Tải bản đầy đủ (.pdf) (16 trang)

Tài liệu ELECTRICAL /DATA CABLING WORKS IN THE BRANCH OF BANK OF INDIA, BHULLAR , LUDHIANA. doc

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (88.04 KB, 16 trang )

BANK OF INDIA, ZONAL OFFICE, LUDHIANA ZONE
1st Floor, Surya Kiran Complex
Phase-II, The Mall,
Near Rakh Bagh
Ludhiana – 141 001
Ph : 0161-2410775
Fax: 0161-2408161

Date: 28.12.2012


TENDER

ELECTRICAL & DATA CABLING


OF

ELECTRICAL /DATA CABLING WORKS IN THE
BRANCH OF BANK OF INDIA, BHULLAR ,
LUDHIANA.


To








Sub : TENDER FOR ELECTRICAL FURNISHING WORKS FOR
BANK OF INDIA, BRANCH BHULLAR, LUDHIANA .



Dear Sir,

1. The sealed tenders are invited from approved contractors for the above said work
on behalf of Zonal Manager, Bank of India, Zonal office Ludhiana upto
14.01.2013 on or before 3.00 P.M The schedule, specification & terms and
conditions for the above said work is enclosed.

2. The sealed cover containing the schedules and the tender in original along with
earnest money for Rs. 10,000/= in shape of demand draft in favour of Bank of
India, shall be submitted in the office of Zonal Manager, Zonal office, Ludhiana.
The cover shall superscribe as follows:

TENDER FOR ELECTRICAL WORKS IN B.O.I. BRANCH BHULLAR , LUDHIANA.


3. The validity of the offer is to be kept valid up to four months from the date of
opening of the tenders.

4. The time completion of work shall be essence of the contract, and shall be
completed within 60 days only from the date of award of work

5. Offers not contained on the tender documents of Bank & not accompanied with
the requisite sum of earnest money & in the form mentioned in the tender, notice,
will not be accepted.


6. Telegraphic / conditional tender will not be entertained.

7. The rates quoted by the tender should be inclusive of sale tax & all other levies, if
any.

8. All the valid tenders duly received by the stipulated time will be opened on the
same date i.e. on 14.01.2013 in the Zonal office of the Bank at 4.00 P.M,
Tenderers are at liberty to be present.

9. The contract is entitled to ask for one running payment upto 50% of the total
work done during the currency of work, but an advance intimation of 10 days
shall have to be given to Bank, so as to facilitate in preparation / security &
release of payments. The balance payment will be released after successful &
satisfactory completion of work.

10. Deduction of income tax at source on application as per provision of the section
194 of the Income Tax Act 1961 will be made from the payments to be made to
the contractor.
11. Any Deviation with respect to Time or specification, Bank without prejudice has
right to-
a) Cancel / Rescind/ Revoke the order,
b) Impose penalty upto 20% of the total value of job.

12. Contractor in their own interest, are advised to visit the site and get themselves
familiarize in the prevailing situation before submitting their rates. No claim what
so ever for ignorance, misunderstanding shall be entertained later.

13. The work is proposed to be done in the working branch, hence contractor has to
plan his work so as to General working of the branch is not affected. He may have
to work only after business hours & during the nights.


14. The ZM, Zonal Office, B.O.I. Ludhiana reserves the rights to increase or decrease
the under job covered by the present state of the contract.

15. The contractor shall be responsible for making good in expeditions & work man
like manner any defects which may be found with in One Year of the handing over
of the premises or premises put to beneficial use. In case contractor fails to do so,
the same would be get done at his cost & risk. The cost incurred by the Bank shall
be deducted from the retention money or any other dues.

16. Security deposit equivalent to 10% from each running bill shall be deducted &
shall be returned only after expiry of defects liability period. & Retanir money 10%
after 12 months.

17. The schedule of quantities is only approximate & all the work executed shall be
paid for in accordance with the actual measurements.

18. The samples of all the material & work times shall be got approved from the
Architects M/S HERZI SINGH & ASSOCIATES, Plot No.2772, Near Grewal Hospital,
Gurdev Nagar, and
Bank of India, Zonal office, Rakh Bagh, Ludhiana.

Mob: 098146-15066 Ph. 0161-242262



19. Any damage done to the property of the Bank during execution of work
shall be responsibility of the contractor & it shall be made good by him, at his cost
to the entire satisfaction of Architect/ Bank.


