VALIANT
COMMUNICATIONS
VCL-MX
TM
Version 6 - E1 Multiplexer
User Installation Manual
Copyright: Valiant Communications Limited - 2016
1
Notice
VCL-MX Version 6 - E1 Multiplexer
Warranty
This Valiant product is warranted against defects in material and workmanship for a period of
one year from the date of shipment. During the warranty period, Valiant will, at its discretion,
either repair or replace products, which prove to be defective. For warranty service or repair,
this product must be returned to a service facility designated by Valiant. The buyer shall
prepay shipping charges to Valiant and the company shall pay shipping charges to return the
product to the buyer. However, the buyer shall pay all the shipping charges, duties and taxes
for products returned to Valiant from another country.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate
maintenance by the buyer. The buyer-supplied firmware or interfacing, unauthorized
modification or misuse, operation outside of the environmental specifications for the product
or improper site preparation or maintenance.
Exclusive Remedies
The remedies provided herein are the buyer's sole and exclusive remedies. Valiant shall not
be liable for any direct, indirect, special, incidental or consequential damages, whether based
on contract or any legal theory.
Notice
This manual contains information that is proprietary to Valiant Communications Limited. No
part of this publication may be reproduced in any form whatsoever without prior written
approval by Valiant Communications Limited.
Safety Warnings
!
The exclamation point within a triangle is intended to warn the operator or
service personnel of operation and maintenance factors relating to the product
and its operating environment, which could pose a safety hazard.
Always observe standard safety precautions during installation, operation and maintenance
of this product. Only qualified and authorized service personnel should carry out adjustment,
maintenance or repairs to this instrument. No adjustment, maintenance or repairs should be
performed by either the operator or the user.
UALITY ASSURANCE PROGRAM
Valiant’s products are designed and manufactured under a strict Quality Assurance
Program based on the ISO 9001:2008, 14001:2004 and ISO 10002:2004 philosophy
and principles. Valiant pays very special attention to its vendor development program
which ensures an “end-product” of the highest quality at the most cost effective prices.
Copyright: Valiant Communications Limited - 2016
2
Index
VCL-MX Version 6 - E1 Multiplexer
INDEX
Particulars
Section 1: System Description and Installation
Product Overview
Key Features
Additional Features
Highlights
OAM Features
Management and Monitoring
OAM: Operation and Management Ports
Security and Protection
Transmission Medium
Multi-service platform
Configuration and Flexibility
Synchronization Clock
Application of VCL-MX
System Overview and Architectural Details
Shelf Description
Chassis / System Backplane
System Management
Section 2: Technical Specifications
E1 Interface
FXS, Voice Frequency Interface
FXO, Voice Frequency Interface
Ring Generator Card
Power Supply Card
Hot-Line Interface Card
Low Speed Data Interface Asynchronous RS232
E&M 2 Wire / 4 Wire Voice Frequency Interface
64Kbps Data Interface
G703 @ 64kbps, Synchronous Data Interface
Relay I/O Interface Card
Relay Specifications (Drivers)
Dry Contacts Sensors
Copyright: Valiant Communications Limited - 2016
P No
10
11
11
12
13
13
13
13
13
14
14
14
14
15
15
16
17
17
18
19
20
21
21
21
22
22
23
23
23
24
24
24
3
Index
VCL-MX Version 6 - E1 Multiplexer
INDEX
Particulars
Universal Data Interface
Integrated IEEE C3794 Teleprotection Interface
8 E1 Plus 100Mbps Ethernet Fiber Optical Transport Interface
Management Interface
Protection
Power Consumption
Environmental
Dimensions
P No
24
25
25
26
26
26
26
26
Section 3: Application Diagram and Connection Details
Applications
Telco Networks Providing Services
Applications Diagram
System Layout
Core System Composition
VCL-MX Version 6 - Back View
Connection Details
Common Connector Pinout Details
27
28
28
28
31
32
33
34
35
Section 4: Card Description and Cabling Details
Power Supply Card
OAM Card
Ring Generator Card
Control Card
E1 Interface Card
Redundant E1 Interface Card
FXS (SLC), Voice Frequency Interface Card
FXO (JNC), Voice Frequency Interface Card
Hotline, Voice Frequency Interface
2 Wire / 4 Wire E&M, Voice Frequency Interface Card
G703 Interface Card
8 E1 Plus Fast Ethernet Fiber Optical Transport Interface Card
RIO (Relay Input Output) Card
36
37
38
39
40
43
46
51
55
59
63
70
73
75
Copyright: Valiant Communications Limited - 2016
4
Index
VCL-MX Version 6 - E1 Multiplexer
INDEX
Particulars
Low Speed Data Interface
64Kbps Data Interface Card
Nx64Kbps Data Interface Card
VCL-TP, 4 Command Teleprotection Interface Card
4xIEEE C37.94 Channel Card
P No
79
82
89
95
99
Section 5: OAM Description and Setup Rules
OAM Default Settings
Network Address Settings
Default Usernames and Passwords
SNMP Settings
Description: OAM Card
Super User - Definition
Assigning a new password
User - Definition
The OAM Password Strength Standards and Compliance
