BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
!"#$%#"%$&
$'(
)#$*+
, /0123
, 45.3.62/478/9:
!"#$%&'()!)!
, ;8<=84
&*+,-'./')- !01 2"!3!,45067
5"'..89:56;<+)"1=6.>7:=
0?67@"#(A5!2B,'C'7B"=0:
!*D+"E%755F%"0EB"G(AH
0?,I"0+'! !01 2J3"I)B;
"GJ8'5+K*LM,)N.="I5%5K.7
.O(=!8) 2K"0EK1*
P*Q2"E%"0EAC 0:,5%")KR#
-.S%K*S%K.T-UQVS !01
2"!3!7,'8J-"0E"))8+(J!WX)!Y)!%K
Z*
[*\%75"0E.89:)<+0?,4507"I, +
0?#I(>++!7,8)(]^ 0:'67
_>,!J)B+ 0?6`T*
, >6<.?@/478/9:a
#I21% 15]"J(J!T !"I01
%*#I%:0).T)(T,4%3)','7
R,'!37R,4%<+T"1=6.>!"#)Y6
!M.)(T,4% 26*bc%]"75
N#B)(T,4%7,450#,0:d ')!
0:d"01J#)!0:d()5)"G01%
!,!+*
, A.BC238D6<1//478/9:a
&*L2<+"1=2%','76*Y#IJ
(e51"AC<+"1=@< 0]"')"1=15]*LK.9!
-79!;(% !K"G7"M(_/"'(T
%12 '.*S2I1'<+"1=2C+!7
K J.017,!)+%7))1'"#72C
"T.7)#%0,4%
P*S2IG 2%
2I)"M"I<+ 2aY<"72C"07
"G,6`T1 26*S2IGG
<+ 2*S2I)"1=++6)2C,/E"
0;7X7Xfg7K8+B+)"1="#*
EF$GaLQh&&i&jklmnibb&Trang 1
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
[*S2IJ),' _ 2aS 15]2IGo
<+ 27H2IM"C7M(e7M>)';3!
"M(*nH"0E./!)J)"##(JF-+
j*S2IGK,'; 2aS2I),';H<+ 2
,7)7.p*nH51"H=.H<+,';*nH"0E+
R<+@(T% !,';751"J -*Y)';3!#(JF
-+
$*S2I,4%AC
>(>"0E)J),4%) !7(+!J)M
(e7-)7',''70:d7"M(.)
:*
S2I).%,'!37.%'"T7,I"T7,I +"Gq
cE:'"T"M +*Y_/"'(')A"T7)C"G)
A"TH*C5r57"+og1
;s.B+)E*
S2I)CAC8J.H,I +;.0E 2K8J./
;.0E 272C"));.0E 27+ R<+t7X
!"J(J!;.0E 2*
*S2IB()+! 0?aB()+!"0E
) 0?(+!K`+!7o.0:M% 17K
u 0?:) 0?E"M('#*YK+3.+!"T,
%)#7.BM-*Y1'AC+!!
0?*
, +HI8HIJK/LCM/478/9:
&*YKv"E7v5J'()!)!!39!)T<+
"G*X)!)! p!2 '++7!2q2I
8+5)%*
P*UI()!)!"0E!_75"T7 !?+%7v5J#
&8I%,/B%6wGBe*S !()!)!#
I5r(JF!!!+F#>+5+!- !MJ
B"G-+*X)!)!,!JP$xj +7v()!)!J#%
6w<+"1=%J#B,/<+,450 )y;6)%B,/
<+18+1%<+)!0:d*
[*+,T()!)!7)!;5F696w7'()!)!!,"<"G,
GTJ5r+.3!M(A5 0:,(J!*
Y+,')aLv5 0:,"%J#&(J+,')
T!\!+bUVlSQ#d5z9!8"=<+ 0?7=
)) 0: 0?7Y18+"'% 0:).%G)
3"'8"=<+ 0?718+78"=+!.+!"T
<+ 0?<+).%0:*
S 0],!+
E,NO2+P24
EF$GaLQh&&i&jklmnibb&Trang 2
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
$'Q
+**RS#$
* * * * * *
Kính gửi: - Ban giám hiệu Trường Đại Học L01S'Q.
- Khoa xây dựng Trường Đại Học L01S'Q.
- Phòng đào tạo Trường Đại Học L01S'Q.
- Công ty TNHH TM – DV Xuân Long.
- Em tên là: PHAN VĂN HỘI.
- Sinh viên lớp: 08DXD01.
- Ngành: Xây dựng dân dụng và công nghiệp.
- Đơn vò thực tập: Công ty TNHH TM – DV Xuân Long.