20. The drawings contain sketches showing salient features details at the various
scale indicating extent of work & specifications to be followed. These can be
modified by the Bank / Architect from time to time in accordance with technical
requirements at the site.

21. The work shall be of the highest standard both as regard to material &
workmanship. Modern tools & first-class latest techniques shall be employed for
its execution.

22. The contractor shall examine all drawings before quoting & commencing of actual
work & report to the Architect / Bank any discrepancy or omission &
shortcomings in the drawings.

23. The Architect shall have full powers to get the material or workmanship etc.,
inspected & tested by an independent agency for its soundness & adequacy at the
cost of contractor.

24. The contractor shall employ adequate Labour to complete the work within the
selected time. No claim for the Labour shall be entertained. The contractor shall
also make his own proper arrangement for welfare, housing & safety of his own
material & Labour.

25. The contractor shall examine all drawings before connecting the actual work &
report to the Architect/ Bank any discrepancies or omission & shortcomings in the
drawings or when they conflict with other works, or with each other.

26. The prospective contractor, on intimation of acceptance of tender must submit a
progress network of the complete work based on bar chart with in four days as
much or modified with the consent of the contractor, shall form part of the
agreement.


27. The contractor shall visit the site of the work & shall satisfy himself as to the
conditions under which the work is to be performed. He shall also check &
ascertain the location of any existing structure or equivalent or another which may
affect the work. No claim, made in ignorance or misunderstanding of site
conditions or a ground of insufficient description shall be entertained.

28. The contractor shall get the approval of the Architect regarding the route of
conduits, No. of runs, diameter of conduits, No. & size of wires, location of pull
boxes, route of cables No. & size of wires, location of pull boxes, route of cables in
ground/ wall for electrical / telephone works covered herein.

29. The contractor / his supervisor will be bound to sign the site order book & to carry
out the instructions given therein.

30. Bad workmanship is liable to be rejected.
31. All materials to be arranged by the contractor for use in the work shall be of
approved make & shall be as per relevant Indian Standard Specification. Where it
is mandatory to use I. S. Marked materials, the contractor shall arrange the same
accordingly.

32. The contractor shall make his own arrangement at his own cost for all general &
special electrical tools & plants required for electrical work. Entire safety
precautions during installation shall be taken as per relevant I. S., I.E. Tulles &
CPWD specifications.

33. Adopter boxes, wherever used, shall be not less than 16 SWG M .S. Sheet.
34. All repairs & patchwork, if any, shall be neatly carried out to match the original
finish & to the entire satisfaction of the Architect. Any damages to the building
due to execution of work shall have to be made good immediately by the

contractor at his own cost.

35. The telephone conduits & fire alarm conduits shall be laid with G.I. fish wires kept
pulled in for pulling of at least 1000mm extra at ends.

36. Main junction box for telephone conduit system shall be mounted at a height so
that the top of box does not exceed 1.65 meters from the floor level & in a
suitable location for working by the staff.

37. Sockets, base, boxes, conduits, cable glands, ducts & all other materials not
included elsewhere but required for the work shall be provided by the contractor.

38. The contractor shall obtain & pay for all permits, licenses & certificates for
approval required by all relevant authorities & organizations. All work of the
contractor shall confirm to the requirements of local codes.


39. The work shall be carried out as per regulations & in best workmanship like
manner by licensed persons. The means of licensed persons working in the
installation shall be furnished to the Architect prior to the commencement of the
work.

40. It will be the contractor’s responsibility to get the electrical installation works
inspected by the local statutory Authorities. Fire officer and such other officials.
Extra payments / claims are allowable

41. Sub - Distribution boards shall be equipped with miniature circuit breaker.
Miniature circuit breakers shall have adequately sized terminals for the out going
leads. rated chase & neutral bus bars of high conductivity electrolytic Aluminum
with Adequately sized terminals or clamps for the incoming conductor.


42. It is brought to the attention of the conductor that: -

a) All electrical portable tools should be either 240 volts double insulated or
50 volts via Transformer

b) The contractor has to supply all necessary ladders / steps which must be in
good safe condition.

c) Entire safety precautions during installations shall be taken as per relevant I.S.
I.E. Rules & C.P.W.D. specifications.

43. All electrical works shall be carried out along with the progress of Interior works.
Any debris due to electrical works shall be removed & the Contractor shall clear
the site as soon as the work is completed on his cost.

