Tải bản đầy đủ (.pdf) (50 trang)

Thiết bị Pasolink NEO SDH

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (1.19 MB, 50 trang )

ROI-S05748-05GE CONTENTS
February, 2008
CL-1
PASOLINK NEO
6-52 GHz PDH/SDH DIGITAL RADIO SYSTEM
Section I DESCRIPTION
CONTENTS
TITLE PAGE
1 GENERAL DESCRIPTION• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1-1
2 SYSTEM CONFIGURATION AND CHARACTERISTICS • • • 2-1
2.1 System Configuration• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2-1
2.2 Performance Characteristics• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2-19
2.2.1 General System • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2-19
2.2.2 LAN Interface (10/100 Base-T(X))• • • • • • • • • • • • • • • • • • • • • • • • • • • 2-21
2.2.3 LAN Interface (1000Base-SX/LX, 1000Base-T) (GbE)• 2-25
2.2.4 Service Channel (SC)• • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2-26
2.2.5 LCT (PNMT) Interface• • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2-26
2.2.6 PNMS Interface• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • 2-26
2.2.7 RF I/O Port• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • 2-26
2.2.8 Parallel Alarm Interface• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2-27
2.2.9 Wayside • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • 2-27
2.2.10 ODU (Outdoor Unit) and System performance • • • • • • • • • 2-28
2.2.11 IDU (Indoor Unit) and System performance• • • • • • • • • • • • • 2-32
2.3 Interconnection between ODU and IDU • • • • • • • • • • • • • • • • • • 2-36
2.4 Hybrid Combiner/Divider• • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2-37
2.4.1 10 dB Coupler • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • 2-38
2.4.2 OMT (Ortho-Mode Transducer) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2-39
2.5 RF Channel Plan• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • 2-40
2.6 Power Supply• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • 2-41
CONTENTS ROI-S05748
CL-2


2 pages
(This page is intentionally left blank.)
ROI-S05748 GENERAL DESCRIPTION
1-1
1. GENERAL DESCRIPTION
This section provides descriptive information on the PASOLINK NEO
radios which are used for the wide/narrow band point-to-point digital
microwave radio links.
The Indoor Unit (IDU) provides digital PDH (5-48 × E1, 1/2 × E3), SDH
(1 × STM-1) and/or LAN (2P × 10/100BASE-T(X), 4P × 10/100BASE-
T(X) or 1P × (1000BASE-SX/LX or 1000BASE-T)) signal transmission
by the change of the data signal interface card. It can select the modulation
method QPSK/16QAM/32QAM/128QAM, by software selection
depending on the transmission capacity that is configured in the
modulator/demodulator unit.
N ote: For 52 GHz band, only QPSK is available.
The Outdoor Unit (ODU) can be applied for a wide range of RF frequency
bands from 6/7/8/10/11/13/15/18/23/26/32/38/52 GHz.
Applications using the following redundancy configurations, Unprotected
(1+0), 2 × (1+0)*1, Protected (1+1), 2 × (1+1)*1 and 2-WAY*2 are
available for PASOLINK NEO radio systems.
N otes: *1; XPIC
*2; 2-WAY/Cross-connect
Cross Polarization Interference Canceller (XPIC) system is applied for
dual polarized systems using the same frequency in 2 × (1+0) and 2 ×
(1+1) configurations.
GENERAL DESCRIPTION ROI-S05748
1-2
PASOLINK NEO
SELV

!
100M
AUX/ALM
LCT NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLINK NEO
PORT 1 PORT 2
100M
ALM

2M IN/OUT-A
2M IN/OUT-B
PULL
G
G
G
IDU 1+1
SELV
!
100M
AUX/ALM
LCT NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR

ODU
MD/
CBL
PWR
PASOLINK NEO
PORT 1 PORT 2
100M
ALM
2M IN/OUT-A
2M IN/OUT-B
PULL
SELV
!
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PULL
G
G
G

G
IDU 1+0
(Blank)
MDP-150MB-1AA
WEIGHT: 4 kg
SER. No. 123456
INDOOR UNIT
−48 V 2.5A
NEC Corporation

