Tải bản đầy đủ (.pdf) (26 trang)

Tài liệu Value-Added Module System Chassis used in Non-ADC Optical Distribution Frame pdf

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (3.36 MB, 26 trang )

10/03 • 100571
600 mm Products
53
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
4-Inch Chassis – 6 Single Plug-In Modules
The 4-inch VAM chassis fits into any 23-inch rack
mounting environment. It accommodates a maximum of
six plug-in modules, six bulkhead plates, six blank panels
or any combination thereof.
Not for use in ADC’s FDF
FVM-23X400
Description
Unloaded chassis for 23
" racks
Catalog Number*
FVM-23X400
Dimensions (HxWxD)
4.0" x 23" x 12"
(10.16 x 58.42 x 30.48 cm)
Ordering Information
3.5-Inch Chassis – 4 Single Plug-In Modules
The 3.5-inch VAM chassis fits into any 19-inch rack
mounting environment. It accommodates a maximum of
four plug-in modules, four bulkhead plates, four blank
panels or any combination thereof. Adjustable mounting
brackets are provided for 23-inch mounting environments.
Not for use in ADC’s FDF
FVM-19X350
Description
Unloaded chassis for 19" or 23" racks
Dimensions (HxWxD)


3.5" x 19" or 23" x 12"
(8.89 x 48.26 or 58.26 x 30.48 cm)
Ordering Information
1.75-Inch Chassis – 2 Single Plug-In Modules
The 1.75-inch VAM chassis fits into any 19-inch rack
mounting environment. It accommodates a maximum of
two plug-in modules, two bulkhead plates, two blank
panels or any combination thereof. Adjustable mounting
brackets are provided for 23-inch mounting environments.
Not for use in ADC’s FDF
FVM-19X175
Description
Unloaded chassis for 19" or 23" racks;
no front door
Dimensions (HxWxD)
1.75" x 19" or 23" x 12"
(4.45 x 48.26 or 58.26 x 30.48 cm)
Ordering Information
Catalog Number*
FVM-19X350
Catalog Number*
FVM-19X175
Value-Added Module System
Chassis used in Non-ADC Optical Distribution Frame
* This product is available in black; for this option, simply add “-BK” to the end of the catalog number.
Please contact the Technical Assistance Center with any questions.
10/03 • 100571
600 mm Products
54
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42

Value-Added Module System
Introduction
ADC’s Value-Added Connector Module System (VAM System) adds flexibility and functionality to the
optical transport system by enabling telecommunications service providers to easily incorporate optical
components into the network. This versatile platform lays the foundation for the fiber distribution frame
of the future.
The VAM System consists of a variety of chassis and optical components that fit into all existing ADC fiber
distribution frames and various other mounting environments. Optical components may include:
• Splitters
• Wavelength division multiplexers (WDMs)
• Variable attenuators
Features and Benefits
VAM chassis and modules available for all ADC fiber frames
One-stop shop for complete optical transport system requirements
Monitor testing
Enables providers to troubleshoot networks without forcing disruption of service
Enclosed plug-in modules
Optical components are protected from physical and environmental damage
Angled retainers
Maintains minimum bend radius of fiber patch cords
Horizontal mounted plug-in modules
Modules can be added or removed from the chassis without interfering with existing terminated
patch cords
Universal mounted plug-in modules
No need to order different part numbers for left side or right side mounted modules
Extensive product labeling
Customers have all the information required for installation and maintenance without referring
to the user manual or drawings
Flexible platform
Modules can be created for new applications quickly and easily to meet customer requirements

Module labeling system
Schematics are marked on peel-off labels that can be attached to the chassis designation
labeling system
Custom configurations
Custom splitter configurations available upon request, contact ADC
Standard VAM
Module
WideVAM

Module
OMX

VAM
Module
LGX-compatible
VAM module
10/03 • 100571
600 mm Products
55
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Value-Added Module System
Splitter Modules
Catalog Number

Configurations
VAM Style
Input front, output front
Input rear, output front
2
5

Split Ratio**
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
2x2
1x3
1x4
1x5
1x6
1x7
1x8
1x9
1x10
1x11
1x12
1x13
1x14
1x15
1x16
1x32
50/50

55/45
60/40
65/35
66.6/33.3
70/30
75/25
80/20
85/15
90/10
95/5
99/1
50/50
33/33/33
25/25/25/25
20/20/20/20/20
16.6/16.6/16.6/
16.6/16.6/16.6
14.3/14.3/14.3/
14.3/14.3/14.3/14.3
12.5/12.5/ 12.5
11.1/11.1/11.1/ 11.1
10/10/10/ 10
9.1/9.1/9.1/ 9.1
8.33/8.33/8.33/ 8.33
7.7/7.7/7.7/ 7.7
7.14/7.14/7.14/ 7.14
6.66/6.66/6.66/ 6.66
6.25/6.25/6.25/ 6.25
3.125/3.125/3.125/ 3.125
OR

2000
2100
2200
2300
2350
2400
2500
2600
2700
2800
2900
2950
2030
3900
4900
5300
6000
7000
8000
9000
A110
B111
C112
D113
E114
F115
G116
M132
Number of Splitters
Single splitter

Dual splitter (2)
Triple splitter (3)
A
B
C
Output Connector/Adapter
Singlemode
2U
2A
4U
7U
7A
8A
LA
LU
KU
00
FC ultra polish
FC angled polish
ST
®

ultra polish
SC

ultra polish
SC

angled polish
E-2000 angled polish

LX.5
®
angled polish
LX.5
®
ultra polish
LC ultra polish
Bare fiber
Multimode**
2M
2N
5F
5U
9A
9B
LM
LN
PM
00
FC 62.5/125
FC 50/125
ST
®