44. Non flammable insulating barriers shall be provided between poles & phases & all
live protected with non-flammable insulating shields to prevent accidental contact
while replacing or operating the miniature circuit breakers.

45. The contractor is supposed to get the samples approved from the Architect, whose
decision shall be binding on the contractor, The condition is also applicable for my
material not mentioned in the specifications or schedule of work. No deviations
are allowed in these even during /after Tender.


46. The Drawing will collect Form:
ARCHITECTS:-
M/S HERZI SINGH & ASSOCIATES
Plot No. 2772, Gurdev Nagar,

Near Grewal Hospital,
Ludhiana.
Ph. 0161-2422625
Mob: 098146-15066
E-mail:
(Blue Print set available 500/- per set)
And
Bank of India
Zonal Manager
Regional Office, Ludhiana.

47. Any clarification regarding drawing Please Contact:
ARCHITECTS :
M/S HERZI SINGH & ASSOCIATES
Plot No. 2772, Gurdev Nagar,
Near Grewal Hospital,
Ludhiana.
Ph. 0161-2422625
Mob: 098146-15066
E-mail:-




Signature of Contractor Signature of Architect Signature of A.G.M.









LIST OF APPROVED MATIRIALS & MANUFACTURERS
Description Brand
1) Board /Ply : Duro / Green (MR Grade)
2) Laminate : Decolam /Green/Sunduce/Century
3) Door closer / floor spring : Everite, Godrej.
4) Drawer & Keyboard : Ebco, & Good Quality
slide rails
5) Glue for fixing commercial
board / laminate Fevicol (Pidilite)
6) Glass : Modi float/ St. Gobain
7) Mortice latch & lock : Godrej
8) Vertical blinds : Vista levelor, Mac, Dack.
(Vertical/ Horizontal)
9) Pre-laminated board : Nova pan, Deco board, Green
10) Aluminum section : Jindal/Hindalco
11) Vinyl flooring 2mm th. : Bhor (Marblex) spartek, premier
12) Paints : ICI/Asian/Nerolac, Berger
13) M.C.B’s & DB’S : Siemens, Havell’s / L&T, Anchor
14) Wood preservative : Bison by British Paints/ Term seal by PCI.
15) Plug & Socket (Metal) : MDS, Crompton, Anchor, Roma, Havell’s
16) Switch & Socket : Anchor, Rome, Havell’s.
17) Pipe (PVC) Conduit : Diplast, Avon, (ISI Mark)
(2 mm Thk)
18) Telephone cable : Havell’s
19) Wires : Havell’s, Finolex
20) Cables : Havell’s, Finolex
21) Fans : Crompton, Usha, Havell’s

22) Textured paint : Spectrum, Heritage
23) Carpet : Modi, Transasia
24) Mirror optics Fixtures : Philips, Crompton, Havell’s
25) Spot light & light fittings : Philips, Havell’s, Crompton
26) Aluminum Cladding : Eurobond / Alston
27) DB’S : Havells / Roma
28) MCB and MCB Boxes : Siemens / Havell’s / Anchor / L&T
29) Night Latch : Godrej
30) Key Boards Drawer : EBCO 450 MM Length With Mouse Paid.
31) Telescopic CPU Stand : Godrej / Marblex
32) Vitrified Tiles : Nitco, Kajaria, Euro, Asian (filling should be
with Grought)
33) Cement : Ambuja, ACC, L&T
34) Teak wood : Only Seasoned Timber to be used.
35) For wooden molding : 1
st
Quality either Ghana Teak wood or C.P.
wood as specification in detail specification
of each item.


1. Commercial Block Board ( 19 mm thick) : IS –1659 : 1990
2. Teak Ply 4/6 mm Thick : IS –1328 : 1982
3. 6/12 mm thick Commercial Ply : IS – 303 : 1989
4. Flush Door : IS –2202 (Part –1)1991



Note: -
Other Materials if required to be used, shall be got approved before

execution.

































PRICE BID

ELECTRICAL / DATA CABLING WORKS IN THE
BRANCH OF BANK OF INDIA, BHULLAR,
LUDHIANA.