TOKYO JAPAN
MADE IN JAPAN
IDU Package Label
(Example)
IDU Name Plate
N ote *1: When a 2-WAY label is put on the 16E1
IN TFC, the 2-WAY/XC mode is available.
2-WAY
*1
0678
DATE 2007-09 (H2930)
(WITH OPTION)
(WITH ODU & OPTION)
(IDU)
ROI-S05748 GENERAL DESCRIPTION
1-3
TRP-6G-1B
OUTDOOR UNIT
SHIFT FREQ
161MHz

SUB BAND
(NWA-009024)
0.5A
NEC Corporation

MADE IN JAPAN
CAUTION
Non-ionizing
radiation
-48V INPUT
Power down IDU before
disconnection or
connection of cable.
PASOLINK NEO
SERIAL No.
PASOLINK NEO
FG
IFL
MON
RX LEV
ODU NHG Type (For 6-38 GHz Band)
ODU Name Plate
For 52 GHz band, the TRP-52G-5A ODU
(Pasolink Mx) is used for NEO.
(ODU)
0678
(NHG)
TX
LOW
123456

- 48V
WEIGHT
4kg
/
TX FREQ
DATE

A
7725MHz
2007-09
TOKYO JAPAN
TRP-52G-5A
OUTDOOR UNIT
SHIFT FREQ
661MHz
SUB BAND
(H0356B)
0.5A
NEC Corporation

MADE IN JAPAN
CAUTION
Non-ionizing
radiation
-48V INPUT
Power down IDU before
disconnection or
connection of cable.
PASOLINK Mx
SERIAL No.

0678
TX
LOW
123456
- 48V
WEIGHT
4kg
/
TX FREQ
DATE

A
51454MHz
2007-09
TOKYO JAPAN
ODU Package Label
(Example)
-48V
IFL
RX LEV MON
ODU NHG2 Type (For 6/7/8 GHz Band)
ODU NHG2 Type (For 13-38 GHz Band)
ODU Mx Type (For 52 GHz Band)
TRP-13G-5B
OUTDOOR UNIT
SHIFT FREQ
266MHz
SUB BAND
(NWA-034278)
0.5A

NEC Corporation

MADE IN JAPAN
CAUTION
Non-ionizing
radiation
PASOLINK NEO
SERIAL No.
0678
(NHG2)
TX
LOW
123456
- 48V
WEIGHT
3kg
/
DATE

A
2008-01
TOKYO JAPAN
ODU NHG Type
ODU NHG2 Type
CAUTION
HOT SURFACE
Avoid contact.
TRP-13G-5B (NHG2)
266MHz
TRP-13G-5B SERIAL No.123456(NWA-034278-010-001)

NWA-34278-010-001
TRP-13G-5B
GENERAL DESCRIPTION ROI-S05748
1-4
4 pages
(This page is intentionally left blank.)
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-1
2. SYSTEM CONFIGURATION AND
CHARACTERISTICS
This section provides outline of the system configuration, system
performance, RF channel plan, external alarm items and House keeping
input/output, and power supply.
2.1 System Configuration
The system consists of the MDP-150MB-1AA Modulator-Demodulator
(Indoor Unit (IDU)) and TRP-(*1)G-1B/5B Transmitter-Receiver (Outdoor
Unit (ODU)), Hybrid Combiner/Devider*2 or Orthogonal Mode
Transducer (OMT)*3 and the antenna.
The TRP-( )G-1B (NHG Type) or TRP-( )G-5B (NHG2 Type) is available
with frequency bands of 6 GHz to 38 GHz. band and the TRP-52G-5A is
for 52 GHz.
N otes: *1:ODU Type depends on the frequency band used, such as
TRP-(13)G-1B (N HG Type) or TRP-(13)G-5B (N HG2 Type)
is applied for 13 GHz band.
*2:The Combiner/Divider is used in (1+1) single antenna
configuration for antenna direct mount type ODUs.
*3:The OMT is used in XPIC systems with antenna direct
mounting ODUs.
*4:The IDU CTRL F/W Ver3.4.xx or later version is required
when the TRP-( )G-5B ODU N HG2 Type is connected with

