Tải bản đầy đủ (.pdf) (18 trang)

Tài liệu ADC KRONE - Catalogue - FO - Fiber Optic Raceway System - Complete doc

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (620.45 KB, 18 trang )

3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
293
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems

Fiber Cable Raceway Systems
Introduction 294
Features and Benefits 295
FiberGuide
®
Fiber Management System 296
Plenum FiberGuide
®
System 304
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
294
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
The Industry’s Most Comprehensive Optical Raceway System
ADC’s FiberGuide
®
Fiber Management Systems offer the greatest breadth of optical raceway products in
the industry. In response to customer requirements, ADC continues to innovate and improve FiberGuide
Systems, adding greater flexibility and driving down installation time to ensure a smooth deployment.
FiberGuide is a raceway system designed to protect and route fiber optic patch cords, multi-fiber cable


assemblies and intrafacility fiber cable (IFC) to and from fiber splice enclosures, fiber distribution frames
and fiber optic terminal devices. FiberGuide ensures a two-inch minimum bend radius is maintained
throughout the system. And new tool-less, SnapFit

junctions, cover options and Plenum Express Exit


drops significantly reduce the amount of time required for installation.
The FiberGuide system is a complete set of products designed and manufactured to ensure total off-frame
protection and ease of use. Basic components include horizontal and vertical straight sections, horizontal
and vertical elbows, downspouts, junctions and numerous support hardware and flex-tube kits.
Available in a variety of sizes:
2x2 — Ideal for smaller installations or for vertical routing of a
maximum of four hundred 2mm fiberoptic patch cords. All 2x2
FiberGuide products are shipped with covers.
2x6 — Designed for height-restricted environments, this robust
system provides the same support and system flexibility of the
traditional 4-inch high system while saving 2 inches of overhead
space. It features a maximum capacity of 1,200, 2mm patch cords.
4x4 — Features the maximum capacity to support 1,600, 2mm
patch cords. It has been engineered to allow straight sections to be
self-supporting over a span of up to 6 feet (1.83m).
4x6 — Features the same benefits of the 4-inch system and a
maximum trough capacity of 2,400, 2mm patch cords.
4x12 — The largest system in the FiberGuide family, this 12-inch
wide trough has a maximum capacity to support nearly 5,000,
2mm patch cords. Perfect for runs over fiber frame lineups and
perimeter routes.
Fiber Cable Raceway Systems
Introduction

3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
295
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Features and Benefits
Speed of Installation
FiberGuide
®
systems feature a variety of products that allow for quick and easy installation. Express Exit


drops as well as tool-less products including Snap-Fit

junctions, snap-on covers and new hinged cover
options save valuable time for installers.
Speed of Deployment
The Express Exit system enables new drops to be added or removed quickly and easily. A drop can be added
into a fully loaded raceway in seconds—without cutting.
Raceway Flexibility
FiberGuide features 38 support structures, over 75 fittings, multiple drop options and several other
components to suit any application you create.
Fiber Protection
ADC’s broadband expertise translates into maximum protection for your network. Two inch minimum bend
radius is maintained throughout the system regardless of the raceway size.
Strength and Durability
100% raceway reliability—stands up to any challenge.
Fiber Cable Raceway Systems

Features and Benefits
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
296
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
FiberGuide
®
Fiber Management System
Recommended capacity takes into consideration random jumper placement into the FiberGuide
®

system. Maximum density refers to the maximum number of fiber jumpers in a given cross-section
of a FiberGuide installation.
2.0mm
Patch Cords
102
3.0mm
Patch Cords
44
1.7mm
Patch Cords
Maximum
Patch Cord
Density (per in
2
)

142
ADC Recommended Density
Maximum Density
Recommended
Patch Cord
Density (per in
2
)
2.0mm
Patch Cords
90
3.0mm
Patch Cords
40
1.7mm
Patch Cords
120
2-inch
3-inch
4-inch
Trough
Pileup
1080
1620
2160
480
720
960
720
1080

1440
320
480
640
2x2
FiberGuide System
360
-
-
160
-
-
3.0
mm
2.0
mm
4x4
FiberGuide System
4x6
FiberGuide System
480
-
-
1.7
mm
3.0
mm
2.0
mm
960

1440
1920
1.7
mm
3.0
mm
2.0
mm
1440
2160
2880
1.7
mm
4x12
FiberGuide System
2160
3240
4320
960
1440
1920
3.0
mm
2.0
mm
2880
4320
5760
1.7
mm