SUMMARY OF COST


A. ELECTERCAL WORK Rs. _______________


TOTAL Rs. _______________


(Rs._______________________________________________)





SIGNATURE OF THE CONTRACTOR
WITH SEAL












BRAND IMAGE
Refurnishing Standardisation-2007
Guidelines for uniform furnishing Pattern
In Branch / Office Premises

i) Guideline for General Layout
The consultants appointed for any refurbishing project as per prevailing laid down
guidelines will prepare the layout plan of the branch premises in consultation with
corporate services/ A&S Dep’t besides the Information Technology Department and
Security Department of Zonal Office and Branch Manager as per the requirement of
the Branch.

a) Diamond Customer Lounge / Relationship Manager :
In the branches having more than 500 Diamond Customers, a Diamond Customer
Lounge (DC Lounge) along with Relationship Manager (RM) is required to be
provided. It is preferable to have the DC Lounge along with RM’S Cabin adjacent
Branch Manager’s Cabin. The modules having indicative sizes of the Diamond
Customer Lounge along with Relationship Manager’s Cabin and Branch Manager’s
Cabin and Diamond Customer Lounge along with RM’s Cabin are shown in the
drawings for your guidance.

The entry to the RM’s cabin shall be through DC Lounge and if Manager’s cabin is

adjoining to the DC Lounge, one entry to DC Lounge from the Manager’s cabin shall
also be provided.

Maximum area to be earmarked for the Branch Manager/ Relationship Manager
and Diamond Customer’s Lounge shall be 150 sq.ft,75sq.ft. respectively.

b) Suitable space shall be earmarked for customers for seating (Max.area – 200sq.ft.
and Max. number of seating – 20 No ) if it is not possible to have seating
arrangement at one location, if may be suitably scattered.

c) Provision for drinking water (Water dispenser) may be provided in the customer
area.

d) Demarcation on the floor (Preferably in yellow colour ) say 3’ from the cash counters
shall be drawn for restricting customers from crowding in front of the cash counters.
Also stainless steel chain link in between two cash counters may be provided in the
customers area.

e) All statutory Notices / instructions are to be displayed on a single board which shall
be placed at a prominent location in the customer area. The background of Board
shall be blue (matching with blue colour laminate No.1 )with white letters.

f) Provision for an officer for authorization purpose should be kept near cash counters.

g) Lunch Room for Staff : Lunch room may be earmarked for staff with the seating for
maximum 20% of staff strength of the Branch depending upon the availability of
space in the branch.

h) In CBS Branches, no serve room is required. As the web-server is being provided in
Manager’s Cabin therefore the router may be provided at suitable location in

Manager’s cabin in consultation with Zonal IT Dep’t and data cables may be covered
with wooden boxing finished with laminate No.3 Suitable arrangement for ventilator
( exhaust fan) and also for air-circulation (wall fan) may be provided for avoiding
heating in consultation with Zonal IT Department.

i) The UPS room shall be located in such a way that it has proper ventilation.

j) Preferably the electrical conduits should be concealed so as to have neat and clean
ambience.

k) In the Branches headed by the Deputy General Manager or Asstt. General Manager,
only cubicles shall be provided to the Chief Manager posted in the Branch.


























ELECTRICAL WORKS

S.
No.

Description

Unit

Qty

Rate Amount
1.

Supply and erection, P.
V.C. insulated cable with
copper conductor (unsheathed) left there including
the cost of supply and
Erection of pipe.















1.1

Cable size 1.0 mm sq. copper conductor 1100 volt
grade.
R.
M

12
0


1.2

Cable size 1.5 mm sq. copper I conductor 1
100 volt
grade.

R.
M


10
0


1.3

Cable size 4 mm. sq. copper conductor 1100 volt
grade
R.M

90


1.4

Cable size 6 mm. sq. copper conductor 1100 volt
grade.
R.M

90


1.5

Cable size 2.5 mm. sq. copper conductor 1100 volt
grade.
R.M

120



1.6

Cable Size 25 m
m sq. copper conductor 1100 volt
grade.
R.M

4
0


1.7

Cable Size 35 mm sq. copper conductor 1100 volt
grade.
R.M

4
0


1.8

Leased/ISDN line Cable from Router to Outer Pole of
BSNL
R.M

13
0



2.

ELECTRICAL POINTS

Providing fixing and testing of electrical p
oints
including wiring, plate type switches, sockets and MS
switch boxes with rust proof treatment, switch board
size should
accommodate the required nos. of switches and
sockets etc. where required complete with 1 mm. sq.
multi stand wire for earthing in 25mm. dia
unbreakable P.V.C. conduit of wall thickness, 2.00
mm. ISI marked with special under floor/wall and
above false ceiling and copper conductor wire only
be used of approved make.



