Tải bản đầy đủ (.pdf) (41 trang)

HƯỚNG DẪN LẮP QUẠT LY TÂM

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (1.17 MB, 41 trang )

Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Pressure Recovery

Ancillaries
About Us
General Info
Installation

Look for opportunities for pressure recovery at centrifugal exhaust fan outlets.

Don't

Do

To determine the system resistance the


discharge losses have to be added before
selecting the fan.

With a correctly designed discharge diffuser the
pressure recovery in the diffuser will reduce the
system total pressure.

Discharge losses are highest in this arrangement
and are equivalent to one velocity head.

Included angle of diffuser to be 15o or less.

Tech Talk
Locate Us

Discharge losses reduced by up to 75% in this
arrangement.

10:23:49 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and

Don'ts

Fans
Attenuators

Installation
Instructions

Spinning of air at inlet connection

Ancillaries
About Us
General Info
Installation

Ensure unintentional spinning of air at fan inlet does not take place.

Don't

Do

Unintentional spinning of air caused by a poorly
designed inlet box can reduce performance by
around 25%.

Splitters at the inlet help prevent spinning flow.
Turning vanes, where R/W<1.0 improves
uniformity of flow approaching the fan inlet.

Avoid small inlet boxes as they can cause

surging.

Inlet boxes should be amply sized.

Tech Talk
Locate Us

10:27:07 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Eccentric inlet flow

Ancillaries

About Us

Do ensure inlet air to the fan is evenly distributed.

General Info
Installation
Tech Talk

Don't

Do

Locate Us

Eccentric air distribution at fan inlet diminishes
fan performance by up to 45% because the main
flow is accelerated through an effectively smaller
duct area on one side while turbulence and high
intensity pressure fluctuations occur on the other.
Noise level is also increased

10:27:42 AM

Rated fan performance is only achieved when air
flows evenly into the fan impeller.


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:

Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Bends on fan discharge

Ancillaries
About Us
General Info

Bends near fan discharge should be in the direction of wheel rotation to prevent needless
pressure loss

Installation
Tech Talk

Don't

Do


Locate Us

Air moves faster at the outside of the fan housing
and is not evened out before striking the abrupt
bend. A very high pressure loss results.

10:28:01 AM

Improved discharge arrangement with radiused
bends and splitters or different fan mounting
position will reduce system losses. Bends should
‘rotate’ in the same direction as the impeller.


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions


Inlet plenums

Ancillaries
About Us
General Info
Installation

Ensure eccentric flow is not caused by inlet plenum.

Don't

Do

With a single width fan the airflow takes a single
turn to enter it; eccentric flow is created.

Selection of a double inlet fan improves airflow.
Central positioning of the fan and plenum entry
grille will also assist.

Tech Talk
Locate Us

10:28:31 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:

Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Motor position

Ancillaries
About Us
General Info
Installation

Position the motor of a belt-driven fan such that the belt leaving the motor pulley is
uppermost as this will increase belt arc of contact.

Don't

Do

Belt leaving motor pulley is less taut than upper
length and the slight sag will reduce arc of

contact on the drive pulley.

Arrangement with the maximum arc of contact of
the drive pulley where energy is applied, reduces
belt squeal at start-up and improves efficiency.

Tech Talk
Locate Us

10:28:48 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

The correct fan for the application


Ancillaries
About Us
General Info
Installation

Don't

Do

Don’t use a centrifugal blower if space is at a
premium and avoid unnecessary bends.

Do consider the space saving advantages of an
in-line fan. It can be centrifugal or axial, the
selection being governed by the fan duty and
noise level required.

Tech Talk
Locate Us

10:29:08 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's

Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Inlet cones

Ancillaries
About Us
General Info
Installation

Use inlet cones for axial fan free air intakes to improve performance and
noise level.

Don't

Do

An abrupt entry will generate turbulence at the
impeller. Note blade tips will be starved of air
which reduces pressure development capability,
induce stall and increase the noise level
generated by the fan.


