KRONE has a long history as a market leader in the
communications and information industry.
Founded in 1928 by Gustav Krone, the KRONE
Group is one of the world’s leading suppliers of the
interconnection and distribution systems used in
telecommunications and data networks.
KRONE is represented in 140 countries around the
globe by 29 subsidiaries, 80 sales partners and
approximately 3,000 employees.
Our core LSA-Plus quick connection system, which
allows wire connection without soldering, screwing
or insulation removal, is considered an industry
standard in more than 140 markets worldwide.
INTRODUCTION
The use of KRONE’s HIGHBAND
TM
range within a
structured cable system enables highspeed LAN
and WAN systems “Maximum Headroom” in
transmission performance. It is the only product on
the market which far exceeds International
Category 5e performance standards and even
proposed Category 6
This improved cross connection system offers
extended bandwidth capacity and transmission
performance - a feature required in today’s
cabling systems to meet the demands of
tomorrow’s networks.
HIGHBANDconfigures and integrates easily with all


existing KRONE solutions and is part of the KRONE
PremisNET
TM
range of cabling systems. It also forms
a critical component of KRONE’s impedance
matched TrueNet
TM
structured cabling systems.
TrueNet is the first cabling system in the world to
eliminate data errors in the cabling channel
dramatically enhancing network efficiency and
performance. HIGHBAND is space saving, easy to
manage, and its ability to allow jumpering,
patching, or Patch-By-Exception, makes it the most
flexible system on the market today.
When patching, HIGHBAND gives you proven
reliability by the use of a centre port for the
connection which is separate to the wire
termination point.
The unique design of the silver plated KRONE LSA
Plus contact and its mechanical cable support gives
you the most reliable and secure connection
method available.
HIGHBAND is manufactured in Australia under the
ISO9001 Quality Standard and is sold world wide
through the KRONE global distribution network.
KRONEHIGHBAND
page three
FEATURESANDBENEFITS
Bandwidth Higher bandwidth capacity allows you to install a cabling system

that is capable of handling emerging technologies
Silver contact plating Silver has an electrical conductance that is 6.9 times greater than tin.
45 degree contact positioning By placing contacts at 45 degree angles across the axis of the wire,
much less stress is placed on the wire at point of termination.
Centre port access HIGHBAND allows you to test/monitor access to a hardwired
circuit without breaking that circuit.
Jumper & Patch The HIGHBAND module allows you to jumper and patch on the
one module.
2 conductor slots HIGHBAND guarantees you two conductor terminations per slot.
Low insertion force The high insertion force needed to terminate other systems can
cause stress on the wire.
Single pair management HIGHBAND allows individual pair management as opposed to
RJ solutions which do not.
Work access from front of modules With the HIGHBAND module all connections are made from the
front facilitating cable administration.
Vital component of TrueNet HIGHBAND 8 and Ultim8 modules are specially tuned to perform
cabling system within the TrueNet structured cabling system offering impedance
values of 100 (±3) ohms compared to the industry standard
of 100 (± 15) ohms.
TECHNICALSPECIFICATIONS
Operating conditions:
Environment for use: Indoors in dry closed rooms
Operating temperature range: 40º to +80º C
Maximum relative humidity: •93% non-condensing
Wire range: 0.4 - 0.65mm (26-22AWG)
Wire insulation diameter
range (PE, PVC): 0.7 - 1.4mm
Number of wire re-terminations: Ž>200
Wire insertion force
(0.5mm conductor diameter): Typically 6N

Contact force of disconnection point: 2N
Number of patching cycles: Ž>750
Transmission and
reliability: Exceeds requirements of ISO 11801
AS 3080-2000 (draft) and EIA/TIA 568-A-5
Average worst case near end cross talk
performance for the following applications:
Hard wired (jumpered):
- 8 pair module: 53 dB @ 100 MHz
- Compact 8 module: 49 dB @ 100 MHz
- 10 pair module: 49 dB @ 100 MHz
- Ultim8 8 pair module 55 dB @ 200 MHz
Patched:
- 8 pair module: 63 dB @ 100 MHz
- Compact 8 module: 55 dB @ 100 MHz
- 10 pair module: 55 dB @ 100 MHz
- Ultim8 8 pair module: 67 dB @ 200 MHz
- 16 pair module: 53 dB @ 100 MHz
- 20 pair module: 53 dB @ 100 MHz
page four
HIGHBANDCONTACT
THEINDUSTRY’SMOSTSECURECONNECTION
3. 45° "torsion" contactmaintain a
continual force on the connection.
Grips wire from two directions
for greater security.
Resists wire being pulled out
from top or bottom.
Never overstressesthe contact
(even with wire as large as 0.65mm).