- Thực hiện quyết đònh số:…… ngày ………………(V/v Phân công sinh viên đi thực tập tốt
nghiệp) và đề cương thực tập tốt nghiệp của Trường Đại Học L01S'Q.
Em được phân công đến thực tập tốt nghiệp tại Công ty TNHH TM – DV Xuân
Long. Thời gian thực tập: từ ngày 20/03/2011 đến ngày 27/04/2011.
I. NHỮNG THUẬN LI VÀ KHÓ KHĂN
1. Thuận lợi
- Ban giám hiệu, phòng Đào tạo, khoa xây dựng đã hướng dẫn chi tiết đề cương thực
tập giúp em hiểu và thực tập bám sát với đề cương đã giao.
- Được sự phân công công việc hợp lý và bố trí cán bộ kỷ thuật trực tiếp hướng dẫn
của Anh: Trần văn Khả - Chức vụ: Phó phòng kỹ thuật Công ty TNHH TM – DV
Xuân Long.
- Được sự hướng dẫn cụ thể của Thầy:…………………………………………………………………
- Được sự giúp đỡ và chỉ bảo tận tình của các Anh (chò) cán bộ kỷ thuật Công ty
TNHH TM – DV Xuân Long.
- Công ty TNHH TM – DV Xuân Long đã tạo điều kiện và giúp đỡ về mọi mặt
trong suốt thời gian thực tập. Để em hoàn thành tốt nhiệm vụ được giao và bám sát
với đề cương thực tập.
- Được sự giúp đở nhiệt tình của các Cán bộ chỉ huy công trình (Cao ốc văn phòng)
do Công ty Cổ phần kiến trúc xây dựng KX là đơn thi công xây lắp.
- Công trường đang thi công phần thô nên em tiếp thu được các quy trình kỷ thuật và
công nghệ thi công phần thân.
- Em đã lên thời gian biểu thực tập hợp lý giúp cho em vừa thực tập được chức năng
của một cán bộ kỹ thuật xây dựng trên công trường; nghiên cứu hồ sơ, bản vẽ công
trình; ôn thi bài vỡ chuẩn bò cho đợt tốt nghiệp sắp tới.
2. Khó khăn:
- Thời gian thực tập ngắn nên không thể theo giỏi thi công hết tất cả các bộ phận,
công đoạn của công trình. Những kiến thức đã học được ở trường chỉ là cơ bản,
không khái quát hết tất cả những vấn đề bắt gặp trong thực tế. Vì vậy trong quá
EF$GaLQh&&i&jklmnibb&Trang 3
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
trình thực tập em đã gặp không ít những khó khăn bỡ ngỡ. Tuy nhiên đây cũng
chính là thách thức, là thành công của em trong thời gian thực tập cũng như công
việc sau này.
Qua thời gian học tập tại Trường và trong suốt thời gian đi thực tập tốt nghiệp vừa
qua. Em học hỏi rất nhiều điều bổ ích để có được kiến thức cho bản thân và Em xin
trình bày với Ban giám hiệu, Phòng đào tạo và Khoa xây dựng Trường Đại Học
Lương Thế Vinh cùng với Công ty TNHH TM – DV Xuân Long như sau
II. GIỚI THIỆU VỀ ĐƠN VỊ THỰC TẬP VÀ CÔNG TRÌNH THỰC TẬP
A. GIỚI THIỆU VỀ ĐƠN VỊ THỰC TẬP
1. Giới thiệu chung
- Tên đơn vò thực tập: CÔNG TY TNHH TM – DV XUÂN LONG
- Đòa chỉ: 742 Lũy Bán Bích,Phường Tân Thành,Quận Tân Phú.TP,Hồ Chí Minh
- Điện thoại: 08.62937093
2. Cơ cấu tổ chức bộ máy hoạt động:
STT HỌ VÀ TÊN CHỨC VỤ
01
Phạm Thò MinhThấu Giám đốc
02
Lưu Thò Kim Hồng Trưởng phòng Kỹ thuật
03
Trần văn Khả Phó phòng Kỹ thuật
04
Phạm Thò Ngọc Kế toán trưởng
05
Nguyễn Thò Kim
Tuyền
Thủ quỹ
Và tập thể cán bộ kỷ thuật, công nhân viên trong công ty Xuân Long
- Sơ đồ tổ chức bộ máy hoạt động:
B. GIỚI THIỆU VỀ CÔNG TRÌNH THỰC TẬP.
EF$GaLQh&&i&jklmnibb&Trang 4
Giám đốc
TP.Kỹ thuật
TP.Thi công
Kế toán
trưởng
Kế toán viênKế toán viên
Cán bộ kỷ thuật phụ
trách xây dựng
Nhân viên phục vụ
Nhân viên phụ trách
Kinh tế
Nhân viên phục vụ
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
1. Khái quát công trình
Trung Tâm Thương Mại Dòch Vụ Điện – Điện Tử Biên Hòa với qui mô không
lớn lắm (7 tầng lầu, 1 tầng trệt và 1 tầng hầm) nhưng được thiết kế xây dựng với
tiện nghi đầy đủ, không gian kiến trúc phù hợp, đảm bảo mỹ thuật và có đầy đủ kỹ
thuật hạ tầng. Trung Tâm Thương Mại Dòch Vụ Điện – Điện Tử Biên Hòa cùng với
các công trình xây dựng khác làm tăng vẻ mỹ quan và nâng cấp đô thò thành phố Hồ
Chí Minh.
