DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC LUẬT / Content
Content
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC LUẬT
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC LUẬT
Philips - BGP322 T35 1xECO106-3S/657 DC (1xECO106-3S/657)................................................................................................................2
Street 1: Alternative 1
Planning results.................................................................................................................................................................................................... 4
Street 1: Alternative 1 / Sidewalk 1 (P4)
Isolines............................................................................................................................................................................................................. 6
Street 1: Alternative 1 / Roadway 3 (M4)
Isolines............................................................................................................................................................................................................. 7
Street 1: Alternative 1 / Roadway 2 (M4)
Isolines........................................................................................................................................................................................................... 12
Street 1: Alternative 1 / Sidewalk 2 (P4)
Isolines........................................................................................................................................................................................................... 17
Page 1
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Philips BGP322 T35 1xECO106-3S/657 DC 1xECO106-3S/657 / Philips - BGP322 T35 1xECO106-3S/657 DC (1xECO106-3S/657)
Philips BGP322 T35 1xECO106-3S/657 DC 1xECO106-3S/657
SpeedStar – LEDs ensure a safe journey home Municipalities are
under pressure to meet energy conservation goals by reducing their
energy consumption and carbon footprint while complying with lighting
norms and standards.
Our SpeedStar LED luminaire addresses these fundamental issues
and provides a solution to reduce the impact on our environment.
SpeedStar is an energy-efficient luminaire requiring minimal
maintenance and incorporating the easy-to-upgrade LEDGINE, which
can be connected to lighting regulation systems for further energy
savings. This carbon-neutral luminaire is the ideal solution for
functional road and street lighting.
Light output ratio: 95.69%
Lamp luminous flux: 11100 lm
Luminaire luminous flux: 10622 lm
Power: 90.0 W
Luminous efficacy: 118.0 lm/W
Luminous emittance 1 / Polar LDC
105°
105°
90°
90°
75°
75°
200
60°
60°
300
400
45°
45°
500
600
30°
15°
cd/klm
C0 - C180
0°
15°
30°
η = 96%
C90 - C270
Page 2
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Philips BGP322 T35 1xECO106-3S/657 DC 1xECO106-3S/657 / Philips - BGP322 T35 1xECO106-3S/657 DC (1xECO106-3S/657)
Luminous emittance 1 / Linear LDC
400
320
240
160
80
90.0°
67.5°
45.0°
22.5°
0.0°
22.5°
45.0°
cd/klm
C0 - C180
67.5°
90.0°
η = 96%
C90 - C270
Luminous emittance 1 / Luminance diagram
C225
C180
C270
C135
C90
80000
120000
160000
200000
240000
C315
C0
C45
cd/m²
g = 65.0°
g = 75.0°
g = 85.0°
Page 3
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Planning results
Street 1 according to EN 13201:2015
Sidewalk 1 (P4), 150.00 m²
Philips BGP322 T35 1xECO106-3S/657 DC
5.00 m
Roadway 3 (M4), 337.50 m²
Tarmac: CIE R3, q0: 0.070
11.25 m
The pole distance of this luminaire arrangement determines the length of the valuation
fields.
Median 1
2.50 m
Lamp:
1xECO106-3S/657
Luminous flux (luminaire):
10621.66 lm
Luminous flux (lamp):
11100.00 lm
Operating Hours
Roadway 2 (M4), 337.50 m²
Tarmac: CIE R3, q0: 0.070
11.25 m
4000 h:
100.0 %, 90.0 W
W/km:
2970.0
Arrangement:
Median
Pole distance:
30.000 m
Boom inclination (3):
5.0°
Boom length (4):
1.494 m
Light centre height (1):
12.000 m
Light overhang (2):
0.250 m
ULR:
0.00
ULOR:
0.00
Maximum luminous intensities
Sidewalk 2 (P4), 150.00 m²
30.00 m
5.00 m
at 70° and above
538 cd/klm *
at 80° and above
36.1 cd/klm *
at 90° and above
1.30 cd/klm *
Luminous intensity class:
G*3
Any direction forming the specified angle from the downward
vertical, with the luminaire installed for use.
* Luminous intensity values in [cd/klm] for calculating luminous
intensity class refer to the output flux of the luminaire, according
EN 13201:2015.
