PCVVN1418

Warning

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
R ead the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need
the outdoor unit close to the sea shore, contact your local distributor.

to install



Hotline: 0976 173 173

Đại lý phân phối

• HEAD OFFICE

TRUNG TÂM


DICH VU KHÁCH HÀNG
Miễn phí cöôùc cuoäc goïi

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan
CÔNG TY CỔ PHẦN VIỆT KIM
• VĂN PHÒNG CHÍNH
Tầng 14-15, tòa nhà Nam Á, 201-203 Cách Mạng Tháng 8, P.4, Q.3,
TP.HCM
Tel: (08) 62 504 888
Fax: (08) 62 504 999
• CHI NHÁNH HÀ NỘI
Tầng 12, tòa nhà Ocean Park Tower, 1 Đào Duy Anh, Quận Đống Đa,
Hà Nội
Tel: (04) 35 657 677
Fax: (04) 35 657 688
• CHI NHÁNH ĐÀ NẴNG
Tầng 12, Lô A2.1, Đường 30/4, P. Hòa Cường Bắc, Q. Hải Châu, TP. Đà Nẵng
Tel: (0511) 362 4250
Fax: (0511) 362 4251
www.daikin.com.vn

Specifications, designs and other content appearing in this brochure are current as of February 2014 but subject to change without notice.

All rights reserved
Printed in Vietnam



Hotline: 0976 173 173
Cooling Only / Heat Pump 50 Hz



Next Generation VRV IV System
First launched in Japan in 1982, the Daikin VRV system
First launched in Japan in 1982, the Daikin VRV system
has been embraced by world markets for over 30 years.
has been embraced by world markets for over 30 years.
Now, Daikin proudly introduces the next generation
Now, Daikin proudly introduces the next generation
VRV IV system.
VRV IV system.
It now offers an enhanced lineup to meet an ever
It now offers an enhanced lineup to meet an ever
wider variety of needs while improving energy savings,
wider variety of needs while improving energy savings,
comfort, and ease of installation.
comfort, and ease of installation.

INDEX
INDEX

Main Features
Main Features

P03
P03

Outdoor Unit
Lineup Unit
Outdoor

Lineup

P13
P13

Indoor Unit
Lineup
Indoor Unit
Lineup

P15
P15

Specifications
Specifications

P37
P37

Outdoor Unit
Combinations
Outdoor Unit
Combinations

P67
P67

Option List
Option List


P69
P69

Control Systems
Control Systems

P75
P75

Air Treatment
Equipment
Lineup
Air
Treatment
Equipment Lineup

Enhanced
Enhanced lineup
lineup

Energy
Energy saving
saving

3 types up to 60 HP
3 types up to 60 HP

Higher COP and VRT technology
Higher COP and VRT technology


Ease
Ease of
of installation
installation

Comfort
Comfort

Compact & lightweight design
Compact & lightweight design

P89
P89

Air Handling
Unit
Air Handling
Unit

P103
P103

Lower operation sound
Lower operation sound

* VRV is a trademark of Daikin Industries, Ltd.
* VRV is a trademark of Daikin Industries, Ltd.

01
01






Hotline: 0976 173 173

02
02


Excellent
Excellent Operation
Operation Performance
Performance
Energy
Energysaving
saving

Enhanced
EnhancedLineup
Lineuptoto33types
types

Higher
HigherCoefficient
CoefficientofofPerformance
Performance(COP)
(COP)
Enables

Enablesfurther
furtherenergy
energysaving
saving
1212HP-50
HP-50HP
HPwith
with4 4new
newmodels
modelslineup
lineup

Installation
Installation
Space
Space
Product
Product
Weight
Weight

1010
%%
Increase
Increase

Ease
Easeofofinstallation
installation
Compact

Compact&&lightweight
lightweightdesign
design

Offers
Offershigher
highercapacity
capacityofofup
uptoto6060HP
HP
6 6HP-60
HP-60HP
HPwith
with3 3new
newmodels
modelslineup
lineup

VRV
VRV

1,240
1,240
mmmm

COP
COP
during
during
cooling

cooling
operation
operation 3.94
3.94

20
20HP
HP

Highly-integrated
Highly-integrated
VRV
VRV
ⅣⅣ
system
system
offers
offers
compact
compact
outdoor
outdoor
units
units
to to
achieve
achieve
maximum
maximum
utilisation

utilisation
of of
thethe
installation
installation
space.
space.

3.94
3.94

Installation
Installation
Space
Space

1.66
1.66
m2m2

1.42
1.42
m2m2

Product
Product
Weight
Weight

490

490
kgkg

380
380
kgkg

VRV
VRV 12 12
HPHP

765765
mmmm

VRV
VRV 12 12
HPHP

1414
%%

Decrease
Decrease

2222
%%
Decrease
Decrease

New

Newseries
serieswith
withcompact
compact&&lightweight
lightweightdesign
design
1818HP-50
HP-50HP
HPwith
with1717new
newmodels
modelslineup
lineup

VRV
VRV
3.11
3.11

COP
COP
during
during
cooling
cooling
operation
operation 3.94
3.94

20

20HP
HP

Installation
Installation
Space
Space

1.66
1.66
mm

2

0.95
0.95
m2m2

Product
Product
Weight
Weight

490
490
kgkg

320
320
kgkg


2

Lineup
Lineup

Mo/C
Mo/C

4343
%%
Decrease
Decrease
3535
%%

2525
%%
Decrease
Decrease

Product
Product
Weight
Weight
285
285
kgkg

Product

Product
Weight
Weight
195
195
kgkg

3232
%%
Decrease
Decrease

8 HP
8 HP

1010
HPHP

1212
HPHP

5757

5757

5858

6060

5555


5656

5757

5959

Without
Without
increasing
increasing
operation
operation
sound,
sound,
advanced
advanced
analytic
analytic
technologies
technologies
are
are
utilised
utilised
to to
optimise
optimise
fanfan
design

design
and
and
increase
increase
airflow
airflow
rate
rate
and
and
high
high
external
external
static
static
pressure.
pressure.

Decrease
Decrease

New
New
Lineup
Lineup

High-COP
High-COP

Type
Type

Streamlined
Streamlined
airair
grille
grille
It promotes
It promotes
thethe
discharge
discharge
of of
swirling
swirling
airflow,
airflow,
further
further
reducing
reducing
thethe
pressure
pressure
loss.
loss.

Streamlined
Streamlined

scroll
scroll
fanfan
The
The
sharp
sharp
edge
edge
of each
of each
fanfan
blade
blade
hashas
a certain
a certain
curvature,
curvature,
reducing
reducing
both
both
thethe
vibration
vibration
andand
thethe
pressure
pressure

loss.
loss.
Streamlined
Streamlined
scroll
scroll
fanfan

Standard
Standard
Type
Type

Illustrated
Illustrated
fanfan

Space
Space
Saving
Saving
Type
Type



Installation
Installation
Space
Space

0.71
0.71
m2m2

6 HP
6 HP

Large
Large
airflow,
airflow,
high
high
static
static
pressure
pressure
and
and
quiet
quiet
technology
technology

HPHP

0303

Installation
Installation

Space
Space
0.95
0.95
m2m2

Sound
Sound
level(dB(A))
level(dB(A))

Improve
Improve
heat
heat
exchanger
exchanger
efficency,
efficency,
helps
helps
to to
reduced
reduced
operation
operation
sound.
sound.

Space

SpaceSaving
SavingType
Type

1212
HPHP

1212
HPHP

Comfort
Comfort
Lower
Loweroperation
operationsound
sound

Compact
Compact
Design
Design

930930
mmmm

765765
mmmm




1˜ 21dB(A)
reduction
reduction
than
than
˜ 2 dB(A)
conventional
conventional
model
model

Nighttime
Nighttime
quiet
quiet
operation
operation
function
function

Outdoor
Outdoor
PCB
PCB
automatically
automatically
memorises
memorises
thethe
time

time
when
when
thethe
peak
peak
outdoor
outdoor
temperature
temperature
appears.
appears.
It will
It will
enable
enable
, and
return
return
to to
normal
normal
quiet
quiet
operation
operation
mode
mode
after
after

8 h8*1h, *1and
mode
mode
after
after
it keeps
it keeps
forfor
9 h9*2h. *2.
*1 *1
8 h8ish the
is the
initial
initial
setting
setting
with
with
6 h6or
h 10
or 10
h also
h also
available.
available.
*2 *2
9 h9ish the
is the
initial
initial

setting
setting
with
with
8 h8or
h 10
or 10
h also
h also
available.
available.

Capacity
(%)
Capacity
(%)

Standard
StandardType
Type
Up
Uptoto
6060HPHP

*Cooling
*Cooling
operation
operation
conditions:
conditions:

Indoor
Indoor
temp.
temp.
of of
27ºCDB,
27ºCDB,
19ºCWB,
19ºCWB,
andand
outdoor
outdoor
temp.
temp.
of 35ºCDB.
of 35ºCDB.
*12*12
HPHP
of VRV
of VRV
IV improves
IV improves
more
more
compact
compact
design
design
andand
more

more
saving
saving
space
space
than
than
VRV
VRV
III III

6 HP
6 HP 8 HP
8 HP 1010
HPHP* 12
HPHP 1414
HPHP 1616
HPHP 1818
HPHP
* 12

Peak
Peak
in outdoor
in outdoor
temperature
temperature

100 100


Night
Night
mode
mode

50 50

Load
(%)
Load
(%)

20
20HP
HP

4.35
4.35

2.13
2.13
m2m2
555
555
kgkg

3.25
3.25

33

00

1.66
1.66
m2m2
490
490
kgkg

3.72 3.67
3.84
3.84 3.72
3.67 3.46
3.46

3.53.5

VRV
VRV
COP
COP
during
during
cooling
cooling
operation
operation 3.94
3.94

4.41

4.41 4.30
4.30

8 hrs
8 hrs

0 0
60 60

Operating
sound
(dB)
Operating
sound (dB)

Energy
Energy
Saving
Saving

Cooling
Cooling 4.5
4.5
Operation
Operation
44
COP
COP

Main Features

Main Features

High-COP
High-COPType
Type

57 57
50 50

40 40

8:008:00

Enable
Enable
night
night
mode
mode
12:00
12:00

16:00
16:00

20:00
20:00

9 hrs
9 hrs


VRV
VRV
IVIV

min.
min.
4040
dB(A)
dB(A)
0:000:00

4:004:00

8:008:00

Notes:
Notes:
· This
· This
function
function
is available
is available
in setting
in setting
at site.
at site.
· The
· The

operating
operating
sound
sound
in quiet
in quiet
operation
operation
mode
mode
is the
is the
actual
actual
value
value
measured
measured
by by
ourour
company.
company.
· The
· The
relationship
relationship
of outdoor
of outdoor
temperature
temperature

(load)
(load)
andand
time
time
shown
shown
above
above
is just
is just
an an
example.
example.

Hotline: 0976 173 173

0404


Excellent
Operation
Performance
Excellent
VRT-Variable
Operation
Refrigerant
Performance
Temperature
Enhanced

Lineup to 3 types
State-of-the-art
saving technology for VRV system
Enhanced
Lineupenergy
to 3 types

Higher
Coefficient
Performance
(COP)
Basic
mode
is selected toof
maintain
optimal comfort.
Higher
Coefficient
of
Performance
(COP)
VRT is selected to save energy and prevent excessive cooling or heating.

Cooling 4.5
4.41 4.30
Cooling
Operation
4.41 4.30
4.5
Capacity

priority
Operation
4
COP
4 Fixed Refrigerant
COP
3.5 Temperature

COP during cooling operation 3.94
COP during
coolingSpace
operation 3.94
Installation
1.66 m2
Refrigerant cycle
2
Installation
Space
1.66
490mkg
Product Weight
(During cooling)
490 kg
Product Weight

Standard Type
Standard Type

Increase


Condensing temperature lowered
Compressor workload reduced

Condenser
Indoor unit
heat exchanger

2.13
555mkg
(During heating)
555 kg
2

10%
Increase
10
%

Compressor

Evaporator

Condenser
Indoor unit
heat exchanger

Compressor

Offers higher capacity of up to 60 HP Evaporator
Offers

higher
capacity
up to 60
HP
6 HP-60
HP with
3 newofmodels
lineup
6 HP-60 HP with 3 new models lineup
Evaporating temperature raised
Compressor workload reduced

Up to
Up
60 to
HP
60 HP

VRV
VRV

Typical changes in evaporating temperature and COP
COP during
depending
on changing
load
cooling
operationindoor
3.94
3.94

14%
COP during cooling operation 3.94 2
3.94
Decrease
14%
1.42 m2
1.66 m
Installation Space
Decrease
1.42 m2
1.66 m2
Installation Space
22%
100%
Product Weight
490 kg
380 kg
Decrease
22%
Product Weight
490 kg
380 kg
Decrease
Required capacity changes
Capacity
as air conditioning load
changes
to match
changes according to
heat load

outdoor temperature.

Cooling load
& capacity

20 HP
20 HP

Space Saving Type
Space Saving Type
25%

New series with Temp.
compactIn&
lightweight
design
case
of fixed evaporating
New
series
with
compact
&
lightweight
design
18 HP-50 HP with 17 newtemperature,
models excessive
lineup cooling,
thermo on-off
loss, and other

18 HP-50 HP with 17 new models
lineup

25℃

30℃

Compact
Compact
Design
Design
High

VRT

20 HP
20 HP

Without VRT

20℃

25℃

Lineup
Lineup

35℃

Outdoor


VRV
VRV

inefficiencies occur.

Low

Refrigerant evaporating
temp. / Te(℃)

20℃

Automatic control to
3.11
COP
during
cooling operation 3.94
43%
adjust
temperature
3.11 2
COP during cooling operation 3.94 2
Decrease
43%
0.95 m
1.66 m
Installation Space
Decrease
35%

0.95 m2
1.66 m2
Installation Space
Automatic320
control
Product Weight
490 kg
kg adjusts
Decrease
35%
Product Weight
490 kgevaporating
320 temperature
kg
Decrease
to heat load change.

30℃

35℃

Outdoor
Temp.

High
Low

03
0305


New Lineup
New Lineup

Energy efficiency is
improved without
sacrificing comfort.

COP

HP
HP
High-COP Type
High-COP Type
Standard Type
Standard Type
Space Saving Type
Space Saving Type

Without VRT

Fixed Te/Tc - Standard control
(default setting on VRV IV)

25℃

30℃

35℃

Outdoor

Temp.



27ºCDB,
19ºCWB,
outdoor more
temp.compact
of 35ºCDB.
*12 HP
of VRV and
IV improves
*12 HP
of VRV
IV more
improves
more
compact
design
and
saving
space
than VRV III
High Sensible Mode
design and more saving space than VRV III

Floating target Te/Tc depending on heat load

Fixed target Te


Ease of installation
Ease of installation
Selecting VRT enables operation to be optimised for
Compact
& lightweight design
either energy
efficiency or rapid
cooling/heating.
Compact
& lightweight
design
Highly-integrated VRV Ⅳ
Highly-integrated
VRV Ⅳ
system offers compact
system
offers
compact
outdoor
units
to achieve
outdoor
unitsutilisation
to achieveof the
maximum
maximum
utilisation
installation space.of the
installation space.


Reaction speed

Comfort
Comfort

Very Fast

Installation
Installation
Space
Space
0.95 m2
0.95 m2

Product
Product
Weight
Weight
1,240 mm
930 mm
765
285
kg
765
mm
1,240 mm
mm
930 mm
285 kg
VRV

12 HPMode
12Mild
HP Mode
Quick
VRV
12 HP
12 HP
Reaction speed

Fast

Improve heat exchanger
30
Improve
heathelps
exchanger
efficency,
to reduced
efficency,
helps
to reduced
operation sound.
operation
Startsound.
of

Reaction speed

12 HP
12 HP

Installation
25%
Installation
Space
25Decrease
%
Space
2
0.71 m
Decrease
0.71Fixed
m2 Te

Product
32%
Product
Weight
32Decrease
%
Weight
195 kg
Decrease
195
kg Mode
Eco

765
mm

765

mm

Lower
sound
VRT offersoperation
quicker cool down
Lower
operation
sound
to shorten
uncomfortable
pull down time.

cooling

VRV
12 HP
VRV
12 HP

Floating Te/ Tc

Powerful Mode

Medium

Unable to change Te

Sound level(dB(A))
Sound level(dB(A))


• Can boost capacity above 100% if needed.
6 HP
8 HP
10 HP
12 HP
The refrigerant temperature can go lower in cooling (higher in heating)
6 HP
8 HP
10
HP (maximum
12 HP
than
the
set
minimum
in 60
heating).
Powerful
57
57
58
•57
Gives priority58
to very fast reaction
57mode
60 speed.
1˜ 2 dB(A) reduction than
The56
refrigerant temperature

goes down
fast to keep
55
57
59 (or up in1heating)
conventional
reductionmodel
than
˜ 2 dB(A)
the
room
setpoint
stable.
55
56
57
59
conventional model

Powerful
Quick
Mild

Large airflow, high static pressure and
Large
high static pressure and
quietairflow,
technology
Set temperature
quiet

technology
25

Quick
mode

• Gives priority to fast reaction speed.
Nighttime
quiet operation
The refrigerant temperature
goes down (orfunction
up in heating) fast to keep
Nighttime
quietstable.
operation function
the room setpoint

Outdoor PCB automatically memorises the time when
Outdoor
PCB
automatically
memorises
the time
peak
outdoor
temperature
appears.
It willwhen
enable
Without increasing operation sound, advanced

•the
Gives
priority
to efficiency.
Mild the peak
Time
*1 in heating)
outdoor
temperature
Itreturn
will
enable
The refrigerant
temperature
goes
downappears.
(orhup
gradually
giving
Without
increasing
operation
sound,toadvanced
Very utilised
Fast
quiet
operation
mode
after
8

,
and
to
normal
analytic
technologies
are
optimise
fan
mode
priority to the efficiency of the system instead
of the reaction speed.
Fast
*1
quiet
operation
analytic
are
utilised
to and
optimise
fan
mode
after itmode
keepsafter
for 98 hh*2., and return to normal
Medium
designtechnologies
and increase
airflow

rate
high
external
mode after it keeps for 9 h*2.
design
increase airflow rate and high external
staticand
pressure.
*1 8 h is the initial setting with 6 h or 10 h also available.
Streamlined air grille
static pressure.
h isinitial
the initial
setting
h or
also available.
*1 8 *2
h is9 the
setting
with 6with
h or8 10
h 10
alsoh available.
It promotes
discharge of
Streamlined
airthe
grille

swirling airflow,

furtherof
promotes
discharge
Recommended forItswirling
use
inthe
these
reducing
the
airflow,
further situations
pressure
reducing
the loss.

40
35

Av. max. temp.

Streamlined scroll fan

a certain
Thehas
sharp
edge ofcurvature,
each fan reducing
blade
the vibration
and

the pressure
hasboth
a certain
curvature,
reducing
bothloss.
the vibration and the pressure
loss.
Streamlined
scroll fan
Streamlined
scroll fan (Typical example)

25
20
15

Av. min. temp.
Mar.

Jun.

Sep.
Illustrated

fan when
VRT is particularly effective Illustrated
at night
fan
temperatures are low.




100

100

Av. daily temp.
difference
The
sharpscroll
edge fan
of each fan blade
Streamlined

30

0

20℃

0

pressure
loss.
Cooling only regions having
differences
in daily temperature.

Mo/C

Mo/C

VRT

3

6 HP
8 HP 10 HP * 12 HP 14 HP Mode
16 HP 18 HP
Basic
6 HP Mode
8 HP 10 HP * 12 HP 14Auto
HP 16 HP 18 HP

0

Outdoor Temp. (ºC)

During
cooling, the refrigerant evaporating
20 HP
20 HP (Te) is raised to minimise the
temperature
difference with the condensing temperature.
During heating, condensing temperature (Tc) is
lowered to minimise the difference to the
evaporating temperature. Compressors work less,
and this reduces power comsumption.

4.35

4.35
2.13 m2

3

Indoor Temp. (ºC)

VRV
VRV

3.5

Energy saving priority

3.84 3.72 3.67
Variable
Refrigerant Temperature
3.84 3.72 3.67
3.46
3.25
3.46
*Cooling operation conditions: Indoor temp. of
3.25
*Cooling
operation
conditions:
Indoor temp. of 35ºCDB.
27ºCDB,
19ºCWB,
and outdoor


Main Features
Main Features
Main Features

High-COP Type

The new VRV IV system now features VRT technology.
VRT automatically adjusts refrigerant
to individual
Enables
further energy saving
Energy temperature
Enables
further
energy
building and climate requirement,
thus further
improving
Energy
12 HP-50 HP with
4 newsaving
models lineup
Saving
annual energy efficiency and
maintaining
comfort.
12
HP-50
HP

with
4
new models lineup
Saving
With this excellent technology, running costs are reduced.

Operating Load Capacity
sound
(dB)
(%)
(%)
Outdoor
Temp. (ºC)
Operating Load Capacity
sound (dB)
(%)
(%)

Customise
your VRV
system for optimal annual efficiency
High-COP
Type

How is energy reduced?

Energy saving
Energy
saving
Fine control

to match user preference available through mode selection

Dec.

*2 9 h is the initial setting with 8 h or 10 h also available.
Peak in outdoor temperature
Night mode
Peak in outdoor temperature
Night mode

Cooling/heating regions having periods
of mild
outdoor temperatures.
50
50

40
35
0

60
30
57
25
50

Heating
period

Intermediate

period

0
60

57
Av.
50 max. temp.

40
20
8:00
40
158:00

Cooling period
9 hrs
8 hrs
9 hrs
8 hrs

Intermediate Heating
period
period

VRV IV

VRV
IVdB(A)
Enable night mode

min. 40
Enable night mode
min. 40 dB(A)
12:00

12:00

16:00

16:00

20:00

20:00

0:00

0:00

4:00

4:00

8:00

8:00

(Typical example)
Notes: · This function
available

Av.ismin.
temp. in setting at site.
· The
operating
soundininsetting
quiet operation
Notes:0 · This
function
is available
at site. mode is the actual value
Mar.
Jun.
Sep.
Dec.
by ourincompany.
· The measured
operating sound
quiet operation mode is the actual value
VRT ismeasured
particularly
during
the intermediate
periods.
· The relationship
of outdoor
temperature
(load) and time
shown
by oureffective
company.

is justofanoutdoor
example.
· The above
relationship
temperature (load) and time shown
above is just an example.

Hotline: 0976 173 173

04
0406


Excellent
Operation
Performance
More Flexible
SystemPerformance
Design
Excellent
Operation
Energy saving
Energy saving

Enhanced
Lineup
to 3 types location
More options
for to
installation

Enhanced
Lineup
3 types

Cooling
4.41
4.5 indoor
and residential
units 4.30
Cooling
Operation
4.41 4.30
4.5
Operation
4
COP
4
COP

Energy
Energy
Saving
Saving

For connection of only VRV
indoor units

Max. actual piping length

165 m


20 HP
20 HP
Max. equivalent piping length

Enables further energy saving
Multiple use
Enables
energy
12 HP-50further
HP with
4 newsaving
models lineup
12 HP-50 HP with 4 new models lineup
q

COP during cooling operation 3.94
COP during
coolingSpace
operation 3.94
Installation
1.66 m2
2
Installation
Space
1.66
490mkg
Product Weight
490 kg
Product Weight


190 m

Max. level difference
between the outdoor units
and the indoor units

Max. level difference
between the indoor units

20 HP
20 HP

Up to
Up
60 to
HP
60 HP
90 m

2

30 m

Max.

90 m

2


First
Increase

2
2.13
555mkg
555 kg

indoor branch

f

a

p

b

*The rest of indoor units are
the same as for single use.

a

e

i

VRV
VRV


COP during cooling operation 3.94
3.94
14% Max.
COP during cooling operation 3.94 2
3.94
Decrease
14% s 30 m
2
1.42
m
1.66
m
Installation
Space
15 m higher
Decrease
1.42 m2
1.66 m2
Installation Space
22%
than VRV
Product Weight
490 kg
380 kg
Decrease
% such as a .
Colours in the diagram above are merely for identifying pipes referenced with22
symbols
Product Weight
490 kg

380 kg
Decrease
Actual
piping length

Example

Equivalent
piping length

Refrigerant piping length

165 m

a+f+g+h+i

190 m

Total piping length

1000 m

a+b+c+d+e+f+g+h+i



Between the first indoor branch and the farthest indoor unit

90 m*1


f+g+h+i

Space Saving Type
Space Saving Type
Maximum
allowable
piping length

4.35
4.35
2.13 m2

g to 60h HP
f of up
Offers higher capacity
Offers
higher
capacity
of
up
to 60
HP
6 HP-60 First
HPindoor
with
3 new
lineup
b models
d
c

branch
6 HP-60 HP with 3 new models lineup
r

10%
Increase
10
%

First outdoor branch

Single use

Standard Type
Standard
Max.
total piping length Type

1000 m

k
VRV
VRV



New series with compact & lightweight design
New
seriesHP
with

compact
lightweight
design
Compact
Level
18 HP-50
with
17
new&models
lineup
Example
Difference
Compact
18
HP-50
HP
with
17
new
models
lineup
Design
Between the outdoor units (Multiple use)
5m
q
Between the outdoor branch and the last outdoor unit

Maximum
allowable
level difference


Design

10 m

k+p

VRV
VRV

30 m

Between the indoor units

13 m

s

90 m
r
3.11
COP during cooling operation
3.94
43%
r3.11
90 m 3.94
operation
Decrease
43%
2

0.95 m2
1.66 m
Installation Space
Decrease
1. No special requirements up to 40 m. The maximum actual piping length can beInstallation
90 m, dependingSpace
on conditions. Various
conditions
0.95 m2have to be met35%
1.66
m2 and requirements
to allow utilisation of 90 m piping length. Be sure to refer to the Engineering Data Book
for details
of these conditions and
requirements.
Product
Weight
490
kg
320 kg
Decrease
35%
2. When level differences are 50 m or more, the diameter of the main liquid piping size must be increased and connection ratio must be 80% to 130%. If the outdoor unit
Product Weight
490 kg
320 kg
Decrease
is above the indoor unit, a dedicated setting on the outdoor unit is required. Refer to the Engineering Data Book and contact your local dealer for more information.
Between the outdoor units
and the indoor units


If the outdoor unit is above.

2

If the outdoor
is below.cooling
COPunit
during

20 HP
20 HP

Connection ratio
Lineup
Connection capacity at maximum is 200%.
Lineup
Connection ratio

HP
HP
50%–200%
High-COP Type
High-COP Type
Standard
ConnectionType
ratio =
Standard
Type
Total capacity index of the indoor units

Space Saving Type
Capacity
Space Saving
Typeindex of the outdoor units

03
0307

Conditions of VRV indoor unit connection capacity
Applicable
VRV indoor units
Single outdoor units
Double outdoor units
Triple outdoor units

Mo/C
Mo/C
FXDQ, FXMQ-P, FXAQ models

200%

Other VRV indoor

New unit
Lineup
models*1
New Lineup

3.5
3.5

3
3
0
0

3.46
3.46
b

Colours in the diagram below are merely for identifying
pipes referenced with symbols such as a .

3.25
3.25

a
6 HP
8 HP 10 HP * 12 HP 14 HP e 16 HP 18 HPf
branch
6 HP
8 HP 10 HP * 12First
HPindoor14
HP BP
16 HP 18 HP
VRV : VRV indoor unit
RA : Residential indoor unit
BP : BP unit

Max.


50 m
Ease of installation
Ease of installation

h

n

Compact & lightweight design Max.
Compact & lightweight design l 15 m

i
RA

Maximum allowable
piping length

Comfort
Comfort

1,240
mm
Total piping
length
VRV

VRV

Between BP unit
and indoor unit


765
mm

930 mm

*12 HP
of VRV
IVg
improves
more
compact
design
and
more
saving
space
than VRV III
Max.
design and more saving space than VRV
o III
m
Max.

Installation
Installation
Space
Space
0.95 m2
0.95 m2


765
mm

765
mm

Product
Actual
piping
length
Product
Weight
Weight
100 m
285
kg
250 m
285 kg
2 m–12 m

If indoor unit capacity index is 71.

2 m–8 m

Minimum allowable piping length Between outdoor unit and the first indoor branch
Lower
operation sound
Lower operation sound
6 HP


6 HP
57
57
55
55

8 HP
8 HP
57
57
56
56

If the outdoor unit is above.

k

12 HP
VRV
12 HP
Installation
25%
Installation
Space
RA
25Decrease
%
Space
2

0.71 m
Decrease
0.71 m2

h, i, j, k
b+c+g, b+c+d

50 m*1
5m
Sound
level(dB(A))
Sound level(dB(A))

10 HP
12 HP
10 HP
12 HP
Level Difference
58
60
15 m 60
58
5715 m
59
57
59

If the outdoor unit is below.

40


m

Product
Example
32%
Product
Weight
32Decrease
%
Weight
a+b+c+g+k, a+b+c+d
195 kg
Decrease
195a+b+c+d+e+f+g+h+i+j+k
kg

2 m–15 m

If indoor unit capacity index is 60.