1. Clamping ribsisolate contact
area from stress.
t
Effects On Wiring
KRONE vs Others
The KRONE 45
o
contact leaves more wire
between the contact points.
Accepts from 0.4 to 0.65mm
Double termination same gauge wire on
single terminal.
Silver-plated contact oxidation doesn’t
affect conductivity.
Insertion Tool means less stress on wire
90
o
contacts can weaken wire increasing
breakage.
Must be able to take UTP/STP which is 0.5mm
Punch down only one wire per terminal.
Tin-plated contact corrosion
reduces conductivity.
Impact Tool causes high stress on wire
2. Silver-plated contactsmake a
secure, gas-tight connection with
superior corrosion resistance.
t
t
KRONE LSA PLUS Series 2

Disconnection Contact
Transmission Path
Length = 72mm
KRONE HIGHBAND
Disconnection Contact
Transmission Path
Length = 32mm
page six
DESIGNINGBUILDINGANDFLOORDISTRIBUTORS
When configuring a floor distributor, using KRONE
HIGHBAND modules, a number of options are
available to meet the requirements of each specific
site. There is also a wide range of KRONE
mounting hardware to suit all distributor sizes.
The basic frame layout should comprise discrete
fields as shown in the example below. It is good
practice to balance up your frame, for example by
positioning your work area field in the centre of
the frame to segregate the vertical cabling and
data ports on the floor distributor.
HIGHBAND is unique in that it gives the user
multiple cross connect choices based on the
following two basic cross connect methods:
1. Jumper Cross Connect
- For both voice and high speed data traffic.
- The most economical method when there is
infrequent need for changes or where better
administration and control is required
- Subsequent savings on patch panels and cords

can be used to purchase additional data hub
ports to liven up spare outlets - simplifying
workstation moves and patch administration.
2. Patch Cross Connect
- For both voice and high speed data traffic.
- Provides the easiest method of cross connecting
A combination of both jumpering and patching can
be used for the optimum mix of methods to suit
particular operational requirements, eg:
Jumper the voice cross connects and
patch the data
This mix of methods could be used when flexible
data configuration is required but the telephone
environment is stable and the extensions can be
changed electronically at the PABX. This mix would
allow some cost savings.
Patch-By-Exception
This is the best all-round solution when you have a
large number of cross connections (>100) and
when:
- Cost-cutting is essential
- High reliability coupled with moderate flexibility
and ease of use are essential. The PBE method
facilitates administration and control of moves
and changes.
- High density Telco connectorised hub equipment
is used.
Incoming 25, 50 or 100
pair voice cable
4pr Cat5e UTP

Work Area Cables
Multiple 4 pair to
RJ45 patch leads*
Vertical A
HIGHBAND
Vertical B
HIGHBAND MODULES
Vertical C
HIGHBAND MODULES
Vertical Cabling
Work Area Field Data Field
* Note: HUB can be patched
directly to Vertical B using
HIGHBAND to RJ45 patchcords
*Note: KRONE LSA Plus Series 2 modules can be used in the
voice or vertical cabling field where performance up to
Category 4 is acceptable. This gives an advantage of increased
density and provides the possibility for the fitting of over
voltage protection should it be required on the distribution.
page seven
Example: Designing a Floor Distributor for
100 Workstations
Design Criteria
- Two outlets per workstation (one voice, one data)
i.e. RJ45
- The area is served by an electronic PABX with 120
four wire extensions to provide one extension to
every workstation using 10x25 pair cable or 250
pair riser cable
- Infrequent moves are expected

- 100 BASE-T hub with 64 ports to be initially
installed to serve 50 of the workstations
- Gigabit Ethernet and ATM expected to be used
on network cabling in two years’ time
- Need to keep budget costs down
Basic decisions from criteria:
- Use HIGHBAND 8 modules on PABX, data and
work area fields
- Jumper all cross connections and Patch-By
Exception when infrequent moves are required
- Run short patch cables from 100 BASE-T hub
ports to data vertical and terminate 2 ports
(i.e. 8 pairs) per HIGHBAND 8 module. Use
modular plugs suited to solid conductor cable or
cut pre-manufactured patch cords in half and
punch down stranded cable at Highband 8.
Calculations:
Question: How many HIGHBAND 8 modules are
needed?
Answer:
(a) On work area field: Answer = 100 HIGHBAND 8
modules. Remember, one HIGHBAND 8 module
can accommodate two 4 pair outlets. There are
100 workstations with two outlets per workstation,
making a total of 200 outlets. Therefore 100
HIGHBAND 8 modules are required.
(b) On data field vertical: Answer = 32 HIGHBAND
8 modules. Since we will terminate two 10 BASE T
ports per module and as there are 64 ports; 32
modules are needed.

