TECHNICAL DATA
Application The KRONE S-STP 450/AWG23 cable is designed for applications up to 450
MHz and provides transmission performance meeting Category 6 specifications.
This cables are low skew products, i.e. the difference in propagation delay
between the individual pairs is very low.
This is increasingly being requested for Gigabit Ethernet. The suitability of the
cable for high-bit-rate transmission systems ensures a high degree of future
proofing. Additional features are the slim design and low weight of the cables.
Each pair is individually shielded (STP). The twisted pairs are additionally
enclosed as a group in a braided shield (S-STP) to provide superior shielding
performance.
The cable thus exceeds the requirements for EN 55022 Class B emission and EN
55024 immunity, enabling networks to be built which are compliant with the
standards on electromagnetic compatibility.
Characteristics The KRONE S-STP 450/AWG23 cables are available in halogenfree versions
with FRNC outer jacket. Every single pair is shielded with foil (STP). Each pair is
individually shielded (STP). The twisted pairs are additionally enclosed as
a group in a braided shield (S-STP) to provide superior shielding performance.
This cables are low skew products, i.e. the difference in propagation delay
between the individual pairs is very low.
The slim and lightweight design allowed best characteristics in fire retardance.
The compact design allows the cables to be installed flat or folded together.
Print example (single cable): “KRONE PREMISNET CAT6 S-STP LSZH FR 4P
AWG23 SBC ISO/IEC 11801/ EN50173-1 IEC 60332-3 CAT C“ <Woche/Jahr>


CA KRONE 7053326255 <METERMARKER> + <Charge>
Duplex cable: same as single cable except for part number.
Cat.6 Installation Cable
- S-STP 450/AWG23, FRNC
- Duplex S-STP 450/AWG23, FRNC
Copper Conductor AWG 23
Foam/Skin-PE-insulation
Twisted pair
Braided shield
Sheath zero halogen, flame
retardant
Foil shield
4 twisted pairs
S–STP 450/AWG23 4P
KRONE GmbH
Beeskowdamm 3-11 09/2003_Subject to changes! Seite 2 von 2
14167 Berlin
Tel.: + 49 30 84 53 1
Fax: + 49 30 84 53
2
3
TECHNICAL DATA
Cat.6 Installation Cable
- S-STP 450/AWG23, FRNC
- Duplex S-STP 450/AWG23 FRNC
Design
Type designation Category Diameter
conductor
Number
of pairs

Fire rating
(MJ/m)
Halogen-
free
Tensile
strength for
installation [N]
Outside-
? [mm]
Weight
[kg/km]
S-STP 450 / 23 4P
LS0H-3 6 AWG 23 4 0,57 Yes 145 7,4 58
Electrical Characteristics at 20°
Frequency in MHz 1 10 16 20 31,25 62,5 100 250 450
Attenuation in dB/ 100 m per Standard * 2,1 6,0 7,6 8,5 10,8 15,1 19,9 33,0 -
Typical data dB / 100 m 1,8 5,3 6,8 7,6 9,6 13,6 18,0 28,5 40,5
Near-end crosstalk loss in dB per Standard * 66,0 59,3 56,2 54,8 51,9 47,4 44,3 38,3 -
Typical data dB / 100 m 100,0 100,0 100,0 100,0 100,0 96,0 93,0 87,0 82,0
PSNEXT in dB/ 100 m per Standard * 64,0 57,3 54,2 52,8 49,9 45,4 42,3 36,3 -
Typical data dB / 100 m 98,0 98,0 98,0 98,0 98,0 94,0 93,0 88,0 83,0
ELFEXT in dB/ 100 m per Standard * 66,0 50,0 45,9 44,0 40,1 34,1 30,0 22,0 -
Typical data dB / 100 m 93,0 93,0 93,0 93,0 90,0 86,0 83,0 70,0 54,0
PSELFEXT in dB/ 100 m per Standard * 64,0 47,0 43,0 41,0 37,1 31,1 27,0 19,0 -
Typical data dB / 100 m 91,0 91,0 91,0 91,0 88,0 84,0 81,0 68,0 52,0
ACR in dB 98,2 94,7 93,2 92,4 90,4 82,4 75,0 58,5 41,5
*) Standard: Requirements on 100 m installed Category 6 cable for Class E cabling links (corresponds to pr EN 50288-5-1
June 2001)
Max. loop resistance: 146 Ohm/km
Max. resistance difference: 1%

Insulation resistance: > 5000 MOhm x km
Impedance Zo at 0,064 MHz: 125 Ohm ??20%
Impedance Zo at 1 - 100 MHz: 100 Ohm ??15%
Impedance Zo at 101 - 250 MHz: 100 Ohm ??18%
Transfer impedance: < 10 mOhm per meter bei 10 MHz
Longitudinal conversion loss dB/ref. Length = 1000 m: > 46 dB bei 64 kHz
Longitudinal conversion loss dB/ref. Length = 100 m: > 40 dB bei 1 MHz
Longitudinal conversion loss dB/ref. Length = 100 m: > 20 dB bei 100 MHz
Mutual capacity: 43 pF/m
Max. capacitance at 0,001 MHz: 1000 pF/km
Propagation velocity > 10 MHz (NVP*c): 0,79 c
Propagation delay ??10 MHz: 4,2 ns/m
Skew: 4 ns/100m
Mechanical Wire insulation: Zero halogen foam-skin material
Characteristics Sheath material: FRNC
Deployment area: Dry and damp rooms
Max. temperature range during installation: 0°C up to +50 °C
Max. operating temperature: -20 up to +60°C
Min. bend radius for single flexure: 40 mm (over flat side)
Min. bend radius during installation or pulling: 60 mm (over flat side)
Ordering Information Type designation: Cat.6 Installation Cable
Delivery: 1000 m on one way drum
500 m on one way drum (Duplex)
Ordering number 4 pairs: 7053 3 262-55
7053 3 762-54 (Duplex)

×