2.1

15 Amp wiring in 4 mm sq. multi stand copper wire
and metal clad enclosure, sockets and
plugs.(Includind New A.T.M Cabin).
Each

5



2.2

5 Amp wiring in 25 mm sq. multi stand PVC copper
wire including plate switches, sockets and plugs.
Each

2
5


2.3

5 Amp socket point wiring in 2.5 mm sq. multi std
PVC copper wire incl plate switches sockets and
plugs.
Each

25


3.

UPS POINTS

P/F & testing triple 5 amp point wiring for computers
with 2.5 mm aq. Multi stand copper PVC wire in
unbreakable PVC conduits 25 mm. dia with special
having wall thickness 2 mm incl. MS switches boxes
with rust proof treatment size to accommodate the

reqd no of switches, sockets etc & plate type sockets
with indicators two nos in one plate incl earthing
with 1 5 mm sq multi stand wire in 25 mm dia
unbreakable PVC conduit ISI marked complete in all
respects (2
nd
& 3
rd
point will be extension of 1
st
point
payment will be made for 1
st
point only).
Each

7


4.

WIRING AND FIXING OF TF POINT

Incl providing & fixing of PVC conduit in wall floor incl
ten pair telephone cable, MS box and two pin
telephone sockets on plate out let incl testing &
commissioning etc as reqd.

Each


4


5

EARTHING




5.1

Supplying and installation of earth stations with 600
mm x 600 mm x 3 mm th copper plate electrode
complete with 25 mm dia “B” class GI pipe for
watering incl funnel 30 cm x 30 cm x 30 cm
masonry chamber with precast RCC cover complete
with salt & charcoal filing (AS per IS 3034-1987) incl
copper strip ¾” wide 3 mm thick (Positioning
discuss with Architect)
Each


2 No



5.2

supplying, installatio

n, effecting proper connection,
testing and commissioning of the following size GI
earth strips/GI/wire as reqd
R.
M


4
5


6.

CEILING LIGHTS

(2’ x 2’)

Supplying fixing & testing of lights Make PHILIPS/
havell’s Model no LHCC 22336127 (Paralite) (Mirrior
Options) (3 x 36 FP-LCrompton) Ref Cat No.FBS
200/236 P5 HF (electronic bellatt) with 2nos PLL
36W Lamps incl. extension of 2x1.5mm PVC copper
wire in PVC conduit from nearest available point.
No
14






7.

DOWN LIGHTS

Supplying fixing testing & commissiong down light
fixtures make CROMPTON GRAVES/PHILIPS (Cat
No.FBH 150/218HF) 2x18 W PLL Model no. LHOC
12218399 (Modular Down Light) ( DL-12) Havell’s
complete with all fittings tubes started and
connection etc incl. extension of 2x1.5mm PVC
copper wire in PVC conduit from nearest available
point.
No
7












8.
Providing & laying unbreakable PVC conduit 25 mm
dia of wall thickness 2 mm for data cable from
server to place of work complete in all respects.


R.M

75






9.

Supplying fixing testing and

commissioning of 16”
dia oscillating wall fans with regulator make USHA,

Each


10




CROMPTON
/
GREAVES complete.



10.

Phase changer with indicator 63 amp as approved
make specified.

Each



1No



11.

P&F of exhaust fan 12” crompton Grea
ves /Usha
with all fittings incl wiring & switches complete in all
respects.

Each

1 No




12.

P&F of 2 X 28 wall tube lights complete set with

choke,fatti and starter of Phillips, Crompton,
Wipro (36 Watt)

Each

4 No



13
.

LT Panel :
-

Design , S
upply, Testing, Installation &
Commissioning of L.T. Panel made out of 16 SWG
(1.6 mm thick) sheet steel, Powder coated/Enamel
Painted. Panel shall be floor mounting type,
complete with inter connection of outgoing Cables.
a) Main controlling TPN main switch 160 MCB
b) Change cover TPN 100 amps switch
c) 63 Amp TPN on load air breaking switch
d) Voltmeter 0 to 500 volt
e) Ampere meter (c.t) 0-100 Amp with TPN
indicators with selector switch
f) 63 Amp. TPN switches








Each










1 No.










1
4.




P&F of 3 nos 200 amp kitkat with 1 no nutel link on
suitable size of wooden plank of thickness not less
than 25 mm complete as secure (Key/Std/Havells
make)

Each

1 No.







15.