Công trình Trung Tâm Thương Mại Dòch Vụ Điện – Điện Tử Biên Hòa là một
cao ốc văn phòng khá hiện đại với diện tích gần 3000 m
2
sàn, xây dựng trên khu đất
có diện tích 34.7 x 20 m = 694 m
2
. Để tận dụng hết không gian khá hẹp, do đó công
trình được thiết kế gần như là một thể thống nhất 1 tầng hầm + 1 tầng trệt + 7 tầng
lầu và sân thượng.
Công trình làm bằng vật liệu chính là BTCT phù hợp với khả năng cung cấp vật
liệu và trình độ thi công hiện nay của các công ty xây dựng việt nam, cũng như đáp
ứng được niên hạng sử dụng từ 100 năm trở lên.
Được sự phân công công việc của Anh: Nguyễn Quốc Tuấn, chức vụ:Phó phòng kỹ
thuật. Em được bố trí đến công trình đang xây dựng là: Trung Tâm Thương Mại Dòch
Vụ Điện – Điện Tử Biên Hòa – 05 Phan Xích Long- P2, Q. Phú Nhuận. Với vai trò
là một cán bộ giám sát kỷ thuật bên A, được sự đồng ý và giúp đở của Ban chỉ huy
công trường xây dựng đang nhận thầu thi công. Em đã tiếp cận và bám sát với đề
cương của nhà Trường để thực hiện tốt chức năng, vai trò và nhiệm vụ của người
cán bộ kỷ thuật trong việc tổ chức quản lý, chỉ đạo thi công xây dựng một công trình
dưới sự hướng dẫn của cán bộ kỷ thuật trên công trường.
1. Tên công trình: Trung Tâm Thương Mại Dòch Vụ Điện - Điện Tử Biên Hòa.
2. Đòa điểm xây dựng: 5. Phan Xích Long. P2. Q. Phú Nhuận. Tp Hồ Chí Minh.
3. Mục đích sử dụng: Cao Kvăn phòng .
4. Đơn vò thiết kế: Công ty TNHH Tư Vấn TK - XD - TM Đại Kiến Việt.
5. Đơn vò thẩm tra: Công ty CP Tư Vấn Xây Dựng Tổng Hợp NAGECCO.
6. Đơn vò Tư vấn giám sát: Công ty TNHH Hoàng Khải Quân
6. Đơn vò thi công: Công ty cổ phần kiến trúc xây dựng KX.
7. Vốn đầu tư: Nguồn vốn của công ty.
8. Đơn vò quản lý xây dựng: Công ty TNHH TM-DV Xuân Long.
9. Vò trí đòa lý:
+ Phía bắc giáp với Khu đất trống.
+ Phía nam giáp với Khu đất trống.
+ Phía đông giáp đường Phan Xích Long.
+ Phía tây giáp với nhà dân.
III. ĐẶC ĐIỂM CỦA CÔNG TRÌNH THỰC TẬP:
QUY MÔ
- Công trình có một khối.
+ Diện tích khu đất xây dựng : 694 m
2
+ Kích thước mặt bằng nhà : 12x30 m
+ Số tầng nhà : 1 tầng hầm + 1 tầng trệt + 7 tầng lầu + sân thượng
+ Chiều cao nhà :(so với mặt đất ) : 33 m
EF$GaLQh&&i&jklmnibb&Trang 5
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
+ Diện tích xây dựng : 360 m
2
+ Diện tích sử dụng : 360 m
2
1. Đặc điểm kiến trúc:
* Tầng hầm:
- Diện tích: 360m
2
- Chiều cao tầng hầm: 3.0m
- Tầng hầm gồm: phòng máy phát điện, garage, kho, cầu thang, gin kỹ
thuật, ram dốc, và máy bơm.