15 m

BP

VRV
12 HP
VRV
12 HP RA


Between the first indoor branch and the farthest BP unit or
between the first indoor branch and the farthest VRV indoor unit

and the indoor unit

*Cooling operation conditions: Indoor temp. of
*Cooling
operation
conditions:
Indoor temp. of 35ºCDB.
27ºCDB,
19ºCWB,
and outdoor
d
27ºCDB,
19ºCWB,
outdoor more
temp.compact
of 35ºCDB.
*12 HP
of VRV and
IV improves

VRV

12 HP
12 HP
12 HP If indoor unit capacity index
12 HP
< 60.


Improve heat exchanger
Improve
heathelps
exchanger
Between the indoor units
efficency,
to reduced
efficency,
helps
to
reduced
Between BP units
operation sound.
Maximum allowable
operation
sound.
Between the outdoor unit
level difference

c

j

RA

Highly-integrated VRV Ⅳ
Highly-integrated
VRV Ⅳ
system offers compact

system
offers
compact
outdoor
units
to achieve
outdoor
unitsutilisation
to achieveof the
maximum
When a mixed
combination of VRV and residential indoor units is connected
maximum
utilisation
of the
installation
or when onlyspace.
residential indoor units are connected
765
installation space.
1,240
mm
mm
Refrigerant piping
length
930 mm

50 m
40 m


a
Example

l
1˜ 2 dB(A)
reduction than
conventional
1˜ 2 dB(A)
than
mreductionmodel
conventional
model
n
n

Large airflow, high static
pressure and
Nighttime quiet operation function o
Between the outdoor unit and the BP unit
40 m
Large
high static
pressure and
Nighttime quiet operation
function
quietairflow,
technology
Outdoor
PCB
automatically

memorises
time when
*1.
When
the
piping
length
exceeds
20
m,
the
size
of
the
main
pipes
(the
gas
side
and
the
liquid
side)
must
be increased.
Please refer tothe
Engineering
quiet technology
Outdoor PCB automatically memorises the time when


Data Book
for details. operation sound, advanced
the peak outdoor temperature appears. It will enable
Without
increasing
thequiet
peakoperation
outdoor temperature
appears.
Itreturn
will enable
Without
increasing
operation
sound,toadvanced
mode after connected,
8 h*1, and
to normal
analytic
technologies
are
utilised
optimise
fan
*When a mixed combination of VRV and residential indoor units is connected or when only residential indoor units are *1
connection ratio
*2 , and return to normal
quiet
operation
mode

after
8
h
analytic
technologies
are
utilised
to
optimise
fan
mode Refer
aftertoitpage
keeps
9 h unit
. combination details.
design
increase
airflow
rate
andandhigh
must beand
50% to
130% for cooling
only
models
80% external
to 130% for heat pump models.
68 forfor
outdoor
mode after it keeps for 9 h*2.

design
increase airflow rate and high external
staticand
pressure.
*1 8 h is the initial setting with 6 h or 10 h also available.
Streamlined air grille
static pressure.
h isinitial
the initial
setting
h or
also available.
*1 8 *2
h is9 the
setting
with 6with
h or8 10
h 10
alsoh available.
Itpressure
promotes
discharge of
Streamlined
airthe
grille
High external static

swirling airflow,
furtherof
It promotes

the discharge
reducing
thefurther
swirling
airflow,
VRV IV outdoor unit has been
achieved
high
pressure
reducing
the loss.
external static pressure up pressure
to 78.4 loss.
Pa,

100

*2 9 h is the initial setting with 8 h or 10 h also available.
Peak in outdoor temperature
Night mode
Peak in outdoor temperature
Night mode

78.4 Pa
100

ensuring the efficient heat dissipation and
50
More options
50 in the

stable operation of equipmentStreamlined
in either scroll fan
The sharpscroll
edge fan
of each fan blade opening/angle of louvre
Streamlined
hierarchical or intensive arrangement.
0

200%
160%
130%

*1 For the FXFQ25LU,FXFQ-S and FXVQ models, maximum connection ratio is 130% for the
entire range of outdoor units.
Note: If the operational capacity of indoor units is more than 130%, low airflow operation is
enforced in all the indoor units.
*Refer to page 67-68 for outdoor unit combination details.



3.84 3.72 3.67
3.84 3.72 3.67

Operating Load Capacity
sound (dB)
(%)
(%)
Operating Load Capacity
sound (dB)

(%)
(%)

High-COP Type

The long piping length provides more design flexibility, which can match even large-sized buildings.

Main Features
Main Features
Main Features

Higher Coefficient of Performance (COP)
Higher
Coefficient of Performance (COP)
For mixed combination of VRV

Long
piping length
High-COP
Type



8 hrs

9 hrs

Outstanding heat
dissipation
a certain

Thehas
sharp
edge ofcurvature,
each fan reducing
blade
60
9 hrs
8 hrs
0
57
the vibration
and
the pressure effect in both
hasboth
a certain
curvature,
reducing
60 hierarchical and
VRV IV
57
intensive arrangement
50
bothloss.
the vibration and the pressure
VRV
IVdB(A)
Enable night mode
min. 40
50
loss.

40
Enable night mode
Streamlined
min. 40 dB(A)
8:00
8:00
12:00
16:00
20:00
0:00
4:00
40
scroll fan
Streamlined
8:00
8:00
12:00
16:00
20:00
0:00
4:00
scroll fan
Notes: · This function is available in setting at site.
· The
operating
soundininsetting
quiet operation
Notes: · This
function
is available

at site. mode is the actual value
Illustrated
by ourincompany.
· The measured
operating sound
quiet operation mode is the actual value
fan
Illustrated
· The relationship
of outdoor temperature (load) and time shown
measured
by our company.
fan
is justofanoutdoor
example.
· The above
relationship
temperature (load) and time shown
above is just an example.

Hotline: 0976 173 173

04
0408


Excellent
Operation
Performance
Reliable and

Stable Performance
System
Excellent
Operation
Enhanced
Lineup
to 3 types
Multiple advanced
features
more accurate test operation and stable system
Enhanced
Lineup
toensuring
3 types
High-COP Type

Cooling 4.5
4.41 4.30
Cooling
Operation
4.41
4.5
During
start-up,
Daikin4.30
VRV IV unit sequencing operation will be automatically enabled to
Operation
4
COP
3.72

3.84
ensure balanced
operation of each
outdoor
unit to3.67
improve longevity of equipment and stable
4
COP

Daikin VRV IV system incorporates a simplified and efficient test operation function, not only greatly
Enablesimproving
further energy
saving
accelerating the installationEnergy
process, but effectively
the field setting
quality as well.

Enables
energy
12 HP-50further
HP with
4 newsaving
models lineup
12 HP-50 HP with 4 new models lineup

Automatically checks the wirings between
outdoor units and indoor units to confirm
whether there is a defective wiring.
Confirms

20
HP and corrects the actual piping
length.
20
HP

VRV
VRV

Wiring
check
4.35
4.35
2.13 m2

COP during cooling operation 3.94
COP during
coolingSpace
operation 3.94
Installation
1.66 m2
2
Installation
Space
1.66
490mkg
Product Weight
490 kg
Product Weight


2.13
555mkg
2

Piping
555 kg
check

Automatically check whether the stop
valve in each outdoor unit is in normal
status to ensure the smooth operation of
air conditioning system.

Standard Type
Standard Type

10%
Increase
10
%

Increase

Stop valve
check

VRV
VRV

COP during cooling operation 3.94

COP during cooling operation 3.94 2
1.66 m
Installation Space
1.66 m2
Installation Space
Product Weight
490 kg
Product Weight
490 kg

3.94
3.94
1.42 m2

Simplified commissioning and after-sales service
20 HP
20
HP of information display
Function
by luminous digital tube

1.42 m2
380 kg
380 kg

7-segment digital display

14%
Decrease
14%

Decrease
22%
Decrease
22%
Decrease

Figures out
system
operation
luminous digital tubes to display system
Displays
information by
system
reading light
operation information, enabling the
emitting state
operational state to be visually displayed Newoperation
series
with
compact
&
lightweight
design
information
of different
New
series
with
compact
&

lightweight
design
Compact
whilst facilitating simplified
directly HP with 17 new models
18 HP-50
lineup
diodes, which
Compact
Design service. 18 HP-50 HP with 17 new models
commissioning and after-sales
is both lineup
Design
inefficient and
fallible.

Space Saving Type
Space Saving Type

VRV configurator

20 HP
20 HP

3.11
3.11 2

The VRV configurator is an advanced software solution
that allows for easy system configuration and
commissioning.


Lineup
Lineup
less time is required on the roof configuring the outdoor
unit. HP

HP
High-COP Type
multiple
systems at different sites can be managed in
High-COP Type
exactly the
Standard
Typesame way, thus offering simplified
Standard
Type
commissioning
for key accounts.
Space Saving Type
Space Saving Type

0.95 m
0.95 m2
320 kg
320 kg

Simplified
commissioning
Mo/C
Mo/C


Retrieve initial
system settings



3.25
3.25

6 HP
8 HP 10 HP * 12 HP 14 HP 16 HP 18 HP
6 HP
8 HP 10 HP * 12 HP 14 HP 16 HP 18 HP

Ease of installation
Ease
Priority:of installation

operation.

*Cooling3operation conditions: Indoor temp. of
Stage
*Cooling
operation
conditions:
Indoor temp. of 35ºCDB.
27ºCDB,
19ºCWB,
and outdoor
27ºCDB,

19ºCWB,
outdoor more
temp.compact
of 35ºCDB.
*12 HP
of VRV and
IV improves
*12 HP
of VRV
IV more
improves
more
compact
design
and
saving
space
than VRV III
design and more saving space than VRV III

Automatic
sequencing

Automatic
sequencing

Priority:

Priority:
VRV

12 HP
VRV
12 HP

Installation
Installation
Space
Space
0.95 m2
0.95 m2

43%
Decrease
43%
Decrease
35%
Decrease
35%
Decrease

1,240 mm
1,240 mm

765
mm

765
mm

930 mm

930 mm

VRV
12 HP
VRV
12 HP

Double backup operation functions

12 HP
12 HP
Installation
25%
Installation
Space
25Decrease
%
Space
2
0.71 m
Decrease
0.71 m2

Product
Product
Weight
Weight
285 kg
285 kg


Product
Product
Weight
Weight
195 kg
195 kg

32%

765
mm

12 HP
12 HP

even
if failure
occurs insound
a set of air conditioning equipment.
Sound level(dB(A))
Lower
operation
Sound level(dB(A))
Lower
operation
sound
In the event
of a failure,
emergency operation can6 HP
be conveniently

enabled
the remaining system
8 HP
10 HP to allow
12 HP
to
operate
in aexchanger
limited fashion.
Improve
heat
Improve
heathelps
exchanger
efficency,
to reduced
efficency,
helps
to reduced
operation
sound.
operation sound.

6 HP
57
57
55
55

8 HP

57
57
56
56

10 HP
58
58
57
57

12 HP
60
60
59
59

1˜ 2 dB(A) reduction than
conventional
1˜ 2 dB(A)
reductionmodel
than
conventional model

Unit backup operation function
Large airflow, high static pressure and
Nighttime quiet operation function
If malfunction
in an outdoor
Large

airflow,
high occurs
static pressure
and unit...
Nighttime quiet operation function
quiet
technology
Outdoor PCB automatically memorises the time when
operation can be conveniently set and enabledOutdoor PCB automatically memorises the time when
quietEmergency
technology
the peak outdoor temperature appears. It will enable
Without increasing operation sound, advanced
by
the
remote
controller
for
indooradvanced
unit (for systems
thequiet
peakoperation
outdoor temperature
will enable
Without
increasing
operation
sound,
mode after appears.
8 h*1, andItreturn

to normal
analytic
technologies
are utilised
to optimise fan
composed
of two are
or more
outdoor
units ).fan
quiet operation mode after 8 h*2*1, and return to normal
analytic
technologies
utilised
to optimise
design and increase airflow rate and high external
design
increase airflow rate and high external
staticand
pressure.
Streamlined air grille
static pressure.
It promotes
discharge of
Streamlined
airthe
grille
swirling airflow,
furtherof
It promotes

the discharge
reducing
thefurther
swirling
airflow,
pressure
reducing
the loss.
pressure loss.

Compressor backup operation
function
Streamlined scroll
fan
New Lineup
New Lineup

765
mm

Comfort
Daikin VRV IV system boasts double backup operation functions, which can secure the use of air
Comfort
conditioners in this area to the greatest extent by emergently enabling double backup operation functions

The sharpscroll
edge fan
of each fan blade
Streamlined


If malfunction occurs
in
compressor...
aacertain
Thehas
sharp
edge ofcurvature,
each fan reducing
blade
both
the vibration
and
the
pressure
a certain
curvature,
reducing
Emergency operationhascan
be
easily
set
and
bothloss.
the vibration and the pressure
enabled by the outdoor
loss.unit (for a single
Streamlined
outdoor unit system RX(Y)Q14-20TY1
models).
scroll fan

Streamlined
scroll fan

Illustrated
fan
Illustrated
fan

Initial settings on the outdoor unit can be easily retrieved.

03
0309

3.46
3.46

32Decrease
%
Double backup operation functions responding resiliently to various unexpected situations
Decrease

VRV IV system utilises 7-segment

COP during cooling operation 3.94
COP during cooling operation 3.94 2
1.66 m
Installation Space
1.66 m2
Installation Space
Product Weight

490 kg
Product Weight
490 kg

Stage 2

Highly-integrated VRV Ⅳ
Highly-integrated
VRV Ⅳ
system offers compact
system
offers
compact
outdoor
units
to achieve
outdoor
unitsutilisation
to achieveof the
maximum
maximum
utilisation
installation space.of the
installation space.

Conventional LED display

VRV
VRV


3.67

Compact & lightweight design
Compact & lightweight design

Offers higher capacity of up to 60 HP
Offers
higher
capacity
up to 60
HP
6 HP-60
HP with
3 newofmodels
lineup
6 HP-60 HP with 3 new models lineup

Up to
Up
60 to
HP
60 HP

3.72

3.84



mode after it keeps for 9 h .

mode after it keeps for 9 h*2.

Operating Load Capacity
sound (dB)
(%)
(%)
Operating Load Capacity
sound (dB)
(%)
(%)

Automatic check

3.5
3.5
Stage 1 3
3
0
0

Main Features
Main Features
Main Features

Higher Coefficient of Performance (COP)
Higher
Coefficient
of Performance
Automatic
sequencing

operation (COP)

Efficient
automatic
test operation
High-COP
Type
Energy
Saving
Saving

Energy saving
Energy saving
Outdoor
unit sequencing technology

100

100

*1 8 h is the initial setting with 6 h or 10 h also available.
h isinitial
the initial
setting
h or
also available.
*1 8 *2
h is9 the
setting
with 6with

h or8 10
h 10
alsoh available.
*2 9 h is the initial setting with 8 h or 10 h also available.
Peak in outdoor temperature
Night mode
Peak in outdoor temperature
Night mode

50

50

0
60

57
50

40

8 hrs
8 hrs

0
60

57
50


40

8:00

8:00

9 hrs

9 hrs

VRV IV

VRV
IVdB(A)
Enable night mode
min. 40
Enable night mode
min. 40 dB(A)
12:00

12:00

16:00

16:00

20:00

20:00


0:00

0:00

4:00

4:00

8:00

8:00

Notes: · This function is available in setting at site.
· The
operating
soundininsetting
quiet operation
Notes: · This
function
is available
at site. mode is the actual value
by ourincompany.
· The measured
operating sound
quiet operation mode is the actual value
· The relationship
of outdoor temperature (load) and time shown
measured
by our company.
is justofanoutdoor

example.
· The above
relationship
temperature (load) and time shown
above is just an example.

Hotline: 0976 173 173

04
0410


Enhanced
Lineup
to 3 types compressor in compact casing
Large
capacity
all DC
Enhanced
Lineup
to 3inverter
types

Cooling 4.5
4.41 4.30
Cooling
Operation
4.41technology
SMT4.5
packaging

4.30 adopted by the
Operation
4
COP
whole computer
control panel improves
the
3.84 3.72
4
COP

Enables further energy saving
Enables
energy
12 HP-50further
HP with
4 newsaving
models lineup
12 HP-50 HP with 4 new models
lineup
Small type
high efficiency

concentrated winding motor
VRV
VRV

winding
COP during cooling operation Distributed
% motor

3.94 winding motor
4.35 Concentrated10
(New 12 HP
compressor)
(Current 8 HP compressor)
Increase
COP during
cooling
operation
10
%
3.94
4.35
2
2
Installation Space
1.66 m
2.13 m
Increase
2
2
Installation
Space
1.66
2.13
490mkg
555mkg
Product Weight
490 kg
555 kg

Product Weight

20 HP
20 HP

Coil
end

Standard Type
Standard Type

Offers higher capacity of
up to 60
HP
Small
coilHP
end using concentrated
Offers
higher
capacity
upsizing
to 60
6 HP-60
HP with
3 newofwinding,
models
lineup
reduce copper loss
6 HP-60 HP with 3 new models
lineup

(winding resistance).

Up to
Up
60 to
HP
60 HP

VRV
VRV
Improve motor efficiency in low rpm

COP during cooling operation range
3.94(improve intermediate
3.94
14%
COP during cooling operation 3.94
3.94
Decrease
efficiency).
14%
1.42 m2
1.66 m2
Installation Space
Decrease
1.42 m2
1.66 m2
Installation Space
22%
Product Weight

490 kg
380 kg
Decrease
22%
Product Weight
490 kg
380 kg
Decrease

As a result of having thinned a wall -

20
HP of the scroll, compression
thickness
20
HP volume increase 50%
chamber

Space Saving Type
Space Saving Type

Highly integrated heat New
exchanger
series with compact & lightweight design

New
seriesHP
with
compact
lightweight

design
Compact
18 HP-50
with
17 new&models
lineup
Compact
18 HP-50 HP with 17 new models lineup
Design
Improve performanceDesign
by increasing heat exchanger area while maintaining
VRVthe same installation space.

VRV

Realise
highlyoperation
integrated heat
performance
COP during
cooling
3.94exchanger 3.11
43%
(increase
row,
reduce fin3.94
pitch) by
reducing
of airflow Decrease
3.11

COP during
cooling
operation
43%
0.95 m2
1.66 m2
Installation
Space
resistance which changes cooling
tube to Ø7.2
Decrease
35%
0.95 m
1.66 m2
Installation Space
Product Weight
490 kg
320 kg
Decrease
35%
Product Weight
490 kg
320 kg
Decrease

VRV

20 HP
20 HP
Lineup

Lineup
HP
HP
High-COP Type
High-COP Type
Standard Type
Standard Type
Space SavingFine
TypeLouvre Fin
Space Saving Type

03
0311

Mo/C
Mo/C

New Lineup
New Lineup

20 HP

3 row with small pipe design,
increases heat transfer efficiency
Waffle Fin

Change fin shape from fine louvre to waffle fin.
Fin pitch can be reduced fin pitch from 2.0 mm to 1.4 mm, to realise unit
efficiency which increased heat exchanger area.


10 HP
16 HP

Heat exchanger Contribution of COP
area
(cooling)

13%UP
24%UP



105.5%
111.5%

Computer control board surface
adopting SMT packaging
technology

Ease of installation
Ease of installation
Highly-integrated VRV Ⅳ
Highly-integrated
VRV Ⅳ
system offers compact
system
offers
compact
outdoor
units

to achieve
outdoor
unitsutilisation
to achieve
Refrigerant
cooling
maximum
of the technology,
maximum
utilisation
installation space.of the
installation space.
1,240 mm

*Cooling operation conditions: Indoor temp. of
*Cooling
operation
conditions:
Indoor temp. of 35ºCDB.
27ºCDB,
19ºCWB,
and outdoor
27ºCDB,
19ºCWB,
outdoor more
temp.compact
of 35ºCDB.
*12 HP
of VRV and
IV improves

*12 HP
of VRV
IV more
improves
more
compact
design
and
saving
space
than VRV III
design and more saving space than VRV III

SMT
packaging
material

Computer control board

Compact & lightweight design
Compact & lightweight design

Conventional
computer control
board surface

3.67

3.84 3.72 3.67
3.46

anti-clutter
3.5 performance.
3.25
3.46
3.5
3.25
Protects3your computer boards from the
3
adverse 0effect of sandy and humid weather.
0
6 HP
8 HP 10 HP * 12 HP 14 HP 16 HP 18 HP
6 HP
8 HP 10 HP * 12 HP 14 HP 16 HP 18 HP

VRV
12 HP
*SMT: Surface mounted
technology
VRV
12 HP

Installation
Installation
Space
Space
0.95 m2
0.95 m2

12 HP

12 HP
Installation
25%
Installation
Space
25Decrease
%
Space
2
0.71 m
Decrease
0.71 m2

ensures stability of PCB temperature
765
mm

765
mm

765
765
Improved inner design1,240
tomm
increase
smooth airflow
mm
mm
930 mm
930 mm


VRV
12 HP
VRV
12 HP

12 HP
12 HP

Downsize electric component, re-locate to dead
space of bell mouth side to decrease airflow resistance.

Product
Product
Weight
Weight
285 kg
285 kg

Product
Product
Weight
Weight
195 kg
195 kg

32%
32Decrease
%


Decrease

Bell mouth

Comfort
Comfort

Lower operation sound
Lower operation sound
Improve heat exchanger
Improve
heathelps
exchanger
efficency,
to reduced
efficency,
helps
to reduced
operation sound.
operation sound.

6 HP
6 HP
57
57
55
55

VRV


Large airflow, high static pressure and
Large
high static pressure and
quietairflow,
technology
quiet technology

8 HP
8 HP
57
57
56
56

Sound level(dB(A))
Electric Component Space
Sound level(dB(A))

10 HP
10 HP
58
58
57
57

12 HP
12 HP
60
60
59

59

1˜ 2 dB(A) reduction than
conventional
1˜ 2 dB(A)
reductionmodel
than
conventional model

Nighttime quiet operation function
Nighttime quiet operation function

Without increasing operation sound, advanced
Without
increasing
operation
sound,toadvanced
analytic
technologies
are utilised
optimise fan
analytic
are
utilised
to and
optimise
fan
designtechnologies
and increase
airflow

rate
high external
design
and
increase
airflow
rate
and
high
external
static pressure.
Streamlined air grille
static pressure.
It promotes
discharge of
Streamlined
airthe
grille
swirling airflow,
furtherof
It promotes
the discharge
reducing
thefurther
swirling
airflow,
pressure
reducing
the loss.
pressure loss.


Streamlined scroll fan
Roof terrace temperature Streamlined
in summer
isscroll
over fan
40each
C, seriously
The sharp
edge
of
fan blade
affecting inverter coolingThe
efficiency,
resulting
infan
decline
has
a certain
reducing
sharp
edge
ofcurvature,
each
bladeof
inverter operating speed.
device
parts
response
both

the
vibration
and
the pressure
hasFinally
a certain
curvature,
reducing
both
the vibration and the pressure
speed
isloss.
reduced.
loss.
Streamlined
scroll fan
Streamlined
fan ambient temperature
Improve reliability atscroll
high

Outdoor PCB automatically memorises the time when
Outdoor
PCBoutdoor
automatically
memorises
the time
the peak
temperature
appears.

It willwhen
enable
thequiet
peakoperation
outdoor temperature
will enable
mode after appears.
8 h*1, andItreturn
to normal
*1
quiet
operation
mode
after itmode
keepsafter
for 98 hh*2., and return to normal
mode after it keeps for 9 h*2.

Operating Load Capacity
sound (dB)
(%)
(%)
Operating Load Capacity
sound (dB)
(%)
(%)

Gives 2.4 times tensile strength compare
to conventional material
New Material: 600 MPa

Conventional Material : 250 MPa
Increase compression chamber volume
by using thin spiral design.

Energy saving
Energy
Varioussaving
advanced control main PC board
Higher Coefficient of Performance (COP)
Higher
Coefficient
of Performance (COP)
SMT* packaging
technology

High-COP Type
High-COP Type

Large capacity inverter compressor using high tension strength material,
realise 12 HP compressor using 8 HP casing.

Energy
Energy
Saving
Development of high Saving
strength material

Excellent Performance

Main Features

Main Features
Main Features

Excellent
Operation
Performance
Advanced
Technologies
Achieve
Excellent
Operation
Performance

100

100

*1 8 h is the initial setting with 6 h or 10 h also available.
h isinitial
the initial
setting
h or
also available.
*1 8 *2
h is9 the
setting
with 6with
h or8 10
h 10
alsoh available.

*2 9 h is the initial setting with 8 h or 10 h also available.
Peak in outdoor temperature
Night mode
Peak in outdoor temperature
Night mode

50

50

0
60

57
50

40

9 hrs

8 hrs

Control board failure
ratio at stable
operation
9 hrs
8 hrs
is reduced.

0

60

57
50

40

8:00

8:00

VRV IV

VRV
IVdB(A)
Enable night mode
min. 40
Enable night mode
min. 40 dB(A)
12:00

12:00

16:00

16:00

20:00

20:00


0:00

0:00

4:00

4:00

Notes: · This function is available in setting at site.

8:00

8:00

· The
operating
soundininsetting
quiet operation
Notes: · This
function
is available
at site. mode is the actual value
It is possible to cool theIllustrated
inverter power module stability
even
at
high
ambient
temperature.

by ourincompany.
· The measured
operating sound
quiet operation mode is the actual value
fan
Illustrated
This helps to keep air-conditioning
capacity and also reduces
failure
ratio.
· The
relationship
of outdoor temperature (load) and time shown
measured
by our
company.
fan



is justofanoutdoor
example.
· The above
relationship
temperature (load) and time shown
above is just an example.

Hotline: 0976 173 173

04

0412


Outdoor
Outdoor Unit
Unit Lineup
Lineup
Outdoor
OutdoorUnits
Units

Cooling
CoolingOnly
Only/ Heat
/ HeatPump
Pump
Lineup
Lineup

VRV
VRV
IV IV
outdoor
outdoor
unit
unit
offers
offers
a higher
a higher

capacity
capacity
of of
upup
to to
6060
HP,
HP,
responding
responding
to to
thethe
needs
needs
of of
large-sized
large-sized
building.
building.
The
The
single
single
outdoor
outdoor
unit
unit
has
has
only

only
2 different
2 different
shapes
shapes
and
and
dimensions,
dimensions,
notnot
only
only
simplifying
simplifying
thethe
design
design
process,
process,
butbut
also
also
bringing
bringing
thethe
system
system
flexibility
flexibility
to to

a new
a new
level.
level.
With
With
thethe
outdoor
outdoor
unit
unit
capacity
capacity
increased
increased
in in
increment
increment
of of
2 HP,
2 HP,
customers'
customers'
needs
needs
can
can
bebe
precisely
precisely

met.
met.
Outdoor
Outdoor
units
units
with
with
anti-corrosion
anti-corrosion
specifications
specifications
(-E(-E
type
type
onon
request)
request)
areare
designed
designed
specifically
specifically
forfor
use
use
in in
areas
areas
which

which
areare
subject
subject
to to
salt
salt
damage
damage
and
and
atmospheric
atmospheric
pollution.
pollution.

High-COP
High-COPType
Type

Triple
TripleOutdoor
OutdoorUnits
Units

Double
DoubleOutdoor
OutdoorUnits
Units
12,12,

14,14,
1616
HPHP

RX(Y)Q26THY1(E)
RX(Y)Q18THY1(E)
RX(Y)Q18THY1(E)RX(Y)Q26THY1(E)
RX(Y)Q28THY1(E)
RX(Y)Q20THY1(E)
RX(Y)Q20THY1(E)RX(Y)Q28THY1(E)
RX(Y)Q30THY1(E)
RX(Y)Q22THY1(E)
RX(Y)Q22THY1(E)RX(Y)Q30THY1(E)
RX(Y)Q32THY1(E)
RX(Y)Q24THY1(E)
RX(Y)Q24THY1(E)RX(Y)Q32THY1(E)

RX(Y)Q12THY1(E)
RX(Y)Q12THY1(E)
RX(Y)Q14THY1(E)
RX(Y)Q14THY1(E)
RX(Y)Q16THY1(E)
RX(Y)Q16THY1(E)

Standard
StandardType
Type
6, 6,
8, 8,
10,10,

1212
HPHP

RX(Y)Q6TY1(E)
RX(Y)Q6TY1(E)
RX(Y)Q8TY1(E)
RX(Y)Q8TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q12TY1(E)
RX(Y)Q12TY1(E)

14,14,
1616
HPHP

RX(Y)Q14TY1(E)
RX(Y)Q14TY1(E)
RX(Y)Q16TY1(E)
RX(Y)Q16TY1(E)

Space
SpaceSaving
SavingType
Type

Single
SingleOutdoor
OutdoorUnits
Units

18,18,
2020
HPHP

RX(Y)Q18TY1(E)
RX(Y)Q18TY1(E)
RX(Y)Q20TY1(E)
RX(Y)Q20TY1(E)

1313

18,18,
2020
HPHP

RX(Y)Q18TNY1(E)
RX(Y)Q18TNY1(E)
RX(Y)Q20TNY1(E)
RX(Y)Q20TNY1(E)

22,22,
24,24,
2626
HPHP

RX(Y)Q22TNY1(E)
RX(Y)Q22TNY1(E)
RX(Y)Q24TNY1(E)
RX(Y)Q24TNY1(E)
RX(Y)Q26TNY1(E)

RX(Y)Q26TNY1(E)

28,28,
30,30,
3232
HPHP

RX(Y)Q22TSY1(E)
RX(Y)Q22TSY1(E)
RX(Y)Q24TSY1(E)
RX(Y)Q24TSY1(E)

Space
Space
Saving
Saving
Type
Type

34,34,
3636
HPHP

RX(Y)Q28TNY1(E)
RX(Y)Q28TNY1(E)
RX(Y)Q30TNY1(E)
RX(Y)Q30TNY1(E)
RX(Y)Q32TNY1(E)
RX(Y)Q32TNY1(E)


Double
DoubleOutdoor
OutdoorUnits
Units
22,22,
2424
HPHP

Standard
Standard
Type
Type

42,42,
44,44,
46,46,
48,48,
5050
HPHP

RX(Y)Q42THY1(E)
RX(Y)Q42THY1(E)RX(Y)Q48THY1(E)
RX(Y)Q48THY1(E)
RX(Y)Q44THY1(E)
RX(Y)Q44THY1(E)RX(Y)Q50THY1(E)
RX(Y)Q50THY1(E)
RX(Y)Q46THY1(E)
RX(Y)Q46THY1(E)

Triple

TripleOutdoor
OutdoorUnits
Units

Double
DoubleOutdoor
OutdoorUnits
Units

Single
SingleOutdoor
OutdoorUnits
Units

High-COP
High-COP
Type
Type

RX(Y)Q36THY1(E)
RX(Y)Q36THY1(E)
RX(Y)Q40THY1(E)
RX(Y)Q40THY1(E)

RX(Y)Q34THY1(E)
RX(Y)Q34THY1(E)
RX(Y)Q38THY1(E)
RX(Y)Q38THY1(E)

New

New
Lineup
Lineup

HPHP

36,36,
4040
HPHP

34,34,
3838
HPHP

18,18,
20,20,
22,22,
24,24,
26,26,
28,28,
30,30,
3232
HPHP

Mo/C
Mo/C

Outdoor Unit Lineup
Outdoor Unit Lineup


The
Theoutdoor
outdoorunit
unitcapacity
capacityisisup
uptoto6060HP
HPininincrement
incrementofof2 2HP.
HP.