P/F Insulation

including Copper pipes 1/2" , 1/4"
& 5/8",1/4"dia, 20 guage with 10mm th.rubber
insulation make Total- line & 2x4mm sq. multi
strand PVC copper cable conductor with earthing
make FINOLEX / HAVELL’S in PVC conduit
(Including new A.T.M)
R.M
80


16.

P/F 20mm i/d heavy PVC make (Supreme /
Finolex) drain pipe in slope,with specials,
concealed in wall / floor incl. chase cutting &
disposal of malba away from site, repair with
cement mortar 1:3. Complete job to the
satisfaction of the Architect/Employer. (Including
new A.T.M)
R.M
100

17.

P/F of 16 SWG

Sheet adopter box also base frame
for fitting of MCB DB System in UPS room.
Each
1

18.

Distrbution Box For U.P.s room input/output with
complete:
1) 20 Amp melt claid box with 32 Amp
S.P.M.C.B=7 Nos

2)
8 Way Distrbution Box M.C.B

4) 4 Way Distrbution Box With 2.No.32 Amp
Lum-
Sum
Lum-
Sum


TOTAL AMOUNT







Signature of contr
actor

(with seal)



SPECIFICATION FOR ELECTRICAL WORKS



WIRE - FINOLEX/HAVELL’S
(PVC COATED COPPER WIRE)
PVC CONDUITS - DIPLAST/ AVON/ ISI Marks (2mm Thikness)
PVC CAPING AND CASING -

MCB AND MCB BOXES - SIEMENS/ HAVELL’S/ ANCHOR/ L&T
5AJ15A SWICH AND SOCKET - ANCHOR/ HAVELL’S / ROMA
DB'S - HAVELL’S / ROMA
CABLES - HAVELL’S /FINOLEX
MIRROR OPTICS - PHILIPS/CROMPTON/ HAVELL’S
SPORT LIGHT & LIGHT FITTINGS - PHILIPS/CROMPTON/ HAVELL’S
WALLFAN - CROMTON/HAVELL’S / USHA

The installation shall confirm in all respects to INDIAN STANDARD CODE OF PRACTICE
FOR ELECTRICAL WIRING AND INSTAQLLTION IS - 732 and IS2274. It shall also be in conformity
with the current Indian electricity rules.

a) Marking and arrangements for switchgear, Bus-Bars, Main connection and
auxiliary IS-375.
b) Specification for normal duly air break switches and composite units and fuses for
voltage not exceeding 1000 volts - IS 4064.
c) Specifications for enclosed distribution -IS 2675.
d) Installation and maintenance for switchgear IS-3072.
e) HRC Cartridge fuse links 650 volts IS-2208.
f) Specifications for PVC insulated cables for voltage up to 1100 volts-IS
694(Part- II).
g) Boxes for the enclosure of electrical accessories Part-I steel and boxes IS 5133.
h) 3 Pin plugs and sockets outlets IS-1293.
i) Adhesive insulating tapes for electrical purposes (part I & ill IS 24489).
j) DB cabinet shall be tested as per IS-2675 including insulation test, high voltage
test.
k) Shunt capacitors for power supply systems IS-2834.
l) DB cabinet shall be tested as per IS-2675 including insulation test, high voltage
test.


THE CONTRACTOR WILL PROVIDE A CERTIFICATE THAT THE HE IS HAVING A ELECTRICAL
WIREMAN OF CLASS (A) LICENCE TO UNDERTAKE AND CERTIFY
THE SAFETY OF THE WORKS UNDERTAKEN.


Signature of the Contractor






S.No.

Computer LAN cabling works

Unit

Qty

Rate

Amount

1.

P&F of UTP CAT 5 cable for computer nodes
(D Link make)

R.m 80



2.

Supply

& installation of 16 port unmanaged
switch 10/100 MBPS of D Link make

Each 1


3.

Supply and installation of 24 port jack panel
of D-link make

Each 1


4.

Supply & installation of 60 pole mounted
rack 18” height made of power coated MS
sheet of D-link make

Each 1


5.


Supply and installation of IO plates and SMB
as reqd complete with accessories of D Link
make

Each 12


6.

Supply & installation of patch cords (1
metre/2 meter)


Each. 18


7.

Labo
u
r For Data Cable Work

Each 1



Total
















×