35
19 –

STANDARD SHEET 2-I (Sheet 1)

FEUILLE DE NORME 2-I (Feuille 1)

32 A VEHICLE INLET HAVING RATED
OPERATING VOLTAGES UP TO 250 V A.C.

SOCLE DE CONNECTEUR DE VEHICULE
32 A AVEC TENSIONS DE SERVICE
ASSIGNEES JUSQU’A 250 V A.C.

IEC


2292/11


BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

22 ––
–– 23
– 36
20 –

BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC/CEI:2011

STANDARD SHEET 2-I (Sheet 2)

FEUILLE DE NORME 2-I (Feuille 2)

32 A VEHICLE CONNECTOR HAVING
RATED OPERATING VOLTAGES
UP TO 250 V A.C.

PRISE MOBILE DE VÉHICULE 32 A
AVEC TENSIONS DE SERVICE
ASSIGNEES JUSQU’A 250 V A.C.

(continuation of Sheet 1)


(suite de Feuille 1)

IEC

2293/11


BS EN 62196-2:2012+A11:2013
EN 62196-2:2012+A11:2013
BS EN 62196-2:2012
62196-2  IEC/CEI:2011

23 ––
–– 24

BS EN 62196-2:2012+A12:2014
EN 62196-2:2012+A12:2014

– 37
21 –

STANDARD SHEET 2-I (Sheet 3)
(continuation of Sheet 2)

RETAINING MEANS FOR IP44 VEHICLE
COUPLER AND MAXIMUM DIMENSIONS
OF VEHICLE CONNECTOR BODY
OUTLINE
Latch shown in latched position


FEUILLE DE NORME 2-I (Feuille 3)
(suite de Feuille 2)

DISPOSITIF DE RETENUE D’UN
CONNECTEUR DE VEHICULE IP44
ET DIMENSIONS MAXIMALES DU
CONTOUR DU CORPS DE LA PRISE
MOBILE DE VÉHICULE
Crochet en position fermée

IEC

The sketches are not intended to govern design of
vehicle connector body and latch shape except for the
dimensions shown.

2294/11

Les dessins ne sont pas destinés à définir la conception
du corps de la prise mobile du véhicule et de la forme
du verrou sauf pour les dimensions présentées.


×