GARAGE
i = 10%
ĐẶT MÁY
PHÁT ĐIỆN
DỰ PHÒNG
ĐẶT MÁY
BƠM
KHU VỰC ĐỂ XE 2 BÁNH
(DÀNH RIÊNG CHO NHÂN VIÊN)
KHO
HỒ NƯỚC NGẦM
THOÁT RA NGOÀI
3000 6000 6000 4500
19500
2000 6000 6000 6000 6000 6000 2700
30000
600
1200 1200
600
1200
600
600
600
600
1200
600
1200
600
1200
600
600
600
1200 1200
600
1200
600
1200
600
1200
600
1200
600
CỬA CUỐN
6 5 4 3 2 1
S
1 1
S
1
S
1
S
1
S
1
S
1
S
1
S
1
S
1
S
1
S
1
S
2000 2000 2000 2400
1200
6001200
600
12000
B
B
C
C
A
3
Đ
4
Đ
1 2
3 4
5
6
A
C
D
THOÁT RA NGOÀI
A
TƯỜNG RÀO
-3.000
MẶT BẰNG TẦNG HẦM. TL: 1/100
* Tầng trệt,lầu1;
- Diện tích: 360m
2
- Chiều cao: 3.3m
- Không gian tầng trệt gồm: sảnh, quản lý, văn phòng, phòng trưng bày
sản phẩm
32000
6000
4500
2000
6000
19500
60003000
A
C
D
60006000
THOÁT RA NGOÀI
6000
6 5 4
6000
3 2
Đ
3
20002000 2000
2700
1
TƯỜNG RÀO
PHÒNG
ĐẶT
MÁY
ĐIÊU
HÒA
PHÒNG TRƯNG BÀY SẢN PHẨM
PHÒNG TRƯNG BÀY SẢN PHẨM
VÁCH KÍNH
VÁCH KÍNH
3000 3000
500
600
30003000
HỒ
CÁ
CẢNH
2
Đ
1
Đ
TIỀN
SẢNH
TIẾP
TÂN
1000
1000
1000
ĐI THANG MÁY
4500
4
Đ
4
Đ
5
Đ
5
Đ
5
Đ
5
Đ
5
Đ
4
Đ
500
600500
500
600500 500
500
600
Đ
4
Đ
4
S
2
A
D
B
C
3000 3000
15001500
0.000
MẶT BẰNG TẦNG TRỆT. TL: 1/100
600
500
6000
3000
* Lầu 2;
- Diện tích: 360m
2-
- Chiều cao: 3.3m.
- Không gian tầng: phòng hành chính.
EF$GaLQh&&i&jklmnibb&Trang 6
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
2000 2000 2000
12003000650900
1000 1000 1000
6000 6000 6000 6000 6000
2000 1000 2000 1000 3000 3000
700 600 500 600 600 600 600 500 600 700
1500 1500 1500 1500
30000
12000
5 4 3 2 1
HỘP ĐIỆN
DÙNG VÁCH KÍNH 10 LY
HÀNH LANG DẪN ĐẾN CÁC PHÒNG HÀNH CHÍNH
PHÒNG HỌP &
BAN CÔNG
KHUNG NHÔM
HỘI NGHỊ
3000 3000
6000
12000
A
C
D
A
B
C
D
W.C NAMW.C NỮ
1300900
3000
800
TỦ CỨU HỎA
TỦ ĐIỆN
700700 700
BỂ NƯỚC
800 1400 1700 1400 800
MẶT BẰNG LẦU 2 TL : 1/100
6
* Lầu : 3;4;5;6;7
- Diện tích mỗi lầu: 360 m
2-
- Chiều cao: 3.4m mỗi lầu.
- Không gian lầu: văn kỹ thuật.
*
Tầng
thượng:
- Diện tích: 360m
2
- Chiều cao: 3.3m
- Không gian tầng: Các hệ thống kỹ thuật thang máy.
