TECHNICAL SPECIFICATION
LOOSE TUBE / SINGLE JACKET
NON-ARMOR / JELLY FILLED CABLE
KRONE RESERVE THE RIGHT TO MAKE CHANGE TO THIS DOCUMENT WITHOUT PRIOR NOTICE
RELEASE: 2.0
PAGE 2 OF 7
1.

SCOPE
1.1 Application
This specification covers the general requirements for fiber optic telecommunication
cables used for inter-building backbone in duct installation and lashed aerial use.
1.2 Cable Description
1) Single Jacket/Non Armor
Single and 50 or 62.5 Multi mode color coded fibers, jelly filled color coded loose
tubes, PE filler (if required), SZ-stranded around the dielectric central strength
member, jelly filled, plastic tape, dielectric strength member and outer PE jacket
2.

OPTICAL FIBER
1) Manufacturing process: MCVD
2) Fiber type: Matched clad fiber
The optical, geometrical and mechanical performance of the optical fiber shall be in
accordance with Table 1 and 2 below.
Table 1. The Optical, Geometrical and Mechanical Performance of the Multi Mode Fiber
SPECIFICATION
ITEMS UNITS
50 Multi Mode 62.5 Multi Mode
Attenuation DB/km
3.5 at 850nm
1.0 at 1300nm


3.5 at 850nm
1.0 at 1300nm
Bandwidth MHz.km
400 at 850nm
600 at 1300nm
200 at 850nm
500 at 1300nm
Numerical Aperture -
0.200.015 0.2750.015
Core Diameter

503.0 62.53.0
Core Non-circularity %
6.0 6.0
Cladding Diameter

1252.0 1252.0
Cladding Non-circularity %
2.0 2.0
Core/Cladding Concentricity Error

3.0 3.0
Coating Diameter

24515 24515
Proof Test Kpsi
100 100
*Note) Superior performance available upon request.
KRONE RESERVE THE RIGHT TO MAKE CHANGE TO THIS DOCUMENT WITHOUT PRIOR NOTICE
RELEASE: 2.0

PAGE 3 OF 7
Table 2. The Optical, Geometrical and Mechanical Performance of the Single Mode Fiber
ITEMS UNITS SPECIFICATION
Attenuation dB/km
0.4 at 1310nm
0.25 at 1550nm
Chromatic Dispersion Ps/nm.km
3.2 at 1285nm ~ 1330nm
18 at 1550nm
Zero Dispersion Wavelength nm 1300 ~ 1324
Zero Dispersion Slope Ps/nm
2
.km
0.093
Cut-off Wavelength
(cc, 22m of a cabled fiber)
nm
1270
Mode Field Diameter

9.31.0%
Mode Field Concentricity

0.8
Cladding Diameter

1251.0
Cladding Non-circularity %
1.0
Coating Diameter


24515
Proof Test kpsi
100
*Note) Superior performance available upon request.
3.

CABLE CONSTRUCTION
The construction of the cable shall be in accordance with Table 3 below.
Table 3. Construction of the Cable
ITEMS DESCRIPTION
Number of Fibers 2 ~ 72
Type of Fiber 62.5 Multi Mode, 50 Multi Mode and Single Mode
No. of Fibers per Tube Max. 12
Material PBT (Polybutylene Terephthalate)
Loose Buffer
Tube
Diameter Nom. 2.4 mm
Filling Compound
in Loose Buffer Tube
Thixotropic Jelly Compound
Filling Compound
between Loose Buffer Tubes
Polybuthane Type Jelly Compound
Central Strength Member FRP (Fiberglass Reinforced Plastic)
Core Wrapping Tape
Plastic Tape
(To provide heat barrier and good forming of core)
Dielectric Strength Member
Glass yarn

(To provide the required tensile strength together
with the central strength member)
Material Black MDPE
Outer Jacket
Thickness Min. 1.25mm, Nom. 1.8mm
KRONE RESERVE THE RIGHT TO MAKE CHANGE TO THIS DOCUMENT WITHOUT PRIOR NOTICE
RELEASE: 2.0
PAGE 4 OF 7
4.

FIBER AND LOOSE BUFFER TUBE IDENTIFICATION
The color code of the loose buffer tubes and the individual fibers within each loose buffer
tube shall be in accordance with Table 4 below.
Table 4. The Color Code of the Individual Fibers and Loose Tubes
No. of Fibers/
Loose Buffer Tubes
Color
No. of Fibers/
Loose Buffer Tubes
Color
1Blue7Red
2 Orange 8 Black
3 Green 9 Yellow
4 Brown 10 Violet
5Gray11Pink
6 White 12 Aqua
5.

