0.5 to 125A: Multi 9 circuit breakers
symetrical rail mounting
number of poles
BS EN 61009
MERLIN GERIN
multi 9
DPN vigi
1
N
2
C40 I∆n 0,300A
230Va
4500
1 to 40A
6 to 40A
10 to 40A
0.5 to 63A
DPNa
DPN N
DPN N Vigi
V40H
C60a
C60N
C60H
C60L
1+N
1+N
1+N
1+N
1
1
1
1
32
40
40
40
40
63
63
440
4
230
440
4
230
440
4
230
440
4
240
440
6
440
440
6
440
440
6
440
■
■
■
■
■
■
2-3-4
10 to 100A
2-3-4
2-3-4
2-3-4
1
2-3-4
1
2-3-4
125A
NC100H NC100L
NC100LS NC100LH NC125H
1-2-3-4
1-2-3-4
1-2-3-4
1-2-3-4
3-4
100
440
6
440
63
440
6
440
63
440
6
440
63
440
6
440
125
415
6
415
electrical characteristics
test mensuel
test monthly
N
6 to 32A
a
6 kA IEC 947.2
rated current (A)
20912
In
O - OFF
rated insulation voltage (V)
Ui
impulse withstand voltage (kV)
Uimp
rated operational voltage (V)
Ue
AC 50.60Hz
fast closing
disconnection with positive contact indication
AC breaking capacity (kA rms)
IEC 947.2 (EN 60.947.2)
Icu
130V
240V
400V
415V
440V
Ics
(% of Icu)
IEC 898
Icn
230V
Ics
DC breaking capacity (kA)
IEC 947.2 (EN 60.947.2)
Icu
60V
125V
125V
250V
Ics
(% of Icu)
DPN Vigi
MERLIN GERIN
multi 9
C60N
C63
400Va
6000
1 3
10kA IEC 947.2
24208
O - OFF
30°C
40°C
2 4
O - OFF
C60
10
10
5
3
100%
4.5
4.5
100%
6
6
100%
6
6
15
15
100%
100%
■
■
■
■
■
■
75%
10
5
3
20
10
3
75%
20
10
6
25
440
6
440
32.40
440
6
440
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
20
10
10
6
75%
50
25
25
20
75%
70
36
36
30
75%
80
50
40
30
75%
20
36 (1p)
100%
50 (1p)
100%
■
■
30
15
4
50%
30
15
10
50
25
6
50%
50
25
20
50
20
5
50%
40
20
15
50.63
440
6
440
50
15
4
30
15
10
50%
15
20
25
25
25
20 (1p)
10 (2p)
20 (2p)
25 (2p)
30 (2p)
30 (2p)
30 (2p)
30 (2p)
20 (3p)
30 (3p)
40 (3p)
50 (3p)
50 (3p)
50 (3p)
40 (3p)
25 (4p)
40 (4p)
50 (4p)
60 (4p)
60 (4p)
60 (4p)
20 (4p) 25 (1p)
100%
100%
100%
100%
100%
100%
100%
100%
10
75%
10
trip units (non adjustable)
curve type
MERLIN GERIN
multi 9
NC100H
C100A
415Va
10kA IEC 947.2
27265
1 3
2 4
O - OFF
O - OFF
B (lm = 3.2 to 4.8ln)
C (lm = 7 to 10ln)
D (lm = 10 to 14ln)
K (lm = 10 to 14In)
Z (lm = 2.4 to 3.2)
MA (lm = 12ln)
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■ ≤ 40A
personnel protection
add-on rcd's (Vigi module)
integrated
30-300mA
NC100
electrical auxiliaries
auxiliary and alarm switches (OF-SD)
shunt trip (MX) ; undervoltage release (MN)
integrated
30mA
■
■
■ ≤ 63A
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
installation
plug in base
terminal shieds
padlocking device
rotary handle
dimensions (mm)
2
■
■
W
H
D
18
78
70
■
18
78
70
■
■
36
78
70
36
81
70
Merlin Gerin
Merlin Gerin
■ ≤ 63A
■
■
■
■
■
■
■
■
18/P
81
70
27/P
81
70
3
15 to 600A: Compact
disconnector mouled case circuit breakers
low breaking capacity range: E
225E
P93083
number of poles
15 to 100A
125 to 225A
250 to 400A
C100E
NS225E
NS400E
500 to 600A
NS600E
3
3
3
3
100
500
6
500
225
500
6
500
400
500
6
500
600
500
6
500
30
18
10
8
30
18
15
15
7.5
30
25
25
18
15
30
25
25
18
15
50%
A
III
50%
A
III
50%
A
III
50%
A
III
■
■
■
■
30
8
30
15
30
18
30
18
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
105
128
95
1.3
105
161
86
1.8
140
255
110
6
140
255
110
6
electrical characteristics
MERLIN GERIN
compact
NS225 E
OFF
Ui 550V. Uimp 6kV.