EF$GaLQh&&i&jklmnibb&Trang 7
HÀNH LANG DẪN ĐẾN CÁC PHÒNG KỸ THUẬT
30000
6000
4
MẶT BẰNG LẦU 3, 4, 5, 6, 7 TL : 1/100
2000
12000
2000
A
1000
60006000
6 5
30003000
C
1000
D
KHUNG NHÔM
DÙNG VÁCH KÍNH 10 LY
12000
TỦ ĐIỆN
60006000
3
1200
2
600
1500
700 500
1500
600600600600500
1500
700600
1500
1
3000
A
B
3000
HỘP ĐIỆN
650900
10001000 1000
2000
1200
20002000
PHÒNG LÃNH ĐẠO
PHÒNG KẾ HOẠCH
C
D
3000 6000
3000
900
TỦ CỨU HỎA
1300
1400800
W.C NỮ
800
W.C NAM
1700 1400
700700 700
BỂ NƯỚC
800
2000 1000 20001000
PHÒNG LÀM VIỆC
LÃNH ĐẠO
ỐNG THOÁT NƯỚC MƯA
BỒN HOA
VÒI TƯỚI HOA
CHẬU RỬA LY TÁCH
ỐNG THOÁT NƯỚC MƯA
VÀ PHỤC VỤ NƯỚC
QUANG MÀU XANH
VÁCH KÍNH PHẢN
CAO 900 TỪ SÀN
NGĂN CHỨA ĐỒ
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
HỘP KỸ
D
-3000
0.00
+3300
+6600
+9900
Hành lang dẫn đến
các phòng
Vách kính khung nhôm
BUỒNG THANG MÁY
3300
1700
900
3300
LẦU 7
500
1700
3300
1400900
33003300
14009001000 1000
1700
3300
LẦU 4
500500
LẦU 5
500500600
900
3300
1000 10001400
1700
3300
LẦU 6
600 500 500 600 500
3000
15009001900
4200
TẦNG THƯNG
10001400 1000
2400
1400
500600 500
1700
600
2400
DÙNG CHO BAR
HỒ NƯỚC
KHO CHỨA ĐỒ
+16500
+13200
+19800
+23100
+26400
+30600
+33000
1700
600
3300
1400
3300
12000
6000
MẶT CẮT B - B. TL:1/100
6000
A
C
6000
12000
MẶT CẮT C - C. TL:1/100
1500
3000
1500
3000
A
6000
D
1500
1500
C
LAM THÔNG GIÓ
CHO TẦNG HẦM
600 500
1000
3300
1400
3300
TẦNG TRỆT
1000
3300
2300 900
500
3300
1700
600
LẦU 1
1700
500
1400
3300
900 9001000
600
3300
LẦU 2
1700
500
LẦU 3
500500
THUẬT
2. Đ ặ c đi ểm kết cấu:
- Công trình thuộc dạng khung bêtông cốt thép tòan khối.
- Móng cọc bêtông cốt thép Móng cọc bê tông cốt thép khoan nhồi đường kính
400mm, chiều dài cọc 18m, sức chòu tải thiết kế: 73tấn/cọc.
- Khung, sàn bằng bêtông cốt thép mác 250.
- Tường bao che bằng gạch ống dày 20 cm. Tường ngăn bằng gạch ống dày 10
cm, và kính 10 mm.
EF$GaLQh&&i&jklmnibb&Trang 8
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
- Cửa bằng nhôm – kính.
- 02 cầu thang máy và 02 cầu thang đi bộ .
- Mổi tầng đều có khu vệ sinh riêng.
- Mái lợp bằng tol lạnh.
- Nước được chứa trong bồn 1000 l
3. Cơ sở phục vụ thi công:
∗
Nguồn cung cấp vật tư xây dựng
- Nguồn cung cấp điện cho công trình: Điện tại TPHCM.
- Nguồn cung cấp nước cho công trình : Hệ thống nước TPHCM.
- Giao thông tới công trình: Nằm trên trục đường chính,đường Phan Đăng Lưu,
Q.Phú Nhuận
- Nguồn cung ứng lao động cho công trình: Tại TP.HCM.
4. Hình thức giao khoán
- Hợp đồng A – B, với hình thức khoán gọn.
- Phương thức thanh toán, thanh toán theo tiến độ công trình.
- Thời gian thực hiện 12 tháng, từ ngày 05/01/2011 đến 05/01/ 2012
IV. CƠ CẤU TỔ CHỨC HOẠT ĐỘNG TẠI CÔNG TRƯỜNG XÂY DỰNG
1. Sơ đồ tổ chức hoạt động tại công trường xây dưng
Tổ đổ đất
kiêm đổ
bêtông
Tổ gia
công sắt
thép
Tổ
mộc
Tổ nền
xây trát
Tổ vận
hành
MXD
Tổ
điện
nước
2. Nhiệm vụ cán bộ kỹ thuật
a) Trách nhiệm khi giám sát:
- Theo dõi giám sát mọi diễn biến thi công tại công trường do bên B thực hiện.
- Cùng với bên nghiệm thu cơ sở xác nhận khối lượng các phần công việc đã hoàn
thành.
EF$GaLQh&&i&jklmnibb&Trang 9
CÔNG TRƯỜNG XÂY DỰNG
Trung Tâm Thương Mại
Ban Giám đốc Đơn vò thi công
(Cty C.P XD Kiến Trúc KX)
Chỉ huy trưởng
công trường
Kỷ thuật
công trường
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
- Có trách nhiệm chỉ thò cho bên B đáp ứng và thực hiện các nhiệm vụ cần thiết
cho việc thực hiện đúng hợp đồng.
b) Quyền hạn cán bộ kỹ thuật khi khám sát
Từ chối không nghiệm thu những khối lượng không đảm bảo chất lượng.
