In/Outdoor Dry Loose Tube Cables: Riser and Plenum
ADC’s innovative line of indoor/outdoor loose tube cables are designed to meet all the rigors
of the outside plant environment and have the necessary fire ratings to be installed inside the
building. These cables eliminate the messy gel filler of traditional loose tube style cables with
super absorbent polymers. The installer can place the cable anywhere in the network, bypassing
the transition points required in most installations. Cables are available with fiber counts from
2 to 144.
Features:
• Dry cable core and dry buffer tubes provide
effective water blocking without the need
for traditional gel filler
• Can be placed anywhere in the network,
bypassing transition points from outdoor to
indoor
• Installation times reduced because there is
no need to clean gels
• Excellent flame retardancy
• Flexible design for easy installation
• Color-coded buffer tubes and fibers
• Wide operating temperature range:

-40° to 75 °C (-40° to 167 °F)
Applications:
• Between buildings in campus
backbone cabling
• Riser or plenum rated environments


• Outside plant
Compliances:
• Telcordia GR-20-CORE
• Telcordia GR-409-CORE
• EIA/TIA FOTPs
• ETL, (UL) 910, NEC OFNP, FT-6
• ETL, (UL) 1666, NEC OFNR, FT-4
• ISO/IEC 11801
• EIA/TIA 568-B
• ANSI/ICEA S-104-696
2 / 0 7 • 1 0 3 9 3 6 A E
In/Outdoor DLT Cables: Riser and Plenum
TrueNet
®
Fiber Optic Cable
In/Outdoor Dry Loose Tube Cables: Riser and Plenum
2
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Specifications
12 FIBER CABLE
250 µm UV Colored
Optical Fiber
3.0 mm Thermoplastic
Tube Drygel Water
Blocked
Strength Member
Flame Retardant Inner
and Outer Jacket
144 FIBER CABLE
250 µm UV Colored

Optical Fiber
3.0 mm Thermoplastic
Tube Drygel Water
Blocked
Central Strength
Members
Strength Member
Flame Retardant Inner
and Outer Jacket
ENVIRONMENTAL CHARACTERISTICS
Storage Temperature: -40° to 85 °C (-40° to 180 °F)
Operating Temperature:
-40° to 75 °C (-40° to 167 °F)
Installation Temperature:
0° to 60 °C (-32° to 140 °F)
MECHANICAL CHARACTERISTICS
Riser: Fiber Count
2-12 18-24 36-48 60-72 84 96 108 120 132 144
Maximum Tensile Load N (ibf)
Short Term (install):
Long Term:
1335 (300)
400 (90)
1335 (300)
400 (90)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)

890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
Minimum Bend Radius cm (in)
Short Term (install):
Long Term:
9.7 (3.8)
6.5 (2.6)
18.9 (7.4)
12.6 (5.0)
15.1 (5.9)
10.1 (4.0)
17.8 (7.0)
11.9 (4.7)
19.4 (7.7)
13.0 (5.1)
20.6 (8.1)
13.7 (5.4)
22.5 (8.9)
15.0 (5.9)
24.2 (9.5)
16.2 (6.4)

25.6 (10.1)
17.1 (6.7)
27.2 (10.7)
18.1 (7.1)
Plenum: Fiber Count
2-12 18-24 36-48 60-72 84 96 108 120 132 144
Maximum Tensile Load N (ibf)
Short Term (install):
Long Term:
1335 (300)
400 (90)
1335 (300)
400 (90)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
2670 (600)
890 (200)
Minimum Bend Radius cm (in)

Short Term (install):
Long Term:
9.9 (3.9)
6.6 (2.6)
18.9 (7.4)
12.6 (5.0)
14.1 (5.6)
9.4 (3.7)
17.5 (6.9)
11.7 (4.6)
18.5 (7.3)
12.3 (4.9)
20.0 (7.9)
13.4 (5.3)
21.6 (8.5)
14.4 (5.7)
23.1 (9.1)
15.4 (6.1)
24.7 (9.7)
16.5 (6.5)
26.4 (10.4)
17.6 (6.9)