By fitting a correctly designed inlet cone the air
flow to the impeller will be uniform resulting in the
optimum performance being achieved and
minimum noise level.

Tech Talk
Locate Us

10:30:03 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Flexible connection to fan


Ancillaries
About Us
General Info

Flexible connections must be taut or else turbulence at the fan inlet, noise level and
pressure loss are all increased.

Installation
Tech Talk

Don't

Do

Slack or misaligned flexible connectors reduce
the effective duct area. This generates turbulence
and the blade tips are starved of air. Fan
performance is reduced and noise levels
increased.

If flexible connectors are fitted they should be
remote from the fan and ensure they are taut.
The air to the impeller tips is then not obstructed
allowing the fan to operate to its optimum and
minimises noise generation.

Locate Us

10:30:17 AM



Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Duct restrictions
at fans

Installation
Instructions

Ancillaries
About Us
General Info
Installation

Ducts significantly smaller than the fan diameter create turbulence if transitions connect
directly to fan.


Don't

Do

An abrupt duct expansion at fan inlet causes air
separation from the duct, starves the impeller
tips, creates turbulence, reduces performance
and generates increased noise.

Duct expansions on the inlet to axial flow fans
should be avoided where at all possible.

Tech Talk
Locate Us

10:30:47 AM

If essential the transition should have an included
angle of not more than 15o.


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and

Don'ts

Fans
Attenuators

Installation
Instructions

Turning vanes at sharp bends

Ancillaries
About Us
General Info
Installation

Fit turning vanes in elbows adjacent to axial fans

Don't

Do

Eccentric flow conditions at both inlet and outlet
will result in part of the impeller being starved of
air and the fan not operating satisfactorily.

Square-to-round transitions and turning vanes in
elbows assists uniform airflow; this is a
compromise only and by no means ideal.

Tech Talk

Locate Us

10:31:08 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Isolating vibrating fans

Ancillaries
About Us
General Info
Installation

Vibration transmission through building structures is a frequent problem


Don't

Do

Do not bolt fan directly to the building structure as
noise and vibration can be transmitted directly in
to the building fabric.

Isolate fan and duct from the building structure
with fan on neoprene or spring isolators and
suitable flexible connectors.

Tech Talk
Locate Us

10:31:18 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts


Fans
Attenuators

Installation
Instructions

Guards

Ancillaries
About Us
General Info
Installation

Safety of personnel around rotating machinery is crucial.

Don't

Do

Don’t leave open fan inlets unguarded. This is
unsafe to personnel and machinery. In addition it
may be illegal and leave the building owner or
installer open to prosecution.

Ensure open fan inlets are fitted with suitable
guards. These should be designed to comply with
local regulations and not only protect against
injury but lessen the risk of a foreign object
entering the fan and causing damage.


Tech Talk
Locate Us

10:31:57 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Obstructions at fan inlet

Ancillaries
About Us
General Info
Installation


Don’t obstruct fan inlet

Don't

Do

The impeller can be starved of air when the inlet
to the fan is obstructed. This effectively increases
the system resistance thereby reducing the air
flow being handled by the fan.

Allow a gap at least equal to 1 fan diameter
between the fan intake and nearby obstructions,
even then fan performance can be less than
rated.

Tech Talk
Locate Us

Always fit an inlet cone on open intakes.

10:32:17 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's

Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Obstructions at fan outlet

Ancillaries
About Us
General Info
Installation

Don’t obstruct fan outlet.

Don't

Do

When the discharge is too close to a wall the
obstruction generates noise and increases
discharge losses.

Allow a gap of at least one fan diameter between
fan outlet and obstruction and fit a diffuser on the

discharge.

Tech Talk
Locate Us

10:32:51 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Transitions

Ancillaries
About Us
General Info

Installation

Ensure symmetrical transitions from duct equipment to fan inlet.

Don't

Do

Poor airflow - little or no airflow through top of
coil.