50/125
ST
®

62.5/125
SC 50/125

SC 62.5/125
LX.5
®
62.5/125
LX.5 50/125
LC 62.5/125
Bare fiber
Multimode**
OR
2M
2N
5F
5U
9A
9B
LM
LN
PM
00
FC 62.5/125
FC 50/125
ST
®
50/125
ST
®

62.5/125
SC 50/125
SC 62.5/125

LX.5
®
62.5/125
LX.5 50/125
LC 62.5/125
Bare fiber
Input Connector/Adapter
Singlemode
FC ultra polish
FC angled polish
ST
®
ultra polish
SC

ultra polish
SC

angled polish
E-2000 angled polish
LX.5
®
angled polish
LX.5
®
ultra polish
LC ultra polish
Bare fiber
2U
2A

4U
7U
7A
8A
LA
LU
KU
00
Standard VAM for
FL2000 and non-ADC
frames
WideVAM

for FL2000
WideVAM

for
non-ADC frames
MiniVAM for Next
Generation Frames*
For OMX

600 frames
For LGX-compatible
frames
VSM-
FLVW-S
VSMW-
NGF-V
MXV-

VLM-
Input Pigtail Length
Example (In Meters):
01 = 1 m
10 = 10 m
00 = Adapters only on
input and output ports
Output Pigtail Length
*MiniVAMs are not available with split ratios above 1x8 nor can they be configured with three splitters.
They are not available with E-2000 connectors/adapters
**VAMs with multimode connectors/adapters can only be configured with 90/10 or uniform split (50/50) ratios.
See page 58 for configuration illustrations. Please contact ADC for specifications and available split ratios.
10/03 • 100571
600 mm Products
56
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Value-Added Module System
Wavelength Division Multiplexer Modules
A Single
Module
Configuration
Catalog Number
Mux Port Connector/Adapter
2U
2A
4U
7U
7A
8A
LA

LU
KU
00
FC ultra polish
FC angled polish
ST
®

ultra polish
SC

ultra polish
SC

angled polish
E-2000 angled polish
LX.5
®
angled polish
LX.5
®
ultra polish
LC ultra polish
Bare fiber
Demux Port Pigtail Length
Configuration
VAM Style
Unidirectional multiplexer
Unidirectional demultiplexer
Bidirectional λ

1
Tx/λ
2
Rx
Bidirectional λ
1
Rx/λ
2
Tx
45 dB isolation, pass 1310
45 dB isolation, pass 1550
(Dual only) unidirectional
multiplexer, unidirectional
demultiplexer**
(Dual only) bidirectional
λ
1
Tx/λ
2
Rx, bidirectional
λ
2
Tx/λ
1
Rx
A
C
E
G
J

K
L
M
WDM Type (λ
1
; λ
2
)
B Dual
C Triple
1 Standard
Isolation*
2 High
3 Very High
Mux Port Pigtail Length
Example (In Meters):
01 = 1 m
10 = 10 m
00 = Adapters only on mux
and demux ports
**WDM Type “L” includes (1) unidirectional
multiplexer (standard isolation) and
(1) unidirectional demultiplexer (isolation
specified by next character)
*MiniVAMs are not available with E-2000
connectors/adapters
Wavelength
1310 (λ
1
)/1550 (λ

2
)
1533 (λ
1
)/1557 (λ
2
)
1310/1533/1557
1550 (λ
1
)/1625 (λ
2
)
1310 (λ
1
)/1625 (λ
2
)
A
B
C
E
F
2
5
MUX front, DEMUX front
MUX rear, DEMUX front
Standard VAM for
FL2000 and
non-ADC frames

WideVAM

for
FL2000
WideVAM

for
non-ADC frames
MiniVAM for Next
Generation Frames*
For OMX


600 frames
For LGX-
compatible frames
WDM-
FLVW-W
WDMW-
NGF-W
MXV-W
VLM-W
Demux Port
Connector/Adapter
2U
2A
4U
7U
7A
8A

LA
LU
KU
00
FC ultra polish
FC angled polish
ST
®

ultra polish
SC

ultra polish
SC

angled polish
E-2000 angled polish
LX.5
®
angled polish
LX.5
®
ultra polish
LC ultra polish
Bare fiber
In the ordering charts, the abbreviation “mux” references the multiplexed
side of the WDM, the side where two optical signals co-exist on one fiber.
The abbreviation “demux” references the demultiplexed side of the WDM,
the side where each signal appears on its own fiber. Both unidirectional
and bidirectional WDMs are available as shown below.

1310
1310 1550
1550
1310
1310 1550
1550
UNIDIRECTIONAL MULTIPLEXER
BIDIRECTIONAL TRANSMISSION
DEMUX MUX
1310
1310 1550
1550
MUX DEMUX
DEMUX MUX
1310
1310 1550
1550
MUX
DEMUX
UNIDIRECTIONAL DEMULTIPLEXER
See page 58 for configuration instructions. Please contact ADC for specifications.
10/03 • 100571
600 mm Products
57
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Value-Added Module System
Monitor Modules
Catalog Number
Input pigtail length
Example (in meters):

01 = 1 m
10 = 10 m
000 = Adapters only
on input, output and
monitor ports
Monitor pigtail length
Output pigtail length
Splitter Ratio**
A
B
C
E
F
H
J
K
90/10
95/05
50/50
80/20
75/25
70/30
60/40
99/01
Module Style
Dual monitor cross-connect
with attenuator***
Customer premises
Dual monitor cross-connect
Dual monitor cross-connect

1
B
D
J
Output Connector
Type Singlemode
2U
2A
4U
7U
7A
8A
LA
LU
KU
00
FC ultra polish
FC angled polish
ST
®
ultra polish
SC ultra polish
SC angled polish
E-2000 angled polish
LX.5
®
angled polish
LX.5
®
ultra polish