2x6
FiberGuide System
1080
-
-
480
-
-
3.0
mm
2.0
mm
1440
-
-
1.7
mm
2-inch
3-inch
4-inch
Trough
Pileup
1224
1836
2448
528
792
1056
816
1224

1632
352
528
704
408
-
-
176
-
-
3.0
mm
2.0
mm
4x4
FiberGuide System
4x6
FiberGuide System
568
-
-
3.0
mm
2.0
mm
1136
1704
2272
1.7
mm

3.0
mm
2.0
mm
1704
2556
3408
1.7
mm
4x12
FiberGuide System
2448
3672
4896
1056
1584
2112
3.0
mm
2.0
mm
3408
5112
6816
1.7
mm
2x2
FiberGuide System
1.7
mm

1224
-
-
528
-
-
3.0
mm
2.0
mm
1704
-
-
2x6
FiberGuide System
1.7
mm
Patch Cord Densities
2-inch
3-inch
4-inch
Trough
Pileup
780
1170
1560
520
780
1040
260

-
-
4x4
FiberGuide System
4x6
FiberGuide System
4x12
FiberGuide System
1560
2340
3120
2x2
FiberGuide System
780
-
-
2x6
FiberGuide System
TracerLight

Patch Cords—65 Patch Cords per in
2
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
297
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems

FiberGuide
®
Fiber Management System
Express Exits

Units (For use with 2x6, 4x4, 4x6 and 4x12 systems)
Description
2-inch Express Exit Unit
4-inch Express Exit base with base cover
4-inch Express Exit rear cover kit
Rear cover, 4-inch Express Exit—4x4 system
Rear cover, 4-inch Express Exit—4x6 system
Rear cover, 4-inch Express Exit—4x12 system
Low profile Express Exit
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MEXP-A/B/F
FGS-MEXP-E-A/B/F
FGS-MEXC-E-A/B/F
FGS-MEXC-E-A
FGS-MEXC-E-B
FGS-MEXC-E-F
FGS-MEXP-LP-A/B/F
2x2 Fittings and Junctions
Description
2x2 horizontal cross with cover
2x2 horizontal tee with cover
2x2 45º horizontal elbow with cover
2x2 90º horizontal elbow with cover

2x2 to 4-inch straight adapter with cover
2x2 end cap kit (includes junction)
2x2 45º up elbow with cover
2x2 45º down elbow with cover
2x2 90º up elbow with cover
2x2 90º down elbow with cover
2x2 junction
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MHXP-C
FGS-MHTA-C
FGS-MH4A-C
FGS-MH9A-C
FGS-MDSA-AC
FGS-HMEC-C
FGS-MU4A-C
FGS-MD4A-C
FGS-MU9A-C
FGS-MD9A-C
FGS-MJWR-C
2x2 Downspout Options
Description
2x2 standard downspout with cover
2x2 extended downspout with cover
2x2 flex tube attachment with 5-foot length
2-inch flex tube and 2x2 junction

2x2 extended downspout kit with 2-foot length
2-inch flex tube and cover


Dual
7
/
8
-inch flex tube attachment with
(2) 5-foot lengths flex tube and 2x2 junction

Kit of 10
7
/
8
-inch flex tube clamps
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MSDS-C
FGS-MDSP-C
FGS-MEX1-C-5F

FGS-KDH2-C

FGS-KT03-C

FGS-HSHC-10
2x2 Straight Section
Description
6-foot horizontal straight with cover
O r d e r i n g I n f o r m a t i o n
Catalog Number


FGS-MSHA-C
Express Exits
FGS-MSDS-C
FGS-MHTA-C
FGS-MSHA-C
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
298
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
FiberGuide
®
Fiber Management System
2x6 Straight Section
Description
2x6 horizontal straight section (6-feet)
2x6 horizontal straight section snap-on cover (6-feet)
2x6 horizontal straight section hinged cover
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MSHS-G
FGS-MSSC-B/G
FGS-MSNC-B/G
2x6 Fittings
Description

