Multiparametric
Cardiac MR
1
GE Cardiac MR Powered by DL
Cardiovascular Clinical Applications
1RR
3RR
Function Assessment 1RR 3RR Sonic™ DL
MOLLI
SSh MDE
2D PS MDE
Late Gadolinium SSh MDE, 2D PS MDE AIR™ Recon DL
ECV
Tissue Characterization AIR™ Recon DL
T2 Map , T1 Map , ECV Map
Morphology
AIR™ Recon DL
Wideband MDE
AIR™ Recon DL
4D Flow
Strain Analysis
3D Heart Nav.
AIR™ Recon DL
Perfusion MoCo
AIR™ Recon DL
+/- Stress
3D MDE FS Nav.
AIR™ Recon DL
Leveraging Deep Learning Based Recon
AIR™ Coil
AIR™ Recon DL
Sonic DL™
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
2
3rd Generation of AIR Recon DL
Ortho
Neuro
Cardiovascular
•
2D Festa
•
2D Spin Echo
•
2D Black Blood
•
2D Dual Echo
•
2D SSH-(PS)-MDE
•
Time Course
DL Recon
1st Gen
•
2D Spin Echo
•
2D T2* GRE
•
Single Shot Spin Echo
DL Recon
2nd Gen
•
2D EPI DWI (including FOCUS)
•
2D EPI DWI (including FOCUS)
•
2D PROPELLER
•
2D PROPELLER
•
2D PROPELLER
•
3D MDE with RT
•
3D CUBE
•
3D CUBE
•
3D LAVA/VIBRANT
•
3D Heart
•
3D T1
MPRAGE/BRAVO
•
3D GRE
•
3D MRCP
•
3D IFIR
•
2D FSE-Flex
(Orbits, H&N)
•
2D FSE-Flex
•
2D FSE-Flex
•
MoCo MOLLI &T1Map
DTI (Oncology)
•
CartiGram
•
SSH PS MDE FreeBreathing with RT
MR30
Reconstruction speed:
63,000 images/second.
No change in
reconstruction time.
Challenge the others!
Body/Onco
DL Recon
3rd Gen
•
•
2D Spin Echo
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
3
30-Minute CMR For Common Clinical Indications*
Heart Failure or
Cardiomyopathy
SIGNA
Substrate For
LV Arrhythmia
Ischemic & Viable
Myocardium
Patient Prep
Non-Ischemic vs.
Ischemic Injury/
Myocarditis
Power Injector
ECG Leads
IV Line
AIR™ Coil
AIR™ Recon DL
Localizer
Cardiac Function
3-CH, 4-CH, 2-CH
T1 Map Native
5(3)3
T2 Map
Perfusion +/Stress
Cardiac Function SAX
Late Gd – Enhancement
TI Scot - SAX SSh PS MDE
Late Gd – Enhancement
3-CH, 2-CH, 4-CH SSh PS MDE
Scan Time
01:00 min
01:20 min
01:15 min
05:00 min
05:30 min
01:30 min
01:35 min
0:00 – 5:00 min
06:00 min
07:20 min
08:35 min
13:35 min
19:05 min
20:35 min
22:10 min
Gd Contrast Injection
* Reference: Raman SV, et al. JCMR 2022: “30-minute CMR for common clinical indications: a SCMR white paper”
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
4
Myocardial Mapping
/>
Myocardial Mapping
/>
Multiparametric CMR with A.I
Calculates
ECV
T1 Map | MOLLI
T1 Map | SMART1
T2 Map
Quantitative assessment of T1
relaxation time of myocardium
Quantitative assessment of T1
relaxation time of myocardium
independent of heart rate
Quantitative assessment of T2
relaxation time of myocardium
AIR Recon DL
Motion Correction – Free Breathing
T2* Map
Quantitative measurement to
assess iron overload
Polar Map T2
Polar Map T1 Native
Multiparametric CMR with A.I
Native T1 Map
1421 ms
T2 Map
77 ms
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
8
Multiparametric CMR with A.I
EF Analysis
Strain Analysis
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
Multiparametric CMR with A.I
Delayed
enhancement
2D
Single Shot
1 slice per BH
(10-15 slices)
2D MDE
High resolution
Fat Sat
2D PS-MDE
Less sensitive to
sub-optimal TI
3D
Fast & Robust
Whole heart in 1-2 BH
possible free-breathing
2D SSh
MDE
Robust,
free-breathing
2D SSh
PS-MDE
Robust,
less sensitive to TI
Free-breathing
Fast & Robust
Whole heart in 1-2 BH
possible free-breathing
3D MDE BH
Fast
High resolution
Low SNR
3D MDE Nav
Free-breathing
Very high resolution
Low SNR
Multiparametric CMR with A.I
Conventional
AIR™ Recon DL
Short Axis Post contrast
2.6 x 3.0 x 8 mm, 2:53 min
Conventional
AIR™ Recon DL
4 chamber Post contrast
2.6 x 3.1 x 8 mm, 0:10 min
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
11
Multiparametric CMR with A.I
Single Shot PS MDE with TI set for myocardium
Single Shot PS MDE with TI set for blood pool
SNR challenges
Single Shot PS MDE with TI set for blood pool
SNR challenges AIR™ Recon DL
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
12
Multiparametric CMR with A.I
Short Axis cine FIESTA
Voxel size 1.8 x 1.4 x 7
Long Axis cine FIESTA
Voxel size 1.9 x 1.7 x 7
Short Axis SSh MDE
Voxel size 1.9 x 1.9 x 7
16 slices - 47s
Long Axis SSh MDE
Voxel size 2.0 x 2.0 x 7
3 slices - 12s
Free Breathing
Free Breathing
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
13
4D Flow
Comprehensive Cardiac Solutions For Complicated Exams
What is it?