RX(Y)Q34TNY1(E)
RX(Y)Q34TNY1(E)
RX(Y)Q36TNY1(E)
RX(Y)Q36TNY1(E)

34,34,
36,36,
38,38,
4040
HPHP

RX(Y)Q26TSY1(E)
RX(Y)Q26TSY1(E)RX(Y)Q30TSY1(E)
RX(Y)Q30TSY1(E)
RX(Y)Q28TSY1(E)
RX(Y)Q28TSY1(E)RX(Y)Q32TSY1(E)
RX(Y)Q32TSY1(E)




RX(Y)Q34TSY1(E)
RX(Y)Q34TSY1(E)RX(Y)Q38TSY1(E)
RX(Y)Q38TSY1(E)
RX(Y)Q36TSY1(E)
RX(Y)Q36TSY1(E)RX(Y)Q40TSY1(E)
RX(Y)Q40TSY1(E)



RX(Y)Q42TNY1(E)
RX(Y)Q42TNY1(E)
RX(Y)Q44TNY1(E)
RX(Y)Q44TNY1(E)

RX(Y)Q38TNY1(E)
RX(Y)Q38TNY1(E)
RX(Y)Q40TNY1(E)
RX(Y)Q40TNY1(E)

Double
DoubleOutdoor
OutdoorUnits
Units
26,26,
28,28,
30,30,
3232
HPHP

42,42,

4444
HPHP

38,38,
4040
HPHP

46,46,
48,48,
50,50,
52,52,
54,54,
56,56,
58,58,
6060
HPHP

RX(Y)Q54TNY1(E)
RX(Y)Q46TNY1(E)
RX(Y)Q46TNY1(E)RX(Y)Q54TNY1(E)
RX(Y)Q56TNY1(E)
RX(Y)Q48TNY1(E)
RX(Y)Q48TNY1(E)RX(Y)Q56TNY1(E)
RX(Y)Q58TNY1(E)
RX(Y)Q50TNY1(E)
RX(Y)Q50TNY1(E)RX(Y)Q58TNY1(E)
RX(Y)Q60TNY1(E)
RX(Y)Q52TNY1(E)
RX(Y)Q52TNY1(E)RX(Y)Q60TNY1(E)


Triple
TripleOutdoor
OutdoorUnits
Units
42,42,
4444
HPHP

RX(Y)Q42TSY1(E)
RX(Y)Q42TSY1(E)
RX(Y)Q44TSY1(E)
RX(Y)Q44TSY1(E)

46,46,
48,48,
5050
HPHP

RX(Y)Q46TSY1(E)
RX(Y)Q46TSY1(E)
RX(Y)Q48TSY1(E)
RX(Y)Q48TSY1(E)
RX(Y)Q50TSY1(E)
RX(Y)Q50TSY1(E)

Hotline: 0976 173 173

1414



Indoor
Indoor Unit
Unit Lineup
Lineup
VRV Indoor
Units
Enhanced
Enhanced
range
range
ofofchoices
choices
AA
mixed
mixed
combination
combination
ofof
VRV
VRV
indoor
indoor
units
units
and
and
residential
residential
indoor
indoor

units
units
Ceiling
Mounted
Cassette
Corner
Type
is is
enabled
enabled
allall
in in
one
one
system.
system.
Opening
Opening
the
the
door
door
toto
stylish
stylish
and
and
quiet
quiet
indoor

indoor
units.
units.

Slim Ceiling Mounted Duct Type

VRV
VRV
indoor
indoor
units
units

FXKQ25MA / FXKQ32MA

Residential
Residential
indoor
indoor
units
units
with
with
connection
connection
toto
BP
BP
units
units


Slim Model
design,
quietness
and
2.0
2.0
kWkW
Rated
Capacity
Capacity
Model
Name
Name Rated
Capacity
Capacity
Index
Index
2020
static pressure switching
20 20

Type
Type

Model
Model
Name
Name


FXKQ40MA / FXKQ63MA
FXFQ-SVM
FXFQ-SVM

Min.195 mm
Panel spacer
20 mm

Single-flow type allows effective air discharge
from corner or from drop-ceiling.
Drain pump is equipped as standard
accessory with 500 mm lift.

2

28˚C
32˚C 30˚C

FFQ-BV1B
FFQ-BV1B

2

3

71 71

2.52.5
kWkW


3.53.5
kWkW

5.05.0
kWkW

6.06.0
kWkW

7.17.1
kWkW

2525

3535

5050

6060

7171

FBQ-BV1
FBQ-BV1

FXDQ40NB / FXDQ50NB / FXDQ63NB

Cooling
Cooling
OnlyOnly

FDKS-EAVMB
FDKS-EAVMB

(900/1,100
(900/1,100
mmmm
width
width
type)type)
HeatHeat
Pump
PumpFDXS-CVMA
FDXS-CVMA

24˚C

Cooling
Cooling
OnlyOnly
FTKS-DVM
FTKS-DVM
Great
for
FTXS-DVMA
FTXS-DVMA
hotel
use!
HeatHeat
Pump
Pump


Wall
Wall
Mounted
Mounted

22˚C

5

Cooling
Cooling
OnlyOnly
FTKS-BVMA
FTKS-BVMA

200 mm

Cooling
Cooling
OnlyOnly
FTKS-FVM
FTKS-FVM

Only

700 mm

* 1,100 mm in width for the FXDQ63NB model.


Note:
Note:
BPBP
units
units
areare
necessary
necessary
for for
residential
residential
indoor
indoor
units.
units.
Only
Only
single
single
outdoor
outdoor
unitunit
(RX(Y)Q6-20TY1)
(RX(Y)Q6-20TY1)
cancan
be be
connected.
connected.
Suspension bolt*


AIR

Downward discharge

6464

* To be obtained locally

10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.
15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

Set for front discharge using a suspended ceiling.

FXDQ-PB and FXDQ-NB models are available in two
types to suit different installation conditions.

Main body

Control of the airflow rate has been improved from 2-step
to 3-step control.

BPBP
unit
unit

Air discharge grille
(Option)

Low operation sound level


FXVQ-MY1
FXVQ-MY1

FXDQ-PB/NB
Downward discharge is shut off and air is blown straight out
(front discharge).

A long-life filter (maintenance free up to one
year*) is equipped as standard accessory.

Daikin
Daikin
airair
handing
handing
units
units
can
can
bebe
connected
connected
to to
VRV
VRV
IV IV
system.
system.
Please
Please

refer
refer
to to
page
page
103
103
and
and
contact
contact
your
your
local
local
sales
sales
office
office
forfor
details.
* details.
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3



Suction grille *

External static pressure selectable by remote controller
switching make this indoor unit a very comfortable and

flexible
model.
VRV
VRVindoor
indoorunits
unitsonly
only

Max.
Max.
indoor
indoor
units
units

25
1515

240 mm

Discharge grille *

Air discharge grille (Option)

FXVQ-MY16
FXVQ-MY16

Air filter

AIR


Main body

(high(high
staticstatic
pressure
pressure
type)type)

200 mm

900 mm

HeatHeat
Pump
PumpFTXS-FVMA
FTXS-FVMA

6 (m)

Front discharge is possible with an air
discharge unit (option), which allows the
installation in the drop-ceiling or sagging wall.

500 mm

Only 200 mm in height, this model can be installed in
rooms with as little as 240 mm depth between the
drop-ceiling and ceiling slab.


FTXS-EVMA
FTXS-EVMA

26˚C

4

60 60

Only
700
mm
in width and
23mm
kg
in type)
weight, this
(700(700
mm
width
width
type)
HeatHeat
Pump
Pump
CDXS-EAVMA
CDXS-EAVMA
Slim
Slim
Ceiling

Ceiling
Mounted
Mounted
Duct
Duct model is suitable to install in limited spaces like
Cooling
Cooling
OnlyOnly
FDKS-C(A)VMB
FDKS-C(A)VMB
drop-ceilings in hotels.

20˚C
1

50 50

FXDQ20PB / FXDQ25PB / FXDQ32PB

1
0

Ceiling
Ceiling
Mounted
Mounted
Cassette
Cassette
(Compact
(Compact

MultiMulti
Flow)
Flow)
Ceiling
Ceiling
Mounted
Mounted
Built-in
Built-in

Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism realises even
distribution of airflow and room temperature.
(m)
3

FCQ-BVE
FCQ-BVE

35 35

Suited to use in drop-ceilings!

Slim design for flexible installation
Slim body needs only 220 mm space above the
ceiling. If you use a panel spacer (option), the
unit can be installed in the minimum space of
195 mm.


Ceiling
Ceiling
Mounted
Mounted
Cassette
Cassette

8 types
8 types
2323
models
models

25 25

Indoor Unit Lineup
Indoor Unit Lineup

Type
Type

1818
types
types
8686
models
models

20/25/32


(dB(A))
40

50

63

Sound level
33/31/29
34/32/30
35/33/31
36/34/32
(HH/H/L)
Max.
Max.
indoor
* Theindoor
values
of operation sound level represent those for rear-suction operation.
units
units
Sound
level values for bottom-suction operation can be obtained by adding 5 dB(A).

3232

FXDQ-PB/NBVE: with a drain pump (750 mm lift)
as a standard accessory
FXDQ-PB/NBVET: without a drain pump


Residential
Residentialindoor
indoorunits
units

750 mm

VRV
VRVindoor
indoorunits
units
Ceiling

* Values are based on the following conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
of 15 Pa.

*Refer
*Refer
to page
to page
67-68
67-68
for for
thethe
maximum
maximum
number
number
of connectable

of connectable
indoor
indoor
units.
units.



Hotline: 0976 173 173

1626
16


Indoor
Indoor Unit
Unit Lineup
Lineup
VRV Indoor Units

Daikin offers a wide range of indoor units includes both VRV and residential
models responding to variety of needs of our customers that require
Ceiling Mountedsolutions.
Cassette Corner Type
air-conditioning

VRV Indoor
Units
FXKQ25MA / FXKQ32MA


FXHQ-MAVE

FXAQ-PVE

Slim Ceiling Mounted Duct Type

Slim design, quietness and
Stylish flat panel design
harmonised with your interior
static pressure switchingdécor

Slim body with quiet and wide
airflow

Ceiling Mounted Cassette
(Round Flow) Type

(Round Flow with Sensing)
Type

Wall Mounted Type

Floor Standing Type

FXFQ-LUV1

FXLQ-MAVE

FXFQ-SVM


Slim design for flexible installation

Presence of people and floor
temperature
be needs
detected
to 220 mm space above the
Slimcan
body
only
provide ceiling.
comfort and
energy
savings
If you use a panel spacer (option), the

360 airflow improves temperature
distribution
and offers
a comfortable
Providing
3 different
settings of standard, draft
living prevention
environment. and ceiling soiling prevention, the

Ceiling
Mounted
Cassette
195

mm.
(Compact Multi Flow) Type

4-Way
Flow Ceiling
distribution
of airflow and room temperature.
Suspended Type

FXZQ-MVE

FXUQ-AVEB

unit can be installed in the minimum space of

Min.195 mm

auto swing mechanism realises even

Panel spacer

2

20 mm

Single-flow type allows effective air discharge
from corner or from drop-ceiling.

Quiet, compact, and designed for
user comfort


Drain pump is equipped as standard
accessory with 500 mm lift.

Ceiling Mounted Cassette
(Double Flow) Type
FXCQ-MVE

500 mm

(m)
3

28˚C
32˚C 30˚C

26˚C

1

24˚C

Suited to use in drop-ceilings!

Concealed Floor
Standing
FXDQ20PB
/ FXDQ25PB / FXDQ32PB
Type


20˚C

Only 700 mm in width and 23 kg in weight, this
Only 200 mm in height, this model can be installed in
model is suitable to install in limited spaces like Large airfiow type for large spaces.
roomsdesign
with as
240 mm depth between the
Flexible interior
forlittle
eachastenant.
Suitable for perimeterdrop-ceilings
zone air conditioning
in hotels.
drop-ceiling and ceiling slab.
Great for

hotelIndoor
use!
Residential
Units

Only

FCQ-BVE

discharge unit (option), which allows the
installation in the drop-ceiling or sagging wall.

Ceiling Mounted Cassette

body
CornerMain
Type

Downward discharge

FXDQ40NB / FXDQ50NB / FXDQ63NB

FXNQ-MAVE

with connection to BP units

Ceiling Mounted Cassette
Type

22˚C

This slim and stylish
indoor
unit3
0
1
2
4
5
6 (m)
achieves optimum air distribution,
and can be installed without the
Front
discharge

need for
ceiling
cavity. is possible with an air

FXKQ-MAVE

Floor Standing Duct Type

FXVQ-MY1
FXVQ-MY16
(high static pressure type)

Ceiling Mounted Cassette

200 mm

200 mm(Compact Multi900
Flow)
mmType

700 mm

FFQ-BV1B

* 1,100 mm in width for the FXDQ63NB model.

Suspension bolt*

Specially designed for false ceilings
—for a smooth, modern interior finish


Quiet, compact, and designed for user
AIR
comfort

Ceiling Mounted Built-in
Type

Slim Ceiling Mounted Duct Type

Air filter

240 mm

Discharge grille *

Cooling Only

AIR

Suction grille *

FDKS-EAVMB
FDKS-C(A)VMB

FBQ-BV1

Indoor Unit Lineup
Indoor Unit Lineup


FXKQ40MA
/ FXKQ63MA
Ceiling Mounted
Cassette

Ceiling Suspended Type

* To be obtained locally

External static pressure selectable by remote controller
switching make this indoor unit a very comfortable and
CDXS-EAVMA
flexible model.

Air discharge grille (Option)

Heat Pump

FDXS-CVMA
10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.
Set for front
Slim design
for discharge
flexibleusing a suspended ceiling.
installation Main body

Flexible air discharge unit to fit
various forms of space

Slim Ceiling Mounted Duct

Type

Ceiling Mounted Duct
Type

Wall Mounted
Type
Control
of the airflow rate has been improved from 2-step

FXDQ-PBVE(T)

FXMQ-PVE

FXDQ-NBVE(T)

Downward discharge is shut off and air is blown straight out
FXMQ-MAVE

Slim design, quietness and
static pressure switching

High external
static
pressureas standard accessory.
year*) is
equipped
allows
flexible
installations

* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

(front discharge).

A long-life filter (maintenance free up to one



to 3-step control.

Cooling Only

FTKS-DVM
FTKS-BVMA Low operation sound level
FTKS-FVM
FXDQ-PB/NB
20/25/32

Air discharge grille
(Option)

Heat Pump

1725

15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

Slim and smooth design suits your
shallow ceiling
FXDQ-PB and FXDQ-NB models are available in two

types to suit different installation conditions.

Thin, lightweight, and easy to install
in narrow ceiling spaces

FTXS-DVMA
FTXS-EVMA
FTXS-FVMA

Sound level
(HH/H/L)

33/31/29

FXDQ-PB/NBVE: with a drain pump (750 mm lift)
as a standard accessory
FXDQ-PB/NBVET: without a drain pump

(dB(A))
40

50

63

34/32/30

35/33/31

36/34/32


* The values of operation sound level represent those for rear-suction operation.
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
* Values are based on the following conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
panel
harmonises with
of 15 Pa.

750 mm
Ceiling

Stylish flat
your interior décor



Hotline: 0976 173 173

1826


Indoor
Indoor Unit
Unit Lineup
Lineup
VRVIndoor
IndoorUnits
Units
VRV

Ceiling
CeilingMounted
MountedCassette
Cassette(Round
CornerFlow
Typewith Sensing) Type

Slim Ceiling Mounted Duct Type

Airflow block function *3

Sensing function
Auto airflow rate mode + Auto airflow direction mode

Slim design, quietness and
Without sensing function
static pressure switching

FXFQ25S
/ FXFQ32S
/ FXFQ40S
FXKQ25MA
/ FXKQ32MA
FXFQ50S
/ FXFQ63S
/ FXFQ80S
FXKQ40MA
/ FXKQ63MA

Floor temperature is detected and over cooling prevented.


FXFQ100S / FXFQ125S

Area around feet gets
too cold because air
conditioner continues
until the temperature
near the ceiling reaches
the set temperature.

20°C near floor to use in drop-ceilings!
Suited

unit can
be installed
in the minimum space of
Infrared
presence
sensor
195 mm.

The sensor detects human presence and adjusts
the airflow direction automatically to prevent drafts.
Energy saving control can be performed
Min.195 mm
when no people are detected.

Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism realises even

distribution of airflow and room temperature.

Panel spacer

20 mm

26˚C

22˚C

0

20˚C
1

2

3

4

5

Front discharge is possible with an air
discharge
unit airflow
(option),
which air
allows
Indoor

unit offers 360°
discharges
in all the
directions
with more
temperature distribution.
installation
inuniform
the drop-ceiling
or sagging wall.

The sensor detects the floor temperature and automatically
adjusts operation of the indoor unit to reduce the temperature
difference between the ceiling and the floor.

Individual airflow direction control
Thanks to the individual airflow direction control function, airflow
direction can be individually adjusted for each air discharge
outlet. 5 directions of airflow and auto-swing can be selected
with wired remote controller BRC1E62, which realises the
optimum air distribution.
Individual airflow direction example case
Position 2

Swing

Dead spot of airflow
Air discharge grille (Option)

Energy efficiency has been improved thanks to the

adoption of a new heat exchanger with smaller tubes,
DC fan motor and DC drain pump motor.
Set for front discharge using a suspended ceiling.

Low operation
sound level
Main body
FXFQ-S

Sound
level
(H/M/L)

25/32

40

50

63

80

100

125

30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35

Air discharge grille

(Option)

Control of airflow rate can be selected from 3-step
control, which provides comfortable airflow. Auto airflow
rate control can be selected with wired remote controller
BRC1E62.
Downward discharge is shut off and air is blown straight out
(front discharge).

Drain pump is equipped as
A long-life
filter
(maintenance
free up850
tomm
one
standard
accessory
with
850 mm
lift. year*) is equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3



Only 200 mm in height, this model can be installed in
rooms with as little as 240 mm depth between the
drop-ceiling and ceiling slab.

Example: • Cooling setpoint: 26°C

• Shift temperature: 1.0°C
28
27
26

26°C
Occupied

Automatically
reverts when
people return.

240 mm

Control of the airflow rate has been improved from 2-step

Low operation
sound
levelfrom 0.5 to 4°C in 0.5°C increments
Shift temperature
and time can
be selected
(dB(A))
and 15, 30, 45, 60, 90 or 120 minutes respectively with remote controller.
40

50

Suction grille *
* To be obtained locally


The airflow block function is
useful
when rearranging
the
FXDQ-PB
and FXDQ-NB
models are available in two
room
layout.
Airflow
types
to suit different installation
conditions.
mm*5
block

Time

After another 30 min

20/25/32

bolt* all-round
Air filterflow
This function only Suspension
works when
is used. It cannot be used when sealing material is
used inAIRthe air discharge outlet (option).


10 Horizontal
Pa-30 Pa/factory
models.block
flow set: 10 Pa for FXDQ-PBAirflow
15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

26°C

If people
not return,
the air conditioner will raise the
todo
3-step
control.
temperature 1°C every 30 minutes and then operate at 30°C.
FXDQ-PB/NB

200 mm
New airflow block function prevents
900
mm
uncomfortable
drafts
by reducing air velocity.
It can be set using the BRC1E62 remote controller.
* 1,100 mm in width for the FXDQ63NB model.
There is no need for sealing
material of air discharge
outlet (option).


External static pressure selectable by remote controller
switching make this indoor unit a very comfortable and
flexible model.

28°C

Unoccupied

After 30 min

Also can support
such this case

AIR

• Shift time: 30 min.
• Limit cooling temperature: 30°C

27°C

Airflow block
for cabinet side

grille *
Easy Discharge
setup with
remote controller

Sensing sensor low mode *1. 2
When there are no people in a room,

the set temperature is shifted automatically.

Downward discharge

Infrared floor sensor

700 mm

Comfortable airflow
Airflow rate automatically increases during hot or cold periods (when there
is a large difference with set temperature), and operation is rapidly
performed for cooling or heating.When the difference with set temperature
becomes small, drafts are prevented by automatically reducing airflow rate,
and raising the flap to a horizontal position during cooling operation.

Sensing sensor mode

Main body

500 mm

1925

Only

6 (m)

Airflow
block function
prevents uncomfortable

FXDQ40NB
/ FXDQ50NB
/ FXDQ63NB
drafts by reducing air velocity to approx. 0.3m/s.*4

Great for

Energy savings
The temperature near the person is automatically calculated by
detecting the temperature of the floor. Energy is saved, because
200 mm
the area around the feet does not get too cold.

24˚C

1

Single-flow type
air discharge
from corner or from drop-ceiling.

average
temperature of
indoor floor

28˚C
32˚C 30˚C

2


Presence of
people effective
in 4
allows
areas

24°C near floor

The floor temperature, which is lower
hotel
than
nearuse!
the ceiling, is detected.

(m)
3

Drain pump is equipped as standard
accessory with 500 mm lift. Detecting the

Automatic
control using
30°C near ceiling
Only 700 mm in width andthe
23temperature
kg in weight, this
Room temperature is
near the person
calculated as 27°C
in the area

which
model
is
suitable
to
install
in
limited
spaces like
is in the vicinity of the person.
as the room
drop-ceilings in hotels. temperature.

Setpoint (°C)

Slim body needs only 220 mm space above the

Dual sensors detect the presence of people and floor temperature
ceiling.
If youair-conditioning
use a paneland
spacer
(option),
to provide
comfortable
energy
savings.the

With sensing
function

FXDQ20PB
/ FXDQ25PB / FXDQ32PB

Indoor Unit Lineup
Indoor Unit Lineup

Presence of people and floor temperature can be
Slim design for flexible installation
detected to provide comfort and energy savings

Position 3

Airflow block
air velocity
approx. 0.3m/s*4

30°C near ceiling
Room
temperature is
detected as
30°C.

Position 0

Total comfort by individual airflow direction control
and newly-equipped “airflow block function”

63

Sensing sensor

Soundstop
level mode33/31/29
34/32/30
35/33/31
36/34/32
(HH/H/L)
When there are no people in a room, the system
The values of operation sound level represent those for rear-suction operation.
stops *automatically.
*1. 2

FXDQ-PB/NBVE: with a drain pump (750 mm lift)
as a standard accessory
FXDQ-PB/NBVET: without a drain pump

500

Wall

*3. Works in one direction only.

*4. In case of FXFQ63S type (Data is based on Daikin research.)
*5. A gap of 1500 mm is required if the air block function is not used.

750 mm
Ceiling

Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
Absent* stop
can be

selected
1 to 24 hrs in 1 hr
Valuestime
are based
on the
followingfrom
conditions:
increments
with remote
controller.
FXDQ-PB:
external static
pressure of 10 Pa; FXDQ-NB: external static pressure
*1. These of
functions
15 Pa. are not available when using the group control system.
*2. User can set these functions with remote controller.



Hotline: 0976 173 173

2026


Indoor
Indoor Unit
Unit Lineup
Lineup
VRVIndoor

IndoorUnits
Units
VRV
Ceiling
CeilingMounted
MountedCassette
Cassette(Round
CornerFlow)
Type Type

Slim Ceiling
Mounted
Duct
Type Multi Flow) Type
Ceiling
Mounted
Cassette
(Compact
FXZQ20M
/ FXZQ25Mquietness
/ FXZQ32M
Slim
design,
and
FXZQ40M / FXZQ50M
static pressure switching

FXFQ25LU
/ FXFQ32LU
/ FXFQ40LU

FXKQ25MA
/ FXKQ32MA
FXFQ50LU
/ FXFQ63LU
/ FXFQ80LU
FXKQ40MA
/ FXKQ63MA
FXFQ100LU / FXFQ125LU

Suited to use in drop-ceilings!

Quiet, compact, and designed for user comfort

Slim body needs only 220 mm space above the

The industry’s first* Round Flow Ceiling Mounted
ceiling.
you 360°
use aairflow
panelwith
spacer
(option), the
Cassette
type If
offers
improved
unit
can
be
installed

in
the
minimum
space of
temperature distribution.
4-way flow
195 mm.

Round Flow

Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism realises even
distribution of airflow and room temperature.
(m)
3

Min.195 mm
Panel spacer

2

20 mm
There are much fewer
areas of uneven temperature.

There are areas of
uneven temperature.

Single-flow type allows effective air discharge

The light
weight
unitoratfrom
19.5drop-ceiling.
kg for FXFQ25-50LU
from
corner
Drain Drain
pump pump
is equipped
as a
is equipped
as standard
standard
accessory
with
a
850
mm
accessory with 500 mm lift.
lift.

850 mm

A modern sophisticated decoration panel has been
applied, with a panel surface that has been
treated with
500 mm
a dirt-repellant coating.
Treated surface


Untreated surface
Dirt and
grime • Condition after
exposure to the
smoke of 600
3
cigarettes in 1 m
enclosed space.

Resists
soiling

Control of the airflow rate can be selected from 3-step
control.
Low operation sound level
FXFQ-LU

25/32

40

50

(dB(A))
63

80

100


125

Sound
level
30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34
(HH/H/L)

Example of airflow patterns:

All-round flow

All-round flow is available, as well as 2-way to
4-way flows, so you can choose the most
suitable airflow pattern depending on location or
room layout.

28˚C
32˚C 30˚C

26˚C

24˚C

0

2

3


4

5

20/25

Sound Great
level
(H/L)

for 32/29
30/25
hotel use!

32

40

50

32/26
33/29

36/28
36/30

41/33
41/34

Wide discharge angle: 0° to 60°


Auto swing

6 (m)

Front discharge is possible with an air
discharge unit (option), which allows the
installation in the drop-ceiling or sagging wall.

Only

FXDQ40NB / FXDQ50NB / FXDQ63NB

Only 200 mm in height, this model can be installed in
rooms with as little as 240 mm depth between the
drop-ceiling and ceiling slab.

200 mm

700 mm



200 mm

900 mm

* 1,100 mm in width for the FXDQ63NB model.

Suspension bolt*



60°

Main body

240 mm

Discharge grille *
AIR

Downward discharge

An antibacterial treatment that uses silver ions has
been applied to the drain pan, preventing the growth
Air discharge
(Option)
of slime, mould and bacteria
thatgrille
cause
blockages
and odours.
The horizontal louvres prevent dew condensation.
for front dischargesurfaces,
using a suspended
ceiling.
TheirSet
non-flocking
which
repel dirt, are

easy to clean.
Main body
The air filter has an anti-mould and antibacterial
treatment that prevents the growth of mould
generated from dust or moisture that may adhere to
Air discharge grille
the filter.
(Option)
4-way flow

3-way flow

L-shaped 2-way flow

Downward discharge is shut off and air is blown straight out
(front discharge).

A long-life filter (maintenance free up to one
year*) is equipped as standard accessory.




60°

2-, 3-, and 4-way airflow patterns are available,
enabling
in the
of a room.
Control installation

of the airflow
ratecorner
has been
improved from 2-step
to 3-step control.

Low operation sound level

FXDQ-PB and FXDQ-NB models are available in two
750 mm
types to suit different installation
conditions.
FXDQ-PB/NBVE: with a drain pump (750 mm lift)
as a standard accessory
FXDQ-PB/NBVET: without a drain pump

(dB(A))

FXDQ-PB/NB

20/25/32

40

50

63

Sound level
(HH/H/L)


33/31/29

34/32/30

35/33/31

36/34/32

* The values of operation sound level represent those for rear-suction operation.
L-shaped
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
4-way flow
3-way flow
2-way flow
* Values are based on the following conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
*For 3-way
orPa.
2-way flow installation, the sealing member for air discharge outlet
of 15
(option) must be used to close each unused outlet.