Icu
Ue
(kA)
(V)
85
220/240
36
380/415
35
440
30
500
8
660/690
50
250
cat A
Ics=50% Icu
rated current (A)
rated insulation voltage (V)
rated impulse withstand voltage (kV)
rated operational voltage (V)
In
Ui
Uimp
Ue
40°C
characteristics according to IEC 947.2
rated ultimate breaking capacity
(kA rms)
Icu
AC 50/60Hz
Ics
(% of Icu)
AC 50/60Hz
DC
IEC947-2
UNE NEMA
UTE VDE BS CEI
push
to
trip
Ir
225A
90 %Ir
105
Im
DE 225
225A/48C
alarm
Ir
Im
Compact NS225E
rated service breaking performance
utilisation category
pollution degree
front face insulation class II
rated admissible short time
withstand current
performances according NEMA
rated breaking capacity AB1 (O-CO) (kA)
Icw
220/240V
380V
415V
440V
500V
660/690V
(kA rms)
duration (s)
240V
480V
600V
trip units
thermal magnetic
solid state
protection
for distribution
for motor starters
for people
standard networks
generator fed networks
long distance networks
direct current networks
ELCB's Vigicompact
Vigirex residual current relays
indications and measurement
auxiliary and alarm switches (OF-SD-SDE)
local and/or distance control and monitoring (Dialpact)
data transmission (Dialpact)
voltage presence indicator
current transformer module
ammeter module
insulation monitoring module
control accessories
shunt trip (MX) ; undervoltage release (MN)
direct or extended rotary handles
motor mechanism for remote control
installation
version
accessories
fixed
plug-in on a base
draw-out on chassis
terminal shields
padlocking and locking device
dimensions of 2-3 pole fixed version (mm)
weight (kg)
W
H
D
3 pole fixed version
models
visible break circuit breaker
switch - disconnector
automatic / manual source changeover
4
Visucompact
Merlin Gerin
Merlin Gerin
5
16 to 3200A: Compact
disconnector mouled case circuit breakers
standard range: N
250N
number of poles
P93083
16 to 100A
16 to 160A
16 to 250A
160 to 400A
250 to 630A
320 to 800A
NS100N
NS160N
NS250N
NS400N
NS630N
C801N
400 to 1000A 500 to 1250A 625 to 1250A 800 to 1600A 1000 to 2000A 1250 to 2500A 1600 to 3200A
C1001N
C1251N
CM1250N CM1600N CM2000N CM2500N CM3200N
2-3-4
2-3-4
2-3-4
3-4
3-4
3-4
3-4
3-4
3-4
3-4
3-4
3-4
3
100
750
8
690
160
750
8
690
250
750
8
690
400
750
8
690
630
750
8
690
800
750
8
690
1000
750
8
690
1250
750
8
690
1250
750
8
690
1600
750
8
690
2000
750
8
690
2500
750
8
690
3200
750
8
690
85
25
25
18
8
100%
A
III
85
36
35
30
8
100%
A
III
85
36
35
30
8
100%
A
III
85
45
42
30
10
100%
A
III
85
45
42
30
10
100%
A
III
85
50
42
40
25
50%
B
III
85
50
42
40
25
50%
B
III
85
50
42
40
25
50%
B
III
85
70
65
50
50
50%
B
III
85
70
65
50
50
50%
B
III
85
70
65
50
50
50%
B
III
85
70
65
50
50
50%
B
III
85
70
65
50
50
50%
B
III
■
■
■
■
■
■
■
■
■
■
■
■
■
12
1
15
1
15
1
32
1
32
1
32
1
32
1
32
1
electrical characteristics
MERLIN GERIN
rated current (A)
In
rated insulation voltage (V)
Ui
rated impulse withstand voltage (kV) Uimp
rated operational voltage (V)
Ue
characteristics according to IEC 947.2
rated ultimate breaking capacity
Icu AC 50/60Hz
(kA rms)
compact
NS250 N
OFF
Ui 750V. Uimp 8kV.
Icu
Ue
(kA)
(V)
85
220/240
36
380/415
35
440
30
500
8
660/690
50
250
cat A
Ics=100% Icu
IEC947-2
UNE NEMA
UTE VDE BS CEI
push
to
trip
5
4
.9
.85
.8
.7
.95
3
.98
2
STR 22 SE
alarm
6
8
10
1.5
1
.63
90 %Ir
105
Im
Ir
In=250A
160/250A
Ir
Im
xIr
xIn
for DC consult general catalogue
rated service breaking performance Ics (% of Icu)
utilisation category
pollution degree
front face insulation class II
rated admissible short time
Icw
withstand current
performances according NEMA
rated breaking capacity AB1 (O-CO) (kA)
Compact NS250N
compact
C 1001 H
Ui 750V. Uimp 8kV.