2x6 to 2x2 downspout
2x6 horizontal T
2x6 horizontal cross
2x6 90º horizontal elbow
2x6 90º down elbow
2x6 45º horizontal elbow
2x6 45º up elbow with cover
2x6 45º down elbow
2x6 to 4x4 adapter
2x6 to 4x6 adapter
2x6 trumpet flare
2x6 end cap
2x6 Express Exit
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MDSP-G
FGS-MHRT-G
FGS-MHXP-G
FGS-MH9E-G
FGS-MD9E-G
FGS-MH4E-G
FGS-MU4E-G
FGS-MD4E-G
FGS-MDSA-GA
FGS-MDSA-GB
FGS-MTRM-G
FGS-HMEC-G
FGS-MEXP-LP-G
2x2 Direct Support Kits

Description
2x2 ladder rack support kit
2x2 bay top short L bracket kit
2x2 bay top long L bracket kit
2x2 digital cableway support kit
2x2 underfloor support kit
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-HLR2-C
FGS-BTBS-C
FGS-BTBL-C
FGS-HDCB-C
FGS-HUFB-C
FGS-HLR2-C
2x2 Track Support Kits
Description
Aluminum track support (6-feet)
New threaded rod kit (
5
/
8
-inch)
New threaded rod kit (
1
/
2
-inch)
Track connecting bar kit
Ladder rack bracket kit (

5
/
8
-inch)
Threaded rod 12" long
Dual threaded rod bracket kit
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-HASK-C
FGS-HTR2-5/8
FGS-HTR2-1/2
FGS-HAEJ-C
FGS-HLDR-5/8
FGS-HTHR-5/8-12
FGS-HTUB-2-AB
FGS-HASK-C
FGS-MSHS-G
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
299
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
FiberGuide
®
Fiber Management System
2x6 Junction

Description
2x6 junction
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-JUNC-G
FGS-JUNC-G
4x4 Fittings and Junctions
Description
4x4 downspout
4x4 and 4x6 downspout cover
4x4 extended downspout
4x4 and 4x6 extended downspout cover
4x4 horizontal T
4x4 horizontal T cover
4x4 horizontal cross
4x4 horizontal cross cover
4x4 90º horizontal elbow
4x4 90º horizontal elbow cover
4x4 45º horizontal elbow
4x4 45º horizontal elbow cover
4x4 90º up elbow with cover
4x4 90º down elbow
4x4 90º down elbow cover
4x4 45º up elbow with cover
4x4 45º down elbow
4x4 45º down elbow cover
4x4 to 4x6 straight adapter
4x4 to 4x6 straight adapter cover
4x4 end cap

4x4 snap-fit junction
4x4 cut-in T
Cut-in T fixture
4x4 IFC tie bracket
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MDSP-A
FGS-MCDS-AB
FGS-MDSP-EX-A
FGS-MCDS-EX-AB
FGS-MHRT-A
FGS-SHRT-A
FGS-MHXP-A
FGS-SHXP-A
FGS-MH9E-A
FGS-SH9E-A
FGS-MH4E-A
FGS-SH4E-A
FGS-MU9E-A
FGS-MD9E-A
FGS-SD9E-A
FGS-MU4E-A
FGS-MD4E-A
FGS-SD4E-A
FGS-MDSA-AB
FGS-SDSA-AB
FGS-HMEC-A
FGS-MFAW-A
FGS-MHIS-A

FGS-MHIS-JIG-A/B/F
FGS-HIFC-A
FGS-MDSP-A
4x4 Straight Section
Description
6-foot horizontal straight section
6-foot horizontal straight section hinged cover
4x4 expandable straight section
6-foot horizontal straight section snap-on cover
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MSHS-A
FGS-MSHC-A
FGS-MVAR-A
FGS-MSSC-A
FGS-MSHS-A
FGS-MH9E-A
FGS-MFAW-A
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
300
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
FiberGuide
®
Fiber Management System

4x4 and 4x6 Downspout Options
Description
4x4 downspout junction kit
2x2 flex tube attachment with 5-foot length
2-inch flex tube and 2x2 junction

4x4/4x6 downspout insert (adapts to 2x2 system)
4x4 trumpet flare kit
4-inch square to 2-inch round adapter with
5-feet flex tubing

4-inch square to 2-inch round adapter with
10-feet flex tubing

4-inch square to 2-inch round adapter with
15-feet flex tubing

4x4 single flex tube attachment with (1) 5-foot
length 2-inch flex tubing

4x4 dual flex tube attachment with (2) 5-foot
lengths 2-inch flex tubing
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MJWR-A
FGS-MEX1-C-5F