LC ultra polish
Bare fiber
2M
2N
5F
5U
9A
9B
LM
LN
PM
00
FC 62.5/125
FC 50/125
ST
®
50/125
ST
®
62.5/125
SC 50/125
SC 62.5/125
LX.5
®
62.5/125
LX.5
®
50/125
LC 62.5/125
Bare fiber

Multimode**
Monitor Connector
Type Singlemode
2U
2A
4U
7U
7A
8A
LA
LU
KU
00
FC ultra polish
FC angled polish
ST
®
ultra polish
SC ultra polish
SC angled polish
E-2000 angled polish
LX.5
®
angled polish
LX.5
®
ultra polish
LC ultra polish
Bare fiber
OR

OR
2M
2N
SF
5U
9A
9B
LM
LN
PM
00
FC 62.5/125
FC 50/125
ST
®
50/125
ST
®
62.5/125
SC 50/125
SC 62.5/125
LX.5
®
62.5/125
LX.5
®
50/125
LC 62.5/125
Bare fiber
Multimode**

Input Connector
Type Singlemode
VAM Style
2U
2A
4U
7U
7A
8A
LA
LU
KU
00
FC ultra polish
FC angled polish
ST
®
ultra polish
SC ultra polish
SC angled polish
E-2000 angled polish
LX.5
®
angled polish
LX.5
®
ultra polish
LC ultra polish
Bare fiber
OR

2M
2N
5F
5U
9A
9B
LM
LN
PM
00
FC 62.5/125
FC 50/125
ST
®
50/125
ST
®
62.5/125
SC 50/125
SC 62.5/125
LX.5
®
62.5/125
LX.5
®
50/125
LC 62.5/125
Bare fiber
Multimode**
1

2
3
1 circuit
2 circuits
3 circuits
Number of
Circuits per VAM
*** This style cannot be used in
NGF-M modules.
Standard VAM for
FL2000 and
non-ADC frames
WideVAM

for
FL2000
WideVAM

for
non-ADC frames
MiniVAM for Next
Generation Frames*
For OMX

600 frames
For LGX-
compatible frames
VMM-
FLVW-M
VMMW-

NGF-M
MXV-M
VLM-M
*MiniVAMs are not available with E-2000 connectors/adapters
**VAMs with multimode connectors/adapters can only be configured with 90/10 or uniform split (50/50) ratios.
See page 58 for configuration illustrations. Please contact ADC for specifications and available split ratios.
10/03 • 100571
600 mm Products
58
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Value-Added Module System
IN
OUT
REAR FRONT
Connectorized
pigtail to OSP
port on the
fiber frame
Adapter to
attach patch
cord or pigtail
to OSP port
Adapter to attach
patch cord to
equipment
SPLITTER
COMPONENTS
Connectorized
pigtail (3 mm
jacketed) to

equipment
or to port
on frame
Stub fiber
input spliced
to equipment
or OSP fibers
(2 mm jacketed)
2
IN OUT
FRONTREAR
OUTPUT
INPUT
OUTPUT
Input Front,
Output Front
1 x N
IN OUT
Input Rear,
Output Front
5
REAR FRONT
OUTPUT
OUTPUT
INPUT
1 x N
Mux Rear,
Demux Front
5
REAR FRONT

2
FRONTREAR
Demux
Mux
Demux
Demux
Demux
Mux
Mux Front,
Demux Front
WDM
WDM
Dual Monitor
Cross-Connect
D
Tx
Rx
Tx MON
Rx MON
Tx
Rx
SPLITTER
90%
10%
SPLITTER
90%
10%
Customer Premises
Monitor Module
B

SRC Rx
CUST MON
SRC MON
CUST Rx
SRC Tx
CUST Tx
1 x 2
SPLITTER A
1 x 2
SPLITTER B
XX%
XX%
XX%
XX%
Dual Monitor Cross-Connect
with Variable Attenuator
1
Tx
Rx Mon
Tx Mon
Tx
Rx
1 x 2
1 x 2
Rx
VAR
ATTN
Dual Monitor
Cross-Connect
J

Tx
Mon Tx
Mon Rx
Rx
Rx SRC
Tx SRC
1 x 2
1 x 2
Splitter Modules
WDM Modules
Monitor Modules
REAR FRONT
Connectorized
pigtail
Adapter port
Adapter
port
WDM
Connectorized
pigtail
(3 mm
jacketed)
Bare pigtail
(2 mm
jacketed)
10/03 • 100571
600 mm Products
59
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Bulkhead Plates and Blanks

ADC
ADC
ADC
ADC
VAM-BLNK
VAM-6PBX
Description
Blank plate
Six position bulkhead plates loaded with:
Singlemode
FC adapters
FC angled polish adapters
ST
®
adapters
SC adapters
SC angled polish adapters
(3) duplex SC adapters
E-2000 angled polish APC adapters
Multimode
ST
®
adapters
SC adapters
(3) duplex SC adapters
Catalog Number*
VAM-BLNK
VAM-6PB2
VAM-A6PB2
VAM-6PB4

VAM-6PB7
VAM-A6PB5
VAM-D6PB7
VAM-A6PB8
VAM-6PB5
VAM-6PB9
VAM-D6PB9
Ordering Information
Terminators
Terminator plugs should be ordered for each unterminated leg on ultra polish adapter ports. For
configurations with pigtails an adapter is also required.
Description
FC connector
ST
®
connector
SC connector
Catalog Number
FOC-TERMFC-P
FOC-TERMST-P
FOC-TERMSC-P
Ordering Information
* These products are available in black; for this option, simply add “-BK” to the end of the catalog number.
Please contact the Technical Assistance Center with any questions.
Value-Added Module System
10/03 • 100571
600 mm Products
60
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Singlemode Wideband Optical Splitter Specifications