c) Nhiệm vụ của cán bộ kỹ thuật khi thi công công trình
- Để tiến hành thi công một công trình với trách nhiệm là người trực tiếp chỉ đạo
thi công trước hết ta phải nghiên cứu kỹ hồ sơ thiết kế công trình chuẩn bò thi
công, nghiên cứu mặt bằng thi công tại khu vực xây dựng từ đó có biện pháp bố
trí mặt bằng thi công cho phù hợp với thực tế tránh không gây trở ngại trong quá
trình thi công. Các công việc cần thiết cho việc chuẩn bò thi công như: Kho, bãi
tập kết vật liệu, láng trại tạm, các xưởng gia công mộc, sắt, đường tạm trong
công trình, điện nước sinh hoạt, phục vụ sản xuất, máy móc thiết bò phục vụ thi
công…
- Lập biện pháp thi công cho các công việc chính trong công trình như công tác
cọc, công tác bêtông cốt thép móng, cột dầm, sàn, công tác xây và hoàn thiện.
- Căn cứ vào kế hoạch tiến độ thi công công trình đơn vò. Lập kế hoạch tiến độ thi
công ngắn ngày, hàng tháng, hàng tuần.
- Dựa vào tiến độ lập biểu nhu cầu cung cấp vật tư, trang thiết bò phục vụ thi công.
- Các công việc hằøng ngày phải ghi vào sổ nhật ký công trình.
- Báo cáo nghiệm thu từng phần công việc đã hoàn thành trước khi khối lượng
công việc tiếp theo. Biên bản nghiệm thu phải được đại diện hội đồng nghiệm
thu ký tên, đóng dấu.
- Nếu trong quá trình thi công phát hiện có những sai sót lớùn trong thiết kế cũng
như trong quá trình thi công gặp những trường hợp phát sinh thì phải gọi giám sát
hoặc người bên chủ đầu tư có thẩm quyền đến lập biên bản tìm cách giải quyết.
- Phải kiểm tra tình trạng máy móc thiết bò, phương tiện phục vụ thi công trước khi
vận hành. Cấm không cho những người không có trách nhiệm, chưa được học tập
quy trình kỹ thuật vận hành chưa được giao nhiệm vụ thi công thì không được tuỳ
tiện vận hành sữa chữa máy móc thiết bò thi công.
- Khi gián đoạn thi công nhiều ngày liền thì phải nhắc nhở công nhân kiểm tra lại
các điều kiện an toàn, kiểm tra lại giàn giáo trước khi thi công tiếp.
- Khi giám sát thi công tại công trình người cán bộ kỹ thuật cần phải có cách nhìn
tổng quát toàn công trình mình giám sát thi công.
- Những vấn đề nêu trên mang tính chất chung của một người kỹ thuật khi thi công
trên công trường.
3.Nhiệm vụ được giao:
Trong thời gian thực tập tại công trình, ngày 20/3/2011 công trình đang thi công phần
thô cốt pha lầu 2 đến ngày kết thúc thực tập là đã hoàn thành đang đổ cột lầu 3.
Em được hướng dẫn theo dõi qúa trình thi công một số công việc sau:
• Công tác ván khuôn, cốt thép, bêtông dầm sàn, cầu thang lầu 2.
• Công tác ván khuôn, cốt thép lầu 3.
V. MỘT SỐ TÀI LIỆU THAM KHẢO CÔNG NGHỆ MỚI
EF$GaLQh&&i&jklmnibb&Trang
10
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
(,T23234U/4.8T23VW2XY/T238-//4Z:+CXX[\"\8J,
BubbleDeck là một công nghệ thi công sàn bê
tông cốt thép mang tính cách mạng trong xây
dựng khi sử dụng những quả bóng bằng nhựa tái
chế để thay thế phần bê tông không tham gia
chịu lực ở thớ giữa của bản sàn, làm giảm đáng
kể trọng lượng bản thân kết cấu và tăng khả
năng vượt nhịp lên khoảng 50%. Bản sàn
BubbleDeck phẳng, không dầm, liên kết trực tiếp
với hệ cột, vách chịu lực có nhiều ưu điểm về mặt
kỹ thuật và kinh tế:
• Tạo tính linh hoạt cao trong thiết kế, có
khả năng áp dụng cho nhiều loại mặt bằng công trình.
• Giảm tới 35% trọng lượng bản thân kết cấu, từ đó giảm kích thước hệ kết cấu cột,
vách, móng.
• Tăng khoảng cách lưới cột, giảm hệ tường, vách chịu lực.
• Giảm thời gian thi công và các chi phí dịch vụ kèm theo.
• Tiết kiệm khối lượng bê tông thi công: 2.3kg nhựa tái chế thay thế cho 230kg bê
tông/m³ (BD 280).