FGS-HDSI-AB
FGS-MTRM-A

FGS-ASRI-5F

FGS-ASRI-10F

FGS-ASRI-15F

FGS-KT03-A1

FGS-KT03-A
2x6, 4x4 and 4x6 Support Kits
Description
New threaded rod bracket (
5
/
8
-inch)
New threaded rod bracket (
1
/
2
-inch)
Modified new threaded rod bracket (
5
/
8
-inch)
Existing threaded rod bracket (
5
/
8

-inch)
Existing threaded rod bracket (
1
/
2
-inch)
Modified existing threaded rod bracket (
5
/
8
-inch)
Center support bracket (
5
/
8
-inch)
Center support bracket (
1
/
2
-inch)
L bay support bracket
Digital cableway bracket kit (12-inch)
Digital cableway bracket kit (15-inch)
Top support C-bracket
Top support low profile C-bracket
Ladder rack center support bracket kit
Threaded rod,
5
/

8
-11x12-inch
Threaded rod,
5
/
8
-11x30-inch
Threaded rod,
5
/
8
-11x72-inch
Auxiliary framing clip kit
5
/
8
-11 thread
Auxiliary framing clip kit
1
/
2
-11 thread
Adjacent angle support bracket
5
/
8
-11/36-inch
Adjacent angle support bracket
5
/

8
-11/48-inch
Adjacent angle support bracket
1
/
2
-13/36-inch
Adjacent angle support bracket
1
/
2
-13/48-inch
Ladder rack bracket kit (
5
/
8
-inch)
Unistrut nut kit (
5
/
8
-inch)
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-HNTR-5/8
FGS-HNTR-1/2
FGS-HNTR-5/8-A
FGS-HETR-5/8
FGS-HETR-1/2

FGS-HETR-5/8-A
FGS-HTUB-5/8
FGS-HTUB-1/2
FGS-HLBK
FGS-HCBL-12
FGS-HCBL-15
FGS-HNTS-5/8
FGS-HNTS-5/8-LP
FGS-HNLR-AB
FGS-HTHR-5/8-12
FGS-HTHR-5/8-30
FGS-HTHR-5/8-72
FGS-HFCK-5/8
FGS-HFCK-1/2
FGS-HASB-5/8-36
FGS-HASB-5/8-48
FGS-HASB-1/2-36
FGS-HASB-1/2-48
FGS-HLDR-5/8
FGS-HDGR
FGS-MDSP-EX-A
FGS-HNTR-XX
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
301
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems

FiberGuide
®
Fiber Management System
4x6 Fittings and Junctions
Description
4x6 downspout
4x4/4x6 downspout cover
4x6 extended downspout
4x4/4x6 extended downspout cover
4x6 horizontal T
4x6 horizontal T cover
4x6 horizontal cross
4x6 horizontal cross cover
4x6 90º horizontal elbow
4x6 90º horizontal elbow cover
4x6 45º horizontal elbow
4x6 45º horizontal elbow cover
4x6 45º up elbow with cover
4x6 45º down elbow
4x6 45º down elbow cover
4x6 90º down elbow
4x6 90º down elbow cover
4x6 90º up elbow with cover
4x6 cut-in T
Cut-in T fixture
4x6 trumpet flare kit
4x6 end cap
4x6 snap-fit junction
4x6 IFC tie bracket
O r d e r i n g I n f o r m a t i o n

Catalog Number

FGS-MDSP-B
FGS-MCDS-AB
FGS-MDSP-EX-B
FGS-MCDS-EX-AB**
FGS-MHRT-B
FGS-SHRT-B
FGS-MHXP-B
FGS-SHXP-B
FGS-MH9E-B
FGS-SH9E-B
FGS-MH4E-B
FGS-SH4E-B
FGS-MU4E-B
FGS-MD4E-B
FGS-SD4E-B
FGS-MD9E-B
FGS-SD9E-B
FGS-MU9E-B
FGS-MHIS-B
FGS-MHIS-JIG-A/B/F
FGS-MTRM-B
FGS-HMEC-B
FGS-MFAW-B
FGS-HIFC-B
4x6 Straight Section
Description
6-foot horizontal straight section
6-foot horizontal straight section hinged cover

4x6 expandable straight section
6-foot horizontal straight section snap-on cover
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MSHS-B
FGS-MSHC-B
FGS-MVAR-B
FGS-MSSC-B/G
FGS-MFAW-B
FGS-MDSP-B
FGS-MSHS-B
FGS-MU9E-B
** Dual downspout requires 2 covers
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
302
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
FiberGuide
®
Fiber Management System
4x12 Fittings
Description
4x12 horizontal T
4x12 to 4x6 horizontal T
4x12 horizontal cross