Audit User - Definition
Applicable Security Conditions
100
101
101
101
101
102
102
103
103
105
107
107
Section 6: HyperTerminal Settings
To use HyperTerminal for executing the CLI commands
HyperTerminal settings for COM Port (RS232) and USB Port
HyperTerminal settings for 10/100BaseT Management Port
Telnet without using HyperTerminal utility
Retrieving Log file in text format using Web Browser
109
110
111
117
123
124
Section 7: USB Serial Port Drivers
Installing USB Serial Port Drivers
126
127
Section 8: CLI Commands
Structure of CLI Command Statements and Conventions
OAM / Normal Configuration Mode
OAM Interface Configuration Commands
To Enter OAM config level
To View list of OAM configuration commands
134
135
137
137
137
138
Copyright: Valiant Communications Limited - 2016
5
Index
VCL-MX Version 6 - E1 Multiplexer
INDEX
Particulars
All User Help Commands
To Set SNMP Trap Target Port Address
To Set SNMP Trap Target Port
To Set Trap Target Community
To Change Self Password
To Check OAM Firmware Version
To View OAM Settings
To Exit from OAM Configuration Mode
To Exit from system
To Set System IP Address
To Set Subnet Mask
To Set Default Gateway
To Configure DNS IP Address
To Set SNMP Read Community
To Set SNMP Write Community
To Enable / Disable the SNMP
To Add New User
To Delete the User
To Change the Super User Password
To View System User List
To View log of all successful Users
To View log of all failed attempts
To View log of SSH Users
To View log of Telnet Users
To View log of Serial Port Users
To View log of All Authorized Users
To Change Audit User password
Test Command
To View ping result
System Commands
To View the Available Help Menus
Help CLI Structure Menu
Control Card Statements
Copyright: Valiant Communications Limited - 2016
P No
139
139
139
139
139
140
141
141
141
141
141
141
142
142
142
142
142
143
143
143
143
143
143
144
144
144
144
144
144
145
145
149
151
6
Index
VCL-MX Version 6 - E1 Multiplexer
INDEX
Particulars
To Set the System Factory Default Settings
System Default Settings
To Check the System Boot Status and Self Test Error
To Check the Ringer and Input Power Status
To Set / Check the System Clock Priority
To Set / Check RTC (Real Time Clock) Settings
To Reset System / Interface Card and Check System Configurations
To Check the System and Interface Card Status
E1 Interface Card Statements
To Set Default and Configure the E1 Card
To Configure the E1 Card (Framing, Alarms) and Clear Errors
To Check E1 Card settings
To Add / Remove an E1 Card
To Map the E1 Card - E1port to E1 port
To Unmap the E1 Card
To Check E1 Card Mapping
To Set Default and Configure the Tx / Rx Gain of FXS Card
To Configure the FXS Card
To Check the FXS Card
To MAP FXS Card - E1 to FSX
To Unmap FXS Card
To Set Default and Configure the Tx / Rx Gain of FXO Card
To Configure the FXO Card
To MAP FXO Card - E1 to FXO
To Check the FXO Card
To Unmap FXO Card
To Set Default and Configure the Tx / Rx Gain of E&M Card
To Configure the E&M Card
To Check the E&M Card
To MAP E&M Card - E1 to E&M
To Unmap E&M Card
To Configure the VF Card Custom Signaling
To Check / Configure Data and Signaling Loopback of RIO Card
Copyright: Valiant Communications Limited - 2016
P No
151
151
152
152
153
154
155
156
158
158
159
160
162
163
164
165
165
166
167
170
171
171
172
173
174
177
177
178
179
181
182
183
184
7
Index
VCL-MX Version 6 - E1 Multiplexer
INDEX
Particulars
To Configure Input Sampling / Level and Output Holding / Level of RIO Card
To Check the RIO Card
To MAP / UNMAP / Remove RIO Card - E1 to RIO
To Check / Configure Data and Signaling Loopback of RS232 Card
To MAP / UNMAP RS232 Card - E1 to RS232
To Check the RS232 Card
To Configure Data/Signaling Loopback and Enable/Disable alarm of G703 Card
To Check the G703 Card
To MAP / UNMAP G703 Card - E1 to G703
To Set default, Interface type, Configure Data Loopback and clock of 64IF Card
To Configure Loopback and clock of 64IF Card
To Check the 64IF Card
To Check the 64IF Card Signal Status
To MAP / UNMAP / Remove 64IF Card - E1 to 64IF
Optical Card Statements
To Set Default and configure the Framing ( CRC4)
To Clear Errors, Configure Frame, Alarms and Enable / Disable CAS
To Enable / Disable CAS and configure Loopback
To Clear Errors, Configure Frame, Alarms and Enable / Disable CAS
To Configure SFP and ALS mode
To Configure ALS
To Check Card ID, F/W Version, Settings and Boot Result
To Check E1 Loopback and E1 Alarms
To Check E1 Alarms and LIF Errors
To Check Laser Status
To Check SFP Settings and ALS Settings
To Configure SFP Parameters and Temperature Threshold
To Check SFP Voltage and Current Threshold
To Check SFP Transmit / Receive Power Alarm and Warning Threshold
To Check SFP Temperature, Voltage and Current
To Check SFP Receive and Transmit Power
To Check SFP warning
To Check SFP Alarms
To MAP / UNMAP Optical Card - E1 to Optical Card
To Add / Remove Optical Card and Check Mapping
Copyright: Valiant Communications Limited - 2016
P No
185
186
188
189
190
191
192
193
194
195
196
197
198
199
200
200
201
202
202
203
204
205
206
207
207
208
209
210
211
212
213
214
215
216
217
8
Index
VCL-MX Version 6 - E1 Multiplexer