Centralise the fan to ensure uniform airflow
through the coil

Tech Talk
Locate Us

10:33:54 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's & Dont's
Home

Do’s and
Don'ts


Fans
Attenuators

Installation
Instructions

Air flow dead zones

Ancillaries
About Us
General Info
Installation

Unducted air extract fans require careful location to obtain an even airflow across the room

Don't

Do

Part of room is starved of ventilation air

Because of cross-flow ventilation air circulation and
quality of ventilation is optimised.

Tech Talk
Locate Us

10:34:19 AM



Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Roof ventilator short-circuiting of air

Ancillaries
About Us
General Info
Installation

Ensure the roof ventilator base has an airtight seal.

Don't

Do


If the unit does not have an airtight seal between
the base and the upstand, short-circuiting of
outside air can occur thereby reducing the
amount of air being exhausted from the building.

An airtight seal between the upstand and fan
base prevents short-circuiting of outside air
ensuring the fan is exhausting from the
designated space.

Tech Talk
Locate Us

10:34:58 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators


Installation
Instructions

Prevailing winds

Ancillaries
About Us
General Info
Installation

Mechanical roof ventilator units perform best if influence of prevailing wind is minimal.

Don't

Do

Unit above ridge is exposed to crosswinds.
Exhaust capacity may be reduced due to backpressure effects.

Roof unit relatively sheltered from prevailing
winds suffers less from back-pressure effects.

Tech Talk
Locate Us

10:35:11 AM


Fantech on-line ventilation fans & noise control product catalogue


Product Code Search:
Help?

Do's & Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Back-draft shutters

Ancillaries
About Us
General Info

Butterfly back-draft shutters on a roof unit should be installed so gravitational effect on
each leaf is the same.

Installation
Tech Talk

Don't


Do

Don’t have shutters at 90o to roof fall. The lower
shutter must overcome a greater gravitational
effect for even air flow. Also the top damper may
go over top dead centre and not close.

Each leaf has the same gravitational effect when
shutters are parallel with roof fall.

Locate Us

10:35:43 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation

Instructions

Mounting of Roof Units to ductwork

Ancillaries
About Us
General Info
Installation

Don't

Do

Don’t connect to the ‘eye’ of the base as this
increases pressure losses on the intake.

Size inlet duct to fit roof unit overflashing.

Tech Talk
Locate Us

10:35:57 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's

Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Transitions

Ancillaries
About Us
General Info
Installation

Don't

Do

Abrupt transitions immediately adjacent to an
attenuator will cause attenuator pressure drop to
increase.

Ensure transitions close to attenuators are
gradual or, better still, remote.

Tech Talk

Locate Us

10:36:21 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Installation
Instructions

Transitions

Ancillaries
About Us
General Info
Installation

Don't


Do

Abrupt transitions immediately adjacent to an
attenuator will cause attenuator pressure drop to
increase.

Ensure transitions close to attenuators are
gradual or, better still, remote.

Tech Talk
Locate Us

10:36:40 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:
Help?

Do's and Dont's
Home

Do’s and
Don'ts

Fans
Attenuators


Installation
Instructions

Volume control dampers

Ancillaries
About Us
General Info
Installation

Don't

Do

Don't site volume control dampers or fittings too
close to attenuators as they can cause a dramatic
increase in attenuator pressure drop.

Allow for a setting duct between volume control
dampers and attenuators.

Tech Talk
Locate Us

10:37:20 AM


Fantech on-line ventilation fans & noise control product catalogue

Product Code Search:

Help?

Do's & Dont's
Home

Do’s and
Don'ts

Fans
Attenuators

Attenuators in
relation to bends

Installation
Instructions

Ancillaries
About Us
General Info
Installation

Don't

Do

Don't use attenuator splitters when sited close to
a bend.

Do ensure attenuator splitters are in the plane of

the bend as shown.

Tech Talk
Locate Us

Fit turning vanes only if R/W<1.0