* To be obtained locally

15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

*Angles can be also set on site to prevent drafts (0°-35°)

or soiling of the ceiling (25°-60°), other than standard setting (0°-60°).

2

Suction grille *

External static pressure selectable by remote controller
switching make this indoor unit a very comfortable and
Drainflexible
pump model.
is equipped as standard accessory with
Pa-30
750 10
mm
lift. Pa/factory set: 10 Pa for FXDQ-PB models.


60°

Air filter

AIR

60°

Fixed angles: 5 levels

3
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge
sealing

material (option)
used to close each
unused
outlet.
* 8 outlet
hr/day,
25 day/month.
Formust
dustbe
concentration
of 0.15
mg/m

2125

FXZQ-M

1

20˚C
1

Dimensions correspond with 600 mm X 600 mm
architectural module ceiling design specifications.
Only 700 mm in width and 23 kg in weight, this
modelsound
is suitable
Low operation
levelto install in limited spaces like
(230 V)(dB(A))

drop-ceilings in hotels.

Comfortable airflow

22˚C

1

* As of April 2004, the release date for Japan.

models makes installation easy.

FXDQ20PB / FXDQ25PB / FXDQ32PB

Indoor Unit Lineup
Indoor Unit Lineup

360° airflow
improves
distribution
Slim design
for temperature
flexible installation
and offers a comfortable living environment.

750 mm
Ceiling

Hotline: 0976 173 173


2226


Indoor
Indoor Unit
Unit Lineup
Lineup
VRVIndoor
IndoorUnits
Units
VRV
Slim Ceiling
Mounted
Duct
Type Flow) Type
Ceiling
Mounted
Cassette
(Double

4-Way
Flow
CeilingCassette
Suspended
Type
Ceiling
Mounted
Corner
Type


FXCQ20M / FXCQ25M / FXCQ32M

Slim design, quietness and
static
pressure switching
FXCQ80M
/ FXCQ125M

FXKQ25MA / FXKQ32MA
FXUQ71A / FXUQ100A
FXKQ40MA / FXKQ63MA

FXCQ40M / FXCQ50M / FXCQ63M

ceiling.
If you use
a panel spacer (option), the
Unit body
and suction
panel
adopted
round
and in the minimum space of
unit
can shapes
be installed
realised a slim appearance
195 mm.
design. The unit can be used
for various locations such as

the ceilings with no cavity
and mm
Min.195
bare ceilings.

prevention and ceiling soiling prevention, the
auto swing mechanism realises even
distribution of airflow and room temperature.
(m)
3

Panel spacer

Flaps close automatically when
20 mm
the unit stops, which gives a
simpleSingle-flow
appearance.type allows effective air discharge
Unifiedfrom
slim corner
height ofor198
mm
from
drop-ceiling.
for all models that gives the
198 mm
unified impression even when
pump iscapacities
equipped as standard
modelsDrain

with different
accessory
mm lift.
are installed
in thewith
same500
area.
Built-in electronic expansion valve eliminates the need
for a BEV unit, which improves flexibility of installation.
Current model

BEV unit is
needed

New
model
500 mm

2

0

305 mm

20˚C
1

2

3


4

5

Only

Front discharge is possible with an air
discharge unit (option), which allows the
installation in the drop-ceiling or sagging wall.

Control of the airflow rate has been improved from
Main body
2-step to 3-step control. Auto airflow rate control can
be selected with wired remote controller BRC1E62.

Drain pump is equipped as a standard accessory, and the
lift height has been improved from 500 mm to 600 mm.
Set for front
using a suspended
ceiling.
Depending
ondischarge
installation
site requirements
or room
conditions,Main
2-way,
3-way
and

4-way
discharge
body
patterns are available.

3-way flow

4-way flow

Only 200 mm in height, this model can be installed in
rooms with as little as 240 mm depth between the
drop-ceiling and ceiling slab.

200 mm

700 mm

200 mm

900 mm

(When a high-efficiency filter is attached, the unit's height is
400 mm.)

6 (m)

* 1,100 mm in width for the FXDQ63NB model.

Suspension bolt*


Low operation sound level

Air filter

(220 V)(dB(A))

FXCQ-M

20

25/32

40/50

63

80

125

Sound level
(H/L)

32/27

34/28

34/29

37/32


39/34

44/38

240 mm

AIR
Discharge grille *
AIR

Designed with higher airflow suitable for high ceiling
application up to 3 metres.
Providing 2 different settings of standard and ceiling soiling
prevention, the auto swing mechanism realises even
distribution of airflow and room temperature.

Suction grille *
* To be obtained locally

External static pressure selectable by remote controller
switching make this indoor unit a very comfortable and
flexible model.
Two 10
types
optionalset:
high-efficiency
filter
are available
Pa-30ofPa/factory

10 Pa for FXDQ-PB
models.
Pa-44
Pa/factory
set: 15 Pa for
FXDQ-NB models.
(65%15and
95%,
colourimetric
method).

FXDQ-PB and FXDQ-NB models are available in two
types to suit different installation conditions.
A long-life filter (maintenance free up to one year*) is
FXDQ-PB/NBVE: with a drain pump (750 mm lift)
DrainControl
pump is
standard
accessory
with
of equipped
the airflowasrate
has been
improved
from 2-step equipped as standard
accessory.
as a standard
accessory
600 mm
lift.

to 3-step control.
* 8 hr/day,
25 day/month. For dust concentration
of 0.15 mg/m
FXDQ-PB/NBVET:
without a drain
pump
3

Air discharge grille
(Option)

Position 2

Swing

Only 700 mm in width and 23 kg in weight, this
model is suitable to install in limited spaces like
drop-ceilings
hotels.
The thin unit
(only 305 in
mm
high) can be installed in a
ceiling space as narrow as 350 mm. All models feature a
compact design
with a depth of only 600 mm.
Great for
hotel use!


22˚C

Energy efficiency has been improved thanks to the
adoption of a new heat exchanger with smaller
Air discharge
grille
(Option)
tubes, DC fan motor and
DC drain
pump
motor.
BEV unit is
not needed

Thin, lightweight, and easy
to install
in / FXDQ63NB
FXDQ40NB
/ FXDQ50NB
narrow ceiling spaces

FXDQ20PB / FXDQ25PB / FXDQ32PB

24˚C

1

Individual airflow direction example case

Position 3


26˚C

Downward discharge

With adoption of the individual flap control, airflow
direction adjustment can be individually set for each air
outlet. 5 directions of airflow and auto-swing can be
selected with wired remote controller BRC1E62, which
realises the optimum air distribution.
Position 0

28˚C
32˚C 30˚C

Suited to use in drop-ceilings!

Indoor Unit Lineup
Indoor Unit Lineup

This slim and stylish indoor unit achieves
optimum
distribution,
and can
be installed
Slimair
design
for flexible
installation
without the need for ceiling

cavity.
Slim body needs only 220 mm space above the
Providing 3 different settings of standard, draft

Downward
is shut off and air is blown straight out
L-shaped
2-waydischarge
flow
(front discharge).

A long-life filter (maintenance free up to one
year*) is equipped as standard accessory.

Low operation sound level

(dB(A))

FXDQ-PB/NB

20/25/32

40

Sound level
(HH/H/L)

33/31/29

34/32/30


50

63

35/33/31

36/34/32

600 mm

* The values of operation sound level represent those for rear-suction operation.
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
* Values are based on the following conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
of 15 Pa.

Major maintenance work can be performed by removing
750 mm
the panel. A flat-type suction grille and a detachable
blade make cleaning easy.
Ceiling

* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

2325






Hotline: 0976 173 173

2426


Indoor Unit
Unit Lineup
Lineup
Indoor
VRVIndoor
IndoorUnits
Units
VRV
SlimCeiling
CeilingMounted
MountedDuct
DuctType
Type
Slim

CeilingMounted
MountedCassette
CassetteCorner
CornerType
Type
Ceiling

Slimdesign,
design,quietness

quietnessand
and
Slim
staticpressure
pressureswitching
switching
static

FXKQ25MA/ FXKQ32MA
/ FXKQ32MA
FXKQ25MA
FXKQ40MA/ FXKQ63MA
/ FXKQ63MA
FXKQ40MA

Suitedtotouse
useinindrop-ceilings!
drop-ceilings!
Suited

Slim
body
needs
only
220
mm
space
above
the
Slim

body
needs
only
220
mm
space
above
the
ceiling.If you
If you
use
a panel
spacer
(option),
the
ceiling.
use
a panel
spacer
(option),
the
unit
can
installed
the
minimum
space
unit
can
bebe

installed
in in
the
minimum
space
ofof
195
mm.
195
mm.

Providing
3 different
settings
standard,
draft
Providing
3 different
settings
ofof
standard,
draft
prevention
and
ceiling
soiling
prevention,
the
prevention
and

ceiling
soiling
prevention,
the
auto
swing
mechanism
realises
even
auto
swing
mechanism
realises
even
distribution
airflow
and
room
temperature.
distribution
ofof
airflow
and
room
temperature.
(m)(m)
3 3

Min.195
Min.195

mmmm
Panel
spacer
Panel
spacer
20 20
mmmm

Single-flow
type
allows
effective
discharge
Single-flow
type
allows
effective
airair
discharge
from
corner
from
drop-ceiling.
from
corner
oror
from
drop-ceiling.
Drain
pump

equipped
standard
Drain
pump
is is
equipped
asas
standard
accessory
with
500
mm
accessory
with
500
mm
lift.lift.

FXDQ20PB/ FXDQ25PB
/ FXDQ25PB/ FXDQ32PB
/ FXDQ32PB
FXDQ20PB

2 2

28˚C 26˚C
26˚C
28˚C
24˚C
24˚C

30˚C
30˚C
32˚C
32˚C
22˚C
22˚C

1 1

20˚C
20˚C

0 0

Only
700
mm
width
and
weight,
this
Only
700
mm
in in
width
and
2323
kgkg
in in

weight,
this
model
suitable
install
limited
spaces
like
model
is is
suitable
to to
install
in in
limited
spaces
like
drop-ceilings
hotels.
drop-ceilings
in in
hotels.

200
mm
200
mm

200
mm

200
mm

900mm
mm
900

* 1,100
in width
for the
FXDQ63NB
model.
* 1,100
mmmm
in width
for the
FXDQ63NB
model.

Front
discharge
possible
with
Front
discharge
is is
possible
with
anan
airair

discharge
unit
(option),
which
allows
the
discharge
unit
(option),
which
allows
the
installation
the
drop-ceiling
sagging
wall.
installation
in in
the
drop-ceiling
oror
sagging
wall.

Suspension
bolt*
Suspension
bolt*


Air Air
filterfilter

240mm
mm
240

AIRAIR

Main
body
Main
body
500500
mmmm

Only
200
mm
height,
this
model
can
installed
Only
200
mm
in in
height,
this

model
can
bebe
installed
in in
rooms
with
little
240
mm
depth
between
rooms
with
asas
little
asas
240
mm
depth
between
thethe
drop-ceiling
and
ceiling
slab.
drop-ceiling
and
ceiling
slab.


Great
Great
forfor
hotel
use!
hotel
use!

Only
700mm
mm
Only
700

6 (m)
1 1 2 2 3 3 4 4 5 5 6 (m)

FXDQ40NB/ FXDQ50NB
/ FXDQ50NB/ FXDQ63NB
/ FXDQ63NB
FXDQ40NB

Indoor Unit Lineup
Indoor Unit Lineup

Slimdesign
designfor
forflexible
flexibleinstallation

installation
Slim

Discharge
grille
Discharge
grille
* *
AIRAIR

Downward
discharge
Downward
discharge

Suction
grille
Suction
grille
* *
To obtained
be obtained
locally
* To* be
locally

External
static
pressure
selectable

remote
controller
External
static
pressure
selectable
byby
remote
controller
switching
make
this
indoor
unit
a very
comfortable
and
switching
make
this
indoor
unit
a very
comfortable
and
flexible
model.
flexible
model.


discharge
grille
(Option)
Air Air
discharge
grille
(Option)

Pa-30
Pa/factory
FXDQ-PB
models.
10 10
Pa-30
Pa/factory
set:set:
10 10
Pa Pa
for for
FXDQ-PB
models.
Pa-44
Pa/factory
FXDQ-NB
models.
15 15
Pa-44
Pa/factory
set:set:
15 15

Pa Pa
for for
FXDQ-NB
models.

for front
discharge
using
a suspended
ceiling.
SetSet
for front
discharge
using
a suspended
ceiling.

FXDQ-PB
and
FXDQ-NB
models
available
two
FXDQ-PB
and
FXDQ-NB
models
areare
available
in in

two
types
suit
different
installation
conditions.
types
to to
suit
different
installation
conditions.

Main
body
Main
body

Control
airflow
rate
has
been
improved
from
2-step
Control
of of
thethe
airflow

rate
has
been
improved
from
2-step
3-step
control.
to to
3-step
control.

discharge
grille
Air Air
discharge
grille
(Option)
(Option)

Low
operation
sound
level
Low
operation
sound
level
FXDQ-PB/NB
FXDQ-PB/NB

Sound
level
Sound
level
(HH/H/L)
(HH/H/L)

Downward
discharge
is shut
off and
airblown
is blown
straight
Downward
discharge
is shut
off and
air is
straight
out out
(front
discharge).
(front
discharge).

long-life
filter
(maintenance
free

one
AA
long-life
filter
(maintenance
free
upup
toto
one
year*)
year*)
equipped
standard
accessory.
is is
equipped
asas
standard
accessory.

20/25/32
20/25/32

FXDQ-PB/NBVE:
with
a drain
pump
(750
FXDQ-PB/NBVE:
with

a drain
pump
(750
mmmm
lift)lift)
a standard
accessory
as as
a standard
accessory
FXDQ-PB/NBVET:
without
a drain
pump
FXDQ-PB/NBVET:
without
a drain
pump

(dB(A))
(dB(A))
40 40

50 50

63 63

750
mm
750

mm

33/31/29 34/32/30
34/32/30 35/33/31
35/33/31 36/34/32
36/34/32
33/31/29

* The
values
of operation
sound
level
represent
those
for rear-suction
operation.
* The
values
of operation
sound
level
represent
those
for rear-suction
operation.
Sound
level
values
for bottom-suction

operation
be obtained
by adding
5 dB(A).
Sound
level
values
for bottom-suction
operation
cancan
be obtained
by adding
5 dB(A).
* Values
based
on the
following
conditions:
* Values
are are
based
on the
following
conditions:
FXDQ-PB:
external
static
pressure
of Pa;
10 Pa;

FXDQ-NB:
external
static
pressure
FXDQ-PB:
external
static
pressure
of 10
FXDQ-NB:
external
static
pressure
of Pa.
15 Pa.
of 15

Ceiling
Ceiling

3
3
8 hr/day,
25 day/month.
concentration
of 0.15
mg/m
* 8 *hr/day,
25 day/month.
ForFor

dustdust
concentration
of 0.15
mg/m

2525





Hotline: 0976 173 173

2626


Indoor
Indoor Unit
Unit Lineup
Lineup
VRVIndoor
IndoorUnits
Units
VRV
Ceiling
Type Corner Type
CeilingMounted
MountedDuct
Cassette


Ceiling
Suspended
TypeDuct Type
Slim Ceiling
Mounted

FXMQ20P / FXMQ25P / FXMQ32P
FXKQ25MA
/ FXKQ32MA
FXMQ40P
/ FXMQ50P
/ FXMQ63P
FXMQ80P
/ FXMQ100P
/ FXMQ125P
FXKQ40MA
/ FXKQ63MA
FXMQ140P

FXHQ32MA
/ FXHQ63MA
Slim
design,
quietness and
FXHQ100MA
static
pressure switching

Suited toSlim
use inbody

drop-ceilings!
with quiet

Slim body needs only 220 mm space above the

Aceiling.
DC fan motor
the spacer
external(option),
static the
If you increases
use a panel
pressure capacity range to include middle to high
unit can
be installed
in thedesign
minimum
space of
static
pressures,
increasing
flexibility.

mm.Pa for FXMQ20P-32P
30195
Pa–100
30 Pa–160 Pa for FXMQ40P
50 Pa–200 Pa for FXMQ50P-125P
Min.195 mm
50 Pa–140 Pa for FXMQ140P


Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism realises even
distribution of airflow and room temperature.
(m)
3

All models are only 300 mm in height, anPanel spacer
mm of
improvement over the 390 mm 20
height
conventional models. The weight of the
Single-flow
airtodischarge
FXMQ40P
hastype
beenallows
reducedeffective
from 44 kg
28 kg.

frompump
corner
or from drop-ceiling.
Drain
is equipped
as
standard accessory with
700 mm lift.


700 mm

Drain pump is equipped as standard
accessory with 500 mm lift.

Ceiling

Control of the airflow rate has been improved
from 2-step to 3-step control.

Low operation sound level
FXMQ-P 20/25

32

40

50

63

500 mm

80/100

125

(dB(A))
140


Sound
level 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 46/45/43
(HH/H/L)

Energy-efficient
The adopted DC fan motor is much more efficient than
the conventional AC motor, yielding an approximate
20% decrease in energy consumption (FXMQ125P).

FXMQ200MA/FXMQ250MA

FXDQ20PB / FXDQ25PB / FXDQ32PB

2

28˚C
32˚C 30˚C

26˚C

22˚C

2

3

4

5


6 (m)

Front discharge is possible with an air
discharge unit (option), which allows the
Improved
ease of installation
installation
in the drop-ceiling or sagging wall.
Airflow rate can be controlled using a remote controller during
Main body
test operation. With the conventional model, the airflow rate
was controlled from the PC board. It is automatically adjusted to
Downward discharge
the range between approximately
±10% of the rated HH tap
airflow for FXMQ20P–125P.

Built-in Drain Pump (Option)

Housing the drain pump inside the unit reduces the
space required for installation.Air discharge grille
(Option)

With drain pump
mm

External static pressure can be easily adjusted using
a change-over switch inside the electrical box to meet
the resistance in the duct system.


2725

Only

Downward
discharge is shut off and air is blown
out
470 straight
mm
470
mm
(front discharge).

222 mm

25 mm

A long-life filter (maintenance free up to one
Indoor unit
year*) is equipped as standard accessory.

Indoor unit

200 mm

700 mm

200 mm


900 mm

* 1,100 mm in width for the FXDQ63NB model.

Low operation sound level

(dB(A))

FXHQ-MA

32

63

100

Sound level
(H/L)

36/31

39/34

45/37

Suspension bolt*

Air filter

240 mm


AIR
Discharge grille *

Installation is easy
Drain pump kit (option) can be easily incorporated.

AIR

Suction grille *

* To be obtained locally
Maintenance is easy
Non-dew Flap with no implanted bristles

Bristle-free
minimises
ExternalFlap
static
pressure selectable by remote controller
contamination
and makes
switching make
this indoor unit a very comfortable and
cleaning simpler.

600 mm

flexible model.


10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.
15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

Drain pump kit
(built inside main unit)

Main body

0–250

Simplified Static Pressure Control

Quiet stream fan

Straightening vane

Air discharge grille (Option)
Improved ease of maintenance
The drain pan can be detached for easy cleaning. An
antibacterial treatment that uses silver ions has been applied to
the drain
preventing
thea growth
ofceiling.
slime, mould and
Setpan,
for front
discharge using
suspended
bacteria that cause blockages and odours.


Without drain pump

Sound absorption
member

Only 200 mm in height, this model can be installed in
rooms with as little as 240 mm depth between the
drop-ceiling and ceiling slab.

Great for
hotel use!

Turbulent flow
is produced

20˚C
1

700 mm
in width
Uses the Only
quiet stream
fan and
many and 23 kg in weight, this
more advanced
modeltechnologies.
is suitable to install in limited spaces like

24˚C


1
0

FXDQ40NB / FXDQ50NB / FXDQ63NB

Adoption of QUIET STREAM FAN

drop-ceilings in hotels.

and wide airflow

Indoor Unit Lineup
Indoor Unit Lineup

Middle and high static pressure
Slim
design
flexible
allows
for for
flexible
ductinstallation
design

Wide air discharge openings produce a spreading 100°
Control of the airflow rate has been improved from 2-step
airflow.
to 3-step control.
Low operation sound level


(dB(A))

FXDQ-PB/NB

20/25/32

40

50

63

Sound level
(HH/H/L)

33/31/29
100°

34/32/30

35/33/31

36/34/32

* The values of operation sound level represent those for rear-suction operation.
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
* Values are based on the following conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
of 15 Pa.


FXDQ-PB and FXDQ-NB models are available in two
types to suit different installation conditions.

Non-dew
FXDQ-PB/NBVE:
with aFlap
drain pump (750 mm lift)
as a standard accessory
Easy-to-clean
flat
design
FXDQ-PB/NBVET: without a drain pump

Maintenance is easier because everything can be
performed from below the unit.

750 mm
A long-life filter (maintenance
free up to one year*) is
equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
Ceiling

* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3






Hotline: 0976 173 173

2826


Indoor
Indoor Unit
Unit Lineup
Lineup
VRVIndoor
IndoorUnits
Units
VRV
Wall
Mounted
TypeCassette Corner Type
Ceiling
Mounted

Floor
Type
SlimStanding
Ceiling Mounted
Duct Type
FXLQ20MA / FXLQ25MA
Slim
design, quietness and
FXLQ32MA / FXLQ40MA
static
pressure

switching
FXLQ50MA
/ FXLQ63MA

FXAQ20P / FXAQ25P
FXKQ25MA
/ FXKQ32MA
FXAQ32P
/
FXAQ40P
FXKQ40MA / FXKQ63MA
FXAQ50P / FXAQ63P

Stylish flat panel design harmonised
Slim design
for flexible
installation
with your
interior décor
unit can be installed in the minimum space of

Flat
panel
can be cleaned with only the single pass of a
195
mm.
cloth across their smooth surface.
Flat panel can also be easily removed and washed for
more thorough cleaning.
Min.195 mm


Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism realises even
distribution of airflow and room temperature.
(m)
3

Panel spacer

Low operation sound level
FXAQ-P

20

25

20 mm
32

40

28˚C
32˚C 30˚C

2

(dB(A))

50


26˚C

24˚C

63

Single-flow type allows effective air discharge
38/31
39/34
42/37
47/41
drop-ceiling.

0

20˚C
1

2

3

4

5

Only

Main body


5 steps of discharge angle can be set by remote
controller.
Discharge angle is automatically set at the same angle
as the previous operation when restarting. (Initial setting:
10° for cooling and 70° for heating)
Flexible installation
Drain pipe can be fitted to from either left or
right sides.

The adoption of a fibre-less discharge grille featuring an
forto prevent condensation also helps
originalGreat
design
hotel use!
prevent staining and makes cleaning easier.

6 (m)

Front discharge is possible with an air
discharge unit (option), which allows the
installation in the drop-ceiling or sagging wall.

Vertical auto-swing realises efficiency of air distribution.
The louvre closes automatically when 500
themm
unit stops.

Floor Standing types can be hung on the wall for easier
cleaning.

Running
the
from23
thekgback
allowsthis
the
Only
700 mm
in piping
width and
in weight,
unit to model
be hung
on
walls.
Cleaning
under
the
unit,
where
is suitable to install in limited spaces like
dust tends
to accumulate,
is considerably easier.
drop-ceilings
in hotels.

Only 200 mm in height, this model can be installed in
rooms with as little as 240 mm depth between the
drop-ceiling and ceiling slab.


700 mm

900Wallmm
hanging

3

Floor installation

Suspension bolt*

Concealed Floor Standing Type

Air filter

240 mm

AIR
Discharge grille *
AIR

FXNQ32MA / FXNQ40MA
FXNQ50MA / FXNQ63MA

Suction grille *
* To be obtained locally

External static pressure selectable by remote controller
switching make this indoor unit a very comfortable and

flexible model.

Air discharge grille (Option)

Drain pump kit is available as optional accessory, which
lifts the drain 1,000 mm from the bottom of the unit.
Setoffordrain-up
front discharge using a suspended ceiling.
Height

200 mm

* 1,100 mm in width for the FXDQ63NB model.

FXNQ20MA / FXNQ25MA
Downward discharge

10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.
15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

FXDQ-PB and FXDQ-NB models are available in two
Designed to be concealed in the
skirting-wall
typesperimeter
to suit different installation
conditions.

Main body

Control

the airflowinrate
has beenof
improved
from
2-step
The
unit isofconcealed
skirting-wall
perimeter,
that
to 3-step
enables
to control.
create high class interior design.

1,000 mm

Drain pump kit

FXDQ40NB / FXDQ50NB / FXDQ63NB

A long-life filter (maintenance free up to one year*) is
equipped as standard accessory.
200 mm
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m

22˚C

1


Sound level
35/31
36/31
from
(H/L) corner or from

Drain
equipped
as standard
Drain
panpump
and airisfilter
can be kept
clean by mould-proof
polystyrene.
accessory with 500 mm lift.

Suitable for perimeter zone air conditioning

FXDQ20PB / FXDQ25PB / FXDQ32PB

Indoor Unit Lineup
Indoor Unit Lineup

Stylish
panel
design
creates
graceful
harmony

Slimflat
body
needs
only
220 amm
space
above that
the
enhances
any
interior
space.
ceiling. If you use a panel spacer (option), the

Suited to use in drop-ceilings!

Air discharge grille
(Option)
Indoor
unit

Low
operation port
sound
level
The
connecting
faces
downward,
greatly

facilitating on-site
FXDQ-PB/NB
20/25/32piping work.
40
Sound level
(HH/H/L)

Downward discharge is shut off and air is blown straight out
(front discharge).

A long-life filter (maintenance free up to one
year*) is equipped as standard accessory.

33/31/29

34/32/30

FXDQ-PB/NBVE: with a drain pump (750 mm lift)
as a standard accessory
FXDQ-PB/NBVET: without a drain pump

(dB(A))
50
35/33/31

63

Connecting
port
36/34/32


A long-life filter (maintenance free up
Refrigerant
The values of operation sound level represent those for rear-suction operation. piping
to* one
year*) is equipped as standard
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
* Values are based on the following conditions:
accessory.

750 mm
Ceiling

* Appliesstatic
also topressure
Floor Standing type (FXLQ-MA).
FXDQ-PB:
external
pressure of of
100.15
Pa;mg/m
FXDQ-NB:
external
3
* 8 hr/day,
25 day/month.
Forstatic
dust concentration

of 15 Pa.


* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

2925





Hotline: 0976 173 173

3026


Indoor
Indoor Unit
Unit Lineup
Lineup
VRVIndoor
IndoorUnits
Units
VRV

Residential Indoor Units

Floor
Standing
Duct
Type Corner Type
Ceiling

Mounted
Cassette

Slim Ceiling
Mounted
Duct
Type
Ceiling
Mounted
Cassette
Type

FXVQ125M / FXVQ200M
FXKQ25MA
/ FXKQ32MA
FXVQ250M
/ FXVQ400M

/ FCQ50B
SlimFCQ35B
design,
quietness and
FCQ60B / FCQ71B
static pressure switching

FXKQ40MA / FXKQ63MA
FXVQ500M

Large airflow type for large spaces.
Flexible interior design for each tenant.

Slim design for flexible installation

Suited to use in drop-ceilings!
FXDQ20PB / FXDQ25PB / FXDQ32PB

Slim body needs only 220 mm space above the
Various installations
be supported
from full-scale
ceiling.
If you use acan
panel
spacer (option),
the duct
connection airflow to direct airflow that allows for easy
unit
can
be
installed
in
the
minimum
space
of
installation.
195 mm.
Full-scale duct connection airflow
allows for air conditioning evenly in
spacious areas. Min.195 mm


Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism realises even
distribution of airflow and room temperature.
(m)
3

Panel spacer
Duct connection airflow type
20 mm

26˚C

1

2

3

4

5

6 (m)

Downward discharge

A long-life filter (maintenance free up to one year*) is
equipped as a standard accessory.


Air discharge grille (Option)

950 mm

Main body

A wide range of optional accessories are available such
as high-efficiency filters.
All-fresh (using outdoor air only) system
Outside

*When using the unit as an outdoor-air
processing unit, there are some
restrictions. Strictly follow the restrictions
specified in the Engineering Data Book.

Outdoor air
introduction

Air
conditioning

Outside

Suspension bolt*

Same for
all models

240 mm


Discharge grille
Draft* prevention
AIR

A long-life filter (maintenance free up to one
introduced from the outside and circulated air must be mixed in the
year*) is*airAir
equipped
as standard accessory.
conditioner primary side before introduction into the air conditioner.

Low operation
level
FXDQ-PB/NBsound
20/25/32

Suction grille *
* To be obtained locally

External static pressure selectable by remote controller
switchingSoiling
makeprevention
this indoor unit a very comfortable and
flexible model.

Decoration panel is optional

Low operation sound level


Air
conditioning

Downward discharge is shut off and air is blown straight out
(front discharge).
Outdoor air
introduction

Air filter

10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.
15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.

FXDQ-PB and FXDQ-NB models are available in two
types to suit different installation conditions.