the N EO IDU. (Refer to 1.1 Accessing the PASOLIN K N EO
in Section IV Appendix LCT Operation.)
Refer to
Fig. 2-1 Protected/Unprotected System Configuration (1/3)
Fig. 2-2 Signal Interface/Capacity (1/2)
Fig. 2-3 IDU e/w Standard and Optional Interface (1/3)
Fig. 2-4 Configuration of the ODU (1/4)
Fig. 2-6 System Block Diagram (1/5)
Fig. 2-7 Hybrid
Fig. 2-8 10 dB Coupler
Fig. 2-9 OMT Transducer
Fig. 2-10 Power Supply System Block Diagram (1/3)
Table 2-1 System General Performance (1/2)
Table 2-2 2 Port LAN 150 Mbps (128QAM)
Table 2-17 System Performance for 128QAM/ODU
Table 2-18 System Performance for IDU
Table 2-19 Alarm & House Keeping Output Items
Table 2-20 House keeping input Items
Table 2-22 Characteristics
Table 2-23 Characteristics
Table 2-24 Characteristics
Table 2-25 RF Frequencies
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-2
Fig. 2-1 Protected/Unprotected System Configuration (1/3)
ODU
IDU
DATA
IN/OUT
1+0 IDU

IF Cable
ODU
IDU
DATA
IN/OUT
1+0 IDU
IF Cable
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
ODU
IDU
DATA
IN/OUT
1+0 IDU
IF Cable
ODU
IDU
DATA
IN/OUT
1+0 IDU
IF Cable
f1

f1’
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
f1
f1’
f1
f1’
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
ODU (Working)
No.1
DATA
IN/OUT
ODU (Standby)

1+1 IDU
IF Cable
IF Cable
No.2
f1’
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
f1
f1’
RF Cable
No.2
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
RF Cable
No.2
ODU (Working)

No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
f1’
ODU (Working)
No.1
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
IF Cable
No.2
f1
f1
f1
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Working)
1+1 IDU
IF Cable
IF Cable

No.2
ODU (Working)
HYB
No.1
DATA
IN/OUT
ODU (Working)
1+1 IDU
IF Cable
IF Cable
No.2
f1
f1’
f2
f2’
RF Cable
RF Cable
1+0 with Waveguide/Coaxial Cable Connection
1+0 with Antenna Direct Connection
1+1HS/HS with Coaxial Cable Connection
1+1 HS/HS with Antenna Direct Connection
1+1 HS/Hybrid SD with Antenna Direct Connection
1+1 HS SD with Antenna Direct Connection
1+1 Twin-path FD with Antenna Direct Connection
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-3
Fig. 2-1 Protected/Unprotected System Configuration (2/3)
ODU (Working)
IDU
DATA1

IN/OUT
ODU (Working)
IDU
DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
H(V)
ODU (Working)
OMT
IDU
DATA1
IN/OUT
ODU (Working)
IDU
DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)

H (V)
ODU (Working)
OMT
IDU
DATA1
IN/OUT
ODU (Working)
IDU
DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
ODU (Working)
HYB
No.1
DATA1
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
No.2
ODU (Working)
HYB
No.1

DATA2
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
No.2
IDU
X IF Cable
IDU XPIC
CTRL
Cable
No. 1
No. 2
No. 1
No. 2
H (V)
V (H)
V (H)
H (V)
ODU (Working)
OMT
IDU
DATA1
IN/OUT
ODU (Working)
IDU
DATA2
IN/OUT
IDU
X IF Cable

1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
ODU (Working)
OMT
IDU
DATA1
IN/OUT
ODU (Working)
IDU
DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
RF Cable
ODU (Working)
IDU
DATA1
IN/OUT
ODU (Working)
IDU