(c) On the voice or riser field: Answer = 32
HIGHBAND 8 modules. There are a total of 120
x 2 pair telephone circuits. This equals 240
pairs. Therefore 30 HIGHBAND8 modules are
required to terminate the specified extensions
and two modules are required to terminate the
spare cable pairs.
In total, the Distributor will use 164 HIGHBAND
8 modules.
Vertical A
Vertical B Vertical C
From Data Rack
To work stationsFrom Riser/PABX
Note: Jumper all cross connection in initial installation using
Cat 5e jumper cable. Store a quantity of 10 HIGHBAND 8/16
2 or 4 pair patch cords at the site of the distributor for patch
by exception, and use these when required.
Workstations
50 Modules
Workstations
50 Modules
Data
32 Modules
PABX
32 Modules
page eight
TrueNet's zero bit error rate guarantee is
revolutionising the structured cabling industry. Until
now, no other cabling solution has been able to
deliver what Network Managers want most -

optimum data throughput. Companies worldwide
are now enjoying increased network speed and
efficiency resulting from adopting a TrueNet solution.
TrueNet Cat 5eT and Cat 6T systems are available in
a RJ solution format, and can also be configured
using KRONE's HIGHBAND 8 or Ultim8 IDC modules.
Utilising HIGHBAND modules as part of the TrueNet
solution makes KRONE's cost effective and easy to
manage Patch-By-Exception function possible.
During the research and development stage of
TrueNet, KRONE HIGHBAND connectors and KRONE
cable were finely tuned to achieve an impedance
match of 100 (±3) ohms, which is five times greater
than the IEEE standard of 100 (±15) ohms for
network cabling components. This level of
impedance matching has reduced the occurrence of
data errors, caused by the cabling system, and
subsequent re-transmissions to such a negligible
level that KRONE actually guarantees zero bit error
rate performance from the TrueNet system.
HIGHBAND ANDTHETRUENETSOLUTION
TrueNet C6T HIGHBAND Module Solution
Hub/Switch
TruePatch
TM
C6T
TrueNet
TM
C6T Cable
HIGHBAND

Ultim8
Blocks
HIGHBAND
Jacks
TruePatch
TM
C6T
TrueNet C5eT HIGHBAND Module Solution
Hub/Switch
TruePatch
TM
C5eT
TrueNet
TM
C5eT Cable
HIGHBAND 8
Block
C5e Jacks
TruePatch
TM
C5eT
page nine
A Consolidation Point is particularly useful when
wiring to modular furniture, workstation clusters or
partitioned office areas. When moving modular
furniture or office partitions, there is no need to
run new cabling all the way back to the Floor
Distributor (which could be up to 90 metres). You
only need to renew the last few metres from the
Consolidation Point to the workstation outlets.

HIGHBANDConsolidation points can be
accommodated in:
•Wall boxes, e.g. KRONECTIONBoxes
•Floor boxes
•Ducting
•Ceiling spaces
•Utility poles
Example One: A Consolidation Point Serving
Three Dual RJ45 Outlets
Terminate the multiple 4 pair Category 5e cable
from the Floor Distributor.
Equipment required:
•3 x HIGHBAND8 modules
•1 x 3 way backmount frame
•KRONECTIONBox size I or
30 Pair Distribution Box
CONSOLIDATIONPOINTS
Multiple 4 pair Cat5e UTP
cable from Floor Distributor
4 pair Cat5e cable
HIGHBAND 8 modules
KRONECTIONBox 1
INSTALLATIONPRACTICES
Installation of Cables
Cables can enter the frame (either backmount or
Profil) from the top or bottom. Minimum cable
length should equal the distance to the termination
point plus 300 mm. Cables should be velcro tied
but not too tightly, at randomly spaced intervals (of
approx. 200 mm) inside the mounting frame.

Termination of Cables
Cables can be terminated either before or after the
module is mounted on the frame. When using a
Profil frame it is recommended to mount one end
of the module only to allow access to the rear of
the module, leaving both hands free for cable
feeding and termination.
Always commence with the module at the lowest
point on the frame. Ensure module is mounted
with KRONElogo facing up.
Fan the pairs to the corresponding termination
point. (The maximum untwist distance allowable
under the standards for Category 5e installations is
13 mm.) Place the wires in the termination slots
and terminate using a KRONE termination tool
(note: only a genuine KRONETool can be used).
After termination of the module is complete, place
the module on the mounting frame and repeat the
process on the next module.
Running of Jumpers &Patch Cords
Patch CordsPatch Cords
Insert the patch cord in the centre access port for
the pairs to be patched. Interlocking guides prevent
the patch cord from being inserted upside down.
Loop the patch cord back through the guide ring
provided on the side of the module nearest the
pairs to be patched.
Always maintain a minimum bend radius of four
times the cable diameter. The patch cord should
then be run to the top of the frame and across to