DrainFXDQ-PB/NBVE:
pump is equipped
as
with a drain pump (750 mm lift)

Min. been
245 mm improved from 2-step
Control of the airflow rate has
a standard accessory
standard with 750asmm.
to 3-step control.
FXDQ-PB/NBVET: without a drain pump

Air discharge grille

(Option)
Return + Outdoor air mixed system
Circulated air

Outdoor air intake mode is
useable as an outdoor-air
processing air conditioner.

Standard

The indoor units weigh only 24 kg and require an
installation space with a height of just 245 mm.

Set for front discharge using a suspended ceiling.

mg/m3

* 1,100 mm in width for the FXDQ63NB model.

AIR

Main body

Design with high maintainability that allows major
services and maintenance services to be performed at
the front.

200 mm

Three convenient patterns for auto-swing operation


All models feature a decoration panel with the same
compact size and simple design for easier planning
of lighting systems and harmonising of interior décor.

950 mm

The high static pressure type driven by the belt drive
system allows for use of air discharge outlets in various
shapes as well as long ducts. Highly
installation
500 flexible
mm
is possible.

Note: Wireless remote
controllers and signal
receiver units are sold
as a set.

Specially designed for false ceilings
200 mm
900 mm finish
—for
a
smooth,
modern interior
Only 700 mm

20˚C


0

Only 200 mm in height, this model can be installed in
Signal receiver
unit the
depth
between

Option
rooms with as little as 240 mm
Note: Remote controller
drop-ceiling
cables
not included. and ceiling
Optionslab.
Cables should be
obtained locally.

Great for
hotel use!

22˚C

Front discharge is possible with an air
discharge unit (option), which allows the
installation in the drop-ceiling or sagging wall.

Drain pump is equipped as standard
Direct airflow type

accessory with 500 mm lift.

Only 700 mm in width and 23 kg in weight, this
model is suitable to install in limited spaces like
drop-ceilings in hotels.

24˚C

1

Adding the plenum
chamber
(option)air discharge
Single-flow
type allows
effective
allows for simple operation with direct
from
corner or from drop-ceiling.
airflow.

* Note that the operation sound increases by
approximately 5 dB(A).

28˚C
32˚C 30˚C

2

FXDQ40NB / FXDQ50NB / FXDQ63NB


Indoor Unit Lineup
Indoor Unit Lineup

Large airflow type that fits for spacious areas such as factories
and large stores.

* 8 hr/day, 26 day/month. For dust concentration of 0.15

with connection to BP units

750 mm

(dB(A))

These models have750
themm
35/33/31
36/34/32 power to provide a
FCQ71B
comfortable airflow
Ceiling
values of operation sound level represent those for rear-suction operation.
33/29 dB (A) 35/30 dB (A) 35/30 dB (A)
33/29* The
dB
(A)
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).even with a ceiling
* Values are based on the following conditions:
height of up to 3.8 m.

FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
40

Sound level
34/32/30
FCQ35B(HH/H/L)FCQ50B33/31/29FCQ60B

50

(H/L)

63

Max. 3.8 m

of 15 Pa.

* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

3125





Hotline: 0976 173 173

3226



Indoor
Indoor Unit
Unit Lineup
VRV IndoorIndoor
Units Units
Residential

with connection to BP units
Ceiling
Mounted
Built-inDuct
TypeType
Slim Ceiling
Mounted

CeilingMounted
MountedCassette
Cassette(Compact
Corner Type
Ceiling
Multi Flow) Type

Slim FBQ60B
design,
quietness and
/ FBQ71B
static pressure switching

FFQ25B / FFQ35B
FXKQ25MA

/ FXKQ32MA
FFQ50B
/
FFQ60B
FXKQ40MA / FXKQ63MA

Option

Suited to use in drop-ceilings!

Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism realises even
Option
Signal receiver unit
distribution of airflow
and room
temperature.
Note: Remote controller
Note: Wireless remote
Option
cables not included.
Cables should be
obtained locally. (m)

3

Min.195 mm

FXDQ20PB / FXDQ25PB / FXDQ32PB


Panel spacer

2

controllers and signal
receiver units are sold
as a set.

28˚C
32˚C 30˚C

26˚C

24˚C

Quiet, compact, and designed for user comfort
20 mm

Single-flow type allows effective air discharge
Designed to fit 600 mm wide ceiling grids
from corner or from drop-ceiling.
575 mm

575 mm

Drain pump is equipped as standard
accessory
with 500 mm lift.
286

mm

act
Comp e panel
tiv
decora

Comfortable across all areas

5 direction

T-bar grid does not need to be cut.

Air discharge grille (Option)

0
60

Auto-swing
between 0 and 60

0

60

Draft
Set for front discharge using a suspended ceiling.
prevention
0
0

setting
Auto-swing
Main
35
35 body
(Set on site)
between 0 and 35

Ceiling panel

T-bar

Setting to
prevent
soiling of
ceiling

600 mm

600 mm

Low operation sound level

(Set on site)

25
60

Auto-swing
between 25 and 60


25
60

FFQ25B

FFQ35B

FFQ50B

FFQ60B

29.5/24.5 dB (A)

32/25 dB (A)

36/27 dB (A)

41/32 dB (A)

Settable to 5 different levels
between 25 and 60

Drain pump is equipped as standard
accessory with 750 mm lift.
Downward discharge is shut off and air is blown straight out
(front discharge).

A long-life filter (maintenance free
up mm

to one
750
year*) is equipped as standard accessory.



In crawl space
6

Only

200 mm

700 mm

2 Air conditioner

4

350 mm or more

With canvas bellows and air intake panel (sold separately)
4

6

Air intake

Long-life filter


Long-life filter
5

13

2 Air conditioner

Air intake

Long-life filter

2 Air conditioner

450 mm or more

6

8

Air blow

4

9

540 mm or more
Air intake

Air filter


Air intake

8

5

Air blow

Options 1 Decorative panel

4

Air discharge opening adaptor
Canvas bellows and air intake panel

5
6

Flexible duct
Air discharge grille
Air discharge chamber

7

1

240 mm

With ordinary ducts
Ordinary duct

(procured locally)

11
11
Discharge
grille *

7

540 mm or more

7
3

Suspension
bolt*
5

Ceiling return with high-efficiency filter
AIR

5

2

4

Air blow

Ceiling return

4

* 1,100 mm
in width for the FXDQ63NB model.
2 Air conditioner
6

1

Air intake

Air blow

45 mm

With high-efficiency filter

425 mm or more

3

200 mm

900 mm

2 Air conditioner

1

5


Air blow

3

Settable to 5 different levels
between 0 and 35

* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

3325

Flexible air discharge unit to
fit various forms of space

10

High-efficiency filter

460 mm or more

9

AIR

Air blow

10

Ordinary duct

(procured locally)

Air conditioner

Suction grille *
8

intake
* ToAirbe
obtained locally

Air discharge opening flange

11 Rear intake filter chamber
Inspection panel
External
static pressure selectable
by remote controller
12 Branch duct
9 Rear intake blocking pad
switching make this indoor
unit a very comfortable and
13 Low-draft filter chamber
flexible model.
8

Settable to 5 different levels
between 0 and 60

Air discharge grille

(Option)
Note: Angles shown above are provided as a guide. They
may differ depending on the installation site.

(H/L)

Only 200 mm in height, this model can be installed in
rooms with as little as 240 mm depth between the
drop-ceiling and ceiling slab.

The indoor unit can be installed in rooms with as little as 350 mm between the drop ceiling and ceiling slab.
It also works with both flexible and ordinary ducts.

6

Conditioned air is distributed
Adjustable airflow angle to
evenly by Auto-swing operation.
suitdischarge
all room conditions.
Downward

Standard
setting

Great for
hotel use!

Standard installation examples


Main body

AUTO-SWING

700 mm

Only 700 mm in width and 23 kg in weight, this
model is suitable to install in limited spaces like
drop-ceilings in hotels.

20˚C

Low draft performance
is2 3 4 5 6 (m)
0
1

designed for your comfort.
0º Horizontal Flow
Front discharge is possible with an air
discharge unit (option), which
allows the
Less draught
installation in the drop-ceiling or sagging wall.

500 mm

700 mm

22˚C


1

FXDQ40NB / FXDQ50NB / FXDQ63NB

Indoor Unit Lineup

Slim design for flexible installation
Slim body needs only 220 mm space above the
ceiling. If you use a panel spacer (option), the
unit can be installed in the minimum space of
195 mm.

Note: Remote controller
cables not included.
Cables should be
obtained locally.

10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.

Pa-44 Pa/factory
set: 15 Pa
FXDQ-NB models.
To cope with the challenges of L-shaped or
Drain15pump
is equipped
asforstandard
accessory with
U-shaped spaces, it is possible to install the air
250 mm lift.

FXDQ-PB and FXDQ-NB models are available in two
discharge unit away from the main unit. This
types to suit different installation conditions.
extends the possibilities for coping with human
FXDQ-PB/NBVE: with a drain pump (750 mm lift)
Control patterns
of the airflow
rate lighting.
has beenAt
improved
from 2-step
gathering
or sun
the same
as a standard accessory
250 mm
to different
3-step control.
FXDQ-PB/NBVET: without a drain pump
time,
types of architectural space can be
keptLow
comfortable.
operation sound level
(dB(A))

FXDQ-PB/NB

20/25/32


40

50

63

Sound level
(HH/H/L)

33/31/29

34/32/30

35/33/31

36/34/32

750 mm

Low operation sound level
Ceiling

* The values of operation sound level represent those for rear-suction operation.
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
* Values are based on the following conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
of 15 Pa.room
L-shaped
U-shaped room
Long room




(H/L)

FBQ60B

FBQ71B

41/35 dB (A)

41/35 dB (A)

Hotline: 0976 173 173

3426


Indoor Unit
Unit
Lineup
Indoor
Outdoor
UnitLineup
Lineup
Outdoor
Units
withconnection
connectiontotoBPBPunits
units

Residential
IndoorUnits
Unitswith
Residential
Indoor

Cooling Only / Heat Pump
Lineup
WallMounted
MountedType
Type
Wall

VRV IV outdoor unit offers a higher capacity of up to 60 HP, responding to the needs of large-sized building.
The singleCooling
outdoor
unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing the
Cooling
Only
Only
FDKS25EA
/ FDKS35EA
FDKS25EA
/ FDKS35EA
system flexibility to a new level.
FDKS25CA
/ FDKS35CA
FDKS25CA
/
FDKS35CA

With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.
FDKS50C
/
FDKS60C
FDKS50C
/
FDKS60C
Outdoor units with anti-corrosion specifications (-E type on request) are designed specifically for use in areas which are subject to
Heat
Pump CDXS25EA
Heat
Pump
CDXS25EA
/ CDXS35EA
/ CDXS35EA
salt damage and atmospheric
pollution.

FDXS25C
/ FDXS35C
FDXS25C
/ FDXS35C
FDXS50C
/ FDXS60C
FDXS50C
/ FDXS60C

Double Outdoor Units
12, 14, 16 HP


Triple Outdoor Units

18, 20, 22, 24, 26, 28, 30, 32 HP

HP
Cooling
OnlyOnlyFTKS25D
FTKS25D/ FTKS35D
/ FTKS35D
High-COPCooling
Type
HeatHeat
Pump
PumpFTXS20D
FTXS20D
/ FTXS25E/ FTXS35E
/ FTXS35E
/ FTXS25E
Standard Type
Space Saving Type

Standard
accessory*
Standard
accessory*

Cooling
Cooling
OnlyOnlyFTKS50B
FTKS50B


Cooling
Cooling
OnlyOnlyFTKS50F
FTKS50F/ FTKS60F
/ FTKS60F/ FTKS71F
/ FTKS71F
HeatHeat
Pump
PumpFTXS50F
FTXS50F/ FTXS60F
/ FTXS60F/ FTXS71F
/ FTXS71F

34, 38 HP

Standard
accessory
Standard
accessory

New Lineup

36, 40 HP

42, 44, 46, 48, 50 HP

Standard
accessory*
Standard

accessory*

Note:
Remote
controllers
Note:
Remote
controllers
other
standard
other
thanthan
the the
standard
accessory
wireless
remote
accessory
wireless
remote
controller
cannot
be used.
controller
cannot
be used.

Slimand
andsmooth
smoothdesign

design
Slim
RX(Y)Q26THY1(E)
suitsyour
yourshallow
shallow
ceiling
suits
ceiling
RX(Y)Q34THY1(E)
RX(Y)Q28THY1(E)

RX(Y)Q18THY1(E)
RX(Y)Q20THY1(E)
RX(Y)Q38THY1(E)
RX(Y)Q22THY1(E) RX(Y)Q30THY1(E)
RX(Y)Q32THY1(E)
RX(Y)Q24THY1(E)
Models
the
FDKS-EA
and
CDXS-EA
series
are
Models
in in
the
FDKS-EA
and

CDXS-EA
series
are
Low
operation
sound
level
Low
operation
sound
level
RX(Y)Q12THY1(E)
RX(Y)Q14THY1(E)
RX(Y)Q16THY1(E)

Standard
Standard
accessory*
accessory*

RX(Y)Q36THY1(E)
RX(Y)Q40THY1(E)

(H/L/SL)
(H/L/SL)

only
700
mm
width

and
weight,
are
only
700
mm
in in
width
and
2121
kgkg
in in
weight,
soso
are
FDKS25 FDKS35
FDKS35 FDKS50
FDKS50 FDKS60
FDKS60
FDKS25
easily
installed
in
limited
spaces.
Just
200
mm
in
easily

installed
in
limited
spaces.
Just
200
mm
in
Standard Type
C(F)DXS25 C(F)DXS35
C(F)DXS35 FDXS50
C(F)DXS25
FDXS60
FDXS50 FDXS60
height,
models
can
installed
in
rooms
with
height,
allall
models
can
bebe
installed
in
rooms
with

Double
Outdoor
Units
Single
Outdoor
Units
35/31/29
35/31/29
dBdB
(A)(A)35/31/29
35/31/29
dBdB
(A)(A)37/33/31
38/34/32
37/33/31
dBdB
(A)(A)
dBdB
(A)(A)38/34/32
as
little
as
240
mm
depth
between
the
drop
as
little

as
240
mm
depth
between
the
drop
6, 8, 10, 12 HP
14, 16 HP
22, 24, 26 HP
18, 20 HP
28, 30, 32 HP
ceiling
and
ceiling
slab,
making
them
ideal
ceiling
and
ceiling
slab,
making
them
ideal
forfor
Home
Leave
Operation

prevents
large
rises
falls
Home
Leave
Operation
prevents
large
rises
or or
falls
in in
even
shallow
ceilings. FDKS-EA
even
shallow
ceilings.
FDKS-EA
indoor
temperature
continuing
operation*
while
thethe
indoor
temperature
byby
continuing

operation*
while
CDXS-EA
CDXS-EA
Great
Great
forfor
you
sleeping
your
home.
This
means
that
you
areare
sleeping
or or
outout
of of
your
home.
This
means
that
hotel
use!
hotel
use!
air-conditioned

welcome
awaits
when
you
wake
anan
air-conditioned
welcome
awaits
when
you
wake
or or
return.
It also
means
that
indoor
temperature
can
return.
It also
means
that
thethe
indoor
temperature
can
quickly
return

your
favourite
comfort
setting.
quickly
return
to to
your
favourite
comfort
setting.
RX(Y)Q6TY1(E)
RX(Y)Q8TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q12TY1(E)

200
mm
200
mm
RX(Y)Q18TNY1(E)
RX(Y)Q20TNY1(E)

RX(Y)Q14TY1(E)
RX(Y)Q16TY1(E)
Only
700
mm
Only
700

mm

RX(Y)Q22TNY1(E)
* Home
Leave
Operation
selected
any
temperature
from
* Home
Leave
Operation
cancan
be be
selected
for for
any
temperature
from
18 18
to to
RX(Y)Q28TNY1(E)
32˚C
for
cooling
operation
to 30˚C
heating
operation.

32˚C
forRX(Y)Q24TNY1(E)
cooling
operation
andand
10 10
to 30˚C
for for
heating
operation.
RX(Y)Q30TNY1(E)
* Home
Leave
Operation
function
must
using
remote
controller
* Home
Leave
Operation
function
must
be be
setset
using
thethe
remote
controller

RX(Y)Q26TNY1(E)
RX(Y)Q32TNY1(E)
when
going
to sleep
or leaving
house,
after
waking
or returning
when
going
to sleep
or leaving
thethe
house,
andand
after
waking
up up
or returning
home.
home.

FDKS25EAFDKS35EA
FDKS35EAFDKS25CA
FDKS25EA
FDKS35CA
FDKS25CAFDKS35CA
CDXS25EACDXS35EA

CDXS35EAFDXS25C
CDXS25EA
FDXS35C
FDXS25C FDXS35C
Suspension
Suction
duct*
Suspension
bolt*bolt*Suction
duct*
Air discharge
duct*
Air discharge
duct*
x 900
x 620
x 900
x 620
mmmm
Dimensions
x 700
x 620
Dimensions
(H x(HWx xWD)x D) 200200
x 700
x 620
mmmm 200200
Air filter
Air filter
Space

Saving Type 21 21
Air discharge
grille*
Air discharge
grille*
25 25
kg kg
Weight
Weight
kg kg
3/min
Airflow
m3/min
Airflow
raterate
(H) (H)
8.78.7
m3/min
Single
Outdoor
Units
m3/min10 10
m3/min
9.59.5
m3/min
mOutdoor
Double
Units
AIR
AIR

30 30
Pa Pa
40 40
Pa Pa
External
static
pressure
External
static
pressure

18, 20 HP

22, 24 HP

240
mm
240
mm

RX(Y)Q22TSY1(E)
RX(Y)Q24TSY1(E)

Signals
from
wireless
remote
controller
Signals
from

thethe
wireless
remote
controller
areare
transmitted
to the
signal
receiver.
transmitted
to the
signal
receiver.

133535

Air suction
Air suction
grille*
grille*

Notes:
Notes:
1. prevent
To prevent
an increase
in operation
noise,
avoid
1. To

an increase
in operation
noise,
avoid
Option
Option
installing
air suction
grille
directly
below
installing
the the
air suction
grille
directly
below
the the
suction
chamber.
suction
chamber.
2. Grilles,
piping
connections,
ducts,
installation
2. Grilles,
piping
connections,

ducts,
andand
installation
parts
should
be obtained
locally.
Ceiling
parts
should
be obtained
locally.
SlimSlim
Ceiling
Mounted
Duct
models
do not
have
drain-up
Mounted
Duct
typetype
models
do not
have
drain-up
RX(Y)Q26TSY1(E)
RX(Y)Q30TSY1(E)
Suction

grille
(KDGF19A45)
Suction
grille
(KDGF19A45)
pumps.
pumps.
RX(Y)Q28TSY1(E)
RX(Y)Q32TSY1(E)
3. The
signal
receiver
must
be located
3. The
signal
receiver
unitunit
must
be located
nearnear
the the
air suction
inlet,
because
includes
air suction
inlet,
because
the the

unitunit
includes
a a
sensor
detects
room
temperature.
sensor
thatthat
detects
room
temperature.



Titanium
apatite
a photocatalytic
material
with
Titanium
apatite
is is
a photocatalytic
material
with
high
adsorption
power.
Titanium

apatite
also
high
adsorption
power.
Titanium
apatite
also
effectively
adsorbs
and
bacteria
adsorbs
decomposes
(H/L/SL)
(H/L/SL)
42,
44 HP effectively
46,and
48,
50,decomposes
52, 54, 56,bacteria
58,
60 HP
38, 40 HP
34, 36 HP
across
its
entire
surface.

The
photocatalyst
across
its
entire
surface.
The
photocatalyst
is is
FTK(X)S35FTK(X)S50
FTK(X)S50FTK(X)S60
FTK(X)S60FTK(X)S71
FTK(X)S71
FTK(X)S20/25FTK(X)S35
FTK(X)S20/25
activated
simply
exposure
light.
activated
simply
byby
exposure
to to
light.
39/26/23
43/34/31
45/36/33
46/37/34
37/25/22

39/26/23
dB dB
(A) (A)43/34/31
dB dB
(A) (A)45/36/33
dB dB
(A) (A)
46/37/34
dB dB
(A) (A)
37/25/22
dB dB
(A)(A)
Wall
Mounted
indoor
units
achieve
quiet
sound
Wall
Mounted
indoor
units
achieve
quiet
sound

Triplelevels
Outdoor

Units
levels
during
cooling
operation.
of of
2222
dBdB
(A)(A)
during
cooling
operation.

Intelligent
Eye
with
infrared
sensor
Intelligent
Eye
with
itsits
infrared
sensor
automatically
controls
conditioner
operation
automatically
controls

airair
conditioner
operation
according
human
movement
a room.
When
according
to to
human
movement
in in
a room.
When
there
movement,
it adjusts
the
temperature
there
is is
nono
movement,
it adjusts
the
temperature
2˚C
energy
savings.

byby
2˚C
forfor
energy
savings.
RX(Y)Q42TNY1(E)
RX(Y)Q38TNY1(E)
RX(Y)Q34TNY1(E)
RX(Y)Q36TNY1(E)

RX(Y)Q46TNY1(E)
RX(Y)Q48TNY1(E)
RX(Y)Q50TNY1(E)
RX(Y)Q52TNY1(E)
Titanium
Apatite
Titanium
Apatite

RX(Y)Q44TNY1(E)

RX(Y)Q40TNY1(E)

filter
AirAir
filter
Catches
dust
Catches
dust


RX(Y)Q54TNY1(E)
RX(Y)Q56TNY1(E)
RX(Y)Q58TNY1(E)
RX(Y)Q60TNY1(E)

Photocatalytic
Photocatalytic
Air-purifying
Filter
Air-purifying
Filter

34, 36, 38, 40 HP
3-D
Airflow
3-D
Airflow
combines
Vertical
combines
Vertical
and
Horizontal
and
Horizontal
Auto-Swing
Auto-Swing
to to
circulate

every
circulate
airair
to to
every
part
a room
part
of of
a room
forfor
uniform
cooling
even
uniform
cooling
of of
even
large
spaces.
large
spaces.
RX(Y)Q34TSY1(E) RX(Y)Q38TSY1(E)
When
in the
room
When
youyou
areare
in the

room

* Locally
obtained
parts
obtained
parts
AIR * Locally
AIR

RX(Y)Q18TY1(E)
RX(Y)Q20TY1(E)

Stylishflat
flatpanel
panelharmonises
harmoniseswith
withyour
yourinterior
interiordécor
décor
Stylish

Double Outdoor Units

26, 28, 30, 32 HP

Chamber
Chamber
Signal

receiver
Signal
receiver
wirewire
=
=
Length1,900
1,900
Length
mmmm Signal
Signal
receiver
receiver

RX(Y)Q42THY1(E)
RX(Y)Q48THY1(E)
* Remote
controllers
other
standard
accessory
wireless
remote
controller
cannot
be used.
* Remote
controllers
other
thanthan

the the
standard
accessory
wireless
remote
controller
cannot
be used.
RX(Y)Q44THY1(E) RX(Y)Q50THY1(E)
RX(Y)Q46THY1(E)

Indoor Unit Lineup
Indoor Unit Lineup

High-COP Type

Mo/C

Outdoor Unit Lineup

Slim
Ceiling
Mounted
Duct
Type
Slim
Ceiling
Mounted
Duct
Type

The
outdoor
unit
capacity
is up
to 60 HP in increment of 2 HP.

RX(Y)Q36TSY1(E)
* This
function
is available
* This
function
isRX(Y)Q40TSY1(E)
available
forfor
FTK(X)S50/60/71F.
FTK(X)S50/60/71F.



These
filters
are
not
medical
devices.
Benefits
These
filters

are
not
medical
devices.
Benefits
Triple Outdoor Units
42, 44 HP

When
When
youyou
go go
outout

such
the
adsorption
and
decomposition
such
asas
the
adsorption
and
of of
46, 48, 50
HPdecomposition
bacteria
are
only

effective
substances
that
are
bacteria
are
only
effective
forfor
substances
that
are
collected
and
direct
contact
with
the
Titanium
collected
onon
and
in in
direct
contact
with
the
Titanium
Apatite
Photocatalytic

Air-Purifying
Filter.
Apatite
Photocatalytic
Air-Purifying
Filter.
Bacteria
Removal
Test
Bacteria
Removal
Test
Testing
method:
dropping
method
Testing
method:
dropping
method
Result
certificate:
012553-1
012553-2
Result
certificate:
No.No.
012553-1
andand
012553-2

Testing
organisation:
Japan
Spinners
Inspecting
Foundation
Testing
organisation:
Japan
Spinners
Inspecting
Foundation

RX(Y)Q42TSY1(E)
RX(Y)Q44TSY1(E)
A uniform
temperature
A uniform
temperature
is achieved
throughout
is achieved
throughout
thethe
entire
room.
entire
room.

RX(Y)Q46TSY1(E)

RX(Y)Q48TSY1(E)
RX(Y)Q50TSY1(E)

Hotline: 0976 173 173

143636


Specifications
Indoor Unit
Outdoor
UnitLineup
Lineup
Outdoor
UnitsUnits
Residential
Indoor Units with connection to BP units
VRV
Indoor

Cooling Only / Heat Pump

FDXS25C / FDXS35C
Heating capacity
FDXS50C
/ FDXS60C

High-COP Type

consumption

Double Outdoor Power
Units

12, 14, 16 HP

Cooling

3,400

4,300

5,400

6,900

8,600

10,800

13,800

Btu/h

10,900

13,600

17,100

21,500


27,300

34,100

42,700

54,600

kW

3.2

4.0

5.0

6.3

8.0

10.0

12.5

16.0

kW

0.031


0.031

0.041

Triple kW
Outdoor
Units
0.027
0.027

0.037

18, 20, 22, 24, 26, 28, 30, 32 HP

Airflow rate (H/M/L)
Sound level (H/M/L)

Dimensions (H×W×D)
Machine weight

RX(Y)Q12THY1(E)
RX(Y)Q14THY1(E)
RX(Y)Q16THY1(E) Panel

2,800

Heating

Casing


Piping
connections

kcal/h

0.095

0.095

0.194

0.219

0.075

0.090

0.090

0.180

0.199

34,
38plate
HP
Galvanised
steel


Standard accessory

mm
kg
mm

DrainRX(Y)Q18THY1(E)

246×840×840

19

23

9.5

3.2

200
RX(Y)Q14TY1(E)
RX(Y)Q18TNY1(E)
Cooling
kW mm 0.033
Power consumption
RX(Y)Q16TY1(E)
RX(Y)Q20TNY1(E)
Only 700 mm
0.027
Heating
kW

Casing

4.0

5.0

6.3

8.0

10.0

12.5

Piping
connections

Panel
(Option)

Gas (Flare)
240 mmmm
Drain
Model

Weight

RX(Y)Q18TY1(E)
RX(Y)Q20TY1(E)


36, 40 HP

16.0

mm
kg

9.5

15.9
12.7
Chamber
suction
Signal receiver
VP25 (External
Dia,wire
32/Internal Dia, 25) Air
grille*
Length = 1,900 mm

Signal

BYCP125K-W1 receiver

Option

Fresh white
Notes:

AIR


* Locally obtained parts

1. To prevent an increase in operation noise, avoid
950
50X950X
installing the air suction grille directly below the

5.5 suction chamber.