4x12 to 4x6 horizontal cross
4x12 to 4x6 adapter
4x12 90º horizontal elbow
4x12 45º horizontal elbow
4x12 end cap
4x12 cut-in T
Cut-in T fixture
4x12 45º up elbow with cover
4x12 45º down elbow
4x12 90º down elbow
4x12 trumpet flare kit
4x12 downspout with 4x6 exit
4x12 downspout with rear T
4x12 to dual 4x6 adapter
4x12 IFC tie bracket
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MHRT-F
FGS-MHRT-F/B
FGS-MHXP-F
FGS-MHXP-B/F
FGS-MDSA-FB
FGS-MH9E-F
FGS-MH4E-F
FGS-HMEC-F
FGS-MHIS-F
FGS-MHIS-JIG-A/B/F
FGS-MU4E-F
FGS-MD4E-F

FGS-MD9E-F
FGS-MTRM-F
FGS-MDSP-F
FGS-MDRT-F
FGS-MDSA-F2B
FGS-HIFC-F
FGS-MH9E-F
FGS-MSHS-F
4x12 Straight Section
Description
6-foot horizontal straight section
4x12 expandable straight section
6-foot snap-on cover
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MSHS-F
FGS-MVAR-F
FGS-MSSC-F
4x12 System Support Kits
Description
New threaded rod bracket (
5
/
8
-inch)
Existing threaded rod bracket (
5
/
8

-inch)
Top support threaded rod bracket kit
Top support low profile threaded rod bracket kit
Trapeze bracket kit
Ladder rack center support bracket kit
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-HNTR-F-5/8
FGS-HETR-F-5/8
FGS-HNTS-F-5/8
FGS-HNTS-F-5/8-LP
FGS-HNTP-F-5/8
FGS-HNLR-F
4x12 Junction
Description
4x12 snap-fit junction
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MFAW-F
FGS-MFAW-F
Covers are available for 4x12
fittings. Please contact ADC or
visit www.adc.com
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
303

w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
FiberGuide
®
Fiber Management System
Vertical Duct Systems
Description
2x2 vertical slotted duct kit, 6-feet
2x2 vertical 1.5-inch slotted duct kit, 6-feet
2x2 vertical solid duct
1x2 vertical duct kit
1x2 solid vertical duct kit
2x2 vertical to 1x2 vertical adapter bracket
2x2 vertical slotted duct, 6-feet
2x2 vertical 1.5-inch slotted duct, 6-feet
Cover for 2x2 vertical duct, 6-feet
2x2 vertical duct mounting bracket
4x4 vertical duct kit
4x4 vertical adapter junction kit
4x4 vertical slotted duct, 6-feet
Cover for 4x4 vertical duct, 6-feet
4x4 vertical duct mounting bracket
O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-KTW1-C
FGS-KTW1-CA
FGS-KTW4-C
FGS-KTW1-E

FGS-KTW4-E
FGS-ACC063
FGS-MSHS-C
FGS-MSHS-CA
FGS-MSHC-C
FGS-HWMB-D
FGS-KTW2-D
FGS-MJWR-D
FGS-MSHS-D
FGS-MSHC-D
FGS-HWMB-D
Accessories
Description
Flex Tubing
2-inch outer diameter slotted flex tube, 5-feet
2-inch outer diameter slotted flex tube, 10-feet
2-inch outer diameter slotted flex tube, 15-feet
1-inch outer diameter slotted flex tube, 100-feet
1-inch outer diameter slotted flex tube, 150-feet
1-inch outer diameter slotted flex tube, 200-feet
1-inch outer diameter slotted flex tube, 250-feet
7
/
8
-inch outer diameter slotted flex tube, 5-feet
7
/
8
-inch outer diameter slotted flex tube, 10-feet
7

/
8
-inch outer diameter slotted flex tube, 15-feet
7
/
8
-inch outer diameter slotted flex tube, 200-feet
Accessories
Hinge kit for 4x4 and 4x6 covers (kit of 1)
Self-closing hinge (kit of 3)
Retainer rings (kit of 10)
Trough cover clip kit
Mitre box and saw
Quick knobs (10)
Quick knobs (100)
Flex tube clamps (kit of 10)