•
3D Cine (EFGRE)
•
Capture data in 7 dimensions
•
Valvular Disease
Shunts
3 in space, 1 in time, and 3 in velocity direction
Benefits
•
Non-invasive 3D cardiac anatomy, function, and flow in 1
free-breathing, 8 min scan
•
Unsupervised cardiac imaging – no expertise or clinician
guidance needed
•
Faster cardiac exams help to shorten backlog scheduling
times
•
Cloud-based or on-premise visualization and reporting
attracts new referrals
Aortic Disease
Congenital Heart
Disease
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
4D Flow
Velocity Vector Flow Visualization
SVC connection to RPA
IVC Connection to PA
Free Breathing 4D FLOW
TR/TE(ms): 4 / 2.2
Matrix: 180 x 180 | S.TH: 1.1
Scan Time: 06:35
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
15
MR30 : New Cardiac MRI Applications
Sonic DL™ Cine
Sonic DL™ - 8x
3RR/slice | 5BH x 6s
Free-Breathing PS MDE
w/ AIR™ Recon DL
Courtesy University of Chicago
Fat-Sat Free-Breathing 3D MDE
w/ AIR™ Recon DL
Courtesy Hospital Clinic Barcelona
3D Heart
w/ AIR™ Recon DL
Courtesy Centro Cardiologico Monzino
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
16
AIR™ Recon DL | 3D HEART
Improve image quality for better assessment of coronary arteries without contrast injection
LAD
LCX
RCA
LAD= Left Anterior Descending
LCX= Left Circumflex Artery
LCX
LAD
RCA
RCA= Right Coronary Artery
3D HEART | Free Breathing
AIR™ Recon DL
AIR™ MP 20MM
Voxel size 1.6 x 1.6 x 1.0
Scan Time | 03:38
Data & images are courtesy of Centro Cardiologico Monzino Milan - Italy
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
Sonic DL™ *
Cardiac Cine
* Not yet CE marked. Not available for sale in all regions.
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
18
Sonic DL™ * | Life-speed imaging
Deep-learning accelerated FIESTA Cine for rapid assessment of
heart function, volumes, mass and structure
Reduce scan time while preserving image quality
Free breathing or breath–hold
Retrospective cardiac triggering
Up to 12x acceleration
As fast as 1 heart-beat per slice
ASSET - 2x
8RR/slice | 10BH x 9s
Sonic DL™ - 6x
6RR/slice | 10BH x 6s
* Not yet CE marked. Not available for sale in all regions.
Sonic DL™ - 8x
3RR/slice | 5BH x 6s
Sonic DL™ - 12x
1RR/slice | 3BH x 6s
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.
19
Sonic DL™ * | Life-speed imaging
Productivity in a beat
Innovation in a flash
Rapid imaging reduces motion artifacts
for the patient who cannot follow breath hold command.
Higher spatial and temporal resolutions
30 frames
00:10 sec
58 frames
00:07 sec
whole heart coverage
1:42 min
Paced for patients
Where simplicity meets swiftness
Accommodating patient challenges with free breathing
Improve clarity despite arrhythmia
Whole heart coverage
2:10 min
Breath-hold
Whole heart coverage
00:51 sec
Free breathing
* Not yet CE marked. Not available for sale in all regions.
whole heart coverage
1:45 min
whole heart coverage
00:59 sec
whole heart coverage
00:24 sec
© 2023 GE HealthCare. GE is a trademark of General Electric Company used under trademark license.