the desired location at the other end.
JumpersJumpers
Feed the Category 5e cable through the guide ring
provided on the side of the module.
Fan and place theCategory 5e jumper wire in the
termination slots of the desired pairs ensuring the
twist rate is maintained to the point of termination
(bottom row of the HIGHBAND 8 and HIGHBAND
10 disconnection modules).
Terminate each wire using a KRONE termination
tool. The jumper wire should then be run to the
top of the frame and guided across to the desired
location on the frame using the main jumper rings
and terminated appropriately.
page ten
Termination of Jumper Cable
Patch-By-Exception
PATCHBYEXCEPTION- HOWDOESITWORK?
Patch-By-Exception is a solution whereby you hard wire your network and make subsequent changes utilising
patch cords. The diagram shows a patch cord changing the input from workstation one to workstation two.
The cord disconnects the jumpers leading to workstation one and re-directs the signal through the patch
cord to workstation two. To go back to the original configuration, simply remove the patch cord. If the
change is to be made permanent, a cabling specialist can be called in to hard wire the configuration and the
removed patch cord can be reused for other temporary changes.
page twelve
Permanent services are hardwired
rather than patched
Data side frame does not need to be
co-located with active equipment

Category 5, 5e, or 6 cable is used
instead of patch cords.
Extensive labelling options
'19 inch' accommodation such
as racks is not required.
Capacity for mounting with
existing LSA modules
Testing convenience
This provides a neat and tidy cable management solution and allows
for greater flexibility of wiring arrangements and superior reliability.
Reduces cabinet and floor space requirements and costs. Is
particularly effective with high density Telco connectorised hubs
which allows further cabinet space reductions.
This method is more cost effective as jumper cable is cheaper
than the equivalent length of patch cord. Performance is
enhanced due to the lower attenuation of jumper cable and the
elimination of one plug and socket in the channel.
More information can be displayed on the modules reducing the
need to refer to other documentation.
Makes this solution cost effective as '19 inch' racks are more
expensive. Fits in shallow wall recesses or closets.
Cost Reduction.
Suspected faulty hub or PABX ports can be tested or rerouted to
locate problems without losing the underlying patch.
FEATURESANDBENEFITS
INPUTONE
INPUTTWO
WORKSTATIONONE
WORKSTATIONTWO
page thirteen

After the installation is complete, every installed
HIGHBANDcircuit should be tested. This can be
done using a hand held scanner. Using a
HIGHBAND 4 pair to RJ45 patch cord (as shown),
test each link for attenuation, crosstalk and ACR.
The table below is taken from AS3080-2000 (draft)
and indicates minimum results that must be
achieved for a Class D Cat5 link and Class E Cat6
link. (Check with your Standards organisation for
local requirements.) The results achieved should be
printed and given to the owner of the site at time
of hand over.
TESTINGOFHIGHBANDCIRCUITS
Near End Near End
Frequency Insertion Loss Crosstalk Loss Insertion Loss Crosstalk Loss
(MHz) (dB) (dB) (dB) (dB)
Class D Class D Class E Class E
1.0 1.9 64.2 2.2 72.7
4.0 3.7 54.8 4.2 63.0
10.0 5.9 48.5 6.5 56.6
16.0 7.5 45.2 8.3 53.2
20.0 8.5 43.7 9.3 51.6
31.25 10.7 40.5 11.7 48.4
62.5 15.5 35.7 16.9 43.4
100.0 20.0 32.3 21.7 39.9
200.0 N/A N/A 31.7 34.8
250.0 N/A N/A 36.0 33.1
Notes
Insertion LossInsertion Loss- Attenuation is the amount of loss of a signal brought about through the characteristics of
any transmission medium.

Near End Crosstalk LossNear End Crosstalk Loss- This refers to interference caused by unwanted coupling of electrical signal power
from one pair into adjacent pairs within the same cable sheath. A high value indicates low levels of
unwanted signal and best performance.
These figures were correct at the time of printing in line with the latest draft of the Australian Standards.
Please check the figures contained in the final published document or the Standard for your local market.
TECHNOLOGYCOMPARISON- HIGHBANDVS110 TYPE
FEATURE KRONE 110 EXPLANATION
HIGHBAND TYPE
Bandwidth NEXTLoss @ NEXTLoss @ Higher headroom capacity allows you to
(patched) 100 MHz = >63dB 100 MHz = <49dB install a network that is capable of
handling emerging technologies.
Contact Silver Tin Silver has an electrical conductance that
plating is 6.9 times greater than tin.
IDCcontact 45º 90º By placing contacts at 45º angles across the
positioning axis of the wire, far less stress is placed
on the wire at point of termination.
Centre port Yes No HIGHBAND allows you test/monitor access
access to a hardwired circuit.
Jumper & Yes No The HIGHBANDmodule allows you to
patch jumper and patch on the one module. 110
systems allows one or the other, NOTBOTH.
Patch-By- Yes No Useful for temporary moves and changes.
Exception This feature allows you to leave jumpers in
place and patch to the new temporary
location.
Number of 2 1 HIGHBAND guarantees you two
conductors conductor terminations per slot.
per slot
Insertion Low High The high insertion force needed
force to terminate the 110 type blocks