Other splitter configurations are available. Please call ADC Technical Assistance Center.
2000
2100
2200
2300
2350
2400
2500
2600
2700
2800
2900
2950
2030
3900
4900
5300
6000
7000
8000
9000
A110
B111
C112
D113
E114
F115
G116
M132
1x2

1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
1x2
2x2
1x3
1x4
1x5
1x6
1x7
1x8
1x9
1x10
1x11
1x12
1x13
1x14
1x15
1x16
1x32
50/50
55/45
60/40

65/35
66.6./33.3
70/30
75/25
80/20
85/15
90/10
95/5
99/1
50/50
33/33/33
25/25/25/25
20/20/20/20/20
16.6/16.6/ . . . 16.6
14.3/14.3/ . . . /14.3
12.5/12.5/ . . .12.5
11.1/11.1/ . . . /11.1
10/10/10 . . . /10
9.1/9.1/ . . . /9.1
8.3/8.3/ . . . /8.3
7.7/7.7/ . . . /7.7
7.14/7.14/ . . . /7.14
6.66/6.66/ . . . /6.66
6.25/6.25/ . . . 6.25
3.13/3.13/ . . . 3.13
3.7/3.7
3.2/4.1
2.7/4.7
2.3/5.3
2.2/5.5

2.0/6.0
1.6/6.8
1.3/7.8
1.0/9.2
.8/11.2
.5/14.4
0.3/22.5
3.7/3.7
5.9/5.9/5.9
7.4/7.4/7.4/7.4
8.6/8.6/8.6/8.6/8.6
9.8/9.8/9.8/ . . ./9.8
10.6/10.6/ . . . /10.6
11.3/11.3/ . . . /11.3
11.5/11.5/ . . . /11.5
12.1/12.1/ . . . /12.1
13.1/13.1/ . . . /13.1
13.3/13.3/ . . . /13.3
13.8/13.8/ . . . /13.8
13.8/13.8/ . . . /13.8
14.5/14.5/ . . . /14.5
14.9/14.9/ . . . 14.9
18.5/18.5/ . . . 18/5
3.1/3.1
2.7/3.6
2.3/4.1
2.0/4.7
1.9/5.0
1.7/5.4
1.4/6.2

1.1/7.1
.8/8.4
.6/10.2
.4/13.2
NA/NA
3.1/3.1
5.0/5.0/5.0
6.2/6.2/6.2/6.2
7.3/7.3/7.3/7.3/7.3
8.1/8.1/8.1 . . . /8.1
8.9/8.9/ . . . /8.9
9.5/9.5/ . . ./9.5
9.9/9.9/ . . . /9.9
10.4/10.4/ . . . /10.4
10.9/10.9/ . . . /10.9
11.3/11.3/ . . . /11.3
11.6/11.6/ . . . /11.6
11.8/11.8/ . . . /11.8
12.4/12.4/ . . . /12.4
12.6/12.6/ . . . 12.6
15.8/15.8/ . . . 15.8
Splitter
Number
Splitter
Type
Splitter
Ratio
Maximum
Insertion Loss*
Typical

Insertion Loss*
* Does not include connector losses. See table on the following page or contact the ADC Technical
Assistance Center.
Maximum Insertion Loss
Maximum insertion loss is the upper limit of insertion loss for the coupler and applies over the entire
wavelength range specified in the bandpass.
Typical Insertion Loss
Typical insertion loss is the expected insertion loss value for the coupler measured at the specified
center wavelength (i.e. 1310 nm and/or 1550 nm).
Value-Added Module System
10/03 • 100571
600 mm Products
61
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
MATERIAL
Fiber:
Jacket:
Housing:
OPTICAL
Bandpass
Wavelength 1:
Wavelength 2:
Directivity:
Reflectance:
Polarization Stability:
MECHANICAL
Cable Retention:
Flex:
Twist:
Vibration:

Impact:
Flammability:
ENVIRONMENTAL
Humidity:
Thermal Aging:
Temperature Cycling:
Corning SMF-28
0.900 mm hytrel tube
Stainless steel tube
1260/1360 nm
1430/1580 nm
55 dB minimum
< -55 dB
.5 dB maximum
.45 kg (1.0 lb.) maximum for .25 mm and .900 mm fiber,
1 kg (2.2 lbs.) maximum for cabled fiber assemblies
300 cycles; .45 kg (1.0 lb.) maximum load (fiber cable only)
100 cycles; .45 kg (1.0 lb.) maximum load (fiber cable only)
10-55 Hz per FOTP II condition I
8 drops from 1.5 meters
All materials used in fabrication of coupler housing meet
UL 94, Level V-I requirements
336 hours, 60°C at 95% relative humidity
336 hours, 85°C
336 hours, -40°C to 85°C
Singlemode Optical Splitter Specifications
Value-Added Module System
Singlemode Optical Connector Specifications
Ultra Polish PC Connectors
Angled Polish Connectors

INSERTION LOSS
(dB)
0.3 dB maximum
0.1 dB typical
0.5 dB maximum
0.1 dB typical
RETURN LOSS
(dB)
57 dB minimum
65 dB minimum
10/03 • 100571
600 mm Products
62
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Singlemode WDM Specifications
MATERIAL
Fiber: Corning SMF-28
Jacket: 0.900 mm
OPTICAL
Uniformity: 1.0 Log2N (where N = number of channels)
Polarization Stability: 0.5 dB maximum
Bandpass: (see table below)
Insertion Loss: (see table below)
Reflectance: < -55 dB
Isolation
Near End: 55 dB
Far End: (see table below)
MECHANICAL
Cable Retention:
Flex: 45 kg (1.0 lb.) maximum for .250 mm and .900 mm fiber;