INDEX
Particulars
TP4 4 Channel Teleprotection Optical Card
MXV6 TP4 4 Channel Teleprotection IF Card
CLI Commands Core Features Settings
CLI Default Config Commands
CLI Misc Commands
CLI Teleprotection Commands
CLI RTC Commands
CLI Query Statements Commands
CLI Commands External Display / Alarms Unit Statements
CLI Commands Mapping Statements
4xIEEE C37.94 Channel Card
Help Query Statements
Settings Statements Description
Query Statements - Basic Setting Description
Map C37.94 Card - E1 to TP
Section 9: Ordering Information
VCL-MX E1 Core System (Common Equipment)
VCL-MX, User Configurable Interfaces
Optional and Accessories
Support
Copyright: Valiant Communications Limited - 2016
P No
218
218
218
218
219
220
221
222
223
224
225
225
227
228
229
231
232
233
236
238
9
VCL-MX Version 6 - E1 Multiplexer
Section 1
SECTION: 1
System Description and Installation
Copyright: Valiant Communications Limited - 2016
10
VCL-MX Version 6 - E1 Multiplexer
Product Overview
Product Overview
VCL-MX Version 6 - 80 E1 Multiplexer may be
used for inter-connecting legacy voice and
data networks, provisioning and managing
bandwidth on a E1 channelized level as well as
64Kbps, DS-0 time-slot level and as a digitalaccess cross-connect equipment. Due to the
changing traffic patterns, there is a need to
support multiple services from the same
equipment like integrated data transport, better
network management etc. This necessitated
evolution to next generation E1 Multiplexer.
Redundant control card and power supply and
redundant control card options make it an ideal
solution for network service providers seeking to integrate and provide legacy and the next generation
services from a single platform.
Next generation E1 Multiplexer has emerged as one of the most economical and technologically viable
solutions for transmitting both (voice and data) over carrier networks. This technology offers savings
on investments / power and space to service providers.
Valiant Communications provides efficient solutions in this field using the E1 Multiplexer series
products. E1 Multiplexer provides a full range of solutions in this evolving field of next generation
telecom solutions. E1 Multiplexer family provides the unique advantage of carrying both voice and
data over PDH. In addition to being affordable, these products have built-in modularity, which allow
easy upgradeability. This upgradeability feature allows the customer to evolve in a “build-as-you-grow”
concept. Along with the Valiant Communications as Network Management solution the E1 Multiplexer
family provides the following features:
!
!
!
!
!
!
Easy network manageability
Lower cost per line
Easy upgradeability
Carrying both data and voice over PDH
Easy integration to SDH network
Higher reliability.
Key Features
VCL-MX Version 6 - E1 Multiplexer provides the advanced features and capabilities, listed below:
!
!
!
!
!
!
160Mbps, 80 E1 fully non-blocking cross-connect at 64Kbps (DS-0) level (2480 DS-0 any to
any time-slot cross-connect)
Multi-service platform may be used to provide a wide variety of voice and data services
from single chassis
1+1 E1 Link Protection / E1 Port Redundancy
1+1 Control Card Processor Redundancy
1+1 Cross-Connect Redundancy.
Copyright: Valiant Communications Limited - 2016
11
VCL-MX Version 6 - E1 Multiplexer
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Additional Features
1+1 Timing (Synchronization Clock) Redundancy. User selectable synchronization priority
1+1 input DC (-48V) Power Supply Redundancy
1+1 Dual Power Input Redundancy – allows the equipment to be powered from two separate
sources
Up to 144 FXO or 144 FXS channels per unit
Up to 72 E&M 2-wire / 4-wire channels per unit
Any “ mix” of data and voice channels in a single unit
Universal Slots, slot independent system so that any type of interface card may be inserted
and used in any card slot
Supports R2 CAS, ITU-T Q.421 and ITU-T Q.422 signaling
Supports CAS Custom / User Programmable ABCD Signaling
Bit Error Rate (BER) monitoring BER thresholds to generate BER alarms automatically
whenever alarm limits are exceeded
Supports Long Loops of up to 1200 Ohms
Supports 75 V RMS and 90 V RMS Ring Voltage Options
Supports A-law and Mu-law voice encoding
Supports sinusoidal un-balanced ring output
Provides a ring of ≥ 75 volts RMS into a load of 5 R.E.N. on each channel with a 0.30 Erlang
traffic pattern (5 R.E.N. load = 5 parallel phone load on each line)
May be used in a Point-to-Point, Point-to-Multi point, Add-Drop (drop-insert), Tree and Star
Topology
Telnet
SSH for secured access
SNMP traps
Maintains Access Security Log
GUI (Graphical User Interface).
Additional Features
!
!
!
!
!
!
!
!
!
Voice and Digital Data services
Any combination ("mix-n-match") of Voice and Digital Data services deployed from a single
VCL-MX "Smart Shelf” - 4, 8 and 16 channels per card
Wireless applications including Cellular Networks
Digital Microwave Radio
SCADA applications
ATM/Frame Relay circuit termination
Powerful Network Management System for monitoring and network control
Compliance with all relevant ITU-T (CCITT) recommendations
19-inch, 6U high construction.