FTKS50B

1,900

2,400

kcal/h

7,500

3,100
3.6

2.8

3,400

2,800

8,500


13,600

10,900

2.5

4.0

3.2

0.073

0.076

0.064

0.068

42, 44, 46, 48, 50 HP

Casing

m3/min

Sound level (H/L) 230 V

Liquid (Flare)

Model


FXZQ40MVE

12,300

9,600

2,200

Btu/h

FXZQ32MVE

1-phase, 220-240 V/220 V, 50/60 Hz

2.2

FTKS50F / FTKS60F
kW
Cooling / FTKS71F
Power consumption
kW
FTXS50F / FTXS60F
Heating/ FTXS71F
Airflow rate (H/L)

Galvanised steel plate

9/7


9.5/7.5

FXZQ50MVE
4,800

3,900

15,400
4.5

19,100

Standard accessory*
5.6

5,400

4,300

21,500

17,100

6.3

5.0

0.115

0.089

0.080

0.107

Standard accessory*

11/8

14/10

cfm

318/247

335/265

388/282

493/353

dB(A)

30/25

32/26

36/28

41/33


mm

286×575×575

Standard
accessory*

18

kg

6.4

mmRX(Y)Q42THY1(E)* Remote
12.7 accessory wireless remote controller cannot be used.
RX(Y)Q48THY1(E)
controllers other than the standard

RX(Y)Q44THY1(E) RX(Y)Q50THY1(E)
VP20 (External Dia, 26/Internal Dia, 20)
RX(Y)Q46THY1(E)
BYFQ60B8W1

Stylish flat panel harmonises with your interior décor
Panel
(Option)

White (6.5Y9.5/0.5)

Colour


Dimensions(H×W×D)

mm

Weightachieve kg
Wall Mounted indoor units
quiet sound
Triple Outdoor
Units
levels of 22 dB (A) during cooling operation.
(H/L/SL)
42,
44 HP
38, 40 HP
34, 36 HP
4-way Flow Ceiling Suspended Type
FTK(X)S20/25 FTK(X)S35 FTK(X)S50 FTK(X)S60 FTK(X)S71

55×700×700

Titanium apatite
2.7is a photocatalytic material with
high adsorption power. Titanium apatite also
effectively adsorbs
and
bacteria
46, 48,
50,decomposes
52, 54, 56, 58,

60 HP
across its entire surface. The photocatalyst is
activated simply by exposure to light.

MODEL
FXUQ71AVEB
dB (A) 45/36/33 dB (A) 46/37/34 dB (A)
37/25/22 dB (A) 39/26/23 dB (A) 43/34/31
Power supply

RX(Y)Q40TNY1(E)
kW

RX(Y)Q36TNY1(E)

Power consumption

Cooling

kW

Heating

kW

Casing
Airflow rate (H/M/L)

Double Outdoor Units


FXUQ100AVEB

1-phase, 220-240 V/220-230 V, 50/60 Hz

Intelligent Eye with its infrared sensor
kcal/h
6,900
automaticallyCooling
controls
air conditioner
capacity
Btu/hoperation
27,300
according to human movement in akWroom. When
8.0
there is no movement, it adjusts the
temperature
kcal/h
7,700
by 2˚C for energy
Btu/h
Heatingsavings.
capacity
30,700
RX(Y)Q42TNY1(E)
RX(Y)Q38TNY1(E)
RX(Y)Q34TNY1(E)

Sound level (H/M/L)


0.073

11.2

10,800

RX(Y)Q46TNY1(E)
RX(Y)Q48TNY1(E)
RX(Y)Q50TNY1(E)
RX(Y)Q52TNY1(E)
Titanium Apatite

RX(Y)Q44TNY1(E)
9.0
0.090

9,600
38,200

Photocatalytic
Fresh
white
Air-purifying
Filter

Air filter
Catches dust

42,700
RX(Y)Q54TNY1(E)


RX(Y)Q56TNY1(E)
12.5

RX(Y)Q58TNY1(E)
0.200
RX(Y)Q60TNY1(E)

0.179

31/26/21

m3/min

22.5/19.5/16

cfm

794/688/565

1,094/918/741

dB(A)

40/38/36

47/44/40

These filters are not medical devices. Benefits
Triple Outdoor Units


such as the adsorption
34, 36, 38, 40 Dimensions
HP
42, 44 HP
46, 48, 50 and
HP decomposition of
198×950×950
mm
(H×W×D)
bacteria
are
only
effective
for substances
that are
3-D Airflow Machine weight
27
kg
26
collected
on
and
in
direct
contact
with
the
Titanium
combines Vertical

9.5
Liquid (Flare)
Piping
Apatite
Photocatalytic
Air-Purifying
Filter.
and Horizontal
mm
15.9
Gas (Flare)
connections
Auto-Swing to
Drain
VP20 Removal
(ExternalTest
Dia, 26/Internal Dia, 20)
Bacteria
circulate air to every
Testing method: dropping method
Result
certificate:
No.length:
012553-1
and
012553-2
Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB,
Equivalent
piping
7.5 m,

Level
difference: 0 m.
part of a room for•• Heating:
Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB,
Equivalent
piping length:
7.5 Spinners
m, Level difference:
m.
Testing
organisation:
Japan
Inspecting0 Foundation
• Capacity
uniform cooling of
evenof indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
RX(Y)Q46TSY1(E)
large spaces.
RX(Y)Q42TSY1(E)
RX(Y)Q34TSY1(E)
RX(Y)Q38TSY1(E)
• Sound level: Anechoic chamber conversion
value, measured at a point 1.5 m downward from the
unit centre.
When you are in the room

When you go out

RX(Y)Q44TSY1(E)

RX(Y)Q36TSY1(E)
During actual operation, these
values are normally somewhat higher as a result ofRX(Y)Q48TSY1(E)
ambient conditions.
* This functionRX(Y)Q40TSY1(E)
is available for
A uniform temperature
RX(Y)Q50TSY1(E)
is achieved throughout
FTK(X)S50/60/71F.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.



FXZQ25MVE

kW

kW

Piping

2. Grilles, piping connections, ducts, and installation
parts should be obtained locally. Slim Ceiling
Mounted
type
models do
not have drain-up
• Cooling: Indoor temp.: 27°CDB,

19°CWB, Outdoor temp.: 35°CDB, Equivalent
piping length:
7.5 m, Duct
Level
difference:
0 m.
RX(Y)Q22TSY1(E)
RX(Y)Q26TSY1(E)
RX(Y)Q30TSY1(E)
Suction grille (KDGF19A45)
Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: pumps.
7.5 m, Level difference: 0 m.
• Heating: Indoor temp.: 20°CDB,
RX(Y)Q24TSY1(E)
RX(Y)Q32TSY1(E)
3.total
The signal
receiver
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit RX(Y)Q28TSY1(E)
is based on the
capacity
index.unit must be located near the
air suction inlet, because the unit includes a
(See Engineering Data Book for details.)
sensor
remote
are chamber conversion value, measured at a point 1.5 m downward from
Soundcontroller
level: Anechoic
the that

unit detects
centre. room temperature.

Signals from the wireless •
transmitted to the signal receiver.

133735

6.4

Cooling Only

Gas (Flare)
RX(Y)Q36THY1(E)
connections
RX(Y)Q40THY1(E)
Drain

32˚CRX(Y)Q24TNY1(E)
for cooling operation and 10 to 30˚C for
heating operation.
RX(Y)Q30TNY1(E)
0.027
0.034Operation
0.038
0.053
0.075
0.200
* Home
Leave

function
must be set
using the0.174
remote controller
RX(Y)Q26TNY1(E)
RX(Y)Q32TNY1(E)
when going toGalvanised
sleep or leaving
the
house,
and
after waking up or returning
steel plate
home.

Colour
Dimensions(H×W×D)

Cooling Only
Heat Pump

FXZQ20MVE

Btu/h

Machine weight

RX(Y)Q22TNY1(E)
* Home
Leave

can be0.066
selected for
any temperature
18 to
RX(Y)Q28TNY1(E)
0.033
0.047Operation
0.052
0.093
0.187 from0.209

26, 28, 30, 32 HP

Cooling capacity

Dimensions (H×W×D)

FDKS25EA FDKS35EA FDKS25CA
FDKS35CA
13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5
m3/min
Airflow
rate CDXS35EA
(HH/H/L) FDXS25C FDXS35C
CDXS25EA
cfm 459/406/353 459/406/353
530/459/388
671/583/477
742/636/530
1,130/918/706 1,165/989/794

Suspension
bolt* Suction
duct*
Air discharge
duct*565/477/388
Dimensions (H x W x D) 200 x 700 x 620 mm 200 x 900 x 620 mm
Air filter
Space
Saving
Type
dB(A) 30/28.5/27 30/28.5/27
Sound level (HH/H/L)
31/29/27
32/29.5/27
34/31/28
36/33.5/31
43/37.5/32
44/39/34
Air
discharge
grille*
25 kg
Weight
21 kg
X840X840
246
mm
Dimensions
(H×W×D)
X

X840
840
288
3
3
3
Airflow rate
(H)
8.7 m /min
Single
Outdoor
Units
9.5
m /min 10Outdoor
m /min
Double
Units AIR
weight
19.5
22
25
Pa
40kgPa
External static pressure Machine30

22, 24 HP
Liquid (Flare)

MODEL


FTKS25D
Power supply/ FTKS35D
kcal/h
FTXS20D / FTXS25E / FTXS35E

Heating capacity

26

Slim12.7and smooth design
15.9
RX(Y)Q26THY1(E)
I.D. 25×O.D. 32(VP25)
suits yourBYCQ125B-W1
shallow
ceiling
RX(Y)Q34THY1(E)
RX(Y)Q28THY1(E)
6.4

RX(Y)Q20THY1(E)
Model
RX(Y)Q38THY1(E)
RX(Y)Q22THY1(E) RX(Y)Q30THY1(E)
Fresh white
Colour
RX(Y)Q32THY1(E)
RX(Y)Q24THY1(E)
and CDXS-EA
series are

Low operation sound level

kW

18, 20 HP

Space Saving Type

288×840×840

Models in the FDKS-EA
(Option)
(H/L/SL)
50×950×950
Dimensions(H×W×D) mm
only 700 mm in width and 21
kg in weight,
so are
5.5
kg
Weight
FDKS25
FDKS35
FDKS50
FDKS60
easily installed
Standard
Type in limited spaces. Just 200 mm in
C(F)DXS25 C(F)DXS35 FDXS50
FDXS60

height,
all models
can be installed
in rooms
withTypeUnits
Double
Outdoor
Single
Outdoor
Units
Ceiling
Mounted
Cassette
(Round
Flow)
35/31/29 dB (A) 35/31/29 dB (A) 37/33/31 dB (A) 38/34/32 dB (A)
as
little
as
240
mm
depth
between
the
drop
6, 8, 10, 12 HP
14, 16 HP
22, 24, 26 HP
18, 20 HP
28, 30, 32 HP

ceiling and ceiling slab, making
them
ideal
for
FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1
MODEL
Home Leave
Operation
large rises or falls in
Power supply
1-phase,
220-240 V,prevents
50 Hz
even shallow ceilings.
FDKS-EA
the indoor
by continuing
operation*
while
6,100
7,700
9,600
12,000
2,400
3,100
3,900 temperature
4,800
kcal/h
CDXS-EA
Great for

Cooling capacity
9,600
12,300
15,400
19,100
38,200means
Btu/h
47,800
you are
sleeping
or out
of your30,700
home. This
that
24,200
hotel use!
2.8
3.6
4.5
5.6 welcome
kW
9.0 when
11.2
7.1 awaits
14.0 or
an air-conditioned
you wake
2,800
3,400
5,400

kcal/h
6,900
8,600
10,800 13,800
return.4,300
It also means
that
the indoor
temperature
can
13,600
17,100
21,500 27,300
Btu/h 10,900
Heating capacity
34,100
42,700 54,600
quickly return to your favourite comfort setting.
RX(Y)Q6TY1(E)
RX(Y)Q8TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q12TY1(E)

Cooling Only
High-COP Type
Heat Pump
Standard Type

Note:33.0/26.0/19.0
Remote controllers

34.5/27.5/21.0
m3/min 12.5/11.5/10.0 12.5/11.5/10.0 14.5/13.0/11.0 22.0/17.5/13.5 23.5/18.5/13.5 23.5/19.5/15.0
other than the standard
cfm 441/406/353 441/406/353 512/459/388 777/618/477 830/653/477 830/688/530
1,165/918/671
1,218/971/741
accessory
wireless
remote
controller cannot be used.
dB(A) 30/28.5/27 30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35

Liquid (Flare)
Gas (Flare)

0.080

HP

New Lineup

Specifications
Indoor Unit Lineup

VRV IV outdoor unit offers a higher capacity
of up to 60 HP,FXFQ25SVM
responding
to theFXFQ40SVM
needs ofFXFQ50SVM
large-sized

building.
FXFQ32SVM
FXFQ63SVM
FXFQ80SVM FXFQ100SVM FXFQ125SVM
MODEL
The single outdoor
unit
has
only
2
different
shapes
and
dimensions,
not
only
simplifying
the
design
process,
but also bringing the
Power supply / FDKS35EA
Cooling Only FDKS25EA
1-phase, 220 -240 V/220-230 V, 50/60 Hz
system flexibility to a new level.
kcal/h
4,800
3,100
3,900
7,700

9,600
12,000
6,100
2,400
FDKS25CA / FDKS35CA
With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.
Cooling capacity
12,300
15,400 19,100
30,700
38,200 47,800
24,200
9,600
Btu/h
FDKS50C
/
FDKS60C
Outdoor units with anti-corrosion specifications (-E type on request) are designed specifically for use in areas which are subject to
7.1
5.6
3.6
4.5
2.8
9.0
11.2
14.0
Heat Pump CDXS25EA / CDXS35EAkW
salt damage and atmospheric
pollution.


Mo/C

Outdoor Unit Lineup

Lineup
Wall Mounted
Ceiling
MountedType
Cassette (Compact Multi Flow) Type

Ceiling
Mounted
Cassette
with
Sensing)ofType
Slim
Ceiling
Mounted
Duct
The
outdoor
unit
capacity
is(Round
upType
to 60Flow
HP in
increment
2 HP.




the entire room.

Hotline: 0976 173 173

143836


Indoor Unit
Outdoor
UnitLineup
Lineup
Specifications
Outdoor
UnitsUnits
Residential
Indoor Units with connection to BP units
VRV
Indoor

Cooling Only / Heat Pump
Lineup
WallCeiling
Mounted
Type Duct Type (700 mm width type)
Slim
Mounted

2,200


FDXS25C / FDXS35C
Btu/h
FDXS60C

Heating
capacity/
FDXS50C

High-COP Type

Power consumption
Double Outdoor
Units

12, 14, 16 HPCasing

8,500

kW

Cooling

kW

0.077

3.2

4.0


0.092

0.092

4,300

17,100
5.0
0.130
0.097

5,400

6,900

21,500

27,300

6.3

8.0

0.130

0.161

0.097


0.126

34,plate
38 HP
18, 20, 22, 24, 26, 28, 30, 32 HPGalvanised steel

m /min

7/5

3

Airflow rate (HH/M/L)

cfm
dB(A)

220 V

mm

Dimensions (H×W×D)

9/6.5

9/6.5

12/9

12/9


247/177

318/230

318/230

424/318

424/318

32/27

34/28

34/28

34/29

34/29

26.0

26.0

26.0

31.0

32.0


RX(Y)Q14THY1(E)
RX(Y)Q16THY1(E)
Panel

Colour

13,800
54,600

10.0

16.0

0.209

0.256

0.176

0.223

Standard accessory

16.5/13 Note:26/21
33/25
Remote controllers

47.0


RX(Y)Q38THY1(E)
RX(Y)Q22THY1(E) RX(Y)Q30THY1(E)
White (10Y9/0.5)
RX(Y)Q32THY1(E)
RX(Y)Q24THY1(E)
CDXS-EA
series are
Low operation sound level

RX(Y)Q6TY1(E)
RX(Y)Q8TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q12TY1(E)

0.066
200 mm
0.046
kW
RX(Y)Q18TNY1(E)

kW

RX(Y)Q14TY1(E)
Heating
RX(Y)Q16TY1(E)
Casing
Only 700 mm

RX(Y)Q20TNY1(E)


11/9
m3/min
cfm
388/318
FDKS25EA FDKS35EA FDKS25CA
FDKS35CA
CDXS25EA
FDXS25C FDXS35C
Sound
level (H/L)CDXS35EA
220 V dB(A)
38/33
x 620
mm
Dimensions (H x W x D)
200 x 700
x 620 mm 200
X1,110X710
Dimensions
(H×W×D)
mm x 900215

Airflow rate (H/L)

Space
Saving Type
Weight

25 kg 31
9.5

m3/min 10Outdoor
m3/min
Double
6.4
40 Pa 12.7

21 kg
Machine weight

kg

Airflow rate
(H)
8.7Liquid
m /min
Single
Outdoor
Units
(Flare)
3

Piping
External static pressure

18, 20 HP

30 Pa

connections Gas (Flare)
Drain

Model

Panel
(Option)

Colour

mm22,

24 HP

mm

0.076

0.105

RX(Y)Q22TNY1(E)
* Home
Leave
any temperature
from 18 to
0.046Operation can be selected
0.056 forRX(Y)Q28TNY1(E)
0.085
32˚CRX(Y)Q24TNY1(E)
for cooling operation and 10 to 30˚C for
heating operation.
RX(Y)Q30TNY1(E)
Galvanised steel plate

* Home
Leave Operation function must be set using the remote controller
RX(Y)Q26TNY1(E)
RX(Y)Q32TNY1(E)
11/9to sleep or leaving the
13/10
18/15
when going
house, and after waking
up or returning
home. 388/318
459/353
635/530
38/33

Air discharge duct*

215X1,110X710

Air discharge grille*

31

Units AIR
6.4

12.7

40/34


Suspension bolt*

Suction duct*

215X1,110X710
31

70X1,240X800

9.5

12.732 HP
26, 28, 30,

BYK45FJW1 Chamber
Signal receiver wire
White
(10Y9/0.5)
Length = 1,900
mm
Signal
receiver
70X1,240X800
70X1,240
X800

AIR

15.9
BYK71FJW1


Air suction
grille*

*70
Locally
obtained
X1,440
X800parts

Notes: 8.5
9.5
1. To prevent an increase in operation noise, avoid
Option
Note: Specifications are based on the following conditions;
installing the air suction grille directly below the
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5suction
m, Level
difference: 0 m.
chamber.
•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 2.
m,Grilles,
Level difference:
0 m. ducts, and installation
piping connections,
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity
index.
parts should be obtained locally. Slim Ceiling
(See Engineering Data Book for details.)
Mounted Duct type models do not have drain-up

RX(Y)Q18TY1(E) •Sound level: (FXCQ-M) AnechoicRX(Y)Q22TSY1(E)
RX(Y)Q26TSY1(E)
RX(Y)Q30TSY1(E)
chamber conversion value, measured
at a (KDGF19A45)
point
1.5 m downward
from the
unit centre.
Suction grille
pumps.
(FXKQ-MA) Anechoic
chamber conversion value, measured at a point
1 m in front of the unitRX(Y)Q32TSY1(E)
and 1 m downward.
RX(Y)Q24TSY1(E)
RX(Y)Q20TY1(E)
RX(Y)Q28TSY1(E)
3. The signal receiver unit must be located near the
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
air suction inlet, because the unit includes a
sensor that detects room temperature.
Signals from the wireless remote controller are

Weight

kg

8.5


8.5

transmitted to the signal receiver.

133935



Cooling capacity

Cooling Only

FTKS50B

1,900

Btu/h

7,500

Heating
Cooling
Heating

External static pressure

1 3

Dimensions (H×W×D)


RX(Y)Q36THY1(E)
Machine weight
RX(Y)Q40THY1(E)

Liquid (Flare)

FXDQ25PBVE
FXDQ25PBVET

1-phase, 220-240 V/220 V, 50/60 Hz

FXDQ32PBVE
FXDQ32PBVET
3,100

2,400

Standard accessory*
12,300

9,600

kW

2.2

2.8

3.6


kcal/h

2,200

2,800

3,400

Btu/h

8,500

10,900

13,600

2.5

3.2

4.0

0.086

0.086

0.089

0.067


0.067

FTKS50F / FTKS60F /
Cooling
kW
Power consumption
FTXS50F
/ FTXS60F
/ FTXS71F
(FXDQ-PBVE) 1
Power consumption
(FXDQ-PBVET) 1

FXDQ20PBVE
FXDQ20PBVET

kcal/h

kW
FTKS71F

Sound level (HH/H/L)

kW
kW

42, 44, 46,0.067
48, 50 HP

0.070

Standard accessory*

0.067

0.070

kW

0.067

m3/min

8.0/7.2/6.4

8.0/7.2/6.4

8.0/7.2/6.4

282/254/226

282/254/226

282/254/226

dB(A)

33/31/29

33/31/29


mm

200×700×620

200×700×620

200×700×620

23.0

23.0

cfm

0.067

Galvanised steel plate

Pa

30-10

0.070

2

Standard

accessory*
33/31/29


RX(Y)Q42THY1(E)* Remote
RX(Y)Q48THY1(E)
controllers other than the standard accessory wireless remote controller cannot be used.

kg RX(Y)Q44THY1(E)
23.0 RX(Y)Q50THY1(E)
6.4
RX(Y)Q46THY1(E)

6.4

6.4

Stylish flat panel harmonises with your interior décor
Piping
Gas (Flare)
connections
Drain

mm

Cooling capacity

Btu/h

12.7

12.7


12.7

VP20 (External Dia, 26/Internal Dia, 20)

apatite is a photocatalytic material with
Mounted
indoor units
achieve
sound
Slim Wall
Ceiling
Mounted
Duct
Typequiet
(900/1,100
mmTitanium
width type)
Triple Outdoor
Units
high
adsorption
power. Titanium apatite also
levels of 22 dB (A) during cooling operation.
FXDQ40NBVE effectivelyFXDQ50NBVE
FXDQ63NBVE
with drain pump
adsorbs
and
bacteria
(H/L/SL)

MODEL
42,
44 HP
46, 48,
50,decomposes
52, 54, 56, 58,
60 HP
38, 40 HP without drain pump
34, 36 HP
FXDQ40NBVET
FXDQ50NBVET
FXDQ63NBVET
across
its
entire
surface.
The
photocatalyst
is
FTK(X)S50 FTK(X)S60 FTK(X)S71
FTK(X)S20/25 FTK(X)S35
Power supply
1-phase, 220-240 V/220 V, 50/60 Hz
activated simply by exposure to light.
4,800
6,100
kcal/h
dB (A) 46/37/34 dB3,900
(A)
37/25/22 dB (A) 39/26/23 dB (A) 43/34/31 dB (A) 45/36/33

15,400

Intelligent Eye with its infrared sensor
kW
4.5
automatically controls air conditioner
kcal/hoperation 4,300
Heating capacity
17,100
according to human
movement in Btu/h
a room. When
kWtemperature5.0
there is no movement, it adjusts the
Cooling
0.160
kW
Power consumption
by 2˚C for energy
savings.
RX(Y)Q42TNY1(E)
RX(Y)Q38TNY1(E)
RX(Y)Q34TNY1(E)
RX(Y)Q36TNY1(E)

(FXDQ-PBVE)

1

Heating

kW
RX(Y)Q40TNY1(E)

Power consumption
(FXDQ-PBVET) 1

Cooling

Heating

kW
kW

Airflow rate (HH/H/L)

Double Outdoor
External Units
static pressure

m3/min
cfm

19,100

10.5/9.5/8.5
371/335/300

24,200

5.6


7.1

5,400

6,900

21,500

27,300

6.3

0.165
RX(Y)Q46TNY1(E)
0.152
0.147
RX(Y)Q44TNY1(E)
RX(Y)Q48TNY1(E)
RX(Y)Q50TNY1(E)
0.152
0.147
RX(Y)Q52TNY1(E)
0.152
0.147
Titanium Apatite

Casing

Air 215

filter X1,310X710

34

FTKS25D /
Power supply
FTXS20D
/ FTXS25E / FTXS35E

Airflow rate (HH/H/L)

42/37

6.4

VP25 (External Dia, 32/Internal Dia, 25)

240 mm

Dimensions(H×W×D)

0.066

without drain pump
FTKS35D

Casing

48.0


9.5
9.5
Slim and smooth design
15.9
15.9
suits your
shallow
ceiling
RX(Y)Q34THY1(E)
RX(Y)Q28THY1(E)
RX(Y)Q20THY1(E) BYBC32G-W1
BYBC63G-W1
BYBC125G-W1
BYBC50G-W1

Cooling

36, 40 HP

cannot be44/38
used.
37/32 controller
39/34

35.0

with drain pump

MODEL


Heating capacity

Cooling Only
Heat Pump

other than the standard

Models in the(Option)
FDKS-EA
and
(H/L/SL)
Dimensions(H×W×D) mm 53×1,030×680 53×1,030×680 53×1,030×680 53×1,245×680 53×1,245×680 53×1,430×680 53×1,920×680 53×1,920×680
only 700 mm in width Weight
and 21 kg in kg
weight,8.0so are 8.0
8.0
8.5
8.5
9.5
12.0
12.0
FDKS25
FDKS35
FDKS50
FDKS60
easily installed
Standard
Type in limited spaces. Just 200 mm in
C(F)DXS25 C(F)DXS35 FDXS50
FDXS60

height,
all models
can be installed
in rooms
with
Ceiling
Mounted
Cassette
Corner
Type
Double
Outdoor
Units
Single
Outdoor
Units
35/31/29 dB (A) 35/31/29 dB (A) 37/33/31 dB (A) 38/34/32 dB (A)
as
little
as
240
mm
depth
between
the
drop
6, 8, 10, 12 HP
14, 16 HP
22, 24, 26 HP
18, 20 FXKQ25MAVE

HP
28, 30, 32
HP
FXKQ32MAVE
FXKQ40MAVE
FXKQ63MAVE
MODEL
ceiling and ceiling
slab,
making
them
ideal
for
Power supply
1-phase, 220 -240 V/220 V, 50/60 Hz
Home Leave Operation prevents large rises or falls in
even shallow ceilings.
2,400
3,100
3,900
6,100
FDKS-EA kcal/h
the indoor
temperature by
continuing operation*
while
9,600
12,300
15,400
24,200

Btu/h
CDXS-EA
Great for Cooling capacity
you are3.6
sleeping or out of4.5
your home. This 7.1
means that
kW
2.8
hotel use!
2,800
3,400
4,300awaits when you
6,900wake or
kcal/h
an air-conditioned
welcome
10,900
13,600
17,100
27,300
Heating capacity
Btu/h
return. It also means that the indoor temperature can
3.2
4.0
5.0
8.0
kW
quickly return to your favourite comfort setting.

Power consumption

Space Saving Type

582/459 accessory
918/741
1,165/883
wireless
remote

6.4
6.4
6.4
6.4
6.4
9.5
Liquid (Flare)
Piping
mm
Gas (Flare)
12.7
12.7
12.7
12.7
12.7
15.9
connections
Drain
RX(Y)Q18THY1(E) RX(Y)Q26THY1(E)
VP25 (External Dia, 32/Internal Dia, 25)

RX(Y)Q12THY1(E)
Model

8,600

34,100

Cooling Only
High-COP Type
Heat Pump
Standard Type

305×775×600 305×775×600 305×775×600 305×990×600 305×990×600 305×1,175×600 305×1,665×600 305×1,665×600

kg

Machine weight

13,600

Triple
Outdoor
Units0.059
kW
0.059
0.044

Heating

Sound level (H/L)


2.5

10,900

HP

New Lineup

Outdoor Unit Lineup

VRV IV outdoor unit offers a higher
capacity of up to 60
HP, responding
the needs
of large-sized
building.
FXCQ50MVE
MODEL
FXCQ20MVE
FXCQ25MVE toFXCQ32MVE
FXCQ40MVE
FXCQ63MVE FXCQ80MVE FXCQ125MVE
The single outdoor
unit
has
only
2
different
shapes

and
dimensions,
not
only
simplifying
the
design
process,
Power
supply
1-phase,
220-240
V/220
V,
50/60 Hz but also bringing the
Cooling Only FDKS25EA / FDKS35EA
system flexibility to a new level.
4,800
kcal/h
1,900
2,400
3,100
6,100
7,700
12,000
3,900
FDKS25CA
/ FDKS35CA
With the outdoor unit capacity
increased in increment

of7,500
2 HP, customers'
needs
can15,400
be precisely
met. 24,200
Cooling capacity
Btu/h
19,100
9,600
12,300
30,700
47,800
FDKS50C / FDKS60C type on request) are designed specifically for use in areas which are subject
Outdoor units with anti-corrosion specifications (-E
to
5.6
kW
2.2
2.8
3.6
7.1
9.0
14.0
4.5
Heat Pump CDXS25EA / CDXS35EA
salt damage and atmospheric pollution.
kcal/h
2,800
3,400


Mo/C

Photocatalytic
Galvanised steel plate
Air-purifying Filter

Specifications
Indoor Unit Lineup

Slim
Ceiling
Mounted
Duct
The
outdoor
unit
capacity
is(Double
upType
to 60Flow)
HP inType
increment of 2 HP.
Ceiling
Mounted
Cassette

8.0Air filter

Catches dust


0.181
RX(Y)Q54TNY1(E)
0.168
RX(Y)Q56TNY1(E)
RX(Y)Q58TNY1(E)
0.168
RX(Y)Q60TNY1(E)
0.168

12.5/11.0/10.0

16.5/14.5/13.0

441/388/353

583/512/459

These filters are
not medical devices. Benefits
Triple
Outdoor Units
Pa
44-15 2

in the room
1 3 you go out
35/33/31
36/34/32 of
dB(A)

Sound
34,When
36,you
38,are40
HP level (HH/H/L)When
42, 44 HP 34/32/30 such as the adsorption
46, 48, 50 and
HP decomposition
only effective for substances
that are
3-D Airflow Dimensions (H×W×D)
200×900×620 bacteria are
200×900×620
200×1,100×620
mm
collected on and
the Titanium
Machine weight
27.0
28.0in direct contact with
31.0
kg
combines Vertical
Apatite Photocatalytic
Air-Purifying Filter.
Liquid (Flare)
6.4
6.4
6.4
and Horizontal

Piping
12.7
12.7
12.7
mm
Auto-Swing toconnections Gas (Flare)
Bacteria Removal Test
VP20method:
(External
Dia, 26/Internal
circulate air to every Drain
Testing
dropping
method Dia, 20)
Result certificate: No. 012553-1 and 012553-2
part of a room for• Cooling: Indoor temp.: 27℃DB, 19℃WB, Outdoor temp.: 35℃DB, Equivalent
piping length: 7.5 m, Level difference: 0 m.
Testing
organisation:
Japan
Spinners Inspecting Foundation
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit
is based
on the total capacity
index.
uniform cooling of
even
(See
Engineering Data Book for details.)
• Heating: Indoor temp.: 20℃DB, Outdoor temp.: 7℃DB, 6℃WB, Equivalent piping length: 7.5 m, Level difference: 0 m.

large spaces.
RX(Y)Q42TSY1(E)
RX(Y)Q34TSY1(E)
RX(Y)Q38TSY1(E)
• Sound level: Anechoic chamber conversion
value, measured at a point 1.5 m downward from the RX(Y)Q46TSY1(E)
unit centre.
actual operation, these
values are normally somewhat higher as a result of ambient
conditions.
RX(Y)Q48TSY1(E)
RX(Y)Q44TSY1(E)
RX(Y)Q36TSY1(E)
* This functionRX(Y)Q40TSY1(E)
is available
for areDuring
A uniform
temperature
1: Values
based on the following
conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.
is achieved
throughout
to set
by the remote controller. This pressure means "HighRX(Y)Q50TSY1(E)
static pressure - Standard". (Factory setting is
FTK(X)S50/60/71F. 2: External static pressure is changeable




room.
10 Pa for FXDQ-PB models the
and entire
15 Pa for
FXDQ-NB models.)
3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be
obtained by adding 5 dB(A).