DATA2
IN/OUT
IDU
X IF Cable
1+0 IDU
IF Cable
IF Cable
1+0 IDU
V (H)
H (V)
RF Cable
2(1+0) XPIC with Antenna Direct Connection
2(1+0) XPIC with Waveguide/Coaxial Cable Connection
2(1+0) XPIC with Waveguide/Coaxial Cable Connection
2(1+1) XPIC with Waveguide/Coaxial Cable Connection
ODU (Working)
HYB
No.1
DATA1
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
No.2
ODU (Working)
HYB
No.1
DATA2
IN/OUT
ODU (Standby)

1+1 IDU
IF Cable
No.2
IDU
X IF Cable
IDU XPIC
CTRL
Cable
No. 1
No. 2
No. 1
No. 2
H (V)
V (H)
V (H)
H (V)
IDU XPIC
CTRL
Cable
IDU XPIC
CTRL
Cable
IDU XPIC
CTRL
Cable
IDU XPIC
CTRL
Cable
IDU XPIC
CTRL

Cable
IDU XPIC
CTRL
Cable
f1
f1
f1’
f1’
f1
f1
f1’
f1’
f1
f1
f1’
f1’
f1
f1
f1’
f1’
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-4
Fig. 2-1 Protected/Unprotected System Configuration (3/3)
IF
Cable
ODU
IDU
E1/LAN
DATA
IN/OUT

IDU
2-WAY/Cross-conect (XC) Configuration
ODU
MODEM (No.1)
16E1 INTFC
2-WAY/XC PKG
(e/w LAN)
MODEM (No.2)
E1/LAN
DATA
IN/OUT
IF
Cable
ODU
IF
Cable
IF
Cable
ODU
IDU
E1/LAN
DATA
IN/OUT
DIR-A
DIR-B
Tributary
(2-WAY/XC System)
For the details description, refer to APPENDIX 2-WAY/XC Application and Setting.
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-5

Fig. 2-2 Signal Interface/Capacity (1/2)
ODU
IDU
16E1 (0 to 16 × 2 MB G.703 + 80 to 8 MB 10/100 Base T(x)
IEEE 802.3)
MAIN DATA INTFC (Selectable)
48E1 (5/10/20/40/48 × 2 MB) G.703
STM-1 (155 MB ELE) G.703
16E1 (5/10/16 × 2 MB) G.703
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
SC (2 × 64 KB V.11 + 2 × 9.6 KB RS-232C) +
EOW (1)
1000 Base T/SX IEEE 802.3z
6 to 52 GHz
128QAM
QPSK/16/32/128QAM
E3 (1/2 × 34 MB + 4/8× 2 MB) G.703
QPSK/16QAM/32QAM
ALM/HK/SC (AUX) INTFC
6 ALM OUT (4 HK OUT/4 Cluster OUT)
QPSK/16/32/128QAM
6 HK IN/4 Cluster IN
QPSK/16/32/128QAM
10/100 Base T(X) 2-Port LAN IEEE802.3
WS (1 × 2 MB) + 64/128/192/256 KB SC- LAN
128QAM
WS/LAN INTFC (Additional)
STM-1 (155 MB OPT) ITU-T G.957, S-1.1/L-1.1
128QAM
MAIN DATA INTFC (for APS)

QPSK/16QAM
1+0/1+1 Configuration
32QAM
10/100 Base T(X) 4-Port LAN (100 MB) IEEE802.3 +
4E1 (4 × 2 MB) G.703
10/100 Base T(x) 4-Port LAN IEEE802.3 + 8E1 (8 × 2 MB)
32E1 (0 to 32 × 2 MB G.703 +100 to 16 MB 10/100 Base T(x)
IEEE 802.3)
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-6
Fig. 2-2 Signal Interface/Capacity (2/2)
ODU
ODU
6 to 52 GHz
OMT
STM-1 (155 MB ELE) G.703
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
SC (2 × 64 KB V.11 + 2 × 9.6 KB RS-232C) +
EOW (1 )
1000 Base T/SX IEEE 802.3z
128QAM
ALM/HK/SC(AUX)
6 ALM OUT (4 HK OUT/4 Cluster OUT)
6 HK IN/4 Cluster IN
10/100 Base T(X) 2-Port LAN IEEE 802.3
WS (1 × 2 MB) + 64/128/192/256 KB SC- LAN
WS/SC-LAN INTFC (Additional)
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
MAIN DATA INTFC (for APS)
MAIN DATA INTFC (Selectable)