Copyright: Valiant Communications Limited - 2016
12
VCL-MX Version 6 - E1 Multiplexer
Highlights
Highlights
!
!
!
!
!
!
!
!
!
Flexibility on use of transmission medium-copper, fiber or wireless
Choice of Interfaces for Applications
USB and RS232, Interface for local connection through the serial interface to the "Network
Control and Management Software”
Out-of-band system configuration and management interface
Channel assignment independent of slot position in the sub-rack
Extensive set of alarms
User selectable internal, external and loop-timed clock synchronization priority options
Universal slots - any interface card can plug in at any interface slot
OAM Card for management and monitoring.
OAM Features
Management and Monitoring
!
!
!
!
!
!
!
RS232 Serial Port, USB serial interfaces for local terminal access
10/100BaseT Ethernet Interface for remote access over an IP network
Encrypted Password Protection
Telnet – Remote access over IP links
SSH – Secured remote access using Secure Shell Protocol over IP links
SNMP Traps and NMS for real time remote monitoring and management over an IP network
Automatic Link Test feature link testing at user programmable periodical intervals.
OAM: Operation And Management Ports
!
!
!
RS232 Serial Port
USB COM Port
10/100BaseT Ethernet for remote access.
Security and Protection
!
!
!
!
!
!
Secured Access via SSH V2
Password Protection: Password Protection in compliance with the mandatory clauses of
the GR-815-CORE-2 specifications for secured access control
Logging: Maintains a log of all successful and un-successful attempts. Logged information
includes the ID and the IP address of the accessing entities. Alerts the administrator if the un
-successful logging attempts exceed 3.
Security Audit: All access logs for up to 30 days are maintained for security audit purposes.
Security log entry of any request or activity including that user-ID (including IP address, if
applicable), to establish user accountability
Report Generation / Audit Trail
Security Administration.
Copyright: Valiant Communications Limited - 2016
13
Transmission Mediums
VCL-MX Version 6 - E1 Multiplexer
Transmission Mediums
The VCL-MX offers an excellent flexibility on the choice of transmission medium over which it may be
deployed. The transmission medium can be either of the following:
!
!
!
Copper
Optical Fiber
Wireless.
Multi-service platform
VCL-MX Version 6 - E1 Multiplexer supports both data and voice traffic. It supports the following
interfaces:
Voice Interfaces
FXS, FXO, Hotline, 2/4 wire E&M, Ring Generator, GEN GEN / Magneto Interface Card1 and 8 x fiveway / 30 x three-way voice conferencing
Data Interfaces
E1 Interface (Cross-Connect @64Kbps), G.703 Co-directional, Ethernet PDH Optical Fiber, Relay I/O
Card, 64Kbps Sync - 19.2Async, Low speed RsS232 , N*64 universal Data Interface Card, BRI ISDN
“U” Interface and IEEE C37.94 Teleprotection Interface.
Configuration and Flexibility
VCL-MX Version 6 - E1 Multiplexer can be configured as a Terminal Multiplexer (TMUX). It can support
diverse topologies like point-to-point, ring, star and tree.
It can be configured in various topologies supporting both electrical and optical interfaces. It can take
modular cards, which would enable the customers to start small and grow as traffic demands scale.
Synchronization Clock
Timing options
Synchronization sources
Default option
Loop-timed clock
Internal Clock, Loop-Timed Clock, External Clock. User
Selectable synchronization priority
Internal Clock, span clock timing derived from incoming
HDB3 links (Loop-Timed), External Clock (75 Ohms -TTL
and 120 Ohms -Bits clock)
Internal Clock (Stratum 3)
Best possible clock from incoming E1 link on the basis of
automatic BER Test
Copyright: Valiant Communications Limited - 2016
14
VCL-MX Version 6 - E1 Multiplexer
Configuration and Flexibility
Application of VCL-MX
!
!
!
!
!
!
Junction Mux – for digital interconnection of analog exchanges
Point-to-Point application
Wireless network applications
Micro-Cellular infrastructure applications for providing cell-switch connectivity
Wide area networking
Internet access over POTS lines - all POTS interfaces operate @ 64Kbps.
System Overview and Architectural Details
The VCL-MX Version 6 - E1 Multiplexer provides full range of POTS (voice) and digital data services to
subscribers located at different locations, requiring for interconnecting and establishing a network over
an E1 Link. The VCL-MX is a simple, yet powerful E1 Channel Bank for connecting and integrating
analog communication equipment with digital E1 services.
E1 Multiplexer platform has been envisaged to address the growing demand for an ultra-compact
Terminal Multiplexer and provide Ethernet-over-PDH functions.
VCL-MX Version 6 - E1 Multiplexer has a multi-slot chassis with TDM backplane. In the chassis, there
are ten (10) traffic slots meant for tributary cards (line cards) such as E1 Interface (Cross-Connect
@64Kbps), FXS, FXO, Hotline, 2/4 wire E&M, G.703 Co-directional, Ethernet PDH Optical Fiber, RIO,
64Kbps Sync - 19.2Async, Low speed RS232 and N*64 universal Data Interface Card.