Twist: 1.0 kg (2.2 lbs.) maximum for cabled fiber assemblies
Vibration: 10-55 Hz per FOTP II condition I
Impact: 100 cycles; 8 drops from 1.5 meters
Flammability: All materials used in fabrication of the coupler housing meet
UL 94, Level V-I requirements
ENVIRONMENTAL
Humidity Resistance: 336 hours, 60°C at 95% relative humidity
Thermal Aging: 336 hours, 85°C
Temperature Cycling: 336 hours, -40°C to 85°C
Multiplexer/Demultiplexer:
High Isolation Demultiplexer:
Very High Isolation
Demultiplexer:
Wavelength Filters:
1310/1550 nm
MAXIMUM
INSERTION LOSS* (dB)
0.3
0.7
1.0
0.3
MINIMUM
ISOLATION (dB)
15
30
45
15
PASSBAND
(nm)
1310 ± 20 nm and 1550 ± 20 nm

1310 ± 20 nm and 1550 ± 20 nm
1310 ± 20 nm and 1550 ± 20 nm
1310 ± 20 nm and 1550 ± 20 nm
Unidirectional Multiplexer:
High Isolation
Undirectional Multiplexer
or Bidirectional
Multiplexer/Demultiplexer:
Very High Isolation
Undirectional Multiplexer
or Bidirectional
Multiplexer/Demultiplexer:
Filter Passing 1533 nm:
Filter Passing 1557 nm:
1533/1557 nm
MAXIMUM
INSERTION LOSS* (dB)
0.9
1.8
2.1
0.9
0.9
MINIMUM
ISOLATION (dB)
N/A
20
35
13
13
PASSBAND

(nm)
1533 ±3 and 1557 ±3 nm
1533 ±3 and 1557 ±3 nm
1533 ±3 and 1557 ±3 nm
1533 ±3 nm
1557 ±3 nm
* Maximum Insertion Loss does not include connector loss.
Value-Added Module System
10/03 • 100571
600 mm Products
63
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
Introduction
ADC’s fiber management trays provide a flexible, economical approach to handling your network’s most
vital elements by offering four different designs. Termination, termination/splicing, termination/storage,
and slack storage designs are offered with ADC’s modular, all-front access trays.
Features
All-Front Access Design
Sliding radius limiters provide ultimate fiber
management by addressing one of the most critical
elements of fiber cable management: bend radius
protection. As fibers leave the tray, a specially
designed bell-shaped exit point provides maximum
edge protection.
By controlling the movement of fibers within the
tray, error-proof slack loop management is
maintained, ensuring 30 mm bend radius protection
within the tray. This is crucial in ensuring no fiber
breaks, which cause service failures and increase

network operations costs.
Sliding adapter packs allow easy access for
connecting jumpers and cleaning connectors,
ensuring that any fiber can be installed or removed
without inducing a macrobend on an adjacent fiber.
That can mean the difference between a network
reconfiguration time of 20 minutes per fiber and one
of over 90 minutes per fiber.
These trays are lockable, further ensuring the
integrity of the fibers by greatly reducing the chance
for accidents.
Modular Design
The value of a single interface for performing
multiple tasks in your network cannot be denied. By
employing a one-rack-unit modular tray, network
technicians have ready access to terminating,
splicing, and storing fiber. This one-stop
management approach means time saved and
value added.
10/03 • 100571
600 mm Products
64
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
24-Termination Only
32-Termination Only
Fiber Management Tray
1 Rack Unit – Termination Only
Catalog Number
FMT-D __ __ 0 __ 0 __ 0 __ - __ __ __ __
Drawer Configuration

Connector/Adapter Style
Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2
24
32
Mounting Style
1
A 19"/5" recess
C 19"/2.2" recess
E 19"/40 mm recess
2
F ETSI/40 mm recess
2
Number of Ports
Faceplate Color
P Putty
Adapters Loaded
A Adapters loaded
0 No adapters
1
All 19" mounting brackets are reversible and can
mount in EIA or WECO racks.
2
40 mm recess FMTs are equipped with a special
trumpet sliding radius limiter. Other mounting styles
cannot be used in 40 mm recess applications.
The termination-only fiber management tray provides termination for 24 or 32 fibers in an all-front-access
design. This tray mounts in 19-inch, 23-inch, or ETSI racks. Sliding radius limiters provide cable

management for incoming and outgoing fibers.
RT Termination only
Multimode
5ST
®
9SC
Singlemode
1 FC hybrid (FC connector on front;
SC connector on back of bulkhead)
2 FC ultra polish
3ST
®
hybrid (ST
®
connector on front;
SC connector on back of bulkhead)
4ST
®
ultra polish
7 SC ultra polish
F FC angled polish
J SC angled polish
K E-2000 angled polish
L FC with zirconia adapter
M MTRJ feedthrough adapter
N SC with zirconia adapter
PST
®
with zirconia adapter
10/03 • 100571

600 mm Products
65
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
1 Rack Unit – Termination and Splice
12-Termination/Splice
(right splice entry)
24-Termination/Splice
(right splice entry)
24-Termination/Splice
(right splice entry)
24-Termination/Splice
(left splice entry)
Catalog Number
FMT - D __ __ 0 __ 0 __ __ __ - __ __ __ __
Configuration
TL Term splice with splice tray
(left splice entry)
TR Term splice with splice tray
(right splice entry)
Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2
Mounting Style
1
A 19"/5" recess
C 19"/2.2" recess
E 19"/40 mm recess
2