Icu
Ue
(kA)
(V)
OFF
100
70
220/240
380/415
500/525
cat B
Icw 8kA / 0,25s.
Ics = 100% Icu
IEC 947-2
UTE VDE BS
UNE NEMA
220/240V
380/415V
440V
500V
660/690V
(kA rms)
duration (s)
240V
480V
600V
thermal magnetic
solid state
65
40
35
440
AC 50/60Hz
85
25
10
85
35
20
85
35
20
85
42
20
85
42
20
85
42
30
85
42
30
85
42
30
85
65
50
85
65
50
85
65
50
85
65
50
85
65
50
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
trip units
MERLIN GERIN
660/690
40°C
CEI
protection
PUSH TO TRIP
60 70 80 90
STR 55UE
fault
test
Ir
Im
tr
tm
105 %Ir
I
for distribution
Ih
t
Io
xIn
i
T
th
TFR
for motor starters
for people
connected
ted
disconnec
standard networks
generator fed networks
long distance networks
direct current networks
ELCB's Vigicompact
Vigirex residual current relays
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
105
161
86
1.6
105
161
86
1.6
105
161
86
1.9
140
255
110
6.0
140
255
110
6.0
210
374
172
13
210
374
172
13
210
374
172
13
418
430
337
41
418
430
337
41
418
430
337
46
418
430
337
63
418
550
337
83
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
indications and measurement
Compact C801N with universal chassis
auxiliary and alarm switches (OF-SD-SDE)
local and/or distance control and monitoring (Dialpact)
data transmission (Dialpact)
voltage presence indicator
current transformer module
ammeter module
insulation monitoring module
control accessories
shunt trip (MX) ; undervoltage release (MN)
direct or extended rotary handles
motor mechanism for remote control
ST 306ST
long
time
MERLIN GERIN
OFF
tr
compact
CM2500HE
600V 50/60Hz
2500A max.
84 81
O
N
ground
fault
T
R
I
P
O
F
F
test
trip indicator
(push to reset)
Compact CM1250N
IEC-VDE-BS
push to trip
0
installation
molded case
switch
3-pole
short
time
version
fixed
plug-in on a base
draw-out on chassis
accessories
terminal shields
padlocking and locking device
dimensions of 2-3 pole fixed version (mm)
W
H
D
weight (kg)
3 pole fixed version
models
visible break circuit breaker
switch - disconnector
automatic / manual source changeover
6
Visucompact
Merlin Gerin
Merlin Gerin
■
■
7
1.5 to 3200A: Compact
disconnector mouled case circuit breakers
high breaking capacity range: H
1.5 to 80A
16 to 100A
16 to 160A
16 to 250A
160 to 400A
250 to 630A
320 to 800A
NS80HMA NS100H
NS160H
NS250H
NS400H
NS630H
C801H
C1001H
C1251H
CM1250H CM1600H CM2000H CM2500H CM3200H
3
3-4
3-4
3-4
3-4
3-4
3-4
3-4
3-4
3-4
3-4
3-4
3-4
3
80
750
8
AC 50/60Hz 690
100
750
8
690
160
750
8
690
250
750
8
690
400
750
8
690
630
750
8
690
800
750
8
690
1000
750
8
690
1250
750
8
690
1250
750
8
690
1600
750
8
690
2000
750
8
690
2500
750
8
690
3200
750
8
690
220/240V
380/415V
440V
500V
660/690V
100
70
65
25
6
100%
A
III
100
70
65
50
10
100%
A
III
100
70
65
50
10
100%
A
III
100
70
65
50
10
100%
A
III
100
70
65
50
20
100%
A
III
100
70
65
50
20
100%
A
III
100
70
65
50
40
50%
B
III
100
70
65
50
40
50%
B
III
100
70
65
50
40
50%
B
III
125
85
85
50
50
50%
B
III
125
85
85
50
50
50%
B
III
125
85
85
50
50
50%
B
III
125
85
85
50
50
50%
B
III
125
85
85
50
50
50%
B
III
■
■
■
■
■
■
■
■
■
■
■
■
■
■
12
1
15
1
15
1
32
1
32
1
32
1
32
1
32
1
250N
number of poles
P93083
400 to 1000A 500 to 1250A 625 to 1250A 800 to 1600A 1000 to 2000A 1250 to 2500A 1600 to 3200A
electrical characteristics
MERLIN GERIN
rated current (A)
In
rated insulation voltage (V)
Ui
rated impulse withstand voltage (kV)Uimp
rated operational voltage (V)
Ue
characteristics according to IEC 947.2
rated ultimate breaking
Icu AC 50/60Hz
capacity (kA rms)
compact
NS250 N
OFF
Ui 750V. Uimp 8kV.
