Fiber Optic Cable
Two-Fiber LCF

Distribution Cable: Plenum and Riser
SPEC SHEET
www.adc.com • +1-952-938-8080 • 1-800-366-3891
ADC’s Two-Fiber LCF

Distribution Cable is
easy to strip and optimized for standard single
fiber and duplex connectors. It can withstand
installation through tight bend radii in
backbone applications.
Features:
• Utilizes 245/900 µm PVC buffer
• Flame retardant PVC jacket
• Rugged construction
Applications:
• Backbone and Fiber-To-The-Desk (FTTD)
drop cabling
• Communications closet patch cord
assemblies
Compliances:
• Heavy metal/lead free cable independently
verified to comply with current worldwide
environmental demands
• Restriction of the Use of Hazardous
Substances (RoHS) (2002/95/EC)
• State of California Safe Drinking and Toxic
Enforcement Act of 1986 (Proposition 65)
• ISO/IEC 11801, IEC 60794-2, Optical Fiber


Cables-Part 2
• Telcordia GR-409-CORE, EIA/TIA FOTPs
• TIA/EIA 568-B
• (UL) 910, NEC OFNP, FT-6
• (UL) 1666, NEC OFNR, FT-4
8/05 • 1331199
Two-Fiber LCF

Dist. Cables: Plenum & Riser
Fiber Optic Cable
Two-Fiber LCF

Distribution Cable: Plenum and Riser
2
www.adc.com • +1-952-938-8080 • 1-800-366-3891
ENVIRONMENTAL CHARACTERISTICS: PLENUM
Storage Temperature -40˚ to 70 ˚C (-40˚ to 158 ˚F)
Operating Temperature 0˚ to 70 ˚C (32˚ to 158 ˚F)
Installation Temperature 0˚ to 70 ˚C (32˚ to 158 ˚F)
Specifications
4.5 mm Riser PVC
Outer Jacket
900
µm
PVC Tight Buffer
245
µm Acrylate Coated Optical Fiber
* Singlemode cable shown
with yellow jacket
Aramid Yarn

Strength Member
TWO-FIBER CABLE
ENVIRONMENTAL CHARACTERISTICS: RISER
Storage Temperature -40˚ to 70 ˚C (-40˚ to 158 ˚F)
Operating Temperature -20˚ to 70 ˚C (-4˚ to 158 ˚F)
Installation Temperature 0˚ to 70 ˚C (32˚ to 158 ˚F)
Fibers 2
Maximum Tensile Load N(lbf)
Short Term (install)
1800 (400)
Long Term
300 (67)
Minimum Bend Radius cm (in)
Installed
4.5 (1.77)
Loaded
9.0 (3.54)
MECHANICAL CHARACTERISTICS:
Fiber Optic Cable
Two-Fiber LCF

Distribution Cable: Plenum and Riser
3
www.adc.com • +1-952-938-8080 • 1-800-366-3891
TRANSMISSION PERFORMANCE—Guaranteed Minimum Link Lengths:
3
10 Gigabit Ethernet distance guarantees at the long wavelength are achieved
via four 3.125 Gbps channels multiplexed with WWDM technology
Gigabit Ethernet
Link Length (SX/LX)

10 Gigabit Ethernet
Link Length (SR/LX4)
3
Multimode
62.5/125 300 m/550 m 35 m/300 m
62.5/125 Enhanced 500 m/1000 m 65 m/300 m
50/125 550 m/550 m 86 m/300 m
50/125 Enhanced 750 m/2000 m 110 m/300 m
50/125 Ultra 300 900 m/550 m 300 m/300 m
50/125 Ultra 550 1040 m/550 m 550 m/300 m
1
(LR/ER)
Singlemode NA/5000 m 10 km/40 km
1
Bandwidth measurements specified overfilled launch conditions (OFL)
2
Bandwidth measurements specified by laser launch
Maximum Attenuation
(dB/km)
Typical Attenuation
(dB/km)
Bandwidth
1
(MHz/km)
850 nm/1300 nm 850 nm/1300 nm 850 nm/1300 nm
Multimode
62.5/125 3.5/1.5 2.7/0.8 200/500
62.5/125 Enhanced 3.5/1.5 2.7/0.8 200/500
50/125 3.5/1.5 2.7/0.8 500/500
50/125 Enhanced 3.5/1.5 2.7/0.9 500/500

50/125 Ultra 300 3.5/1.5 2.7/0.9 2000/500
2
50/125 Ultra 550 3.5/1.5 2.7/0.9 4700
2
/500
1
1310 nm/1550 nm 1310 nm/1550 nm 1310 nm/1550 nm
Singlemode 1.0/1.0 0.4/0.3 N/A
OPTICAL PERFORMANCE:
8/05 • 1331199
Two-Fiber LCF

Dist. Cables: Plenum & Riser
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you
may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications,
Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or
features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
1331199 8/05 Original © 2005 ADC Telecommunications, Inc. All Rights Reserved
Web Site: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our web site.
SPEC SHEET
*Replace YYY with fiber type:
010 = Singlemode 050 = 50/125 µm Multimode
062 = 62.5/125 µm Multimode 50E = 50/125 µm Enhanced Multimode
62E = 62.5/125 µm Enhanced Multimode 50U = 50/125 µm Ultra Multimode for 300 m 10 Gbps
5U5 = 50/125 µm Ultra Multimode for 550 m 10 Gbps
Ordering Information

Cable Type Fibers Diameter mm (in) Catalog Number*
Plenum Duplex 2 4.5 (0.18) 6002LFPFDDYYY
Riser Duplex 2 4.5 (0.18) 6002LFRFDDYYY
RESULTS OF INDEPENDENT LABORATORY TESTING:
Sample Element Method
Results
(PPM)
Zipcord, cross-section
Lead
(Pb)
EN 1122:2001 (dissolution)
and CAP-046A (ICP-AES)
<300
Zipcord, cross-section
Cadmium
(Cd)
EN 1122:2001 (dissolution)
and CAP-046A (ICP-AES)
<5
Zipcord, cross-section
Chromium
(Cr)
EN 1122:2001 (dissolution)
and CAP-046A (ICP-AES)
<1
Zipcord, cross-section
Mercury
(Hg)
EN 1122:2001 (dissolution)
and CAP-046A (ICP-AES)

<5
Zipcord, cross-section
Hexavalent
Chromium
(Cr(VI))
GMW 3034, modified to allow
determination of a Hexavalent
Chromium value through
calibration of the UV-VIS
spectrophotometer.
0

×