O r d e r i n g I n f o r m a t i o n
Catalog Number

FGS-MIDY-5F
FGS-MIDY-10F
FGS-MIDY-15F
FGS-MLDY-100F
FGS-MLDY-150F
FGS-MLDY-200F
FGS-MLDY-250F
FGS-MFTY-5F
FGS-MFTY-10F
FGS-MFTY-15F

FGS-MFTY-200F

FGS-HHGK
FGS-HVHG
FGS-HFRR-10
FGS-KTO9
FGS-MKIT-ABF
FGS-KQKB
FGS-HQKK
FGS-HHEC-10
FGS-KTW2-D
FGS-MIDY
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
304
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
Plenum FiberGuide
®
System
System Description
ADC’s Plenum FiberGuide
®
System is a fiber
cable raceway system that protects optical fibers,
routed beneath raised computer room floors
and above suspended ceilings. These physical

areas, used to transport environment air, are
typically categorized as plenum air spaces by
National Electric Code (NEC) Standards. In
general, materials used in these spaces must be
non-flammable and must not emit appreciable
amounts of smoke or toxic gases when exposed
to heat or flame.
Made from sturdy aluminum, ADC’s Plenum
FiberGuide System protects optical fibers
by physically separating them from copper
communications cable, power cable, ground
cables, heating/ventilating ducts, water pipes and
many other obstructions commonly encountered
in plenum air spaces.
New Plenum FiberGuide Express Exits

allow
jumpers to be permanently or temporarily routed
to the fiber optic terminal (FOT) equipment or
fiber frames. No cutting is required because
knockout sections can be punched out as
necessary.
As seen in Figure 1, the Plenum FiberGuide
System can be used above a dropped ceiling as
well as below a raised computer floor.
Figure 2 details a layout below a computer
floor. This illustration shows a plenum FiberGuide
System featuring new Express Exits.
Dropped
Ceiling

Raised
Floor
Fiber
Distribution
Devices
Fiber
Optic
Equipment
Figure 1
Figure 2
All plenum components, including
mounting hardware for mounting the
FiberGuide to the raised floor struts,
are available in the Plenum FiberGuide
product line.
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
305
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
Plenum FiberGuide
®
System
System Description
2x2, 4x6, and 4x12 Junction Kits
4x6 Horizontal Straight Section with Express Exit Cutouts
2x2 Horizontal Straight Section

4x6 Horizontal Straight Section
4x12 Horizontal Straight Section
Straight sections: U-shaped troughs that provide a protective pathway for optical fibers. Straight
sections are usually installed horizontally but may also be installed vertically when a system is mounted
on multiple levels. Straight sections are six feet in length, and covers are also available. The covers snap
into place but can be easily removed for fiber installation.
New Express Exits

: The Plenum FiberGuide
®
Express Exit system allows jumpers to be routed in and
out of the system with ease. Express Exits are secured to the sidewall of a FiberGuide straight section
where needed. No cutting is required because knockout sections allow for quick and easy deployment.
Fittings: Elbows, tees, crosses, trumpet flares and conversions. The fittings are used for changing
direction, converting from one size system to another, adding branch segments and routing the fibers
in and out of the system. Like the straight sections, snap-on covers are also available for the fittings.
Junction kits: Used for aligning and connecting straight sections and fittings. Two components are
joined by inserting them into a junction and pushing them together.
Support kits: Used to support the FiberGuide system. The short, long, span and diagonal bracket kits
are used for supporting straight sections from round or square tubing.
Flexible tubing: Used in Plenum FiberGuide systems when the exact layout of the equipment drop
locations is unknown or when frequent equipment relocations are expected. The flexible tubing is
two inches in diameter and attaches to the end of a straight section with an adapter. When the
equipment configuration is known, the flexible tubing is routed to the exact drop location. Other
flexible tubing components include splicing couplers, finishing couplers, mounting straps and
additional lengths of tubing.
Both patch cords and IFC cables may be installed in the Plenum FiberGuide System. The required two
inch bend radius for patch cords is maintained at all points within the system. IFC cables require the use
of tie-down brackets to maintain the required cable bend radius specified by the cable manufacturer at
the various fittings.