can cause stress on the wire.
Stranded Yes No Contact angle and reduced wire stress
conductor allows reliable stranded conductor
termination termination.
page fourteen
page fifteen
FEATURE KRONE RJCross EXPLANATION
HIGHBAND8 Connect
Low cost Yes No RJ cross connection requires 19” rack
mounting system mounting. Depending on the size of the
installation this can be quite expensive.
Jumper &patch Yes No RJ allows for patch only.
Patch-By-Exception Yes No The flexibility of the HIGHBANDmodule
allows either jumpering or patching.
Test access point Yes No The HIGHBAND centre port allows for test
access.
Single pair Yes No With RJ when one wire is connected all are
administration connected and pairs cannot be managed.
HIGHBAND allows for single, double and
four pair management.
Work access Yes No With the HIGHBAND module all
from front connections are made from the front which
of module makes cable termination much easier.
Extremely high Yes No HIGHBANDhas far superior transmission
transmission NEXT Loss @ NEXT Loss @ performance. Eliminates performance
performance 100MHz = >63dB 100MHz typically reducing compromises inherent in the
= 45dB modular connector design
Easy to configure Yes No RJdoes not allow splitting or paralleling
to star ring or of pairs
bus topology

TECHNOLOGYCOMPARISON- HIGHBANDVSRJ
page sixteen
HIGHBAND Compact 8 Disconnection Module
Compact Category 5e Module. Pairs numbered
1-8 for eight incoming & eight outgoing pairs. Requires
special mounting frame.
Product Number: 6468 5 061-08
Pack Quantity: 10
HIGHBAND Ultim8 Disconnection Module
Ultim8 exceeds the proposed Cat 6 component Standard
when hard wired or patched. This allows for Patch-By-
Exception to be utilised and still maintain Cat 6 performance.
Product Number: 6468 5 060-06
Pack Quantity: 10
HIGHBAND 8 Disconnection Module
Category 5e Disconnection Module for termination of
two x 4 pair UTP cables. Colour coded to make
termination of cables easy. Ideal for use in horizontal
cabling. Used for Category 5e jumpering, patching and
Patch-By-Exception.
Product Number: 6468 5 060-00
Pack Quantity:10
HIGHBAND 10 Disconnection Module
Category 5e Disconnection Module for termination of
ten incoming and ten outgoing pairs. Pairs numbered 1-
10, ideal for use in backbone cabling where high density
and disconnect features are required.
Product Number: 6468 5 061-00
Pack Quantity: 10
HIGHBAND 16 Switching Module

Category 5e Switching Module for termination of four x
4 pair cables. Colour coded to make termination of
cables easy. Ideal for use in horizontal cabling where
high density is more important than the disconnection
feature. Provides patching for 16 pairs. Brown cross
hatching on top row of module.
Product Number: 6468 5 080-00
Pack Quantity: 10
HIGHBAND 20 Switching Module
Category 5e Switching Module for termination of 20
incoming and 20 outgoing pairs. Ideal for use in
backbone cabling where high density is more important
than the disconnection feature. Pairs numbers 1 - 10 on
bottom row with brown cross hatching on top row.
Provides patching for 20 pairs.
Product Number: 6468 5 081-00
Pack Quantity: 10
HIGHBANDPRODUCTRANGEIDENTIFICATIONANDAPPLICATION
Note: All HIGHBAND modules are UL certified for performance and safety.
All Disconnect modules allow centre port access and disconnect facility.
page seventeen
HIGHBAND 1 Pair Test Plug Set, 2 Pole
To be used on HIGHBAND modules only. Used to
test the circuit.
Product Number: 6451 2 055-00
Pack Quantity: 1
HIGHBAND 1 Pair Voice Patch Cords
Used for patching between HIGHBAND modules and
Series 2 modules. Provide one pair patching only.
Product Number: 6451 2 059-01 0.5m