Copyright: Valiant Communications Limited - 2016
15
Shelf Description
VCL-MX Version 6 - E1 Multiplexer
Shelf Description
Slot 1
PSU
Slot 3 Slot 5
Slot 7
Slot 9
Slot 11
Slot 13
Slot 15
Slot 17
OAM
E C U P
R O S W
R M B R
VCL-MX
Voice & Data
Multiplexer
USB
PORT
LAN RESET
- 48V DC 1
- 48V DC 2
- 48V
CLK
CLK
SYNC
SYNC
SYNC
SYNC
SYNC
SYNC
SYNC
SYNC
SYNC
SYNC
LAN
PORT
4 3 2 1
SYNC
ALM
5V DC
RING
STATUS
STATUS
BUSY
4 3 2 1
8 7 6 5
SYNC
ALM
RING
BUSY
4 3 2 1
BUSY
RING
BUSY
RING
BUSY
8 7 6 5
RING
8 7 6 5
BUSY
BUSY
RING
12 11 10 9
8 7 6 5
BUSY
BUSY
RING
12 11 10 9
8 7 6 5
RING
12 11 10 9
8 7 6 5
BUSY
BUSY
RING
12 11 10 9
8 7 6 5
RING
BUSY
RING
BUSY
RING
BUSY
RING
BUSY
RING
BUSY
RING
BUSY
RING
BUSY
16 15 14 13
16 15 14 13
16 15 14 13
8 7 6 5
RING
BUSY
12 11 10 9
RING
16 15 14 13
BUSY
BUSY
12 11 10 9
BUSY
16 15 14 13
4 3 2 1
RING
8 7 6 5
RING
RING
12 11 10 9
BUSY
4 3 2 1
RING
RING
RING
ST ERR
RING
4 3 2 1
BUSY
BUSY
16 15 14 13
ST ERR
BUSY
4 3 2 1
RING
RING
12 11 10 9
ST ERR
RING
4 3 2 1
BUSY
BUSY
BUSY
CONFIG
BUSY
4 3 2 1
RING
RING
8 7 6 5
CONFIG
RING
4 3 2 1
BUSY
16 15 14 13
12 11 10 9
RING
BUSY
16 15 14 13
16 15 14 13
BUSY
RING
BUSY
RING
BUSY
RING
BUSY
RING
RING
ST ERR
ST ERR
ST ERR
ST ERR
ST ERR
ST ERR
ST ERR
ST ERR
ST ERR
PSU
Blank
Plate
Ringer
Card
Control
Card
Control
Card
E1 Interface
Card
FXO
Card
FXS
Card
FXO
Card
FXS
Card
FXO
Card
FXS
Card
FXO
Card
FXS
Card
FXS
Card
- 48V DC 1
- 48V DC 2
5V DC
Slot 2
1.
2.
3.
4.
5.
6.
7.
8.
9.
Slot 4
Slot 6
Slot 8
Slot 10
Slot 12
Slot 14
Slot 16
Slot 1 and 2: 3U High – Slot numbers 1 and 2 are dedicated for the 1+1 redundant -48V DC
power supply cards
Slot 3: 3U High – Slot number 3 is dedicated for the OAM Card to access the system through
RS232 DB9 COM Port, USB COM Port, TCP/IP Telnet and SNMP V2.
Slot 4: 3U High – Slot number 4 is Reserved / Un-used.
Slot 5: 6U High – Slot number 5 is Reserved for the Ringer Card.
Slot 6: 6U High – Slot number 6 is dedicated for Main Control Card.
Slot 7: 6U High – Slot number 7 is dedicated for Standby (Redundant) Control Card.
Slot 8: 6U High – Slot number 8 is dedicated for the E1 Interface Card which shall be used to map
Voice and Data interface.
Slot 9: 6U High – Slot number 9 may be used for the redundant E1 Card or second E1 Card or
Voice and data interface cards such as FXS, FXO, Hotline, 2/4 wire E&M, G.703 Co-directional,
Ethernet PDH Optical Fiber, RIO, 64Kbps Sync-Async, Low speed RS232 and N*64 universal
Data Interface Card.
Slot 10~ Slot 17: 6U High – Slot numbers 9 to 17 are dedicated for the E1 Card or Voice and data
interface cards such as FXS, FXO, Hotline, 2/4 wire E&M, G.703 Co-directional, 4 Port Optical
Teleprotection interface, Ethernet PDH Optical Fiber, RIO, 64Kbps Sync-Async, Low speed
RS232 and N*64 universal Data Interface Card.
Copyright: Valiant Communications Limited - 2016
16
VCL-MX Version 6 - E1 Multiplexer
System Management
The Multiplexer may be used in Terminal or Drop-Insert configuration to provide:
!
!
!
!
Toll Quality Voice Services
Interconnect LAN (Campus Network)
Interconnect computer terminals various types of data terminals
Provide LAN-WAN Inter-connectivity.
Chassis / System Backplane
All connections are made at the rear of the chassis, providing interconnections between the various
plug-in cards and to the network. VCL-MX Version 6 - E1 Multiplexer supports high-density PDH cards.
The line cards terminate a combination of Voice, Data and E1 Interfaces.
The VCL-MX Version 6 - E1 Multiplexer provides a host of features facility over a network of VCL-MX
E1 Multiplexers, for applications.
An extensive set of alarms, for easy maintenance are provided in the system.
