Tải bản đầy đủ (.pdf) (2 trang)

Tài liệu ADC KRONE - Datasheet - Cat 6A - Termination Modules ppt

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (198.24 KB, 2 trang )


Page 1 of 2
adckrone.com/au z
TrueNet
®
Termination Modules




Issue 3





O r d e r i n g I n f o r m a t i o n
Description Part Number
BMF, 12 Way Kit, CopperTen™ 6450 1 107-00

Product Description and Application
Supplied as kit consisting of: a 12 way mounting frame and 12 CopperTen 20 Pair modules with rear
cable management.
The CopperTen module provides a 20 pair high-density, high performance, cost competitive 10G Base-T
channel compliant module, to accept ADC KRONE’s CopperTen cable.

Module General Specifications and Features

The upper and lower shell are moulded in PBT.
The internal shielding is manufactured from tin plated mild steel.
Modules are terminated with the standard ADC KRONE termination tools 6089 2 003-00 or


6417 2 055-01, and may also be terminated with a 110 tool.



Technical Specifications
Environment for use: ................................................ Indoors or in dry enclosure rated IP54 or greater
Operating temperature range:.................................................................................. -40°C to +80°C
Maximum relative humidity:...........................................................................

93% non-condensing
Wire range for solid & stranded copper conductors: ....................................0.4-0.65mm (26-22 AWG)*

* A maximum of 2 equal, solid conductors only, of up to 0.5 conductor diameter can be terminated per
slot. Only 1 conductor of stranded wires per slot can be terminated. If any conductors >0.5 have been
terminated, reversal to smaller conductors in no longer possible.

Wire insulation diameter range (PE, PVC): ...........................................................Typically 0.7-1.4mm

Number of wire reterminations:......................................................................................... Up to 200
Wire insertion force (0.5 conductor diameter): .............................................................................. 6N
Wire pull out force, radial (0.5 conductor diameter): ...................................................................... 5N
Wire pull out force, axial (0.5 conductor diameter): ..................................................................... 35N
Number of patching cycles, Modules: ................................................................................. Up to 750
Patch plugs:.........................................................................Up to 200
Transmission & reliability:……………………………………. Meets & exceeds the requirements of TIA/EIA-TSB-155
Draft 1 when used with KRONE CopperTen cable.

Change of contact interface resistance after reliability testing...................................................< 5mΩ



Typical to ISO/IEC 11801 and TIA/EIA 568B per through connection. ie. 2 insulation displacement
and 1 disconnection contact joint.

Voltage/current rating at 25°C ambient:.........................................................

150V AC at 2.5A max.
Dielectric strength: ........................................................................................................

1.5kV AC
1800 801 298 z


Page 2 of 2
6450 1 107-00 Issue 3
Surge voltage strength (1.2/50 µsec wave shape): .................................................................

2.5kV
Surge current strength (8/20 µsec wave shape): Modules: ........................................................

3kA
Patch plugs:.......................................................................................................................

0.5kA
Insulation resistance:..................................................................................

5x10 M
Ω
at 500 VDC
Flammability rating of plastic housing: ................................................................................ UL 94 V0




×