6451 2 059-11 1.0m
6451 2 059-21 2.0m
6451 2 059-31 3.0m
6451 2 059-51 5.0m
Pack Quantity: 2
HIGHBAND 1/2 Pair Patch Cords
For use on all HIGHBAND modules. Provides one
pair patching on HIGHBAND 8 and HIGHBAND 10
and two pair patching on HIGHBAND 16 and
HIGHBAND 20.
Product Number: 6451 2 048-01 0.5m
6451 2 048-11 1.0m
6451 2 048-21 2.0m
6451 2 048-31 3.0m
6451 2 048-51 5.0m
Pack Quantity: 2
HIGHBAND 1/2 Pair to RJ45 Patch Cords
Used for patching between HIGHBAND modules and
equipment with an RJ45 interface. Provides one pair
patching on HIGHBAND 8 and HIGHBAND 10, and two
pair patching on HIGHBAND16 and HIGHBAND 20
Product Number: 6451 2 080-01 0.5m
6451 2 080-11 1.0m
6451 2 080-21 2.0m
6451 2 080-31 3.0m
6451 2 080-51 5.0m
Pack Quantity: 2
HIGHBAND 8/16, 2 or 4 Pair Patch Cords
For use on HIGHBAND 8 and HIGHBAND 16 modules
only. Provide two pair patching on HIGHBAND 8 and

four pair patching on HIGHBAND 16.
Product Number: 6451 2 050-01 0.5m
6451 2 050-11 1.0m
6451 2 050-21 2.0m
6451 2 050-31 3.0m
6451 2 050-51 5.0m
Pack Quantity: 2
page eighteen
HIGHBANDPRODUCTRANGEIDENTIFICATIONANDAPPLICATION
HIGHBAND 8/16, 2 or 4 Pair to 4 Pair Patch Cords
Used for patching between HIGHBAND 8 and Highband
16 modules.
Product Number: 6451 2 071-05 0.5m
6451 2 071-10 1.0m
6451 2 071-15 1.5m
6451 2 071-20 2.0m
Pack Quantity: 2
HIGHBAND 8/16, 2 or 4 Pair toRJ45 Patch Cords
Used for patching between HIGHBAND modules and
equipment with an RJ45 interface. For use on
HIGHBAND 8 and Highband 16 modules only. Provide
two pair patching on HIGHBAND 8 and 4 pair patching
on HIGHBAND 16.
Product Number: 6451 2 057-01 0.5m
6451 2 057-11 1.0m
6451 2 057-21 2.0m
6451 2 057-31 3.0m
6451 2 057-31 5.0m
Pack Quantity: 2
HIGHBAND 8, 4 Pair Patch Cords

For use on HIGHBAND 8 modules. Provides 4 pair
patching. Specially designed for Patch-By-Exception.
Product Number: 6451 2 051-01 0.5m
6451 2 051-11 1.0m
6451 2 051-21 2.0m
6451 2 051-31 3.0m
6451 2 051-51 5.0m
Pack Quantity: 2
HIGHBAND 8, 4 Pair to RJ45 Patch Cords
Used for patching between HIGHBAND modules and
equipment with an RJ45 interface. For use on
HIGHBAND 8 modules only. Provides 4 pair patching.
Product Number: 6451 2 058-01 0.5m
6451 2 058-11 1.0m
6451 2 058-21 2.0m
6451 2 058-31 3.0m
6451 2 058-51 5.0m
Pack Quantity: 2
HIGHBAND 10, 2 Pair to RJ45 Patch Cord
Used for Patching between HIGHBAND 10 modules and
equipment with an RJ45 interface. Provides 2 pair
patching.
Product Number: 6451 2 104-10 1m Blue
6451 2 104-20 2m Blue
6451 2104-30 3m Blue
Pack Quantity: 2
page nineteen
HIGHBAND 10, 4 Pair to RJ45 Test Cord
Used for testing HIGHBAND 10 circuits. Test Cord 3m.
Product Number: 6451 2 099-30

Pack Quantity: 1
HIGHBAND 10, 2 Pair to 2 Pair Patch Cord
Used for patching between HIGHBAND 10
modules. Provides 2 pair patching.
Product Number: 6451 2 103-10 1m Blue
6451 2 103-20 2m Blue
6451 2 103-30 3m Blue
Pack Quantity: 2
HIGHBAND 10, 4 Pair to 4 Pair Patch Cord
Used for patching between HIGHBAND 10
modules. Provides 4 pair patching.
Product Number: 6451 2 101-10 1m Blue
6451 2 101-20 2m Blue
6451 2 101-30 3m Blue
Pack Quantity: 2
HIGHBAND to Series 2 Adaptor
Used for testing HIGHBAND modules with a Series
2 test lead.
Product Number: 6451 2 178-04 4 Pole
Pack Quantity: 1
HIGHBAND Disconnection Plugs
Plugs for disconnecting a circuit. Can only be used
on HIGHBAND 8 and HIGHBAND 10 modules.
Product Number: 6462 2 097-00 White
6462 2 097-10 Red
6462 2 097-20 Green
Pack Quantity: 20
HIGHBAND Label Holder
Clear clip on label holders with paper labels supplied.
Can also be used on all Series 2, 10 pair modules.