Icu
Ue
(kA)
(V)
85
220/240
36
380/415
35
440
30
500
8
660/690
50
250
cat A
Ics=100% Icu
IEC947-2
UNE NEMA
UTE VDE BS CEI
push
to
trip
.9
.85
.8
.7
1
.63
xIn
160/250A
.95
3
.98
2
STR 22 SE
90 %Ir
105
Im
Ir
In=250A
4
5
1.5
10
alarm
6
8
Ir
Im
xIr
Compact NS250H
for DC consult general catalogue
rated service breaking perform.
Ics (% of Icu)
utilisation category
pollution degree
front face insulation class II
rated admissible short time
Icw
withstand current
performances according NEMA
rated breaking capacity AB1 (O-CO) (kA)
100
65
35
100
65
42
100
65
42
100
65
42
125
85
50
125
85
50
125
85
50
125
85
50
125
85
50
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
ELCB's Vigicompact
Vigirex residual current relays ■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
MERLIN GERIN
compact
C 1001 H
Ui 750V. Uimp 8kV.
Icu
Ue
(kA)
(V)
440
500/525
660/690
thermal magnetic
solid state
cat B
Icw 8kA / 0,25s.
Ics = 100% Icu
IEC 947-2
UTE VDE BS
UNE NEMA
240V
480V
600V
100
65
10
100
65
35
100
65
35
100
65
35
■
■
■
■
■
■
■
trip units
100
70
65
40
35
220/240
(kA rms)
duration (s)
100
65
35
I
380/415
40°C
CEI
protection
0
60 70 80 90
STR 55UE
fault
test
Ir
Im
tr
tm
for distribution
105 %Ir
I
Ih
t
Io
xIn
i
T
■
th
TFR
for motor starters
for people
Compact C801H with motor mechanism
standard networks
generator fed networks
long distance networks
direct current networks
indications and measurement
auxiliary and alarm switches (OF-SD-SDE)
local and/or distance control and monitoring (Dialpact)
data transmission (Dialpact)
voltage presence indicator
current transformer module
ammeter module
insulation monitoring module
■
■
control accessories
ST 306ST
long
time
MERLIN GERIN
OFF
tr
compact
CM2500HE
molded case
switch
3-pole
600V 50/60Hz
2500A max.
84 81
short
time
O
N
ground
fault
T
R
I
P
O
F
F
test
trip indicator
(push to reset)
Compact CM1250H
IEC-VDE-BS
push to trip
0
shunt trip (MX) ; undervoltage release (MN)
direct or extended rotary handles
motor mechanism for remote control
installation
version
fixed
plug-in on a base
draw-out on chassis
accessories
terminal shields
padlocking and locking device
dimensions of 2-3 pole fixed version (mm)
W
H
D
weight (kg)
3 pole fixed version
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
90
120
80
1.0
105
161
86
1.6
105
161
86
1.6
105
161
86
1.9
140
255
110
6.0
140
255
110
6.0
210
374
172
13
210
374
172
13
210
374
172
13
418
430
337
41
418
430
337
41
418
430
337
46
418
430
337
63
418
550
337
83
■
■
■
■
■
■
■
■
models
visible break circuit breaker
Visucompact
switch - disconnector
automatic / manual source changeover
8
Merlin Gerin
Merlin Gerin
9
16 to 1000A: Compact
disconnector mouled case circuit breakers
current limiting range: L
250N
number of poles
P93083
rated current (A)
rated insulation voltage (V)
rated impulse withstand voltage (kV)
rated operational voltage (V)
characteristics according to IEC 947.2
rated ultimate breaking capacity
(kA rms)
compact
NS250 N
OFF
Ui 750V. Uimp 8kV.
Icu
Ue
(kA)
(V)
85
220/240
36
380/415
35
440
30
500
8
660/690
50
250
cat A
Ics=100% Icu
IEC947-2
UNE NEMA
UTE VDE BS CEI
push
to
trip
160/250A
90 %Ir
105
Im
Ir
.95
3
.98
2
STR 22 SE
alarm
6
8
10
1.5
1
.63
5
4
.9
.85
.8
.7
Ir
Im
xIr
xIn
Compact NS250L
for DC consult general catalogue
rated service breaking performance
utilisation category
pollution degree
front face insulation class II
rated admissible short time
withstand current
performances according NEMA
rated breaking capacity AB1 (O-CO) (kA)
MERLIN GERIN
compact
NS400 L
Ui 750V.
Ue
(V)
Uimp 8kV.