Arrangement complies with glare index class D.4
Page 4
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Planning results
Results for valuation fields
Philips BGP322 T35 1xECO106-3S/657 DC
Light loss factor: 0.90
Sidewalk 1 (P4)
Em [lx]
≥ 8.00
≤ 12.00
Emin [lx]
≥ 5.00
8.82
6.10
Roadway 3 (M4)
Lm [cd/m²]
≥ 1.00
Uo
≥ 0.40
Ul
≥ 0.60
TI [%]
≤ 10
EIR
≥ 0.50
1.02
0.54
0.91
6
0.60
Lm [cd/m²]
≥ 1.00
Uo
≥ 0.40
Ul
≥ 0.60
TI [%]
≤ 10
EIR
≥ 0.50
1.09
0.58
0.90
5
0.54
Roadway 2 (M4)
Sidewalk 2 (P4)
Em [lx]
≥ 8.00
≤ 12.00
Emin [lx]
≥ 5.00
10.63
7.84
Results for energy efficiency indicators
Power density indicator (Dp)
0.006 W/lxm²
Lamp:
1xECO106-3S/657
Luminous flux (luminaire):
10621.66 lm
Luminous flux (lamp):
11100.00 lm
EN 13201:2015-5 does not include the case for planning with multiple luminaire
arrangements. The calculation of the output values is done therefore only for the
luminaire arrangement whose pole distance determines the length of the
valuation fields.
Operating Hours
Energy consumption density
Arrangement 1: BGP322 T35 1xECO106-3S/657 DC (360.0 0.4 kWh/m² yr
kWh/yr)
Arrangement 2: BGP322 T35 1xECO106-3S/657 DC (360.0 0.4 kWh/m² yr
kWh/yr)
4000 h:
100.0 %, 90.0 W
W/km:
2970.0
Arrangement:
Median
Pole distance:
30.000 m
Boom inclination (3):
5.0°
Boom length (4):
2.749 m
Light centre height (1):
12.000 m
Light overhang (2):
1.500 m
ULR:
0.00
ULOR:
0.00
Maximum luminous intensities
at 70° and above
538 cd/klm *
at 80° and above
36.1 cd/klm *
at 90° and above
1.30 cd/klm *
Luminous intensity class:
G*3
Any direction forming the specified angle from the downward
vertical, with the luminaire installed for use.
* Luminous intensity values in [cd/klm] for calculating luminous
intensity class refer to the output flux of the luminaire, according
EN 13201:2015.
Arrangement complies with glare index class D.6
Page 5
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Sidewalk 1 (P4) / Isolines
Sidewalk 1 (P4)
Light loss factor: 0.90
Grid: 10 x 4 Points
Em [lx]
≥ 8.00
≤ 12.00
Emin [lx]
≥ 5.00
8.82
6.10
Horizontal illuminance
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 6
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 3 (M4) / Isolines
Roadway 3 (M4)
Light loss factor: 0.90
Grid: 10 x 6 Points
Lm [cd/m²]
≥ 1.00
Uo
≥ 0.40
Ul
≥ 0.60
TI [%]
≤ 10
EIR
≥ 0.50
1.02
0.54
0.91
6
0.60
Horizontal illuminance
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 7
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 3 (M4) / Isolines
Observer 1
Luminance with dry roadway
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 8
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 3 (M4) / Isolines
Luminance with new lamp
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 9
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 3 (M4) / Isolines
Observer 2
Luminance with dry roadway
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 10
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 3 (M4) / Isolines
Luminance with new lamp
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 11
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 2 (M4) / Isolines
Roadway 2 (M4)
Light loss factor: 0.90
Grid: 10 x 6 Points
Lm [cd/m²]
≥ 1.00
Uo
≥ 0.40
Ul
≥ 0.60
TI [%]
≤ 10
EIR
≥ 0.50
1.09
0.58
0.90
5
0.54
Horizontal illuminance
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 12
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 2 (M4) / Isolines
Observer 1
Luminance with dry roadway
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 13
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 2 (M4) / Isolines
Luminance with new lamp
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 14
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 2 (M4) / Isolines
Observer 2
Luminance with dry roadway
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 15
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Roadway 2 (M4) / Isolines
Luminance with new lamp
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 16
DỰ ÁN: XÂY DƯNG ĐƯỜNG NỐI ĐẠI HỌC
LUẬT
9/16/2019
Street 1: Alternative 1 / Sidewalk 2 (P4) / Isolines
Sidewalk 2 (P4)
Light loss factor: 0.90
Grid: 10 x 4 Points
Em [lx]
≥ 8.00
≤ 12.00
Emin [lx]
≥ 5.00
10.63
7.84
Horizontal illuminance
5.00 m
11.25 m
2.50 m
11.25 m
5.00 m
30.00 m
Page 17