Product Number: 6462 2 096-00
Pack Quantity: 10
page twenty one
IDENTIFICATIONOFPATCHCORDS
Description
HIGHBAND patch cords have contacts on both
sides of the printed circuit board. This allows the
same patch cord to be used on both the disconnect
modules i.e. HIGHBAND 8 and 10 and the patching
modules, i.e. HIGHBAND 16 and 20. Patch cord
wiring configurations are shown in figures 1 to 6
on the following page. High quality, flexible
Category 5e UTP cable is used in the manufacture
of these cords (except the one pair voice patch
cord which uses Category 3 cable).
Naming Convention
HIGHBAND8/16 2 OR 4PAIR PATCH CORD2M
Product
Family
HIGHBAND modules that
accessories can be used on
(e.g. HIGHBAND 8 and 16
modules). If these numbers do not
appear in the description then the
accessory can be used on all
HIGHBANDmodules
Numbers of pairs used depending on the
module the accessory is used on (i.e. 2 pair
for HIGHBAND 8 or 4 pair for HIGHBAND

16). The first digit indicates the width of
the plug shell (i.e. 2 pair wide)
Type of
Accessory
Length
1 2 3 4 5 6 7 81 2 3 4 5 6 7 8
Jack Positions
T568A Eight Position Jack
Pin/Pair Assignments
Pair 3
W-G G W-O BL W-BL O W-BR BR
LEGEND:
W = White
G = Green
O = Orange
BL = Blue
BR = Brown
Pair 1
Pair 2
Pair 4
Colour Codes for T568A Wiring Scheme
page twenty two
HIGHBAND
1 or 2 Pair
HIGHBAND 8/16
2 or 4 Pair to RJ45
HIGHBAND 8/16
2 or 4 Pair
Bottom Pair 1
Bottom Pair 4

Top
Pair 1
Bottom
Pair 2
Top
Pair 1
Bottom
Pair 2
Bottom Pair 4
Bottom Pair 1
Top Pair 3
Top Pair 2
Top Pair 2
Top Pair 3
HIGHBAND 8
4 Pair
HIGHBAND
1 Pair Voice
Pair 1
Top of
PCB
2 pole plug for
Series 2 modules
Bottom Pair 4
HIGHBAND 8
4 Pair to RJ45
PATCHCORDCONFIGURATIONS
Top
Pair 3
Bottom Pair 1

Top
Pair 2
Note: HIGHBANDpatch cords are compatible with both T568A and T568B wiring configurations.
page twenty three
INDEX
Introduction 2
Features and Benefits 3
Technical Specifications 3
The Industry’s Most Secure Connection 4
The HIGHBANDContact 4
Frequently Asked Questions 5
Designing Building and Floor Distributors 6
HIGHBAND and the TrueNet Solution 8
Consolidation Points 9
Installation Practices 10
Installation Procedures 11
Patch-By-Exception 12
Testing of HIGHBANDCircuits 13
Technology Comparisons 14
HIGHBANDProduct Range - Identification and Application 16
Identification of Patch Cords 21
Patch Cord Configuration 22
KRONEOFFICESWORLDWIDE
Document Created By
KRONE Australia Hold
Job No. 5334 11/00
KRONE AG
Beeskowdamm 3-11
D-14167 Berlin
Tel: +49 30 84 53 - 0

Fax: +49 30 84 53 -17 03
KRONE Argentina
KRONECOMUNICACIONES S.A
Villa de Luján 2250
1826 Lanús Este
Buenos Aires, Argentina
Tel: +54 11 4241 1665
Fax: +54 11 4249 5665
KRONE Australia
KRONE Australia Pty LImited
2 Hereford Street
Berkeley Vale NSW 2261
Tel: +61 2 4388 4422
Fax: +61 2 4388 4499
KRONE Austria
KRONEGesellschaft m.b.H.
Kroneplatz 1
2521 Trumau/NÖ
Tel: +43 2253 75 21
Fax: +43 2253 75 21 60
KRONE Brazil
KRONE Telecomunicacoes
Industria e Comercio Ltda.
Rua Helena, 335 - 2.andar
Vila Olimpia
04552-050 Sao Paulo
Tel. +55 11 38 42 41 32
Fax. +55 11 38 42 04 55
KRONE Chile
KRONE CHILE LTDA.