Icu
(kA)
220/240
380/415
440
500/525
660/690
100
70
65
40
35
Icw 6kA / 0,25s
Ics = 100% Icu
UTE VDE BS
UNE NEMA
push
to
trip
.9
.5
1
1
Im
.9
test
.93
.95
.88
.85
.8
2
1.5
tr
8
6
tm
(s) 3
16
16
(s) @ 6 Ir
for distribution
.7
.8
tr
A
10
4
3
tm
Im I
2
1
1
I2t
on
off
Ir
3
2
0
I2t
.6
x In
th
(s) 4
1
0
on
.5
.4
.3
.2
11
2
1
2
8
10
2
1.5
x In
3
2
6
4
3
8
10
x Ir
4
1
Ih
Il
5
4
3
.98
1
x Io
x In
160 to 400A
250 to 630A
320 to 800A
400 to 1000A
NS250L
NS400L
NS630L
C801L
C1001L
3-4
3-4
3-4
3-4
3-4
3-4
3-4
40°C
100
750
8
690
160
750
8
690
250
750
8
690
400
750
8
690
630
750
8
690
800
750
8
690
1000
750
8
690
AC 50/60Hz
Icu
AC 50/60Hz
Ics
(% of Icu)
Icw
220/240V
380/415V
440V
500V
660/690V
150
150
130
100
75
100%
A
III
150
150
130
100
75
100%
A
III
150
150
130
70
20
100%
A
III
150
150
130
100
75
100%
A
III
150
150
130
50
35
100%
A
III
150
150
100
100
60
50%
A
III
150
150
100
100
60
50%
A
III
■
■
■
■
■
■
■
6.4
1
8
1
(kA rms)
duration (s)
240V
480V
600V
200
130
50
200
130
50
200
130
50
200
130
50
200
130
50
150
100
65
150
100
65
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
105
161
86
1.6
105
161
86
1.6
105
161
86
1.9
140
255
110
6.0
140
255
110
6.0
210
374
262
25
210
374
262
25
■
■
■
■
■
■
■
protection
400
%Ir >Ir >Im >Ih
STR 53 UE
Ir
.8
.7
.6
In
Ui
Uimp
Ue
thermal magnetic
solid state
CEI
In = 400A
Io
16 to 250A
NS160L
trip units
cat B
IEC 947-2
16 to 160A
NS100L
electrical characteristics
MERLIN GERIN
In=250A
16 to 100A
off
for motor starters
for people
Compact NS400L
standard networks
generator fed networks
long distance networks
direct current networks
ELCB's Vigicompact
Vigirex residual current relays
indications and measurement
auxiliary and alarm switches (OF-SD-SDE)
local and/or distance control and monitoring (Dialpact)
data transmission (Dialpact)
voltage presence indicator
current transformer module
ammeter module
insulation monitoring module
control accessories
MERLIN GERIN
compact
C 1001 H
Ui 750V. Uimp 8kV.
Icu
Ue
(kA)
(V)
shunt trip (MX) ; undervoltage release (MN)
direct or extended rotary handles
motor mechanism for remote control
OFF
100
70
65
220/240
380/415
440
500/525
40
35
660/690
cat B
Icw 8kA / 0,25s.
Ics = 100% Icu
IEC 947-2
UTE VDE BS
UNE NEMA
installation
CEI
PUSH TO TRIP
60 70 80 90
STR 55UE
fault
test
Ir
Im
tr
tm
version
105 %Ir
I
Ih
t
Io
xIn
i
TFR
Compact C801L
T
th
accessories
fixed
plug-in on a base
draw-out on chassis
terminal shields
padlocking and locking device
dimensions of 2-3 pole fixed version (mm)
weight (kg)
W
H
D
3 pole fixed version
models
visible break circuit breaker
switch - disconnector
automatic / manual source changeover
10
Visucompact
Merlin Gerin
Merlin Gerin
11
800 to 6300A: Masterpact
disconnector air circuit breaker
number of poles
push to reset
IG
LI
L
G
off
LG
I
I3
I2
I1
O
90%
push OFF
STR 58 UE
I
push ON
20%
Ir
Io
0.8
0.63
tr
120
.92
.95 60
.9
.88
%Ir
1
.8
xIo
xIn
Im
2
1.5
I
Ir :
Ir fault
8
17
22
off
2
xIn
Ih
600
800
500
Im fault
tm
fault
400
th
250
i
Ic1
–T+
th
T
.4
.4
.3
.3
1000 .2
320
I
+S–
test
A
.9
.2
.1
.1
on I2t off
1200
.7
.6
1
xIr
.85
.9
.8
.95
.98
.8
R
Ic2
.93
.86
.85
.95
1
.5
xIr
F
test
connected
test
disconnected
Masterpact M08
discharged
1000V
50/60Hz
Ue 380/440V
480/690V
Icu 100kA
85kA
Ics 100kA
85kA
Icw 75kA 1s
IEC 947-2
.1
0
.1
on I2t off
12
6
th :
Ih
masterpact
M32 H1
00000
.2
.2
10
xIo
4
Im :
tr
8
O OFF
.3
.4
6 .3
3
t
tm
5
4
240
480
15
at 1,5Ir
.98 30
.85
1
0.5
MERLIN GERIN
Ui
50%
90
105
M20
M25
M32
M40
M50
M63
3-4