Hotline: 0976 173 173

144036


Indoor Unit
Outdoor
UnitLineup
Lineup
Specifications
Outdoor
UnitsUnits
Residential
Indoor Units with connection to BP units
VRV
Indoor

Cooling Only / Heat Pump
Lineup
Wall Mounted
Ceiling

MountedType
Duct Type

kcal/h
FDXS25C / FDXS35C
Btu/h
FDXS60C

Heating
capacity/
FDXS50C

High-COP Type
Double

Power
consumption
Outdoor
Units

12, 14, 16 HP Casing

Cooling
Heating

External static pressure
Sound level (HH/H/L)

Dimensions (H×W×D)


2,800

3,400

4,300

5,400

8,500

10,900

13,600

17,100

21,500

kW

2.5

kW

0.056

1

0.060


1

0.151

1

0.128

1

1

0.073

1

0.182

1

0.203

1

34,plate
38 HP
18, 20, 22, 24, 26, 28, 30, 32 HPGalvanised steel
9/7.5/6.5

cfm


318/265/230

Pa

30-100 (50)

2

Standard accessory

9/7.5/6.5

9.5/8/7

Note: Remote
controllers
16/13/11
18/16.5/15

318/265/230

335/282/247

accessory wireless
remote
565/459/388
635/582/530

30-100 (50)


2

30-100 (50)

2

RX(Y)Q16THY1(E)

Drain

33/31/29

34/32/30

39/37/35

41/39/37

mm

300X550X700

300X550X700

300X550X700

300X700X700

300X1,000X700


kg

25

6.4

VP25 (External Dia, 32/Internal
Dia, 25)
RX(Y)Q38THY1(E)

RX(Y)Q22THY1(E) RX(Y)Q30THY1(E)
RX(Y)Q32THY1(E)
RX(Y)Q24THY1(E)
CDXS-EA
series are
Low operation

Models in the FDKS-EA and
sound level
(H/L/SL)
only 700 mm in width and 21 kg in weight, so are
FDKS25
FDKS35
FDKS50
FDKS60
MODEL
FXMQ63PVE
FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE
easily installed

spaces. Just 200
mm in
Standard
Type in limited
C(F)DXS25
C(F)DXS35
FDXS60
FDXS50
1-phase, 220-240 V/220 V, 50/60 Hz
Power supply
height,
all models
can be installed
in roomsOutdoor
with
Double
Units
Single
Outdoor
Units
kcal/h
6,100
7,700
9,600 dB (A)
12,000
13,800
35/31/29 dB (A) 35/31/29
dB (A)
37/33/31
dB (A) 38/34/32

as 240 14,
mm depth
the20
drop
6, 8,as
10,little
12 HP
HP betweenBtu/h
22, 24, 26 HP38,200
18,
HP24,200
28,
30, 32 HP 54,600
Cooling16
capacity
30,700
47,800
ceiling and ceiling slab, making them
ideal
for
kW
7.1
9.0
11.2
14.0
Home
Leave Operation
prevents
large rises 16.0
or falls in

even shallow ceilings.
kcal/h
15,500
13,800
10,800
8,600
6,900
FDKS-EA
the indoor temperature by continuing operation* while
61,400
54,600
42,700
34,100
27,300
Heating capacity CDXS-EA Btu/h
Great for
you
are sleeping12.5
or out of your16.0
home. This means
that
kW
18.0
10.0
8.0
hotel use!
an
air-conditioned
welcome
awaits

when
you
wake
or
1
1
1
1
1
kW
0.405
0.284
0.215
0.185
0.138
Cooling
Power consumption
1
1
1
1
1
return.
temperature
kW
0.449 can
0.449
0.364 that the indoor
0.286 It also means
0.218

Heating
Galvanised
steelfavourite
plate
Casing
quickly return
to your
comfort setting.
RX(Y)Q6TY1(E)
RX(Y)Q8TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q12TY1(E)

19.5/17.5/16
200 mm
RX(Y)Q18TNY1(E)
cfm
688/618/565

Airflow
rate (HH/H/L)
RX(Y)Q14TY1(E)

RX(Y)Q16TY1(E)
Only 700 mm

RX(Y)Q20TNY1(E)

Pa


External static pressure
Sound level (HH/H/L)

dB(A)

50-200 (100)

42/40/38

2

25/22.5/20
32/27/23
39/33/28
46/39/32
RX(Y)Q22TNY1(E)
* Home
Leave Operation can be selected forRX(Y)Q28TNY1(E)
any temperature from 18 to
883/794/706
1,130/953/812
1,377/1,165/988
1,624/1,377/1,130
32˚CRX(Y)Q24TNY1(E)
for cooling operation and 10 to 30˚C for
heating operation.
RX(Y)Q30TNY1(E)
2 remote
* Home
Leave2 Operation

be set (100)
using the
50-200
(100)
50-200function
(100) 2 must50-200
50-140controller
(100) 2
RX(Y)Q26TNY1(E)
RX(Y)Q32TNY1(E)
when going to sleep or leaving the house, and after waking up or returning
43/41/39
43/41/39
44/42/40
46/45/43
home.

FDKS25EA FDKS35EA FDKS25CA FDKS35CA
mm
300FDXS35C
X1,000X700 300X1,000X700 300X1,400X700 300X1,400X700 300X1,400X700
FDXS25C
bolt* Suction
Air
kg x 900 x 62036mm
36discharge duct* Suspension
46
46duct* Air filter
47
Dimensions (H x W x D)Machine

200 xweight
700 x 620 mm 200
Space
Saving Type 21
Air discharge grille*
25 kg 9.5
Weight
kg (Flare)
Liquid
9.5
9.5
9.5
9.5
Piping
3/min
Airflow rate
(H)
8.7Gas
m3/min
Single
Outdoor
Units
9.5
m3/min 10Outdoor
m
Double
Units
mm
(Flare)
15.9

15.9
15.9
15.9
15.9
connections
AIR
30
Pa
40 Pa
External static pressure
Drain
VP25 (External Dia, 32/Internal Dia, 25)
Dimensions
(H×W×D)
CDXS25EA
CDXS35EA

18, 20 HP

22, 24 HP

26, 28, 30, 32 HP

Note: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB,mm
19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 Chamber
m, Level difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping
Air suction
Signallength:

receiver7.5
wirem, Level difference: 0 m.
grille*
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based
on
the
total
capacity
index.
=
Length 1,900 mm
Signal
(See Engineering Data Book for details.)
* Locally obtained parts
receiver
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result ofNotes:
ambient conditions.
1. To prevent an increase in operation noise, avoid
1: Power consumption values are based on conditions of rated external
Option static pressure.
installing
the air(FXMQ40P),
suction grillefourteen
directly below
the
2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P),
thirteen
(FXMQ50suction
chamber.

125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible
static
pressures. The standard static
2.
Grilles,
piping
connections,
ducts,
and
installation
pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P.
parts should be obtained locally. Slim Ceiling
Mounted Duct type models do not have drain-up
RX(Y)Q22TSY1(E)
RX(Y)Q18TY1(E)
RX(Y)Q26TSY1(E)
RX(Y)Q30TSY1(E)
Suction grille (KDGF19A45)
pumps.
RX(Y)Q24TSY1(E)
RX(Y)Q20TY1(E)
RX(Y)Q28TSY1(E)
3. The signal RX(Y)Q32TSY1(E)
receiver unit must be located near the
air suction inlet, because the unit includes a
sensor that detects room temperature.
Signals from the wireless remote controller are

240


AIR

transmitted to the signal receiver.

134135



36, 40 HP

FXMQ200MAVE

MODEL

FTKS25D
/ FTKS35D
Power supply
FTXS20D / FTXS25E / FTXS35E
kcal/h
Cooling capacity

Cooling Only

FTKS50B

1-phase, 220 -240 V/220 V, 50/60 Hz
95,500

kcal/h


22.4

21,500

28.0
27,100

Btu/h

85,300

107,500

kW

kW

25.0

m /min

Sound level(H/L)

220 V

Dimensions (H×W×D)

1.465

1


1.294

1

1.465

1

mm

Liquid (Flare)

Piping
RX(Y)Q36THY1(E)
connections Gas (Flare)
RX(Y)Q40THY1(E)

Galvanised steel plate

Standard accessory*

58/50

72/62
2,542/2,189

132-221

191-270


dB(A)
kg

Machine weight

Drain

Pa

31.5
1

2,047/1,765

3

cfm

Standard accessory*

1.294

42, 44, 46, 48, 50 HP

External static pressure

24,100

76,400


FTKS50F / FTKS60F
/ FTKS71F
kW
Cooling
Power consumption
FTXS50F
/ FTXS60F
/
FTXS71F
kW
Heating
Casing

FXMQ250MAVE

19,300

Btu/h

Airflow rate (H/L)

50-200 (100)

33/31/29

m3/min

Cooling Only
Heat Pump


controller
cannot be used. 2
2

30-160 (100)

dB(A)

Liquid (Flare)

Space Saving Type

other than the standard

25
28
36
Slim256.4 and smooth
design
6.4
6.4
6.4
Piping
RX(Y)Q26THY1(E)
RX(Y)Q18THY1(E)
Gas
(Flare)
mm
12.7

12.7
12.7
12.7
12.7
RX(Y)Q12THY1(E)
suits your shallow
ceiling
connections
RX(Y)Q34THY1(E)
RX(Y)Q20THY1(E) RX(Y)Q28THY1(E)
RX(Y)Q14THY1(E)

Machine weight

Cooling Only
High-COP Type
Heat Pump
Standard Type

Heating capacity

6.3

5.0

4.0

3.2
0.056


1

Triple
Outdoor
Units
kW
0.069
0.069 1
m3/min

Airflow rate (HH/H/L)

2,200

HP

New Lineup

2

2

48/45

48/45

470X1,380X1,100

470X1,380X1,100


137

137

9.5

Standard
accessory*

9.5

RX(Y)Q48THY1(E)
mmRX(Y)Q42THY1(E)* Remote
19.1controllers other than the standard accessory wireless remote
22.2controller cannot be used.
RX(Y)Q44THY1(E) RX(Y)Q50THY1(E)
PS1B
RX(Y)Q46THY1(E)

Stylish flat panel harmonises with your interior décor
Titanium apatite is a photocatalytic material with
high adsorption power. Titanium apatite also
effectively adsorbs
and
bacteria
(H/L/SL)
42,
44 HP
46, 48,
50,decomposes

52, 54, 56, 58,
60 HP
38, 40 HP
34, 36 HP
FXHQ32MAVEacross itsFXHQ63MAVE
FXHQ100MAVEis
MODEL
entire
surface.
The
photocatalyst
FTK(X)S20/25 FTK(X)S35 FTK(X)S50 FTK(X)S60 FTK(X)S71
1-phase, 220-240
V, 50/60 Hz to light.
Power supply
activated
simplyV/220
by exposure
dB (A) 46/37/34 dB3,100
(A)
37/25/22 dB (A) 39/26/23 dB (A) 43/34/31 dB (A) 45/36/33
9,600
kcal/h
6,100
Wall Mounted indoor units achieve quiet sound

Ceiling
Suspended
Triple
Outdoor

Units
levels
of 22
dB (A) Type
during cooling operation.

Cooling capacity

Btu/h

12,300

Intelligent Eye with its infrared sensor
kW
3.6
automatically controls air conditioner
operation
kcal/h
3,400
according to human
movement in Btu/h
a room. When
Heating capacity
13,600
there is no movement, it adjusts the
kWtemperature4.0
by 2˚C for energy savings.
RX(Y)Q42TNY1(E)
RX(Y)Q38TNY1(E)
Cooling

kW
RX(Y)Q34TNY1(E)
0.111
RX(Y)Q36TNY1(E)

Power consumption
RX(Y)Q40TNY1(E)
Heating
kW
Casing

Sound level (H/L)

12/10

cfm

424/353

dB(A)

Dimensions (H×W×D)

Double Outdoor Units

RX(Y)Q44TNY1(E)

0.111

m3/min


Airflow rate (H/L)

Outdoor Unit Lineup

VRV IV outdoor unit offers a higher capacity of up to 60 HP, responding to the needs of large-sized building.
MODEL
FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE
The single outdoor
unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing the
Cooling Only
1-phase, 220-240 V/220 V, 50/60 Hz
Power
supply
FDKS25EA
/
FDKS35EA
system flexibility to a new level.
kcal/h
1,900
2,400
3,100
3,900
4,800
FDKS25CA
/
FDKS35CA
With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.
Cooling
capacity/ FDKS60C

Btu/h
7,500
9,600
12,300
15,400
19,100
FDKS50C
Outdoor units with anti-corrosion specifications (-E type on request) are designed specifically for use in areas which are subject to
Heat Pump CDXS25EA / CDXS35EA
kW
2.2
2.8
3.6
4.5
5.6
salt damage and atmospheric
pollution.

Mo/C

mm

36/31

195×960×680

24,200

38,200


7.1

11.2

6,900

10,800

27,300

42,700

8.0

Specifications
Indoor Unit Lineup

Slim
Ceiling
Mounted
Duct
The
outdoor
unit
capacity
is upType
to 60 HP in increment of 2 HP.
Ceiling
Mounted
Duct Type


Air filter

12.5Catches dust

RX(Y)Q46TNY1(E) RX(Y)Q54TNY1(E)
0.115
0.135
RX(Y)Q48TNY1(E) RX(Y)Q56TNY1(E)
0.115
0.135

RX(Y)Q50TNY1(E) RX(Y)Q58TNY1(E)
RX(Y)Q52TNY1(E) RX(Y)Q60TNY1(E)
Titanium Apatite
White (10Y9/0.5)
17.5/14

Photocatalytic
Air-purifying
Filter
618/494

39/34

195×1,160×680

25/19.5

883/688

45/37

195×1,400×680

These filters are not medical devices. Benefits
Triple Outdoor Units

kg
24.0
28.0
33.0
such as the adsorption
of
34, 36, 38, 40 HP
42, 44 HP
46,
48, 50 and
HP decomposition
Liquid (Flare)
6.4
9.5
9.5
bacteria are only effective for substances
that are
3-D Airflow Piping
mm
12.7
15.9
15.9
connections Gas (Flare)

collected on and in direct contact with the Titanium
combines Vertical
Drain
VP20 (External Dia, 26/Internal Dia, 20)
Apatite Photocatalytic Air-Purifying Filter.
and Horizontal
Equivalent piping length: 7.5 m, Level difference: 0 m.
Auto-Swing to • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB,
Bacteria
Removal
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB,
Equivalent
piping Test
length: 7.5 m, Level difference: 0 m.
circulate air to every
method:
dropping
method
• Capacity of indoor unit is only for reference. Actual capacity of Testing
indoor unit
is based
on the total
capacity index.
(See Engineering Data Book for details.)
Result certificate: No. 012553-1 and 012553-2
part of a room for• Sound
level: (FXMQ-MA) Anechoic chamber conversion value,Testing
measured
at
a

point
1.5
m
downward
from
the unit centre.
organisation: Japan Spinners
Inspecting
Foundation
uniform cooling of even (FXHQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions
RX(Y)Q46TSY1(E)
large spaces.
RX(Y)Q42TSY1(E)
RX(Y)Q34TSY1(E)
RX(Y)Q38TSY1(E)
1: Power consumption values are based
on conditions of standard external static pressure.
Machine weight

When you are in the room

When you go out

2: External static pressure is changeable
to change over the connectors inside electrical box, thisRX(Y)Q48TSY1(E)
pressure means "Standard-High static pressure".
RX(Y)Q44TSY1(E)
RX(Y)Q36TSY1(E)
* This functionRX(Y)Q40TSY1(E)

is available
for
A uniform temperature
RX(Y)Q50TSY1(E)
is achieved throughout
FTK(X)S50/60/71F.



the entire room.

Hotline: 0976 173 173

144236


Indoor Unit
Outdoor
UnitLineup
Lineup
Specifications
Outdoor
UnitsUnits
Residential
Indoor Units with connection to BP units
VRV
Indoor

Cooling Only / Heat Pump
Lineup

WallStanding
Mounted Duct
Type Type
Floor

FDXS25C / FDXS35C
kcal/h
FDXS50C
Btu/h
Heating
capacity/ FDXS60C

High-COP Type

Double Outdoor
PowerUnits
consumption
12, 14, 16 HP

Cooling

2,200

2,800

3,400

4,300

5,400


6,900

8,500

10,900

13,600

17,100

21,500

27,300

kW

2.5

3.2

4.0

5.0

6.3

8.0

kW


0.019

0.028

0.030

0.020

0.033

0.050

kW

0.029

0.034

0.035

0.020

0.039

0.060

Triple Outdoor Units

Heating


18, 20, 22, 24, 26, 28, 30, 32 HP

Casing

m3/min

Airflow rate (H/L)

7.5/4.5
265/159

cfm

dB(A)

Sound level (H/L)

mm

Dimensions (H×W×D)

8.5/5.5
300/194

12/9
424/318

Standard accessory


Liquid (Flare)

RX(Y)Q8TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q12TY1(E)

11.0

6.4

11.0

11.0

14.0

Casing

2000.049
mm
kW
RX(Y)Q18TNY1(E)
RX(Y)Q20TNY1(E)
kW
0.049

14.0

6.4


6.4

22, 24 HP
25.0

FXLQ

FXNQ

RX(Y)Q38THY1(E)

RX(Y)Q24TNY1(E)
RX(Y)Q30TNY1(E)
0.049
0.090
0.090
0.110
0.110
* Home Leave Operation function must be set using the remote controller
32˚C for cooling operation and 10 to 30˚C for heating operation.

RX(Y)Q26TNY1(E)

RX(Y)Q32TNY1(E)

Piping
connections Gas (Flare)
Drain

kcal/h

Btu/h

Sound level *1

Liquid

Piping
connections Gas
Drain
Air filter

19,300

24,100

38,700

48,200

47,800

76,400

95,500

154,000

191,000

14.0


22.4

28.0

45.0

13,800

21,500

27,100

43,000

54,600

85,300

107,500

171,000

16.0

25.0

31.5

50.0


0.59

1.41

1.68

3.97

0.59

1.41

1.68

kW
kW
kW

42, 44, 46, 48, 50 HP

Casing colour

Machine weight

RX(Y)Q36THY1(E)
RX(Y)Q40THY1(E)

12,000


mm

kg

25.0

19.0

19.0

mm

6.4

12.7

6.4

12.7

30.0

23.0

26, 28,
30.030, 32 HP
36.0

6.4 receiver wire
Signal

Length = 1,900 mm
12.7

23.0

Chamber

6.4

12.7Signal
receiver

36.0

27.0

27.0

6.4Air suction
grille*

12.7
AIR

9.5

15.9 parts
* Locally obtained

transmitted to the signal receiver.




Standard accessory*
56.0

54,200
215,000
2.62

3.97

63.0

5.02
5.02

2.62

Standard accessory*

Ivory white (5Y7.5/1)

1,670×750×510 1,670×950×510 1,670×1,170×510 1,900×1,170×720

1,900×1,470×720

kg

115


140

165

225

270

295

dB(A)

52

55

59

64

61

67

mm
mm

12.7 (Brazing)


9.5 (Brazing)
15.9 (Brazing)

19.1 (Brazing)

22.2 (Brazing)

15.9 (Brazing)

28.6 (Brazing)

28.6 (Brazing)

Standard
accessory*

Rp1 (PS 1B internal thread)

mm

Long-life filter (anti-mould resin net)

Type

RX(Y)Q42THY1(E)
RX(Y)Q48THY1(E)
kW
1.5
1.5 accessory3.7
3.7

*0.75
Remote
controllers
other than the standard
wireless remote controller
cannot 5.5
be used.
Motor output
RX(Y)Q44THY1(E)
RX(Y)Q50THY1(E)
m3/min
43
69
Airflow rate
RX(Y)Q46THY1(E)
cfm
1,518
2,436

86

134

165

172

Stylish flat panel harmonises with your interior décor
Fan


External static pressure *2

150

Pa

210

Drive system

3,036

4,730

5,825

6,072

270

380

125

480

Belt drive system

Titanium apatite is a photocatalytic material with
Wall Mounted indoor units

achievearequiet
sound
Notes: Specifications
based on
the following conditions;

: Indoor
temp. of 27°CDB, 19°CWB, and outdoor
of 35°CDB.
Triple Outdoor
Units
hightemp.
adsorption
power. Titanium apatite also
levels of 22
dB (A) during•Cooling
cooling
operation.

34, 36 HP

•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

effectively
adsorbs
and
decomposes
bacteria
of indoor unit is only
for44

reference.
capacity of indoor
unit46,
is based
on
the
total capacity
index.
(H/L/SL)
42,
HP Actual
48,
50,
52,
54, 56,
58,
60 HP
38, 40   •Capacity
HP
(See Engineering Data Book for details.)
across
its
entire
surface.
The
photocatalyst
is
*1
Sound
level

:
measured
when
the
air
discharge
outlet
duct
(2
m)
is
attached
(anechoic
chamber
conversion
value).
FTK(X)S20/25 FTK(X)S35 FTK(X)S50 FTK(X)S60 FTK(X)S71
It increases by approximately 5 dB(A) when the plenum
chamber is
installed toby
deliver
direct airflow. to light.
activated
simply
exposure
*2 The value is the external static pressure with standard pulley.

37/25/22 dB (A) 39/26/23 dB (A) 43/34/31 dB (A) 45/36/33 dB (A) 46/37/34 dB (A)

Intelligent Eye with its infrared sensor

automatically controls air conditioner operation
according to human movement in a room. When
there is no movement, it adjusts the temperature
by 2˚C for energy savings.
RX(Y)Q42TNY1(E)
RX(Y)Q38TNY1(E)
RX(Y)Q34TNY1(E)
RX(Y)Q36TNY1(E)

RX(Y)Q46TNY1(E)
RX(Y)Q48TNY1(E)
RX(Y)Q50TNY1(E)
RX(Y)Q52TNY1(E)
Titanium Apatite

RX(Y)Q44TNY1(E)

RX(Y)Q40TNY1(E)

when white
going (5Y7.5/1)/FXNQ:
to sleep or leaving Galvanised
the house, and
after
waking up or returning
FXLQ: Ivory
steel
plate

21O.D.Notes:

1. To prevent an increase in operation noise, avoid
Option
installing the air suction grille directly below the
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5
m, Level difference: 0 m.
suction chamber.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m,
Level difference: 0 m.
2. Grilles, piping connections, ducts, and installation
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total parts
capacity
index.
should
be obtained locally. Slim Ceiling
(See Engineering Data Book for details.)
Mounted Duct type models do not have drain-up
RX(Y)Q22TSY1(E)
RX(Y)Q18TY1(E)
RX(Y)Q26TSY1(E)
• Sound level: (FXAQ-P) Anechoic chamber conversion value, measured
at a(KDGF19A45)
point
1 m in front of
the unit RX(Y)Q30TSY1(E)
and 1 m downward.
Suction grille
pumps.
(FXLQ-MA, FXNQ-MA)
Anechoic chamber conversion value, measured
at a point

1.5signal
m in RX(Y)Q32TSY1(E)
front
of the
atbe
a height
1.5 the
m.
RX(Y)Q24TSY1(E)
RX(Y)Q20TY1(E)
RX(Y)Q28TSY1(E)
3. The
receiver
unitunit
must
locatedofnear
During actual operation, these values are normally somewhat higher as a result ofairambient
suction conditions.
inlet, because the unit includes a
sensor that detects room temperature.
Signals from the wireless remote controller are

134335

FTKS50B

Dimensions (H×W×D)

9.5


RX(Y)Q22TNY1(E)
* Home
Leave0.090
Operation can be
selected forRX(Y)Q28TNY1(E)
any
temperature from
18 to
0.049
0.090
0.110
0.110

240 mm

Liquid (Flare)

36, 40 HP

14.0

6.4

kW

FTKS50F / FTKS60F / FTKS71F
Cooling
Power consumption
FTXS50F / FTXS60F / FTXS71F
Heating


controller cannot be used.

FDKS25EA FDKS35EA FDKS25CA
FDKS35CA
m3/min
7/6
7/6
8/6
11/8.5
14/11
16/12
FDXS25C FDXS35C
cfm
247/212
247/212
282/212
388/300
494/388
565/424
Suspension
bolt*
Suction
duct*
Air
discharge
duct*
Dimensions (H x W x D) 200 x 700 x 620 mm 200 x 900 x 620 mm
Air filter
Space

Saving Type
35/32
35/32
35/32
38/33
39/34
40/35
Sound level (H/L) 220 V dB(A)
Air discharge grille*
25 kg
Weight
21 kg
FXLQ
600×1,000×222
600×1,000×222
600×1,140×222
600×1,140×222
600×1,420×222
600×1,420×222
Dimensions
3
3
3
Airflow rate
(H)
8.7 m /min
Single
Outdoor
Units
9.5

m /min 10Outdoor
m /min
Double
Units AIR
mm
(H×W×D)
610×930×220
610×930×220 610×1,070×220
610×1,070×220 610×1,350×220 610×1,350×220
30 Pa FXNQ
40
Pa
External static pressure
Machine weight

Cooling Only
Heat Pump

3-phase 4-wire system, 380–415 V, 50 Hz

kcal/h

home.

Airflow
rate (H/L)
CDXS25EA
CDXS35EA

18, 20 HP


Cooling Only

FXVQ125MY1 FXVQ200MY1 FXVQ250MY1 FXVQ400MY1 FXVQ500MY1 FXVQ500MY16

Btu/h

Heating capacity

Slim and smooth design
15.9
suits
your
shallow
ceiling
RX(Y)Q28THY1(E)
6.4

RX(Y)Q20THY1(E)
RX(Y)Q22THY1(E) RX(Y)Q30THY1(E)
RX(Y)Q32THY1(E)
RX(Y)Q24THY1(E)
CDXS-EA
series are
Low operation

Cooling
RX(Y)Q14TY1(E)
Power consumption
RX(Y)Q16TY1(E)

Only 700 mmHeating

Cooling capacity

Note: Remote controllers

Models in the FDKS-EA and
sound level
(H/L/SL)
only 700 mm in width and 21 kg in weight, so are
FDKS25
FDKS35
FDKS50
FDKS60
easily
installed
in limited spaces. JustFloor
200 mm
in
Floor
Standing
Standing
Type
Standard
Type Type/Concealed
C(F)DXS25
C(F)DXS35 FDXS50
FDXS60
height,
all models

can be installed
in roomsOutdoor
with
Double
Units
Single
Outdoor
Units
35/31/29FXLQ32MAVE
dB (A) 35/31/29 dB (A) FXLQ50MAVE
dB (A) 38/34/32 dB (A)
as
little
as
240
mm
depth
between
the
drop
FXLQ20MAVE
FXLQ25MAVE
6, 8, 10, 12 HP
14, 16 HP
22, 24, 26 HP FXLQ40MAVE37/33/31
18, 20 HP
28, 30, 32 HPFXLQ63MAVE
MODEL
FXNQ20MAVE
FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE

ceiling and ceiling slab, making them ideal
for
Home
Leave
Operation
supply
1-phase,
220-240
V/220 V,prevents
50/60 Hz large rises or falls in
even shallowPower
ceilings.
FDKS-EA kcal/h
the indoor3,100
temperature
by continuing
1,900
2,400
3,900
4,800 operation*
6,100while
CDXS-EA Btu/h
FXLQ
Great for Cooling capacity
7,500
9,600
12,300
15,400
19,100 This means
24,200 that

you are sleeping
or out
of your home.
hotel use!
kW
2.2
2.8
3.6
4.5
7.1
an air-conditioned
welcome
awaits5.6when you wake
or
kcal/h
2,200
2,800
3,400
4,300
5,400
6,900
return. It also means that the indoor temperature can
Btu/h
8,500
10,900
13,600
17,100
21,500
27,300
Heating capacity

quickly return
to your favourite
comfort
setting.8.0
kW
2.5
3.2
4.0
5.0
6.3
FXNQ
RX(Y)Q6TY1(E)

Space Saving Type

MODEL

FTKS25D Power
/ FTKS35D
supply
FTXS20D / FTXS25E / FTXS35E

15/12
19/14
other than the standard
accessory wireless
remote
530/424
671/494


Piping
mm
12.7
12.7
12.7
12.7
12.7
connections Gas (Flare)
RX(Y)Q18THY1(E) RX(Y)Q26THY1(E)
RX(Y)Q12THY1(E)
Drain
VP13 (External Dia, 18/Internal
Dia,
13)
RX(Y)Q34THY1(E)

RX(Y)Q14THY1(E)
RX(Y)Q16THY1(E)

Cooling Only
High-COP Type
Heat Pump
Standard Type

35/31
36/31
38/31
39/34
42/37
47/41

290×795×238 290×795×238 290×795×238 290×1,050×238 290×1,050×238 290×1,050×238

kg

Machine weight

8/5
282/177

34, 38 HP

White (3.0Y8.5/0.5)

HP

New Lineup

Outdoor Unit Lineup

VRV IV outdoor unit offers a higher capacity of up to 60 HP, responding to the needs of large-sized building.
MODEL
FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE
The single outdoor
unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing the
Cooling Only
FDKS25EA
/ FDKS35EA
Power
supply
1-phase, 220-240 V/220 V, 50/60 Hz

system flexibility to a new
level.
FDKS25CA / FDKS35CA
kcal/h of 21,900
2,400needs can
3,100
3,900
4,800
6,100
With the outdoor unit capacity increased in increment
HP, customers'
be precisely
met.
FDKS50C
/
FDKS60C
Cooling
capacity
Btu/h
7,500
9,600
12,300
15,400
19,100
24,200
Outdoor units with anti-corrosion specifications (-E type on request) are designed specifically for use in areas which are subject to
Heat Pump CDXS25EA / CDXS35EA
kW
2.2
2.8

3.6
4.5
5.6
7.1
salt damage and atmospheric
pollution.