F ETSI/40 mm recess
2
Number of Ports
12
16
24
Cable or Adapter Type
A Adapters only
0 No adapters
C Multimode pigtails (50/125)
K Multimode pigtails (62.5/125)
U Singlemode Maxi-Strip pigtails
R Singlemode ribbon pigtails
Chip Style (mini splice tray)
0N/A
2 Heat shrink
3 Mechanical
Faceplate Color
P Putty
Connector/Adapter Style
Multimode
5ST
®
9SC
Singlemode
1 FC hybrid (FC connector on front;
SC connector on back of bulkhead)
2 FC ultra polish
3ST
®

hybrid (ST
®
connector on front;
SC connector on back of bulkhead)
4ST
®
ultra polish
7 SC ultra polish
F FC angled polish
J SC angled polish
K E-2000 angled polish
L FC with zirconia adapter
N SC with zirconia adapter
PST
®
with zirconia adapter
1
All 19" mounting brackets are reversible and can
mount in EIA and WECO racks.
2
40 mm recess FMTs are equipped with a special
trumpet sliding radius limiter. Other mounting styles
cannot be used in 40 mm recess applications.
The termination and splice tray terminates and
splices 12, 16, or 24 fibers in an all-front-access
design. This tray mounts in 19-inch, 23-inch, or
ETSI racks. Sliding radius limiters provide cable
management for incoming and outgoing fibers.
Panels loaded with pigtails come with color-coded
900 micron pigtails.

10/03 • 100571
600 mm Products
66
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
1 Rack Unit – Termination and Storage
12-Termination/Storage
(universal storage)
16-Termination/Storage
(universal storage)
24-Termination/Storage
(left storage)
24-Termination/Storage
(right storage)
Catalog Number
FMT-D __ __ 0 __ 0 __ 0 __ - __ __ __ __
Configuration
SL Termination/storage (left storage)
SR Termination/storage (right storage)
ST Termination/storage (universal storage)
Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2
Mounting Style
1
A 19"/5" recess
C 19"/2.2" recess
E 19"/40 mm recess
2

F ETSI/40 mm recess
2
Number of Ports
12 Available with ST
configuration only
16 Available with ST
configuration only
24 Available with SR and SL
configurations only
Faceplate Color
P Putty
Adapters Loaded
A Adapters loaded
0 No adapters
Connector/Adapter Style
Multimode
5ST
®
9SC
Singlemode
1 FC hybrid (FC connector on front; SC
connector on back of bulkhead)
2 FC ultra polish
3ST
®
hybrid (ST
®
connector on front; SC
connector on back of bulkhead)
4ST

®
ultra polish
7 SC ultra polish
F FC angled polish
J SC angled polish
K E-2000 angled polish
L FC with zirconia adapter
M MTRJ feedthrough adapters
N SC with zirconia adapter
PST
®
with zirconia adapter
1
All 19" mounting brackets are reversible and can
mount in EIA and WECO racks.
2
40 mm recess FMTs are equipped with a special
trumpet sliding radius limiter. Other mounting styles
cannot be used in 40 mm recess applications.
The termination and storage tray terminates and stores 12, 16,
or 24 fibers in an all-front-access design. This tray mounts in
19-inch, 23-inch, or ETSI racks, while sliding radius limiters
provide cable management for incoming and outgoing fibers.
10/03 • 100571
600 mm Products
67
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
1 Rack Unit – Slack Storage Panels
Catalog Number

FMT - D __ __ 0 0 0 00 __ - __ 00 __
Drawer Configuration
BS Bulk storage
DS Discrete storage
Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2
Mounting Style
1
A 19"/5" recess
C 19"/2.2" recess
E 19"/40 mm recess
2
F ETSI/40 mm recess
2
Faceplate Color
P Putty
Bulk/Storage Drawer
Discrete/Storage Drawer
Capacity
Slack storage type 3 mm cable 2 mm cable 1.7 mm cable
Bulk 32 cables, 2.5 m each 48 cables, 2.5 m each 60 cables, 4 m each
Discrete 16 cables 1.7 m each 16 cables, 2 m each 16 cables 2.5 m each
1
All 19" mounting brackets are reversible
and can mount in EIA and WECO racks.
2
40 mm recess FMTs are equipped with a
special trumpet sliding radius limiter. Other

mounting styles cannot be used in 40 mm
recess applications.
The slack storage tray offer bulk storage for up to 60 fibers, and discrete slack storage for up to 16 fibers.
This all-front-access tray mounts in 19-inch, 23-inch, or ETSI racks. Sliding radius limiters provide cable
management for incoming and outgoing fibers.
10/03 • 100571
600 mm Products
68
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Splicing Only
Splicing Only
Fiber Management Tray
1 Rack Unit – Splicing Only
Catalog Number
FMT - DAS0000 __ __ - __ __ __ __
Mounting Style
1
A 19"/5" recess
C 19"/2.2" mm recess
E 19"/40 mm recess
2
F ETSI/40 mm recess
2
Faceplate Color
P Putty
Number of Splices/Capacity
12 1 tray
24 2 trays
Splice Type
0 None

2 Heat shrink
3 Mechanical
Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2
1
All 19" mounting brackets are
reversible and can mount in EIA
and WECO racks.
2
40 mm recess FMTs are equipped
with a special trumpet sliding
radius limiter. Other mounting
styles cannot be used in 40 mm
recess applications.
10/03 • 100571
600 mm Products
69
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
1 Rack Unit – Termination and Splice Fixed Bulkhead
This configuration features fixed bulkhead style adapter plates and accommodates singlemode SC (ultra
polish and angled), E-2000, LC and LX.5
®
, as well as multimode SC, LC, and LX.5 adapters. The tray can be
ordered with adapters only, or with pigtails.
Catalog Number
FMT-D __ __ 0 __ 0 __ __ __ - __ __ __ __
Configuration