PHYSICAL / MECHANICAL / ENVIRONMENTAL
PERFORMANCE

The mechanical and environmental performance of the cable shall be in accordance with
Table 5 below. Unless otherwise specified, all attenuation measurements required in this
section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi
mode fiber (MM).
Table 5. The Mechanical and Environmental Performance of the Cable
ITEMS
TEST METHOD AND
ACCEPTANCE CRITERIA
Tensile Loading
And Bending Test
# Test method: TIA/EIA-455-33A
Mandrel diameter: 30D (D = cable diameter)
Short term tensile load: 2,700N for 1 hour
Long term tensile load: 1,000N for 10 minutes
# Acceptance Criteria
Fiber strain: Less than 60% of the fiber proof strain
for short term tensile load
Attenuation increment: 0.10 dB (SM)
0.20 dB (MM)
for long term tensile load
Compressive Loading
Resistance Test
# Test method: TIA/EIA-455-41A
Applied load: 110 N/cm
Duration of loading: 10 minutes
# Acceptance Criteria
Attenuation Increment: 0.10 dB (SM)
0.20 dB (MM)
KRONE RESERVE THE RIGHT TO MAKE CHANGE TO THIS DOCUMENT WITHOUT PRIOR NOTICE
RELEASE: 2.0

PAGE 5 OF 7
Table 5. The Mechanical and Environmental Performance of the Cable (continued)
ITEMS
TEST METHOD AND
ACCEPTANCE CRITERIA
Repeated Impact Test
# Test method: TIA/EIA-455-25B
Height of impact: 150mm
Drop hammer mass: 2.0kg
No. of impact cycles: 25 cycles
# Acceptance Criteria
Attenuation Increment: 0.10 dB (SM)
0.20 dB (MM)
No jacket cracking and fiber breakage
Cyclic Flexing Test
# Test method: TIA/EIA-455-104A
Sheave diameter: 20D (D = cable diameter)
No. of flexing cycles: 25 cycles
Flexing speed: 30 cycles/minute
# Acceptance Criteria
Attenuation Increment: 0.10 dB (SM)
0.20 dB (MM)
No jacket cracking and fiber breakage
Cable Twist Test
# Test method: TIA/EIA-455-85A
Cable length twisted: 2m
No. of twist cycles: 10 cycles
Twist angle: 180
# Acceptance Criteria
Attenuation Increment: 0.10 dB (SM)

0.20 dB (MM)
No jacket cracking and fiber breakage
Temperature Cycling Test
# Test method: TIA/EIA-455-3A
Temperature cycling schedule
: 23-3065-306523
Soak time at each temperature: 8hours
# Acceptance Criteria
Attenuation increment: 0.15 dB/km (SM)
0.20 dB/km (MM)
Water Penetration Test
# Test method: TIA/EIA-455-82B
Length of specimen: 3m
Height of pressure head: 1m
Test time: 24 hours
# Acceptance Criteria
No leakage through the open cable end

KRONE RESERVE THE RIGHT TO MAKE CHANGE TO THIS DOCUMENT WITHOUT PRIOR NOTICE
RELEASE: 2.0
PAGE 6 OF 7
6.

PACKING AND MARKING
6.1 Cable Marking
The sheath shall be marked at intervals of one meter with following information.
1) Cable type and fiber counts
2) Name of the manufacturer
3) Year of manufacture
4) Length marking

6.2 Cable Packing
6.2.1 Standard length of cable shall be 2km and 4km. Other cable length is also available if
required by customer.
6.2.2 Each length of the cable shall be wound on a separate wooden reel.
6.2.3 Both ends of the cable shall be sealed with a suitable plastic cap to prevent the entry of
moisture during shipping, handling and storage.
6.2.4 Wood-fiber board or circumference battens shall be laid on cable between flanges and
fixed by steel bands.
6.2.5 The cable ends shall be securely fastened to the reel to prevent the cable from becoming
loose in transit or during placing operations.
6.3 Cable Reel
6.3.1 Details given below shall be distinctly marked on a weather proof materials on both
outer sides of the reel flange:
(1) Length of cable in meters
(2) Cable type and fiber counts
(3) Gross weight in kilograms
(4) Reel number
(5) Name of the manufacturer
(6) Year of manufacture
(7) Arrow showing the direction the drum shall be rolled
6.3.2 The cable shall be wound on the reel designed to prevent damages during shipment and
installation.
6.3.3 The arbor hole on each flange shall be lined with a metal plate.
KRONE RESERVE THE RIGHT TO MAKE CHANGE TO THIS DOCUMENT WITHOUT PRIOR NOTICE
RELEASE: 2.0
PAGE 7 OF 7
< Cross-section Drawing of Cable >
12-Fiber Cable
1.


Diameter, Weight and Minimum Bending Radius
Minimum Bending Radius (mm)
No. of Fibers
Nominal
Cable Diameter
(mm)
Approx.
Cable Weight
(kg/km)
Under Load No Load
2 ~ 72 12.5 125 250 125
*) Actual values for cable weight and diameter may deviate from the calculated values given
in the table above.
== End of Specification ==
Optical Fibers
Jelly Compound
Loose Buffer Tube
Filler(if necessary)
Jelly Compound
Dielectric CSM
Core Wrapping Plastic Tape
Dielectric Strength Member
Outer PE Jacket

×