Mo/C

Specifications
Indoor Unit Lineup

Slim
Ceiling
Mounted
The
outdoor
unit
capacityDuct
is upType
to 60 HP in increment of 2 HP.
Wall
Mounted
Type

Air filter
Catches dust

RX(Y)Q54TNY1(E)
RX(Y)Q56TNY1(E)

RX(Y)Q58TNY1(E)
RX(Y)Q60TNY1(E)

Photocatalytic
Air-purifying Filter

Double Outdoor Units
34, 36, 38, 40 HP
3-D Airflow
combines Vertical
and Horizontal
Auto-Swing to
circulate air to every
part of a room for
uniform cooling of even
large spaces.
RX(Y)Q34TSY1(E)
RX(Y)Q38TSY1(E)
When you are in the room

RX(Y)Q36TSY1(E)
* This functionRX(Y)Q40TSY1(E)
is available for
FTK(X)S50/60/71F.



These filters are not medical devices. Benefits
Triple Outdoor Units
42, 44 HP


When you go out

such as the adsorption
46, 48, 50 and
HP decomposition of
bacteria are only effective for substances that are
collected on and in direct contact with the Titanium
Apatite Photocatalytic Air-Purifying Filter.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation

RX(Y)Q42TSY1(E)
RX(Y)Q44TSY1(E)
A uniform temperature
is achieved throughout
the entire room.

RX(Y)Q46TSY1(E)
RX(Y)Q48TSY1(E)
RX(Y)Q50TSY1(E)

Hotline: 0976 173 173

144436


Indoor Unit

Outdoor
UnitLineup
Lineup
Specifications
Outdoor
Unitsindoor
Residential
Indoor units
Units with
Residential
withconnection
connectiontotoBPBPunits
units

Cooling Only / Heat Pump
Lineup
WallCeiling
Mounted
Type
Slim
Mounted
Duct Type

FDXS25C
/ FDXS35C
Dimensions (HXWXD)
FDXS50C
/ FDXS60C
Machine
weight


High-COP Type

Piping
connections Gas (Flare)
Drain

mm

6.4

9.5

Triple Outdoor Units

Heat insulation

Model

18, 20, 22, 24, 26, 28, 30, 32 HP

Colour

Panel
(Option)

9.5

12.7


15.9

I.D ø25XO.D ø32
38pipes
HP
Both liquid 34,
and gas

Standard accessory

BYC125K-W1

5

Note: * For 220 V operation.

Slim
and
smooth design
Ceiling Mounted Cassette (Compact Multi
Flow)
Type
RX(Y)Q18THY1(E) RX(Y)Q26THY1(E)
RX(Y)Q12THY1(E)
suits your
shallow
ceiling
RX(Y)Q34THY1(E)
RX(Y)Q20THY1(E) RX(Y)Q28THY1(E)
RX(Y)Q14THY1(E)

FFQ25BV1B
FFQ35BV1B
FFQ50BV1B
FFQ60BV1B
MODEL
600 x 600

RX(Y)Q38THY1(E)
RX(Y)Q22THY1(E) RX(Y)Q30THY1(E)
RX(Y)Q16THY1(E)
Power supply
1-phase, 220 -240 V, 50 Hz
RX(Y)Q32THY1(E)
RX(Y)Q24THY1(E)
Models in the FDKS-EA and CDXS-EA
series are
Low operation sound level
m3/min (cfm)

Airflow rates (H)

9.0 (318)

10.0 (353)

(H/L/SL)
15.0 (530)

12.0 (424)


only 700 mm in width Sound
and levels
21 kg
in weight,
so are29.5/24.5
dB (A)
(H/L)*
32/25
36/27
41/32
FDKS25
FDKS35
FDKS50
FDKS60
Fan speed
2 steps
easily
installed
in
limited
spaces.
Just
200
mm
in
Standard Type
C(F)DXS25 Microcomputer
C(F)DXS35
FDXS60
control FDXS50

Temperature control
height,
all models
canDimensions
be installed
in rooms
with
Single
Outdoor
Units
(HXWDouble
XD)
286X575X575
mmOutdoor Units
35/31/29 dB (A) 35/31/29
dB (A) 37/33/31 dB (A) 38/34/32 dB (A)
as
little
as
240
mm
depth
between
the
drop
kg
Machine
weight
17.5
6, 8, 10, 12 HP

14, 16 HP
22, 24, 26 HP
18, 20 HP
28, 30, 32 HP
6.4
Liquidthem
(Flare) ideal for
ceiling and ceiling slab,
making
Piping
Gas (Flare)
9.5 Leave Operation prevents large
12.7 rises or falls in
mm
Home
even shallow ceilings.connections
FDKS-EA
Drain
VP20
(External
Dia.
26/Internal
Dia.
20)
the indoor temperature by continuing operation* while
Both liquid and gas pipes
Heat insulation
CDXS-EA
Great for
you are sleepingBYFQ60B8W1

or out of your home. This means that
Model
hotel use!
Panel
White
an air-conditioned welcome
awaits when you wake or
Colour
(Option)
mm
Dimensions (HXWXD)
X700X700
55
return. It also means that the indoor temperature can
kg
Weight
2.7
quickly return to your favourite comfort setting.
Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat
RX(Y)Q6TY1(E)
RX(Y)Q8TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q12TY1(E)

higher owing to ambient conditions.

200 mm
RX(Y)Q18TNY1(E)
RX(Y)Q20TNY1(E)


RX(Y)Q14TY1(E)
RX(Y)Q16TY1(E)
Only 700 mm

Ceiling Mounted
Built-in Type
FDKS25EA FDKS35EA FDKS25CA

RX(Y)Q22TNY1(E)
* Home
Leave Operation can be selected forRX(Y)Q28TNY1(E)
any temperature from 18 to
32˚CRX(Y)Q24TNY1(E)
for cooling operation and 10 to 30˚C for
heating operation.
RX(Y)Q30TNY1(E)
* Home
Leave Operation function must be set using the remote controller
RX(Y)Q26TNY1(E)
RX(Y)Q32TNY1(E)
when going to sleep or leaving the house, and after waking up or returning
home.

FDKS35CA
CDXS25EA CDXS35EA FDXS25C FDXS35C
Air discharge duct* Suspension bolt* Suction duct*
FBQ60BV1
FBQ71BV1
Dimensions (H x W x D) 200 x 700 x 620 MODEL
mm 200 x 900 x 620 mm

Air filter
Space
Saving Type Power
Air discharge grille*
25 kg
Weight
21 kgsupply
1-phase, 220 -240 V, 50 Hz
Airflow
rates (H) 9.5
17.0 (600)
19.0 (670)
m3/min (cfm)
Airflow rate
(H)
8.7
m3/min
Single
Outdoor
Units
m3/min
10Outdoor
m3/min
Double
Units
AIR
Sound
dB
41/35
30 Palevels (H/L)*

40(A)
Pa
External static pressure

18, 20 HP

22, 24 HP

Fan speed

Machine weight

Liquid (Flare)
Piping
connections Gas (Flare)
Drain

mm

Heat insulation

RX(Y)Q18TY1(E)
RX(Y)Q20TY1(E)

Model

Colour
RX(Y)Q22TSY1(E)
Panel
(Option) Dimensions (HXWXD) RX(Y)Q24TSY1(E)

mm
Weight

Signals from the wireless remote controller are
Note: * For 220 V operation.
transmitted to the signal receiver.

134535

Chamber
300X1,000
Signal receiver
wire X800
=
Length 1,900 mm
41
Signal

mm
kg

kg

6.4



Fan speed

FTKS50B

Temperature control

Cooling Only
Heat Pump

36, 40 HP

receiver

AIR

m3/min (cfm)

1-phase, 220 -240 V/220-230 V, 50/60 Hz
9.5 (335)

8.7 (307)

dB (A)

mm
kg

External static pressure

Pa

16.0 (565)

37/33/31

38/34/32
Standard
accessory*

Microcomputer control

200X700X620

25

21

42, 44, 46, 48, 50 HP

Heat insulation

12.0 (424)

5 steps, quiet and automatic

Liquid/ (Flare)
FTKS50F / FTKS60F
FTKS71F
Piping
Gas (Flare)
mm
FTXS50F / connections
FTXS60F
/ FTXS71F
Drain


10.0 (353)

35/31/29

200X900X620

6.4

9.5

200X1,100X620
30

27

12.7

VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes

Standard accessory*

40

30

Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa for F(C)DK(X)S-EA and
40 Pa for FDK(X)S-C(A). Sound level values for bottom-suction operation can be obtained by adding 6 dB (A) for FDKS-EA and 5 dB (A) for
FDKS-C.


Wall Mounted Type
RX(Y)Q36THY1(E)
RX(Y)Q40THY1(E)

Standard
accessory*

Cooling Only
FTKS25DVM FTKS35DVM FTKS50BVMA FTKS50FVM FTKS60FVM FTKS71FVM
MODEL HeatRX(Y)Q42THY1(E)
RX(Y)Q48THY1(E)
* Remote
controllers FTXS35EVMA
other than the standard
wireless remote
controller cannot
be used.
–accessory
Pump
FTXS20DVMA
FTXS25EVMA
FTXS50FVMA
FTXS60FVMA
FTXS71FVMA
RX(Y)Q44THY1(E) RX(Y)Q50THY1(E)
1-phase, 220 - 240 V/220-230 V, 50/60 Hz
Power supply
RX(Y)Q46THY1(E)
White

Front panel colour

Stylish flat panel harmonises with your
interior décor

Airflow rates
(H)

Cooling

Heating*

m3/min (cfm)

Cooling
Sound levels
(A)
units
achieve quietdBsound
(H/L/SL)
Heating*

8.7 (307)

8.9 (314)

9.4 (332)

9.7 (342)


14.7 (519)
16.2 (572)

16.2 (572)
17.4 (614)

17.4 (614)
21.5 (759)

43/34/31
45/36/33
46/37/34
Titanium39/26/23
apatite44/35/32
is a photocatalytic
material
with
Wall Mounted indoor
37/28/25
38/29/26

42/33/30
44/35/32
46/37/34
Triple Outdoor
Units
high
adsorption
power.
Titanium

apatite
also
levels of 22 dB (A) during
cooling operation.
Fan speed
5 steps, quiet and automatic
effectively adsorbs
and
bacteria
control
Microcomputer
control
(H/L/SL)
42,
44 HP
46, 48,
50,decomposes
52, 54, 56, 58,
60 HP
38, 40Temperature
HP
34, 36 HP
Dimensions (HXWXD)
mm
290X1,050X238
283Xacross
800X195 its entire
290surface.
X795X238
The

photocatalyst
is
FTK(X)S60 kg
FTK(X)S71
FTK(X)S20/25 FTK(X)S35 FTK(X)S50
Machine weight
9
12
activated
simply by exposure to light.
Liquid (Flare)
6.4
37/25/22 dB (A) 39/26/23 dB (A) 43/34/31
Piping dB (A) 45/36/33 dB (A) 46/37/34 dB (A)
connections Gas (Flare)

37/25/22

11.4 (402)

mm

9.5

Drain
Intelligent Eye with its infrared
sensor
automatically controlsHeat
air insulation
conditioner operation

Note: * For Heat Pump type only.
according to human movement in a room. When
there is no movement, it adjusts the temperature
forenergy
connection
to residential indoor units RX(Y)Q42TNY1(E)
BP
Units
by 2˚C for
savings.
RX(Y)Q38TNY1(E)
RX(Y)Q34TNY1(E)

RX(Y)Q36TNY1(E)

12.7

15.9

18.0

Both liquid and gas pipes

Air filter
Catches dust

RX(Y)Q46TNY1(E) RX(Y)Q54TNY1(E)
RX(Y)Q48TNY1(E) RX(Y)Q56TNY1(E)
RX(Y)Q58TNY1(E)
RX(Y)Q50TNY1(E)BPMKS967A2

BPMKS967A3
RX(Y)Q60TNY1(E)
RX(Y)Q52TNY1(E)
Titanium Apatite

RX(Y)Q44TNY1(E)

RX(Y)Q40TNY1(E)

MODEL

Power supply

W

1-phase, 220 -240 V/220-230 V, 50/60 Hz
Photocatalytic
3 (connectable to 1-3 indoor units)
2 (connectable to 1-2 indoor units)
Air-purifying Filter
10

A

0.05

X294not
(+356*)
X350
D)

Dimensions (HXWXTriple
mmOutdoor Units
These filters180are
medical
devices. Benefits
Double Outdoor Units

Air suction
grille*
* Locally obtained parts

9.5

Machine weight

Running current

Notes:
15.9
1. To prevent an increase in operation noise, avoid
Option
ø32 the air suction grille directly below the
I.D ø25XO.D
installing
chamber.
Both liquid andsuction
gas pipes
2. Grilles, piping connections, ducts, and installation
BYBS71DJW1
parts should be obtained locally. Slim Ceiling

Mounted Duct type models do not have drain-up
White
RX(Y)Q26TSY1(E)
RX(Y)Q30TSY1(E)
Suction grille (KDGF19A45)
pumps.
55X1,100
X500
RX(Y)Q28TSY1(E)
3. The
signal RX(Y)Q32TSY1(E)
receiver unit must be located near the
4.5 air suction inlet, because the unit includes a
sensor that detects room temperature.

12.7

Cooling Only

Power consumption

Microcomputer control

240 mm

Dimensions (HXWXD)

Sound levels (H/L/SL)*

Number of ports


26,
28, 30, 32 HP
2 steps

Temperature control

Cooling Only FDKS25EAVMB FDKS35EAVMB FDKS25CAVMB FDKS35CAVMB FDKS50CVMB FDKS60CVMB
CDXS25EAVMA CDXS35EAVMA FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA

Airflow rates (H)

Note: Remote controllers
other than the standard
accessory wireless remote
controller cannot be used.

40X950X950

kg

Weight

Space Saving Type

MODEL

Heat Pump
FTKS25D / FTKS35D
Power supply

FTXS20D / FTXS25E / FTXS35E

Dimensions (HXWXD)

White

mm

Dimensions (HXWXD)

Cooling Only
High-COP Type
Heat Pump
Standard Type

230X840X840
24

kg

Liquid (Flare)

Double Outdoor Units
12, 14, 16 HP

mm

HP

New Lineup


Outdoor Unit Lineup

VRV IV outdoor unit offers a higher capacity of up to 60 HP, responding to the needs of large-sized building.
FCQ35BVE
FCQ50BVE
FCQ60BVE
FCQ71BVE
MODEL
The single outdoor
unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing the
Cooling Only
Power supply
FDKS25EA
/
FDKS35EA
1-phase, 220 -240 V/220 V, 50/60 Hz
system flexibility to a new level.
Airflow rates
(H)
m3/min (cfm)
14.0 (494)
15.0 (530)
19.0 (671)
FDKS25CA
/ FDKS35CA
With the outdoor unit capacity increased
in (H/L)*
increment dB
of 2

HP, customers' needs can be precisely met.
(A)
Sound
levels
33/29
35/30
FDKS50C
/
FDKS60C
Outdoor units with anti-corrosionFan
specifications
(-E type on request) are designed specifically2for
use in areas which are subject to
speed
steps
Heat Pump CDXS25EA
/ CDXS35EA
salt damage and atmospheric pollution.
Temperature control
Microcomputer control

Mo/C

Specifications
Indoor Unit Lineup

Slim
Ceiling
Mounted
Duct

The
outdoor
unit
capacity
is upType
to 60 HP in increment of 2 HP.
Ceiling
Mounted
Cassette
Type

kg
8 as the adsorption and decomposition
7.5
Machine When
weightyou go out
in the room
such
of
34,When
36,you
38,are40
HP
42, 44 HP
46, 48, 50 HP
3
for
power
supply
(including

earth
wiring),
2
for
interunit
wiring
(outdoor
unit-BP,that
BP-BP),
Number of wiring connections
bacteria4 for
are
only
effective
for
substances
are
3-D Airflow
interunit wiring (BP-indoor unit)
collected
on
and
in
direct
contact
with
the
Titanium
combines Vertical
Main

mm
9.5X1
Liquid
Piping
Apatite
6.4X3 Photocatalytic Air-Purifying
6.4XFilter.
2
Branch mm
and Horizontal
connections
mm
19.1X1
Main
(Brazing)
Auto-Swing to
Gas
Bacteria
Test
15.9XRemoval
3
15.9X2
Branch mm
circulate air to every Heat insulation
Testing method: dropping method
Both liquid and gas pipes
Result certificate: No. 012553-1 and 012553-2
part of a room for
2.5 kW class to 7.1 kW class residential indoor units
Connectable indoor units

Testing organisation: Japan Spinners Inspecting Foundation
uniform cooling of even
Min. rated capacity of
kW
2.5
connectable indoor units
RX(Y)Q46TSY1(E)
large spaces.
RX(Y)Q42TSY1(E)
RX(Y)Q34TSY1(E)
RX(Y)Q38TSY1(E)

RX(Y)Q44TSY1(E)
RX(Y)Q36TSY1(E)
* This functionRX(Y)Q40TSY1(E)
is available forMax. rated capacity ofA uniform
kWtemperature
connectable indoor units
is achieved throughout
FTK(X)S50/60/71F.



thelength.
entire room.
Note: * Total auxiliary piping

20.8

RX(Y)Q48TSY1(E)

14.2
RX(Y)Q50TSY1(E)

Hotline: 0976 173 173

144636


Indoor Unit
Outdoor
UnitLineup
Lineup
Outdoor
UnitsIndoor Units with connection to BP units
Residential

Cooling Only /Cooling
Heat Pump
Only
Lineup
Wall Mounted Type

VRV IV outdoor unit offers a higher capacity of up to 60 HP, responding to the needs of large-sized building.
The single outdoor
unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing the
Cooling Only
FDKS25EA / FDKS35EA
system flexibility to a new level.
FDKS25CA / FDKS35CA
With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.

FDKS50C / FDKS60C
Outdoor units with anti-corrosion specifications (-E type on request) are designed specifically for use in areas which are subject to
Heat Pump CDXS25EA / CDXS35EA
salt damage and atmospheric pollution.

FDXS25C / FDXS35C
FDXS50C / FDXS60C

Double Outdoor Units
12, 14, 16 HP

Triple Outdoor Units

34, 38 HP

Cooling Only
High-COP Type
Heat Pump
Standard Type
Space Saving Type

FTKS25D / FTKS35D
FTXS20D / FTXS25E / FTXS35E
Cooling Only

Cooling Only
Heat Pump

36, 40 HP


Standard accessory*

FTKS50B

FTKS50F / FTKS60F / FTKS71F
FTXS50F / FTXS60F / FTXS71F

42, 44, 46, 48, 50 HP

RXQ26THY1(E) RXQ28THY1(E) RXQ30THY1(E) RXQ32THY1(E) RXQ34THY1(E) RXQ36THY1(E) RXQ38THY1(E) RXQ40THY1(E)

RXQ6TY1(E) RXQ8TY1(E) RXQ8TY1(E) RXQ6TY1(E) RXQ6TY1(E)

RXQ8TY1(E)







Note: Remote controllers
other than the
standard
RXQ6TY1(E)
RXQ8TY1(E)
accessory wireless remote
controller cannot
be used.
RXQ8TY1(E)

RXQ8TY1(E)

RXQ6TY1(E) RXQ8TY1(E) RXQ8TY1(E) RXQ8TY1(E)

RXQ8TY1(E)

RX(Y)Q18THY1(E)
RX(Y)Q20THY1(E)
RX(Y)Q22THY1(E) RX(Y)Q30THY1(E)
RX(Y)Q32THY1(E)
RX(Y)Q24THY1(E)
CDXS-EA
series are
Low operation

200 mm
RX(Y)Q18TNY1(E)
RX(Y)Q20TNY1(E)

FDKS25EA FDKS35EA FDKS25CA FDKS35CA
CDXS25EA CDXS35EA FDXS25C FDXS35C
Dimensions (H x W x D) 200 x 700 x 620 mm 200 x 900 x 620 mm
Space
Saving Type 21 kg
25 kg
Weight
Airflow rate
(H)
8.7 m3/min
Single

Outdoor
Units
9.5
m3/min 10Outdoor
m3/min
Double
30 Pa
40 Pa
External static pressure

18, 20 HP

22, 24 HP

240 mm

Suspension bolt*

Suction duct*

Air discharge grille*

Units AIR

Signal

Wall Mounted indoor units achieve quiet sound

Triple Outdoor
Units

levels of 22
dB (A) during cooling operation.

34, 36 HP



(H/L/SL)
42,
44 HP

38, 40 HP

FTK(X)S20/25 FTK(X)S35 FTK(X)S50 FTK(X)S60 FTK(X)S71

37/25/22 dB (A) 39/26/23 dB (A) 43/34/31 dB (A) 45/36/33 dB (A) 46/37/34 dB (A)

Titanium apatite is a photocatalytic material with
high adsorption power. Titanium apatite also
effectively adsorbs
and
bacteria
46, 48,
50,decomposes
52, 54, 56, 58,
60 HP
across its entire surface. The photocatalyst is
activated simply by exposure to light.

Intelligent Eye with its infrared sensor

automatically controls air conditioner operation
according to human movement in a room. When
there is no movement, it adjusts the temperature
by 2˚C for energy savings.
RX(Y)Q42TNY1(E)
RX(Y)Q38TNY1(E)
RX(Y)Q34TNY1(E)
RX(Y)Q36TNY1(E)

RX(Y)Q46TNY1(E)
RX(Y)Q48TNY1(E)
RX(Y)Q50TNY1(E)
RX(Y)Q52TNY1(E)
Titanium Apatite

RX(Y)Q44TNY1(E)

RX(Y)Q40TNY1(E)

Air suction
grille*

air suction inlet, because the unit includes a
sensor that detects room temperature.

Air filter
Catches dust

RX(Y)Q54TNY1(E)
RX(Y)Q56TNY1(E)

RX(Y)Q58TNY1(E)
RX(Y)Q60TNY1(E)

Photocatalytic
Air-purifying Filter

34, 36, 38, 40 HP
3-D Airflow
combines Vertical
and Horizontal
Auto-Swing to
circulate air to every
part of a room for
uniform cooling of even
large spaces.
RX(Y)Q34TSY1(E)
RX(Y)Q38TSY1(E)
When you are in the room

Note: 1. Models with (E) feature components treated for heat and rust corrosion resistance, such as external panels,
motor,* Locally
and electric
obtained parts
receiver fan
AIR
component box, in addition to the fins of the heat exchanger. These models are designed specifically
Notes: for use in areas which are
subject to salt damage and atmospheric pollution. Please contact DaikinOption
for more information. 1. To prevent an increase in operation noise, avoid
installing the air suction grille directly below the

2. Specifications are based on the following conditions;
suction chamber.
2. Grilles,
piping connections,
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5
m, Level
difference:ducts,
0 m.and installation
parts should be obtained locally. Slim Ceiling
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit atMounted
a height
of
1.5
m.
Duct type models do not have drain-up
RX(Y)Q22TSY1(E)
RX(Y)Q18TY1(E)
RX(Y)Q26TSY1(E)
Suction higher
grille (KDGF19A45)
During actual operation, these values are normally somewhat
as a result of pumps.
ambientRX(Y)Q30TSY1(E)
conditions.
RX(Y)Q24TSY1(E)
RX(Y)Q20TY1(E)
RX(Y)Q28TSY1(E)
3. The signal RX(Y)Q32TSY1(E)
receiver unit must be located near the
Signals from the wireless remote controller are

transmitted to the signal receiver.

RXQ8TY1(E) RXQ12TY1(E) RXQ12TY1(E)

Stylish flat panel harmonises with your interior décor

Air filter

26, 28, 30, 32 HP
Chamber

RXQ8TY1(E)

RX(Y)Q42THY1(E)* Remote
RX(Y)Q48THY1(E)
controllers other than the standard accessory wireless remote controller cannot be used.
RX(Y)Q44THY1(E) RX(Y)Q50THY1(E)
RX(Y)Q46THY1(E)

Double Outdoor Units

Signal receiver wire
Length = 1,900 mm

RXQ8TY1(E)

RX(Y)Q36THY1(E)
RX(Y)Q40THY1(E)

RX(Y)Q38THY1(E)


RX(Y)Q22TNY1(E)
* Home
Leave Operation can be selected forRX(Y)Q28TNY1(E)
any temperature from 18 to
32˚CRX(Y)Q24TNY1(E)
for cooling operation and 10 to 30˚C for
heating operation.
RX(Y)Q30TNY1(E)
* Home
Leave Operation function must be set using the remote controller
RX(Y)Q26TNY1(E)
RX(Y)Q32TNY1(E)
when going to sleep or leaving the house, and after waking up or returning
home.
Air discharge duct*

RXQ8TY1(E)

RXQ8TY1(E) RXQ10TY1(E) RXQ12TY1(E) RXQ12TY1(E) RXQ14TY1(E) RXQ12TY1(E) RXQ14TY1(E)

Standard
accessory*

Models in the FDKS-EA and
sound level
(H/L/SL)
only 700 mm in width and 21 kg in weight, so are
FDKS25
FDKS35

FDKS50
FDKS60
easily installed
Standard
Type in limited spaces. Just 200 mm in
C(F)DXS25 C(F)DXS35 FDXS50
FDXS60
height,
all models
can be installed
in roomsOutdoor
with
Double
Units
Single
Outdoor
Units
35/31/29 dB (A) 35/31/29 dB (A) 37/33/31 dB (A) 38/34/32 dB (A)
as
little
as
240
mm
depth
between
the
drop
6, 8, 10, 12 HP
14, 16 HP
22, 24, 26 HP

18, 20 HP
28, 30, 32 HP
ceiling and ceiling slab, making them ideal for
Home Leave Operation prevents large rises or falls in
even shallow ceilings.
FDKS-EA
the indoor temperature by continuing operation* while
CDXS-EA
Great for
you are sleeping or out of your home. This means that
hotel use!
an air-conditioned welcome awaits when you wake or
return. It also means that the indoor temperature can
quickly return to your favourite comfort setting.
RX(Y)Q14TY1(E)
RX(Y)Q16TY1(E)
Only 700 mm

RXQ8TY1(E)

Standard accessory*

RXQ10TY1(E) RXQ12TY1(E) RXQ12TY1(E) RXQ12TY1(E) RXQ14TY1(E) RXQ14TY1(E) RXQ14TY1(E) RXQ14TY1(E)

Slim and smooth design
RX(Y)Q26THY1(E)
suits your shallow
ceiling
RX(Y)Q34THY1(E)
RX(Y)Q28THY1(E)


RX(Y)Q12THY1(E)
RX(Y)Q14THY1(E)
RX(Y)Q16THY1(E)

134735

HP

18, RXQ14THY1(E)
20, 22, 24, 26,
28, 30, 32RXQ18THY1(E)
HP
RXQ12THY1(E)
RXQ16THY1(E)
RXQ20THY1(E) RXQ22THY1(E)
StandardRXQ24THY1(E)
accessory
RXQ6TY1(E) RXQ6TY1(E) RXQ8TY1(E) RXQ6TY1(E) RXQ6TY1(E)

RX(Y)Q6TY1(E)
RX(Y)Q8TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q12TY1(E)

New Lineup

Specifications
Indoor Unit Lineup


High-COP Type

Mo/C

Outdoor Unit Lineup

Ceiling
Mounted
TheSlim
outdoor
unit
capacityDuct
is upType
to 60 HP in increment of 2 HP.

RX(Y)Q36TSY1(E)
* This functionRX(Y)Q40TSY1(E)
is available for
FTK(X)S50/60/71F.



These filters are not medical devices. Benefits
Triple Outdoor Units
42, 44 HP

When you go out

such as the adsorption
46, 48, 50 and

HP decomposition of
bacteria are only effective for substances that are
collected on and in direct contact with the Titanium
Apatite Photocatalytic Air-Purifying Filter.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation

RX(Y)Q42TSY1(E)
RX(Y)Q44TSY1(E)
A uniform temperature
is achieved throughout
the entire room.

RX(Y)Q46TSY1(E)
RX(Y)Q48TSY1(E)
RX(Y)Q50TSY1(E)

Hotline: 0976 173 173

144836


×