TW Termination/splice with bulkhead
plate (right splice entry)
TX Termination/splice with bulkhead
plate (left splice entry)
Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2
Mounting Style
3
A 19"/5" recess
C 19"/2.2" recess
E 19"/40 mm recess
4
F ETSI/40 mm recess
4
Faceplate Color
P Putty
Splice Type
0 None
2 Heat shrink
3 Mechanical
Connector/Adapter Style
Multimode
9SC
YLX.5
®
6LC
Singlemode
7 SC ultra polish

J SC angled polish
K E-2000 angled polish
8LC
XLX.5
®
Adapters Loaded
1
OR
A Adapters only
0 No adapters
Pigtail Type
2
U Singlemode Maxi-Strip pigtails
K Multimode pigtails (62.5/125)
C Multimode pigtails (50/125)
Number of Ports with Adapters
1
OR
01 24 Adapters only
Number of Pigtails
2
08 8 pigtails
12 12 pigtails
16 16 pigtails
24 24 pigtails
1
When ordering FMTs with adapters only, enter number
of adapters (00 to 24).
2
FMTs can be ordered with 8, 12, 16 and 24 pigtails only.

3
All 19" mounting brackets are reversible and can mount in EIA and
WECO racks.
4
40 mm recess FMTs are equipped with a special trumpet sliding
radius limiter. Other mounting styles cannot be used in 40 mm
recess applications.
Termination/Splice Fixed Bulkhead
(right splice entry)
Termination/Splice Fixed Bulkhead
(right splice entry)
10/03 • 100571
600 mm Products
70
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
1 Rack Unit – Termination and Storage Fixed Bulkhead
Catalog Number
FMT-D __ __ 0 __ 0 __ 0 __ - __ __ __ __
Configuration
SG Termination/storage with bulkhead
plate (right storage entry)
SF Termination/storage with bulkhead
plate (left storage entry)
Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2
Mounting Style
1

A 19"/5" recess
C 19"/2.2" recess
E 19"/40 mm recess
2
F ETSI/40 mm recess
2
Faceplate Color
P Putty
Connector/Adapter Style
Multimode
9SC
YLX.5
®
6LC
Singlemode
7 SC ultra polish
J SC angled polish
K E-2000 angled polish
8LC
XLX.5
®
Adapters Loaded
A Adapters only
0 No adapters
Number of Ports with Adapters
01 24
1
All 19" mounting brackets are reversible and can
mount in EIA and WECO racks.
2

40 mm recess FMTs are equipped with a special
trumpet sliding radius limiter. Other mounting styles
cannot be used in 40 mm recess applications.
Termination/Storage Fixed Bulkhead
(right storage)
Termination/Storage Fixed Bulkhead
(right storage)
This configuration features fixed bulkhead style adapter plates and accommodates singlemode SC (ultra
polish and angled), E-2000, LC and LX.5
®
, as well as multimode SC, LC, and LX.5 adapters. When ordered
with 24 LC or LX.5
®
adapters, this FMT supports 48 fibers.
10/03 • 100571
600 mm Products
71
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
1 Rack Unit – Accessories
Sliding Adapter Packs
Description
Multimode
ST
®
SC
Singlemode
FC hybrid (FC connector on front;
SC connector on back of bulkhead)
FC ultra polish

ST
®
hybrid (ST
®
connector on front;
SC connector on back of bulkhead)
ST
®
ultra polish
SC ultra polish
FC angled polish
SC angled polish
E-2000 angled polish
FC with zirconia adapter
SC with zirconia adapter
ST
®
with zirconia adapter
Catalog Number
FMT-2SAP05
FMT-2SAP09
FMT-2SAP01
FMT-2SAP02
FMT-2SAP03
FMT-2SAP04
FMT-2SAP07
FMT-2SAP0F
FMT-2SAP0J
FMT-2SAP0K
FMT-2SAP0L

FMT-2SAP0N
FMT-2SAP0P
Ordering Information
FMT-ACCCLMP01
0.25" Offset
from Rack
FMT-ACCCLMP02
1.25" Offset
from Rack
Rack
Cable
Cable
Cable Clamp Kit
1.0"
(2.54 cm)
19.5"
(49.53 cm)
Wall
FMT Panel Shown
for Reference,
Not Included in Kit
Vertical Cable Guide
Accessories
Catalog Number
FMT-ACCWLMT01
FMT-ACCCLMP01
FMT-ACCCLMP02
FMT-ACC01B
FMT-ACC01P
Description

Wall mount kit
Cable clamp kits
.25" offset from frame
1.25" offset from frame
Vertical cable guides
Black
Putty
Ordering Information
10/03 • 100571
600 mm Products
72
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
1 Rack Unit – Specifications
PHYSICAL
Approximate Weight: 8 to 10 lbs (3.7 to 4.5 kg)
Configuration Options and Capacity: Termination only (24 or 32 fibers)
Termination/storage (12, 16, or 24 terminations)
Bulk Storage
3 mm outer diameter cable: 32 cables, length 2.5 m each
2 mm outer diameter cable: 48 cables, length 2.5 m each
1.7 mm outer diameter cable: 60 cables, length 4 m each
Discrete storage
3 mm outer diameter cable: 16 cables, length 1.7 m each
2 mm outer diameter cable: 16 cables, length 2 m each
1.7 mm outer diameter cable: 16 cables, length 2.5 m each
Termination/splicing (12, 16, or 24 splices)
1.7"
(4.32 cm)
11.01"