3-4
3-4
3-4
800-1000-1250-1600
800-1000-1250-1600
1000
8
25 to 30 (with no intentional delay)
<80
690
B
IV
2000-2500
2000-2500
3200-4000
3200-4000
5000-6300
2500-3200
H1
75
75
75
100
165
165
165
75
75
H2
100
100
85
100
220
220
187
75
75
15000 (10000 for M40)
10000 (5000 for M40)
3000
H1
H2
75
100
75
100
75
85
100
100
165
220
165
220
165
187
75
75
75
75
10000
5000
2000
H1
100
100
85
100
220
220
187
100
100
H2
150
150
85
80
330
330
187
100
100
75
75
100
85
75
75
100
100
150
100
electrical characteristics
LIG
I
reset V
M08
M10
M12
M16
rated current (A)
4th pole rating (A)
rated insulation voltage (V)
rated impulse withstand voltage (kV)
breaking time (ms)
closing time (ms)
rated operational voltage (V)
utilisation category
pollution degree
front face insulation class II
endurance
with maintenance
CO cycle
without maintenance
characteristics according to IEC 947-2 (1)
rated ultimate breaking capacity
(kA rms)
In
40°C
Ui
Uimp
total maxi.
Ue
AC 50/60Hz
■
mechanical
mechanical
electrical (440V)
Icu
AC 50/60Hz
rated service breaking performances
rated short-circuit making capacity
(kA peak) 50/60Hz
Ics (% of Icu)
Icm
rated admissible short time
withstand current (kA rms)
performances according NEMA
rated breaking capacity (O-CO) (kA)
Icw
220/415V
440V
500/690V
0.5s
1s
20000
10000
10000
N1
40
40
40
100
84
84
84
40
30
H1
65
65
65
100
143
143
143
65
50
H2
100
100
85
100
220
220
187
65
50
15000
10000
8000
N1
55
55
55
100
121
121
121
55
55
480V
600V
40
40
65
65
100
85
55
55
220/415V
440V
500/690V
100
85
trip units
solid state
■
protection
sensor ratings (A)
control unit protection type (2)
200 to 1600
instantaneous
distribution
selective
universal
unprotected circuit breaker / type
rated short-circuit making capacity (kA peak)
rated breaking capacity for DC (Icu=Ics=Icw)
STR18 M
STR28 D
STR38 S
STR58 U/68 U
200 to 2500
2000 to 6300
■
■
■
NI
HI
HF
NI
HI
HF
84
105
143
84
105
165
HI type only 50kA 125V DC maximum, consult us for other specific version
220/690V
600 to 4000
■
HI
105
HF
165
HI
187
HF
220
indications, measurement and monitoring
ammeter
energy
maintenance indicator
data transmission
load monitoring
alarm indicator
segregated fault indicator
communication (Dialpact)
STR28/38/58/68
STR68
STR68
STR68
STR58/68
STR18/28/38/58/68
STR38/58/68
STR58
■
■
■
■
■
■
■
■
control accessories
shunt trip ; closing release ; undervoltage release
motor mechanism for remote control
■
■
installation
version (front or rear
vertical or horizontal connections)
accessories
12
■
dimensions W x H x D (mm)
fixed
draw-out
automatic safety shutters
padlocking and locking devices
3 pole draw-out version
weight (kg)
3 pole draw-out version
65 (M16: 69)
■
■
■ (M50)
M32 : 130 / M40 : 152
M50 : 815 x 484 x 367
M63 : 1045 x 484 x 367
M50 : 215 / M63 : 245
■
■
■
435 x 439 x 367
Merlin Gerin
Merlin Gerin
82
13
40 to 2500A: Interpact
switch-disconnector
Interpact INS switch-disconnectors
INS40
INS63
INS80
INS100
INS125
INS160
number of poles
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
40
690
8
500
250
AC 22 A
40
40
63
690
8
500
250
AC 22 A
63
63
80
690
8
500
250
AC 22 A
80
80
100
750
8
690
250
AC 22 A
100
100
100
DC 22 A
100
20
154
5500
3175
1230
125
750
8
690
250
AC 22 A
125
125
125
DC 22 A
125
20
154
5500
3175
1230
160
750
8
690
250
AC 22 A
160
160
160
DC 22 A
160
20
154
5500
3175
1230
.4
.2
.1
electrical characteristics as defined by IEC 947-3 and EN 60947-3
MERLIN GERIN
ON
interpact
INS80
Ui 500V
Uimp 6kV
Ith 80A@ 60°C