• Rất thân thiện với môi trường khi giảm lượng phát thải năng lượng và khí
Cacbonic C02 (khí nhà kính)
* Cấu tạo:
Sàn Bubbledeck là loại kết cấu sàn rỗng làm việc theo hai phương trong đó các quả bóng
nhựa có vai trò giảm thiểu lượng bê tông ở vùng không cần thiết đối với kết cấu.
Bằng cách phối hợp lỗ rỗng tạo ra do trái bóng và bố trí các thanh của lưới thép, kết cấu
bê tông có thể được tối ưu hoá và tối đa hóa việc sử dụng đồng thời các vùng chịu
moment uốn và vùng chịu lực cắt.
Ưu điểm trong lắp dựng của BubbleDeck chính là kết quả của phố hợp đặc tính hình học
của hai chi tiết cơ bản: lưới gia cường và bóng nhựa rỗng. Khi lưới gia cường trên và
dưới được liên kết theo cách thông thường, một phần tử Bubbledeck ổn định đã được
hình thành.
Lưới thép gia cường có nhiệm vụ phân bổ và cố định các trái bóng tại những vị trí chính
xác, trong khi đó, các trái bóng định hình thể tích lỗ rỗng, giúp giữ vững định dạng của
lưới thép gia cường đồng thời ổn định vị trí của lưới bóng. Khi tiến hành đổ bê tông phủ
kín lưới thép nêu trên, ta có được tấm sàn rỗng "toàn khối" triệt để làm việc theo hai
phương.
* Hiệu quả.
Ưu thế chính của các quả bóng là giảm trọng
lượng của tấm sàn. Tải trọng bản thân của sàn
Bubbledeck giảm 1/3 lần so với tấm sàn đặc có
cùng độ dày và không ảnh hưởng đến khả năng
chịu uốn và độ cứng của tấm sàn.
Giá trị gia tăng sử dụng bê tông :
So với tấm sàn đặc, một tấm sàn Bubbledeck có
khả năng chịu lực gấp đôi với 65% lượng bê tông
và có cùng khả năng chịu lực với 50% lượng bê
tông.
EF$GaLQh&&i&jklmnibb&Trang
11
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
Mặt bằng nhìn từ bên trên, đặt các tấm thép chịu Mô men căng trên, thép chống chọc
thủng
X*SV{Y|V}Y|V~[b
1;[bn+9.
S9!)+ !.•,!+"=+K7) €.T0'"I6
(e[b+9.3! +T(0:"T) = 0?";*•[b
+9."I6+!.T.?JHE*
+7 €7(G
Y[b+9.#M3Q+@"Bo‚*S9!)+G6
70"IA(%<+.3!! 26,Jo=.+!7#
I="0E(`!:5C#[,ƒ7="0E"T";k7$"T„9 *B;[b+9.
:,';[G2(].0:w"+!+7]B+..:_6K@+#)
)7)@+_.J,K.0E5!:0?3+5( GK*
Lvw0?75(e;[b+9.#,K.0Eq,!J…5!:0?3
5(#c,H0:*\qHE!B0+!6
G";'2',H+K#7[b+9.#I+'B36K
J,+)";*
B;[b+9."0E"_5z9!','?++,"R
†J#)! 0? +011:MG*?%7'C!6
+!2>>)<+ 25F €1H;P…5!:,4
%6 GK7"?d(J!"JA-,0:$o*„'(=
(+"J%@0:!:H"0(+"!T),!J&&
‡b*
Y#M3Q+@,).70!"'+C.!3%.0,
"),I*S@o&‚‚5+,+8++6r(e[b+9.3
X2Y)7S<0:QpQo\"`!w%G6[)
5J6;[b+9.3YS17DJ`SnVYL*
EF$GaLQh&&i&jklmnibb&Trang
12
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
XT"` +8'"=G"=C!)6 2(J"1)6
1(J!‡XbSnVYL(+)kƒP"`#H"'"=CC%.
[b+9.7(0:"3!15]"IC T ` !.•6*S
7+70:+d0+#KOG,4%7;.0E)
!B 2.:7+!"M(.) 2#K5)
R0:GM)./*
ˆ‰‡U{ŠLY‹tlŒ•{SŽL••b‘VŒ}SŒ}Lm{}•*
S -.0E’&ƒP“”&ƒj36
+&ƒP”&ƒj36*
\J+!KH&ƒP”&ƒj36*
Y)7)7K)7K;0?*
\+,3?*
<+(35F’1&ƒP”&ƒj36*
YK"0E"T";k7$"T 9
SA-<+ 2 ko
\4%"0?o97"7Kd0:*
ncE!),I+!K707]*
UM(cE!)e]c N7c62.