STM-1 (155 MB ELE) G.703
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
SC (2 × 64 KB V.11 + 2 × 64 KB RS-232C) +
EOW (1)
1000 Base T/SX IEEE 802.3z
128QAM
ALM/HK/SC(AUX)
6 ALM OUT (4 HK OUT/4 Cluster OUT)
6 HK IN/4 Cluster IN
10/100 Base T(X) 2-Port LAN
WS (1 × 2 MB) + 64/128/192/256 KB SC- LAN
WS/SC-LAN INTFC (Additional)
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
MAIN DATA INTFC (for APS)
MAIN DATA INTFC (Selectable)
No.2
No.1
IDU
IDU
XPIC Configuration
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-7
Fig. 2-3 IDU e/w Standard and Optional Interface (1/3)
Unprotected System (IDU)
SELV
!
STM-1 IN
STM-1 OUT
AUX/ALM
NMS

NE
ALM
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
SELV
!
100M
AUX/ALM
LCT NMS

NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLINK NEO
PORT 1 PORT 2
100M
ALM
2M IN/OUT-A
2M IN/OUT-B
SELV
!

AUX/ALM
NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLI NK NE O
ALM
2M IN/OUT-C
LCT
LCT
SELV

!
AUX/ALM
NMS
NE
ALM
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLINK NEO
LCT
2M IN/OUT-A
2M IN/OUT-B

STM-1 IN
STM-1 OUT
PULL
PULL
PULL
Equipped with STM-1 Electrical Interface
Equipped with STM-1 Optical Interface for APS
Equipped with 16E1 Interface with 2 Port LAN Interface
Equipped with 48E1 Interface
SELV
!
STM-1 IN
STM-1 OUT
AUX/ALM
NMS
NE
ALM
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX

RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK N EO
LCT
Equipped with STM-1 Electrical Interface in XPIC
SELV
!
STM-1 IN
STM-1 OUT
AUX/ALM
NMS
NE
ALM
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT

IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLI NK NE O
LCT
ALM
STM-1 IN
STM-1 OUT
(Blank)
(Blank)
(Blank)
(Blank)
(Blank)
(Blank)
(Blank)
(Blank)
SELV
!
AUX/ALM
NMS
NE

SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
Equipped with DC-DC CONV
SELV
PWR
PULL
PWR
ALM

FUSE (250V/8AH)

43V
G
OUT
ONLINE
ONLINE
(Blank)
G
G
G
G
G
G
G
G
G
G
G
G
G
G
STD
G
G
G
G
G
G
G

G
SELV
!
AUX/ALM
NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLI NK NE O
ALM
LCT

PULL
Equipped with E3 Interface
(Blank)
G
G
G
100M
PORT 1 PORT 2
100M
WS IN/OUT
IN
OUT
E3 CH1
IN
OUT
E3 CH2
STM-1 IN
STM-1 OUT
ALM
(Blank)
SELV
!
100M
AUX/ALM
LCT NMS
NE
SC IN/OUT
EOW
PROTECT
CALL

MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLINK NEO
PORT 1 PORT 2
100M
ALM
2M IN/OUT-A
2M IN/OUT-B
PULL
Equipped with 32E1 Interface with 2 Port LAN Interface
(Blank)
G
G
G
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748

2-8
Fig. 2-3 IDU e/w Standard and Optional Interface (2/3)
Protected System (IDU)
SELV
!
STM-1 IN
STM-1 OUT
AUX/ALM
NMS
NE
ALM
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/