(27.97 cm)
17.26"
(43.84 cm)
Front View
Shown without Sliding Radius Limiters
A
B
C
Ordering
Code Configuration A B C
C 19" EIA (2.2" recess) 18.32" (46.5 cm) 1.25" (3.2 cm) 2.25" (5.7 cm)
E 19" EIA (40 mm recess) 18.32" (46.5 cm) 1.25" (3.2 cm) 1.54" (3.9 cm)
A 19" EIA (5" recess) 18.32" (46.5 cm) 1.25" (3.2 cm) 5.0" (12.7 cm)
F ETSI (40 mm recess) 20.28" (51.5 cm) 0.98" (2.5 cm) 1.54" (3.9 cm)
Universal Mounting Bracket,
EIA or WECO rack mount
10/03 • 100571
600 mm Products
73
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
2 Rack Unit – Termination with Adapters Only
72-Termination with Adapters Only
Sliding Adapter Pack
Shown in Access Position
Catalog Number
FMT-GRT0 __ 0 __ 0 __ - A72 __
Connector/Adapter Style
Lock Type
0 No lock

1 Lock, key type 1
2 Lock, key type 2
Faceplate Color
P Putty
Adapters Loaded
A Adapters loaded
0 No adapters
Multimode
9SC
YLX.5
®
6LC
Singlemode
2 FC ultra polish
7 SC ultra polish
F FC angled polish
J SC angled polish
L FC with zirconia adapter
N SC with zirconia adapter
8 LC ultra polish
XLX.5
®
angled polish
The termination-only fiber management tray provides termination for 72 fibers in an all-front-access
design. This tray mounts in 19-inch, or ETSI racks. Sliding radius limiters provide cable management for
incoming and outgoing fibers.
10/03 • 100571
600 mm Products
74
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42

Fiber Management Tray
2 Rack Unit – Termination with IFC or Multifiber Cable
The termination-only fiber management tray provides termination for 72 fibers and can be ordered
preterminated with IFC or multifiber cable. This tray mounts in 19-inch, or ETSI racks. Sliding radius
limiters provide cable management for incoming and outgoing fibers.
Catalog Number
FMT-GN7 __ __ __ __ __ __ - A 7 2 __
Cable Type
Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2
Faceplate Color
P Putty
Length (in meters)
Multimode
C IFC stranded (62.5/125)
Y IFC stranded (50/125)
Singlemode
A IFC stranded
M IFC ribbon
H Indoor/outdoor
Connector/Adapter Style
Multimode
9SC
YLX.5
®
6LC
Singlemode
2 FC ultra polish

7 SC ultra polish
F FC angled polish
J SC angled polish
L FC with zirconia adapter
N SC with zirconia adapter
8 LC ultra polish
XLX.5
®
angled polish
72-Termination with IFC or Multifiber Cable
10/03 • 100571
600 mm Products
75
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
2 Rack Unit – Termination and Splice
48-Termination/Splice
Catalog Number
FMT-GTL 0 __ 0 __ __ __ - A48 __
Lock Type
0 No lock
1 Lock, key type 1
2 Lock, key type 2
Cable or Adapter Type
A Adapters only
0 No adapters
C Multimode pigtails (50/125)
K Multimode pigtails (62.5/125)
U Singlemode Maxi-Strip pigtails
Chip Style (mini splice tray)

0 None
2 Heat shrink
3 Mechanical
Faceplate Color
P Putty
Connector/Adapter Style
Multimode
9SC
YLX.5
®
6LC
Singlemode
2 FC ultra polish
7 SC ultra polish
F FC angled polish
J SC angled polish
L FC with zirconia adapter
N SC with zirconia adapter
8 LC ultra polish
XLX.5
®
angled polish
The termination and splice tray terminates
and splices 48 fibers in an all-front-access
design. This tray mounts in 19-inch, or ETSI
racks. Sliding radius limiters provide cable
management for incoming and outgoing
fibers. Panels loaded with pigtails come with
color-coded 900 micron pigtails.
10/03 • 100571

600 mm Products
76
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
2 Rack Unit – Accessories
Sliding Adapter Packs
Description
Multimode
SC
LC
LX.5
®
Singlemode
FC ultra polish
SC ultra polish
FC angled polish
SC angled polish
FC with zirconia adapter
SC with zirconia adapter
LC ultra polish
LX.5
®
angled polish
Catalog Number
FMT-6SAP09
FMT-6SAP06
FMT-6SAP0Y
FMT-6SAP02
FMT-6SAP07
FMT-6SAP0F

FMT-6SAP0J
FMT-6SAP0L
FMT-6SAP0N
FMT-6SAP08
FMT-6SAP0X
Ordering Information
FMT-ACCCLMP01
0.25" Offset
from Rack
FMT-ACCCLMP02
1.25" Offset
from Rack
Rac
Cable
Cable
Cable Clamp Kit
Vertical Cable Guide
Accessories
Catalog Number
FMT-ACCCLMP01
FMT-ACCCLMP02
FMT-ACC21B
FMT-ACC21P
Description
Cable clamp kits
.25" offset from frame
1.25" offset from frame
Vertical cable guides
Black
Putty

Ordering Information
10/03 • 100571
600 mm Products
77
www.adc.com • +32-2-712-65-00 • +32-2-712-65-42
Fiber Management Tray
2 Rack Unit – Micro Value-Added Module System
The 2RU FMT Value-Added Module (VAM) chassis houses up to twelve MicroVAMs. These
MicroVAMs are used for testing and monitoring optical signals; technicians can access both
directions of the signal without disrupting service.
Ordering Information for Micro Value-Added Modules follows on the next page.
Catalog Number
FMT-GVM00000-A72P
Description
2 RU Fiber Management Tray (FMT-G Series)
accommodates up to 12 MicroVAMs
for monitoring optical signals
Ordering Information
FMT-G Series with MicroVAM
MicroVAM Shown
in Access Position

×