System Management
VCL-MX Version 6 – Drop-Insert Multiplexer offers a variety of management options. The VCL-MX
Version 6 E1 multiplexer management software can be configured using CLI (English text) commands
and GUI (Graphical User Interface). The management and configuration commands may be executed
from a VT100 terminal, Windows HyperTerminal, any DOS based system, Linux or UNIX based
system, or Telnet (remote management).
The equipment provides a wide choice of access ports for connecting to and executing management
and configuration commands through its OAM Card.
The OAM card provides:
a)
b)
c)
d)
e)
COM Port (DB9, RS232 Serial Port).
USB Port
10/100BaseT Ethernet Port (each multiplexer may be assigned an IP address and connected to
a LAN / IP network for remote access and management through the 10/100BaseT Ethernet Port
for out-of-band management)
SNMP V2.
Additionally, a Windows-based GUI (Graphical User Interface) to access and manage the
equipment. The GUI may be installed on a Windows-based PC.
The VCL-MX has an effective, CLI (text) and GUI based "Network Management Interface", which may
be used for configuring and monitoring multiple systems from a single central location.
Copyright: Valiant Communications Limited - 2016
17
VCL-MX Version 6 - E1 Multiplexer
Section 2
SECTION: 2
Technical Specifications
Copyright: Valiant Communications Limited - 2016
18
Technical Specifications
VCL-MX Version 6 - E1 Multiplexer
Technical Specifications
E1 Interface: (Part No. VCL-MX-1520-E1-5.0)
Maximum number of interface cards
(in a single chassis)
Number of interfaces per E1 Interface Card
Conformity (electrical)
Frame structure
Signaling
PCM sampling rate
Bit rate
Code
Nominal impedance
Peak voltage of a mark
For 120 Balanced Interface
75 Unbalanced Interface
Peak voltage of a space
For 120 Balanced Interface
75 Unbalanced Interface
Nominal pulse width
Pulse mask
Output jitter
Permissible Attenuation
Return loss at:
51.2 KHz to 102.4 KHz
102.4 KHz to 2048 KHz
2048 KHz to 3072 KHz
Jitter tolerance
Frame alignment
Loss and recovery of frame alignment
Loss and recovery of multi-frame alignment
As per requitement and upto 10
Used to map with Voice and Data Interface
8 E1 Interfaces
G.703
As per ITU (CCITT) G.704
Channel Associated Signaling
8,000 samples/sec
2048 Kbps ± 50 ppm
HDB3
120 Ohms balanced / 75 Ohms unbalanced
3.0 V ± 0.3 V
2.37 V ± 0.237 V
0 V ± 0.3 V
0 V ± 0.237 V
244 ns
As per ITU (CCITT) Rec. G.703
<0.05 UI (in the frequency range of 20Hz to 100KHz)
6dB at 1 MHz
> 12dB
> 18dB
> 14dB
As per ITU (CCITT) G.823
As per ITU (CCITT) G.732
As per Clause 3 of ITU (CCITT) G.732
As per Clause 5.2 of ITU (CCITT) G.732
Copyright: Valiant Communications Limited - 2016
19
Technical Specifications
VCL-MX Version 6 - E1 Multiplexer
FXS, Voice Frequency Interface: (Part No. VCL-MX-1525-16-5.0)
Maximum number of interface cards
Number of channels per cards
Interface type
Maximum number of channels
(in a single chassis)
Transmission performance
Line impedance
Voice Channel Frequency
Insertion loss / gain
User selectable range for gain /
insertion loss
Idle channel noise
Return loss
Longitudinal balance
Ring frequency
Ring voltage
Subscriber loop current
Overload level
Battery reversal
Dial pulse speed
9
16
FXS,
A-Law, 8 bit/sample, A=87.6 / 87.7, 13 segment coding
144
Fully compliant to ITU (CCITT) G.712 specification
600 Ohms (900 Ohms optional)
300Hz-3400Hz
-2.0 dB Nominal (user adjustable)
Adjustable range 30 dB to +3 dB in steps of 0.5 dB
0 dB to 18 dB
≤-65dB
300Hz - 600Hz - > 12dB
600Hz - 3400Hz - > 15dB
> 46dB between 300Hz to 3400Hz
16 Hz, 20 Hz, 25 Hz, 50 Hz
> 75 volts RMS into a load of 5 R.E.N. with a 0.30
Erlang Traffic pattern
> 30mA into a subscriber loop of 1200 Ohms
+3.14dBm ± 0.5dBm
All channels
50 pps - Pulse Dialing ≤ ± 2 ms / DTMF Dialing
BRI ISDN, 2B+D Interface Card: (Part # VCL-MX-1550-04-5.0)
BRI ISDN Interface
Compliance
Bit Rate
Frame Format
Line Code
Accepted Line Attenuation
Pulse Shape
Impedance
"U" Interface
Meets ANSI T1.601-1992 requirements
160 Kbits/s
2B+D as per ITU-T (CCITT) Rec.1.430
2B1Q as per ITU-T (CCITT) Rec.G.961
42dB at 40 Khz
As per ITU-T (CCITT) Rec.G.961
135 Ohms at 40KHz
Maximum distance : 5 km (4 miles) on 0.5 mm twisted Pan. Distance may vary with cable gauge.
For distance using various cable gauges please refer chart below.