3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
306
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
Plenum FiberGuide
®
System
Recommended capacity takes into consideration random jumper placement into the FiberGuide
®

system. Trough capacity refers to the maximum number of fiber jumpers in a given cross-section
of a FiberGuide installation.
Using Lab Manual Set-ups
Pile-up beyond 2 inches is not recommended
1.7mm 2.0mm 3.0mm

Patch Cords Patch Cords Patch Cords


Maximum
Patch Cord 142 102 44
Density (per in
2
)
Using GR-449-CORE Bellcore Formula


1.7mm 2.0mm 3.0mm
Recommended
Patch Cord 120 90 40
Density (per in
2
)
Single Patch Cords
Trough
Pile-up
2-inch
3-inch
4-inch
2x2 FiberGuide
System
1.7mm 2.0mm 3.0mm
480 360 160

- - -

- - -
4x6 FiberGuide
System
1.7mm 2.0mm 3.0mm
1440 1080 480

- 1620 720

- 2160 960
4x12 FiberGuide
System

1.7mm 2.0mm 3.0mm
2880 2160 960

4320 3240 1440

5760 4320 1920
Trough
Pile-up
2-inch
3-inch
4-inch
2x2 FiberGuide
System
1.7mm 2.0mm 3.0mm
568 408 176

- - -

- - -
4x6 FiberGuide
System
1.7mm 2.0mm 3.0mm
1704 1224 528

2556 1836 792

3408 2448 1056
4x12 FiberGuide
System
1.7mm 2.0mm 3.0mm

3408 2448 1056

5112 3672 1584

6862 4896 2112
Recommended Density
Maximum Density
Patch Cord Densities
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
307
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Fiber Cable Raceway Systems
Plenum FiberGuide
®
System

The 2x2 Plenum FiberGuide
®
system interfaces with ADC’s standard 2x2 FiberGuide System and
requires no special conversion piece.
Straight section
2x2 straight section—length: 6'
Fittings
2x2 horizontal T

2x2 horizontal cross


2x2 90º horizontal elbow

2x2 45º horizontal elbow

2x2 90º up elbow

2x2 90º down elbow

2x2 45º up elbow

2x2 45º down elbow
Trumpet flares
2x2 trumpet flare—3 sided

2x2 trumpet flare—4 sided
Conversions
2x2 Plenum to 4x6 Plenum conversion

2x2 Plenum to 4x12 Plenum conversion
Junctions
2x2 junction

2x2 end cap—Includes 2x2 junction
PFGF-PSHS-C PFGC-PSHS-C –

PFGF-PHRT-C PFGC-PHRT-C 3
PFGF-PHXP-C PFGC-PHXP-C 4
PFGF-PH9E-C PFGC-PH9E-C 2
PFGF-PH4E-C PFGC-PH4E-C 2

PFGF-PUPE-C PFGC-PUPE-C 2
PFGF-PDNE-C PFGC-PDNE-C 2
PFGF-PU4E-C PFGC-PU4E-C 2
PFGF-PD4E-C PFGC-PD4E-C 2

PFGF-PTRM-C – –
PFGF-PFPT-C – –

PFGF-PDSA-C/B PFGC-PDSA-C/B (1) 2x2 (1) 4x6
PFGF-PDSA-C/F PFGC-PDSA-C/F (1) 2x2 (1) 4x12

PFGF-PJWR-C – –
PFGF-PMEC-C – –
Catalog Number
Number

Description Fitting Snap-on Cover of Junctions
O r d e r i n g I n f o r m a t i o n
2x2 System (2"H x 2"W)
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
308
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Cable Management Solutions
Plenum FiberGuide
®
System

Catalog Number
Number

Description Fitting Snap-on Cover of Junctions
Straight section
4x6 straight section—6' long
Fittings
4x6 horizontal T

4x6 horizontal cross

4x6 90º horizontal elbow

4x6 45º horizontal elbow

4x6 90º up elbow

4x6 90º down elbow

4x6 45º up elbow

4x6 45º down elbow
Trumpet flares
4x6 trumpet flare—3 sided

4x6 trumpet flare—4 sided
Conversions
4x6 Plenum to 4x6 standard conversion

* One 4x6 Plenum junction kit

required; 4x6 standard junction


is not required
4x6 Plenum to 12" Plenum conversion
Junctions
4x6 junction

4x6 end cap—includes 4x6 junction
PFGF-PSHS-B PFGC-PSHS-B –

PFGF-PHRT-B PFGC-PHRT-B 3
PFGF-PHXP-B PFGC-PHXP-B 4
PFGF-PH9E-B PFGC-PH9E-B 2
PFGF-PH4E-B PFGC-PH4E-B 2
PFGF-PUPE-B PFGC-PUPE-B 2
PFGF-PDNE-B PFGC-PDNE-B 2
PFGF-PU4E-B PFGC-PU4E-B 2
PFGF-PD4E-B PFGC-PD4E-B 2