Camino Del Cerro Nro 4966
Huechuraba
Santiago De Chile
Tel: +56 2 740 0688
Fax: +56 2 740 0695
KRONE China
KRONE Communications (Shanghai)
Building 16, Lane 509, Shenqiang Rd
Xinzhuang Industrial Zone, Shanghai
PC: 201108 China
Tel: +86 21 6489 3680
Fax: +86 21 6489 2711
KRONE France
KRONE S.a.r.l.
Parc Saint Laurent
Immeuble Le Québec
54, Route de Sartrouville
78232 Le Pecq Cedex
Tel: +33 1 301 54 515
Fax: +33 1 301 54 510
KRONE Greece
KRONE HELLAS S.A.
133A, Pentelis Av
152 34 Halandri - Athen
Tel: +30 1 684 14 12
Fax: +30 1 683 35 16
KRONE Hong Kong
KRONE Communications Ltd.
13 Flr, Gitic Centre
28 Queen’s Road East

Wanchai, Hong Kong
Tel: +852 2865 48 88
Fax: +852 2861 14 44
KRONE India
KRONE Communications Ltd.
Hosto Centre, 3rd & 4th Floors
No. 43 Milllers Road
Bangalore - 560 052
Tel: +91 80 225 19 04
Fax: +91 80 225 16 93
KRONE Indonesia
PT KRONE INDONESIA
Gedung TIFA, Lt. 9
Jl. Kuningan Barat No. 26
Jakarta 12710
Tel. +62 21 520 02 31
Fax. +62 21 522 13 12
KRONE Italy
KRONE Italia S.r.l.
Zona Industriale Noghere
Via Petronio 11
34015 Muggia (Trieste)
Tel: +39 040 23 23 46
Fax: +39 040 23 19 31
KRONE Japan
KRONE Japan Office
Tsukiji MT Building, 4F
2-11-9 Tsukiji
Chuo-Ku
Tokyo 104-0045

Tel: +81 3 3549 03 11
Fax: +81 3 5565 28 58
KRONE Mexico
KRONE Comunicaciones S.A. de C.V.
Tintoreto No. 43
Col. Mixcoac
Mexico, D.F. - C.P. 03910
Tel: +52 5 611 86 90
Fax. +52 5 563 31 58
KRONE New Zealand
KRONE (N.Z.) Technique Ltd
Cnr The Esplanade and Nevis Street
Petone, Wellington
New Zealand
Tel: +64 4 576 92 13
Fax: +64 4 576 92 43
KRONE Norway
KRONE AS
Postboks 154, Kjelsas
0411 Oslo
Tel: +47 23 007 73 30
Fax: +47 22 95 08 28
KRONE PHILIPPINES
KRONE Communications Inc.
27 Floor, Unit D,
Rufino Pacific Towers,
Ayala Avenue, Corner Herrera Street
Makati City, 1200 Philippines
Tel. +632 848 99 01
Fax. +632 84 89-904

KRONE Russia
ZAO KRONE
Chaussee Freser, 17
109202 Moscow
Tel: +7 501 967 13 95
Fax: +7 501 967 13 85
KRONE Singapore
KRONE Far East Pte, Ltd.
70 Bendemeer Rd #06 to 02
Hiap Huat House
Singapore 339940
Tel: +65 538 86 28
Fax: +65 538 86 36
KRONE South Africa
KRONE (Africa) (Pty.) Ltd.
59 Kyalami Boulevard
Kyalami Business Park
Midrand, 1684
Tel: +21 11 466 33 33
Fax: +27 11 466 33 00
KRONE Spain
KRONE Comunicaciones S.A.
Fábrica y oficinas
Poligno Industrial Prado del Espino
Calle Forjadores, manzana 1, parcela 2B
28660 Boadillo del Monte
Madrid
Tel: +34 91 341 42 22
Fax: +34 91 341 63 99
KRONE Thailand

KRONE Technique (Thailand) Co.,Ltd.
14th Floor, Unit 02,
Chartered Square Building
152 North Sathorn Road, Silom
Bangrak, Bangkok 10500
Tel: +662 637 83 01
Fax: +662 637 83 06
KRONE Turkey
KRONE A.S.
Haberler Sokak No. 7
Gazeteciler Sitesi
80300 Esentepe-Istanbul
Tel. +90 212 274 12 82
Fax: +90 212 211 26 27
KRONE U.K.
KRONE (U.K.) Technique Ltd.
Runnings Road
Kingsditch Trading Estate
Cheltenham, Glos. GL51 9NQ
Tel: +44 1242 26 44 00
Fax: +44 1242 26 44 88
KRONE USA
KRONE Inc.
6950 South Tucson Way Suite R
Englewood, Colorado 80112
Tel: +1 303 790 26 19
Fax: +1 303 790 21 17

×