Ue(V) Ie(A)
AC22A 500 80
AC23A 440 80
AC23A 500 63
DC23A 250 63
I
OFF
O
IEC 947.3
conventional thermal current (A)
rated insulation voltage (V)
rated impulse-withstand voltage (kV)
rated operational voltage (V)
Ith
Ui
Uimp
Ue
rated operational current (A)
Ie
UTE VDE BS CEI UNE
Interpact INS80
short-circuit
making capacity
Icm (kA peak)
short-time withstand current
Icw (A rms)
suitability for isolation
endurance (category A) (CO cycles)
at 60°C
AC 50/60Hz
AC 50/60Hz
DC
AC 50/60Hz
220/240-380/415-440/480V (1)
500V
660/690V
DC (4P in series)
250V
switch-disconnector alone
with upstream protection
1s
3s
20s
mechanical
electrical AC
electrical AC
electrical DC
AC22A 500V
AC22A 690V
AC23A 440V
AC23A 500V
AC23A 690V
DC23A 250V
positive contact indication
degree of pollution
DC 22 A
40
15
75
3000
1730
670
AC 23 A
40
32
DC 23 A
40
DC 22 A
63
15
75
3000
1730
670
AC 23 A
63
40
DC 23 A
63
DC 22 A
80
15
75
3000
1730
670
AC 23 A
80
63
DC 23 A
80
AC 23 A
100
100
63
DC 23 A
100
AC 23 A
125
125
80
DC 23 A
125
■
■
■
■
■
■
20000
3000
20000
3000
20000
3000
3000
2000 (32A)
3000
2000 (40A)
3000
2000 (63A)
1500
yes
III
1500
yes
III
1500
yes
III
15000
2000
2000
2000
2000
1500 (63A)
1500
yes
III
15000
2000
2000
2000
2000
1500 (80A)
1500
yes
III
15000
2000
2000
2000
2000
1500 (100A)
1500
yes
III
90
81
62.5
0.5
90
81
62.5
0.5
90
81
62.5
0.5
135
100
62.5
0.8
135
100
62.5
0.8
135
100
62.5
0.8
AC 23 A
160
160
100
DC 23 A
160
installation
overall dimensions of 3 poles (mm)
W
H
D
approximate weight (kg)
3 poles
Interpact IN switch-disconnectors
IN250
IN400
IN630
IN1000
IN1600
IN2500
number of poles
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
250
690
8
690
250
AC 22 A
250
250
250
250
DC 22 A
250
30
330
8500
4900
1900
400
690
8
690
250
AC 22 A
400
400
400
400
DC 22 A
400
40
330
12000
6900
2680
630
690
8
690
250
AC 22 A
630
630
630
500
DC 22 A
630
50
330
25000
14400
5590
1000
690
8
690
250
AC 21 A
1000
1000
1000
1000
DC 22 A
1000
75
176
35000
20000
7800
1600
690
8
690
250
AC 21 A
1600
1600
1600
1600
DC 22 A
1600
75
105
35000
20000
7800
2500
690
8
690
250
AC 21 A
2500
2500
2500
2500
DC 21 A
1600
105
105
50000
28500
11000
electrical characteristics as per IEC 947-3
I
MERLIN GERIN
interpact
IN630
Ui 660 V
lth 630A
AC 22 630A
AC 23 500A
380/415V
500 V
conventional thermal current (A)
rated insulation voltage (V)
rated impulse withstand voltage (kV)
rated operational voltage (V)
Ith
Ui
Uimp
Ue
rated operational current (A)
Ie
IEC-VDE-BS-UTE
0 OFF
60°C
AC 50/60Hz
AC 50/60Hz
DC
AC 50/60Hz
220/240V
380/415V
440/480 (1) -500V
660/690V
Interpact IN630
DC
making capacity
Icm (kA peak)
short-time withstand current
Icw (kA rms)
suitability for isolation
endurance (category A) (CO cycles)
250V (1P)
switch-disconnector alone
with upstream protection
1s
3s
20s
mechanical
electrical AC
electrical DC
AC22A 690V
AC23A 500V
DC23A 250V
positive contact indication
degree of pollution
AC 23 A
250
250
250
125
DC 23 A
250
AC 23 A
400
400
400
250
DC 23 A
400
AC 23 A
630
500
500
320
DC 23 A
630
AC 22 A
1000
1000 (2)
800
DC 23 A
1000
AC 22 A
1600
1600 (2)
1200
DC 23 A
1600
AC 22 A
2500
2500
DC 22 A
■
■
■
■
■
■
10000
1000
1000
1000
yes
III
10000
1000
1000
1000
yes
III
10000
1000
1000
1000
yes
III
3000
500
3000
500
3000
500
500
yes
III
500
yes
III
500 (DC21A)
yes
III
230
170
99.5
2.7
280
230
118
4.3
280
230
118
4.8
340
300
118
12
340
300
118
15
340
440
200
35
installation
dimensions of 3 poles fixed FC (mm)
(1) Suitable for 480 V NEMA.