CBL
PULL
PWR
PASOLINK NEO
SELV
!
100M
AUX/ALM
LCT NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL

PWR
PASOLINK NEO
PORT 1 PORT 2
100M
ALM
2M IN/OUT-A
2M IN/OUT-B
SELV
!
AUX/ALM
NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU

MD/
CBL
PWR
PASOLINK NEO
ALM
2M IN/OUT-C
LCT
LCT
SELV
!
AUX/ALM
NMS
NE
ALM
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC

PWR
ODU
MD/
CBL
PWR
PASOLINK NEO
LCT
2M IN/OUT-A
2M IN/OUT-B
STM-1 OUT
STM-1 IN
PULL
PULL
PULL
Equipped with STM-1 Electrical Interface
Equipped with STM-1 Optical Interface in APS
Equipped with 16E1 Interface with 2 Port LAN Interface
Equipped with 48E1 Interface
SELV
!
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU

MD/
CBL
PWR
PULL
SELV
!
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PULL
SELV
!
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC

PWR
ODU
MD/
CBL
PWR
PULL
SELV
!
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PULL
SELV
!
STM-1 IN
STM-1 OUT
AUX/ALM
NMS
NE
ALM

SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
Equipped with STM-1 Electrical Interface in XPIC
SELV
!
XIF IN
XIF OUT
IF IN/OUT

TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PULL
SELV
!
STM-1 IN
STM-1 OUT
AUX/ALM
NMS
NE
ALM
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT

TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLINK NEO
LCT
SELV
!
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PULL
ALM

STM-1 OUT
STM-1 IN
(Blank)
(Blank)
(Blank)
ONLINE ONLINE
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G

SELV
!
AUX/ALM
NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLINK NEO
ALM
LCT
PULL

Equipped with E3 Interface
G
G
G
100M
PORT 1 PORT 2
100M
WS IN/OUT
IN
OUT
E3 CH1
IN
OUT
E3 CH2
SELV
!
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PULL

G
SELV
!
100M
AUX/ALM
LCT NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLINK N EO
PORT 1 PORT 2

100M
ALM
2M IN/OUT-A
2M IN/OUT-B
PULL
Equipped with 32E1 Interface with 2 Port LAN Interface
SELV
!
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PULL
G
G
G
G
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-9
Fig. 2-3 IDU e/w Standard and Optional Interface (3/3)
SELV

!
AUX/ALM
NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PULL
PWR
PASOLI NK NE O
LCT
SELV
!

AUX/ALM
NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLINK NEO
LCT
PULL
Equipped with STM-1 Optical Interface with LAN/WS Interface (SDH)
Equipped with GbE Interface with LAN/WS Interface (SDH)
G

G
G
G
G
G
ALM
WS IN/OUT
100M
PORT 1 PORT 2
100M
WS
ALM
STM-1 OUT
STM-1 IN
ONLINE
ALM
WS IN/OUT
100M
PORT 1 PORT 2
100M
WS
ALM
OUT
1000BASE-SX/LX
PORT
IN
(Blank)
(Blank)
SELV
!

AUX/ALM
NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLINK NEO
ALM
LCT
PULL
Equipped with 4P LAN Interface (PDH)
(Blank)

G
G
G
100M
PORT 3 PORT4
100M
2M IN/OUT
100M
PORT 1 PORT 2
100M
SELV
!
100M
AUX/ALM
LCT NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET

XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PASOLINK NEO
PORT 1 PORT 2
100M
ALM
2M IN/OUT-A
2M IN/OUT-B
PULL
SELV
!
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/
CBL
PWR
PULL

G
G
G
G
Equipped with 16E1 Interface with 2 Port LAN for 2-WAY/XC (PDH)
2-WAY
SELV
!
AUX/ALM
NMS
NE
SC IN/OUT
EOW
PROTECT
CALL
MMC
MAINT
MEMORY
IDU
XIF IN
XIF OUT
IF IN/OUT
TX
RX
RESET
XPIC CTRL
XPIC
PWR
ODU
MD/