PFGF-PTRM-B – –
PFGF-PFPT-B – –

PFGF-PPSC-B – 1*



PFGF-PDSA-B/F PFGC-PDSA-B/F (1) 4x6, (1) 4x12

PFGF-PJWR-B – –

PFGF-PMEC-B – –
O r d e r i n g I n f o r m a t i o n
4x6 System (4"H x 6"W)
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
309
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Cable Management Solutions
Plenum FiberGuide
®
System
Short bracket kit
for use with 2x2 and 4x6 sizes; 8.21" overall length
Short bracket kit with square U-bolt for easy access mounting
Long bracket kit
for use with 2x2, 4x6, and 4x12 sizes; 18.84" overall length
Long bracket kit with square U-bolt for easy access mounting
Span bracket kit
for use with 2x2, 4x6, and 4x12 sizes; spans 24" center to center floor struts
Span bracket kit with square U-bolt for easy access mounting
Diagonal span bracket kit

for use with 2x2, 4x6, and 4x12 sizes; spans diagonally up to 34" between struts
Diagonal span bracket kit with square U-bolt for easy access mounting
PFGF-SSPT-C/B
PFGF-EASSPT-C/B
PFGF-LSPT-C/B/F

PFGF-EALSPT-C/B/F
PFGF-ESPT-C/B/F
PFGF-EAESPT-C/B/F
PFGF-DSPT-C/B/F
PFGF-EADSPT-C/B/F
Description
Catalog Number
O r d e r i n g I n f o r m a t i o n
All support bracket kits fit round support pedestals sizes 0.5" to 1.125".
Accessories (Support Bracket Kits)
4x12 System (4"H x 12"W)
Catalog Number
Number

Description Fitting Snap-on Cover of Junctions
O r d e r i n g I n f o r m a t i o n
Straight section
4x12 straight section—6' long
Fittings
4x12 horizontal T

4x12 horizontal cross

4x12/4x6 horizontal T

4x12 90º horizontal elbow

4x12 45º horizontal elbow

4x12 90º up elbow


4x12 90º down elbow

4x12 45º up elbow

4x12 45º down elbow
Trumpet flares
4x12 trumpet flare—3 sided

4x12 trumpet flare—4 sided
Junctions
4x12 junction

4x12 end cap—includes 4x12 junction
PFGF-PSHS-F PFGC-PSHS-F –

PFGF-PHRT-F PFGC-PHRT-F 3

PFGF-PHXP-F PFGC-PHXP-F 4

PFGF-PHRT-F/B PFGC-PHRT-F/B (2) 4x12, (1) 4x6

PFGF-PH9E-F PFGC-PH9E-F 2

PFGF-PH4E-F PFGC-PH4E-F 2

PFGF-PUPE-F PFGC-PUPE-F 2

PFGF-PDNE-F PFGC-PDNE-F 2


PFGF-PU4E-F PFGC-PU4E-F 2

PFGF-PD4E-F PFGC-PD4E-F 2

PFGF-PTRM-F – –

PFGF-PFPT-F – –

PFGF-PJWR-F – –

PFGF-PMEC-F – –
3 / 0 6 • 1 0 2 0 9 4 A E
TrueNet
®
Structured Cabling
310
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 • 1 - 8 0 0 - 3 6 6 - 3 8 9 1
Fiber Cable Raceway Systems
Cable Management Solutions
Plenum FiberGuide
®
System
Accessories (Flexible Tubing)
One hose adapter, with 5' (1.53m) hoses and finishing couplers
Two hose adapter, with 5' (1.53m) hoses and finishing couplers
Extension tube, 5' (1.53m) long with splice coupler
Finishing coupler
Mounting strap
Splicing coupler
Flexible tubing, 2" (5.08cm) inner diameter

(
X = length in feet: 5, 15, 35, 75, 110, 150)
Tie down bracket for IFC
PFGF-KT03-C
PFGF-KT03-B
PFGF-HEXT
PFGF-HFIN
PFGF-HMST
PFGF-HSPL
PFGF-MIDY-XFI
PFGF-PIFC
Description
Catalog Number
O r d e r i n g I n f o r m a t i o n

×