2 / 0 7 • 1 0 3 9 3 6 A E
In/Outdoor DLT Cables: Riser and Plenum
TrueNet
®
Fiber Optic Cable
In/Outdoor Dry Loose Tube Cables: Riser and Plenum
3

w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
OPTICAL PERFORMANCE Maximum
Attenuation (dB/km)
Typical Attenuation
(dB/km)
Bandwidth
1

(MHz/km)
ISO/IEC
Type
Multimode
850 nm/1300 nm 850 nm/1300 nm 850 nm/1300 nm
62.5/125
3.5/1.5 3.0/1.0 200/500 OM1
50/125
3.5/1.5 3.0/1.0 500/500 OM2
50/125 laser optimized
to 150 meters

3.5/1.5

3.0/1.0
500/500 OM2
50/125 laser optimized
to 300 meters

3.5/1.5

3.0/1.0

1500/500
2
OM3
50/125 laser optimized
to 550 meters

3.5/1.5

3.0/1.0
4700
2
/500
1
OM3
1310 nm/1550 nm 1310 nm/1550 nm 1310 nm/1550 nm
Singlemode
1.0/1.0 0.4/0.3 N/A OS1
1
Bandwidth measurements specified overfilled launch conditions (OFL)
2
Bandwidth measurements specified by laser launch
TRANSMISSION PERFORMANCE—
Guaranteed Minimum Link Lengths
Gigabit Ethernet
Link Length (SX/LX)
10 Gigabit Ethernet
Link Length (SR/LX4)
3
Jacket
Color

Multimode
62.5/125
300 m/550 m 35 m/300 m Orange
50/125
750 m/500 m 150 m/300 m Orange
50/125 Ultra laser optimized to 300 meters
900 m/550 m 300 m/300 m Aqua
50/125 Ultra laser optimized to 550 meters
900 m/550 m 550 m/550 m Aqua
(LR/ER)
Singlemode
NA/5000 m 10 km/40 km Yellow
3
10 Gigabit Ethernet distance guarantees at the long wavelength are achieved via four 3.125 Gbps channels
multiplexed with WWDM technology.
PREMIER INFRASTRUCTURE SOLUTIONS
Spec Sheet
Web Site: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our Web site.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
103936AE 2/07 Revision © 2006, 2007 ADC Telecommunications, Inc. All Rights Reserved
Cable Type Fibers
Diameter Weight
Catalog Number*

mm in kg/km lb/1000
1
Dry loose tube:
indoor/outdoor,
Riser
2-12 6.6 0.26 48 32 QXXXDLTIORYYY
18-36 10.4 0.41 133 77
48-60 11.5 0.45 110 74
72 12.4 0.49 156 105
84 13.3 0.52 171 115
96 14.3 0.56 206 138
108 15.2 0.60 229 154
120 16.2 0.64 261 175
132 17.2 0.68 295 198
144 18.2 0.72 337 226
Dry loose tube:
indoor/outdoor,
Plenum
2-12 6.6 0.26 48 32 QXXXDLTIOPYYY
18-72 11.7 0.46 130 87
84 12.6 0.50 138 96
96 13.6 .54 163 110
108 14.6 0.57 192 129
120 15.7 0.62 223 150
132 16.6 0.66 257 172
144 17.6 0.70 294 197
*Replace XXX with fiber count, i.e. 2 fibers = 002"
*Replace YYY with fiber type:
010 = Singlemode
062 = 62.5/125 µm multimode

50E = 50/125 µm multimode/orange jacket
50A = 50/125 µm multimode laser optimized to 150 meters/aqua jacket
50U = 50/125 µm multimode laser optimized to 300 meters
5U5 = 50/125 µm multimode laser optimized to 550 meters