CBL
PULL
PWR
PASOLINK NEO
LCT
Equipped with LAN/WS Interface for Main LAN (SDH)
G
G
ALM
WS IN/OUT
100M
PORT 1 PORT 2
100M
WS
(Blank)
M S
.
G
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-10
Fig. 2-4 Configuration of the ODU (1/4)
Waveguide Connection (1+0)
(11-38 GHz NHG)
ODU
Coaxial Cable Connection 6/7/8GHz (1+0)
ODU


Antenna
Antenna Direct Mounting (1+0)

(11-52 GHz NHG)
ODU
Antenna Direct Mounting (1+0)
(13-38 GHz NHG2)
ODU
Waveguide Connection (1+0)
(13-38 GHz NHG2)
ODU
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-11
Fig. 2-5 Configuration of the ODU (2/4)
Antenna Direct Mounting 2(1+0)
(ODU NHG Type)
ODU
OMT
Coaxial Cable Connection 6/7/8GHz 2(1+0)
(ODU NHG or NHG2 Type)
ODU
OMT
Dual Pol. Antenna
Dual Pol. Antenna
Dual Pol. Antenna
Antenna Direct Mounting 2(1+0)
(ODU NHG2 Type)
OMT
Waveguide Connection 2(1+0)
(ODU
ODU
Dual Pol. Antenna
Dual Pol. Antenna

ODU
Waveguide Connection 2(1+0)
(ODU NHG2 Type)
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-12
Fig. 2-5 Configuration of the ODU (3/4)
Waveguide Connection (1+1 SD)
ODU
ODU
Antenna Direct Mounting (1+1)
(ODU NHG Type)
ODU
HYB
Coaxial Cable Connection 6/7/8 GHz (1+1)
ODU
HYB
Antenna Direct Mounting (1+1)
(ODU NHG2 Type)
ROI-S05748 SYSTEM CONFIGURATION AND CHARACTERISTICS
2-13
Fig. 2-5 Configuration of the ODU (4/4)
Waveguide Connection 2(1+1) XPIC
(ODU NHG Type)
ODU
ODU
ODU
ODU
Dual Pol. Antenna
Dual Pol. Antenna
(REG)

(PROT)
Waveguide Connection 2(1+1) XPIC
(ODU NHG2 Type)
Dual Pol. Antenna
ODU
Dual Pol. Antenna
ODU
SYSTEM CONFIGURATION AND CHARACTERISTICS ROI-S05748
2-14
Fig. 2-6 System Block Diagram (1/5)
IN/OUT
( )INTFC *
CTRL
NMS
LCT
EOW
MODEM
DC-DC
CONV
RF
PS
CKT
SYNTH
(LO)
CTRL
IDU
ODU
48E1/
1/2E3
ALM IN/OUT

BPF
(TX)
BPF
(RX)
ODU
INTFC
ODU
INTFC
DPU/
FEC
SC IN/OUT
NE
IN/OUT
STM-1 (ELE)/
( )INTFC *1
CTRL
NMS
LCT
EOW
MODEM
DC-DC
CONV
LAN/WS INTFC *3
WS/SC-LAN
RF
PS
CKT
SYNTH
(LO)
CTRL

IDU
ODU
ALM IN/OUT
STM-1 (OPT)/
BPF
(TX)
BPF
(RX)
ODU
INTFC
ODU
INTFC
DPU/
FEC
SC IN/OUT
NE
128QAM
MODEM
1+0 CONFIGURATION FOR PDH
STM-1 (OPT)
1+0 CONFIGURATION FOR SDH
2-PORT LAN/WS
f
H(L)
f
L(H)
f
H(L)
f
L(H)

6 to 52 GHz
6 to 52 GHz
QPSK/
16QAM/
32QAM/
MODEM
16E1+2PORT LAN/
GbE
EOW
(JACK)
EOW
(JACK)
EOW
(JACK)
LPF/EQL
LPF/EQL
PS IN
PS IN
N ote: * Optional
N otes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals
( )INTFC *2
32E1+2PORT LAN/

Tài liệu bạn tìm kiếm đã sẵn sàng tải về

Tải bản đầy đủ ngay
×