Distance in kms. (Miles)
Wire Gauge (AWG/mm)
Line Rate
(Kbps)
144
19 (.9mm)
17.4 (10.8)
22 (.6mm)
11.6 (7.2)
Copyright: Valiant Communications Limited - 2016
24 (.5mm)
8.1 (5.0)
26 (.4mm)
5.5 (3.4)
20
Technical Specifications
VCL-MX Version 6 - E1 Multiplexer
FXO, Voice Frequency Interface: (Part No. VCL-MX-1530-16-5.0)
Maximum number of interface cards
Number of channels per cards
Interface type
Maximum number of channels
(in a single chassis)
Transmission performance
Line impedance
Voice Channel Frequency
Insertion loss
User selectable range for gain /
Insertion loss
Idle channel noise
Return loss
Longitudinal balance
Overload level
Battery reversal
Dial pulse speed
9
16
FXO
A-Law, 8 bit/sample, A=87.6 / 87.7, 13 segment coding
144
Fully compliant to ITU (CCITT) G.712 specification
600 Ohms (900 Ohms optional)
300Hz-3400Hz
-2.0 dB Nominal (user adjustable)
Adjustable range 30 dB to +3 dB in steps of 0.5 dB
0 dB to 18 dB
≤-65dB
300Hz - 600Hz - > 12dB
600Hz - 3400Hz - > 15dB
> 46dB between 300Hz to 3400Hz
+3.14dBm ± 0.5dBm
All channels
50 pps - Pulse Dialing ≤ ± 2 ms / DTMF Dialing
Ring Generator Card (Part No. VCL-MX-1540)
Rated power
Ring voltage
Frequency
15W / 30W
75Vrms/86Vrms
17Hz/20Hz/25Hz/50Hz
Power Supply Card (Part No. VCL-MX-1510)
Input DC voltage
Range of input
Output voltages
Output voltage variation
Full load output current
Input voltage reversal protection
Over current protection
Short circuit protection
Efficiency at full load
Ripple at full load
Spike at full load
-48V DC (nominal)
-36V to -72V DC
+5V, -5V, Filtered -48V (for terminal cards)
± 5%
4A at 48V DC
Provided in the card
6A at 48V DC
Current limit 6A. Recovers on removal of short
>91%
<5mVrms
<50mV
Copyright: Valiant Communications Limited - 2016
21
Technical Specifications
VCL-MX Version 6 - E1 Multiplexer
Hot-Line Interface Card: (Part No. VCL-MX-1525HTL-16-5.0)
Maximum number of interface cards
Number of channels per card
Maximum number of channels
Interface type
Transmission performance
Line impedance
Loop resistance
Voice channel frequency
Insertion loss / gain
User selectable range for gain /
insertion loss
Idle channel noise
Return loss
Longitudinal balance
Ring frequency
Ring voltage
Subscriber loop current
Overload level
Dialing
9
16
144
Hot-Line
A-law, 8 bit/sample, A=87.6 / 87.7, 13 segment coding
Fully compliant to ITU (CCITT) G.712 specification
600 Ohms (900 Ohms optional)
Upto 2000 Ohms
300Hz-3400Hz
-2.0 dB Nominal (user adjustable)
Adjustable range 30 dB to +3 dB in steps of 0.5 dB
0 dB to 18 dB
≤-65dB
300Hz - 600Hz - ≥ 12 dB
600Hz - 3400Hz - ≥ 15 dB
≥ 46 dB between 300Hz to 3400Hz
16 Hz, 20 Hz , 25 Hz, 50 Hz
≥ 75 volts RMS into a load of 5 R.E.N. with a 0.30
Erlang traffic pattern
≥ 30mA into a subscriber loop of 1200 Ohms
+3.14 dBm ± 0.5 dBm
Ring-down
Low Speed Asynchronous RS232 Data Interface (Part No. VCL-MX-1559-08-5.0)
Number of interfaces per card
Maximum number of interfaces
Mode
Bit rate
Character length
Stop bits
Parity
8
9
Asynchronous, RS232 (V.24/V.28 line drivers) - DCE
50 bps to 19.2 bps
5 / 6 / 7 / 8 (auto-select)
1 / 1.5 / 2 (auto-select)
Even / Odd / 0's / 1's / none (auto-select)
Copyright: Valiant Communications Limited - 2016
22
Technical Specifications
VCL-MX Version 6 - E1 Multiplexer
E&M 2 Wire / 4 Wire Voice Frequency Interface (Part No. VCL-MX-1535-08-5.0)
Maximum number of interface cards
Number of channels per card
Maximum number of channels
Interface type
Transmission performance
Line impedance
Voice channel frequency
Insertion loss / gain
User selectable range for gain
/ insertion loss
Idle channel noise
Return loss
Longitudinal balance
Dial pulse speed
Maximum M-Lead resistance
Maximum M-Lead current drain
Maximum E-Lead current
9
8
72
2W / 4W E&M, Type II and Type V
A-law, 8 bit/sample, A=87.6 / 87.7, 13 segment coding
Fully compliant to ITU (CCITT) G.712 specification
600 Ohms (900 Ohms optional)
300Hz-3400Hz
-2.0 dB Nominal (user adjustable)
Adjustable range 30 dB to +7 dB in steps of 0.5 dB
0 dB to 18 dB
≤-65dB
300Hz - 600Hz - ≥ 12 dB
600Hz - 3400Hz - ≥ 15 dB