(2) IN1000 and IN1600: 630A in AC23A.
14
weight (kg)
W
H
D
3 poles, fixed, FC
Merlin Gerin
Merlin Gerin
15
circuit protection
circuit breakers up to 63 A
C60H circuit breaker - EN 60898
10000
3
type
width
in mod.
of 9 mm
2
1P
1
00000
2
????
2P
1
2
4
3
4
????
00000
3P
1
2
????
00000
6
3
4
5
6
rat.
(A)
0.5
1
2
3
4
6
10
13
16
20
25
32
40
50
63
0.5
1
2
3
4
6
10
13
16
20
25
32
40
50
63
0.5
1
2
3
4
6
10
13
16
20
25
32
40
50
63
cat. No.
B
C
curve curve
D
curve
B, C and D curves
Application
Control and protection of circuits against
overloads and short-circuits.
c in domestic installations;
c in commercial and industrial electrical
distribution systems.
Technical data
c current rating: 1 to 63 A at 30 °C;
c voltage rating: 230-400 V AC;
c breaking capacity:
rat.
type
(A)
to EN 60898
1 to 63
1P
2, 3P
to IEC 947-2 Icu
1 to 63
1P
2, 3P
breaking
capacity (A)
230
400
10000
10000
230-240
230-240
400-415
15000
30000
15000
c positive contact indication;
c fast closing;
c number of operating cycles (0-C): 20000;
c tripping characteristics:
v B curve: the magnetic releases operate
between 3 and 5 In,
v C curve: the magnetic releases operate
between 5 and 10 In,
v D curve: the magnetic releases operate
between 10 and 14 In;
c tropicalization: treatment 2 (relative
humidity 95 % at 55 °C);
c weight (g):
type
1P
110
2P
220
3P
340
c connection: tunnel terminals for rigid
cables up to:
v 25 mm 2 for rating ≤ 25 A,
v 35 mm 2 for rating ≤ 63 A;
c comb busbars 100 A - 40 °C
type
1P
2P
3P
Merlin Gerin
voltage
(V)
No. mod.
24
96 (set of 2 combs 48 mod.)
108
96 (set of 2 combs 48 mod.)
108
24
96 (set of 2 combs 48 mod.)
108
cat. No.
14881
14891
14801
14892
14802
14883
14893
14803
15
circuit protection
circuit breakers up to 63 A
C60N circuit breaker - EN 60898
6000
3
type
width
in mod.
of 9 mm
2
1P
1
00000
2
????
2P
1
2
4
3
4
????
00000
3P
1
2
????
00000
6
3
4
5
6
rat.
(A)
0.5
1
2
3
4
6
10
13
16
20
25
32
40
50
63
0.5
1
2
3
4
6
10
13
16
20
25
32
40
50
63
0.5
1
2
3
4
6
10
13
16
20
25
32
40
50
63
cat. No.
B
C
curve curve
D
curve
B, C and D curves
Application
Control and protection of circuits against
overloads and short-circuits.
c in domestic installations;
c in commercial and industrial electrical
distribution systems.
Technical data
c current rating: 1 to 63 A at 30 °C;
c voltage rating: 230-400 V AC;
c breaking capacity:
rat.
type
(A)
to EN 60898
1 to 63
1P
2, 3P
to IEC 947-2 Icu
1 to 63
1P
2, 3P
breaking
capacity (A)
230
400
6000
6000
230-240
230-240
400-415
10000
20000
10000
c number of operating cycles (0-C): 20000;
c tripping characteristics:
v B curve: the magnetic releases operate
between 3 and 5 In,
v C curve: the magnetic releases operate
between 5 and 10 In,
v D curve: the magnetic releases operate
between 10 and 14 In;
c tropicalization: treatment 2 (relative
humidity 95 % at 55 °C);
c weight (g):
type
1P
110
2P
220
3P
340
c connection: tunnel terminals for rigid
cables up to:
v 25 mm 2 for rating ≤ 25 A,
v 35 mm 2 for rating ≤ 63 A;
c comb busbars 100 A - 40 °C
type
1P
2P
3P
14
voltage
(V)
No. mod.
24
96 (set of 2 combs 48 mod.)
108
96 (set of 2 combs 48 mod.)
108
24
96 (set of 2 combs 48 mod.)
108
cat. No.
14881
14891
14801
14892
14802
14883
14893
14803
Merlin Gerin