≥ 46 dB between 300Hz to 3400Hz
50 pps - Pulse Dialing ≤ ± 2 ms / DTMF Dialing
1200 Ohms
< 5 mA
< 100mA
64Kbps Data Interface (Part No. VCL-MX-1545-04-48)
Number of interfaces per card
Maximum number of interface cards
Mode - Synchronous - Interface
Mode - Asynchronous - Interface
Mode - Sub Rate Multiplexing Conformity
Synchronous Bit rate
Asynchronous Bit rate
4
9
V.35 / V.36 / X.21 / RS530 / V.24 / V.11 / V.28 - DCE
RS232 / RS485 / V.24 / V.11 / V.28 - DCE
RS232 / RS485 / V.24 / V.11 / V.28 - 4 Asynchronous
data channels multiplexed into one 64 Kbps timeslot - DCE
EIA and ITU-T
V.35 / V.36 / X.21 / RS530 / V.11 @ 64 Kbps
V.24 @ 300, 600, 1200, 2400, 4800, 9600, 19200 bps
50 bps to 19200 bps
G.703 @ 64Kbps, Synchronous Data Interface: (Part No. VCL-MX-1560-08-5.0)
Interfaces
Number of interfaces per card
Maximum number of interface cards
Conformity
Mode
Bit rate
G.703 @ 64Kbps
8
9
To (CCITT) Rec. G.703
Synchronous, Co-directional
64 Kbps
Copyright: Valiant Communications Limited - 2016
23
Technical Specifications
VCL-MX Version 6 - E1 Multiplexer
Relay I/O Interface Card: (Part No. VCL-MX-1547-16-48)
Description: This interface card provides 8 Relay I/Os that may be used to extend either Dry Relay
Contacts (Relay Normally-Open or Relay Normally-Close) or operate switches remotely (using Dry
Relay Contacts rated 1A @ 60Volts DC) between any two multiplexers using a 64 Kbps time-slot.
Maximum number of channels
Maximum number of interface cards
72 / 144
9
Relay Specifications (Drivers)
Maximum switching power
Maximum switching voltage / current
Isolation
Typical number of operations
60 W (approximately)
60V DC, 1 A
250V AC, 1 A
2.5 KVA Minimum
> 1 million
Dry Contacts Sensors
Maximum number of dry contact sensors
Maximum current
Typical current
Reference source voltage
8
50 mA
20 mA
3.3 Volts
Universal Data Interface: High Speed Synchronous “n x 64” Data Interface Type
User Configurable DCE-DTE: (Part No. VCL-MX-1558-04-48)
Interface
Number of interfaces per card
Maximum number of interface cards
Bandwidth
Conformity
Mode
Bit rate
User interface
V.35 (DTE/DCE)
V.36 (DTE/DCE)
X.21 (DTE/DCE)
V.11 (DTE/DCE)
RS422 (DTE/DCE)
RS530 (DTE/DCE)
4, (“N” x 64KBits/sec. per card)
9
(“N” x 64 Kbits/sec. Interface
Maximum value of “N” =30) - user selectable
Universal user-configurable as above
Synchronous
64 Kbps to 1920 Kbps
DCE/DTE (User programmable for DTE/DCE mode)
Copyright: Valiant Communications Limited - 2016
24
Technical Specifications
VCL-MX Version 6 - E1 Multiplexer
Integrated IEEE C37.94 Teleprotection Interface (Part No. VCL-MX-1552)
Number of ports
Standards
Optical
Optical connector
Safety
4
IEEE C37.94
850nm Multi Mode (2KM)
1310nm Multi Mode (2KM)
1310nm Single Mode (40KM / 80KM / 120KM)
FC / PC
Class 1 Laser
8 E1 Plus 100Mbps Ethernet Fiber Optical Transport Interface (Part No. VCL-MX-1551-5.0)
Optical
Number of optical ports
Channel capacity
Jitter character
Type of transmitter
Transmitter power
1+1 redundant, automatic link protection
8E1 Plus 100Mbps Ethernet
ITU-T G.742, G.823 compliant
Class 1 Laser
-11 dBm to +3 dBm - as ordered
20 km, 40 km, 80 km, 120 km reach as ordered
Receive sensitivity
- 34 dBm
Bit rate
155 Mbps
Wavelength
850 nm multimode / 1310nm single mode / 1550nm
single mode (optional)
Optical connector
LC (MSA Compliant SFP Module)
Fully compliant with ITU-T G.957, G.958 Specification
Class 1 Laser Product, Compliant with IEC 60825-1
Compliant with Telcordia (Bellcore) GR-468-CORE
Safety
Class 1 Laser
Auto Laser Shut Down in the event of fiber break.
Ethernet Interface - 10/100BaseT
Number of interfaces
4
Interface
RJ-45 Ethernet 10BaseT or 100BaseT-TX (auto sensing)
Compliance
Ethernet Version 2.0 IEEE802.3
10Base-T & 100Base-TX Activity, Full/half duplex.
Interface Rate
100 Mbps Ethernet data transmission rate
Order Wire Interface
Phone set
Standard 2-wire phone set
Bandwidth and coding
64 Kb/s PCM Channel, A-Law Coding
Environmental
Temperature
Humidity
Altitude
-10°C to + 60°C
90% R.H. (Non-condensing)
Upto 9,000 feet
Copyright: Valiant Communications Limited - 2016