PHẦN 3
BIỆN PHÁP KỸ THUẬT VÀ TỔ CHỨC THI CÔNG CÔNG TRÌNH
,],
Gói thầu bao gồm các phần việc: xây dựng phần thô và hoàn thiện nhà thuộc dự án:
Văn phòng Kết cấu khối ở chủ yếu như sau :
- Lõi cứng thi công bằng công nghệ côppha thép
- Vách, cột, sàn trong lõi đổ bê tông toàn khối.
- Tại các tầng 5, bê tông dầm biên đổ toàn khối.
- Kết cấu bê tông cốt thép cột, vách được đổ tại chỗ.
Để đảm bảo các yêu cầu chòu lực của cốp pha vách, dầm, giáo chống đỡ dầm, cũng
như quá trình thi công liên tục ta cần tính toán lựa chọn phương án cốp pha giáo chống
và phân chia phân đoạn cho tầng điển hình. Với chiều cao nhà 33m ta cần tính toán
chia đợt thi công cho phù hợp với khả năng làm việc của máy vận thăng.
II. TỔ CHỨC NHÂN SỰ
Sơ đồ tổ chức: việc tổ chức nhân sự được điều động và bố trí hợp lý dựa trên năng lực
và kinh nghiệm của từng người, từng tổ đội.
Cơ cấu tổ chức nhân sự:
1. Chỉ huy trưởng, kỹ thuật công trình.phụ trách chung.
2. Tổ kỹ thuật 1: 03 người phụ trách phần cốp pha, cốt thép, bê tông toàn
khối.
3. Tổ kỹ thuật 2: 01 kỹ sư phụ trách xây và hoàn thiện
4. Ban an toàn lao động và bảo vệ môi trường:
01 cán bộ chuyên trách An toàn lao động.
5. Tổ nghiệp vụ:
EF$GaLQh&&i&jklmnibb&Trang
13
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
01 cán bộ điều độ cung ứng vật tư. 01 cán bộ thủ kho. 01 cán bộ thanh
toán. 01 kế toán. 01 thủ quỹ
6. Tổ phục vụ:
-Bảo vệ: 01 người.
-Tổ điện máy: 01 người.
-Tổ trắc đạc: 02 người.
7. Tổ cốp pha: 01 tổ (mỗi tổ 15 người).
8. Tổ thép: 01 tổ (12 người).
9. Tổ bê tông: 01 tổ (17 người).
10.Tổ xây và hoàn thiện:01 tổ (mỗi tổ 15 người).
III. TỔ CHỨC THI CÔNG
1. Bố trí tổng mặt bằng thi công
Quá trình thi công được phân làm 2 giai đoạn, giai đoạn thứ nhất thi công phần thô
công trình, giai đoạn 2 thi công phần hoàn thiện.
6000
6000
6000 6000 6000
60006000
A
C
D
6 5 4
3
2 1
600030003000
D
A
C
B
MẶT BẰNG PHÂN ĐỌAN THI CÔNG SÀN TL:1/100
MÁY VẬN THĂNG
DÀN GIÁO BẢO VỆ
CẦN TRỤC THÁP
R
=
2
5
m
PHÂN ĐỌAN 1
LƯỚI BẢO VỆ
HƯỚNG DI CHUYỂN CŨA CẦN TRỤC THÁP
EF$GaLQh&&i&jklmnibb&Trang
14
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
12000
TƯỜNG TRÁT XONG
MẶT CẮT THI CÔNG KHUNG TL:1/100
GIẰNG CHO MÁY VẬN THĂNG
GIẰNG MÁY VẬN THĂNG
ĐƯỜNG ỐNG BƠM
BÊ TÔNG
GHÉP CỐP PHA CỘT
ĐỔ BÊ TÔNG CỘT
SÀN CÔNG TÁC
LAN CAN BẢO VỆ
CỘT ĐẢ THÁO CỐP PHA
CỬA ĐỔ BÊ TÔNG
XE BƠM BÊ TÔNG
XE TRỘN BÊ TÔNG
- CẦN TRỤ THÁP HIỆU KB-160-2
- ĐỘ VỚI R = 25 m
- ĐỘ VỚI XA NHẤT 25 m
- ĐỘ VỚI GẦN NHẤT 5.5 m
- SỨC NÂNG NHỎ NHẤT 4.5 T
- SỨC NÂNG LỚN NHẤT 8 T
- VẬN TỐC NÂNG 22.5 m/ph
- VẬN THĂNG LOẠI TP-5(X-953)
- Hmax = 50 m
- Q = 0.5T
- VÂN TỐC V = 7.0 m/s
- TẦM VỚI± 3.5 m
ĐỊNH VỊ ĐẶT KHUNG THÉP
GIẰNG CHO CẦN TRỤC
ĐANG TRÁT TƯỜNG
BÀN CHẤT
A
6000
6000
C
D
2. Tình tự thi công phần thân công trình.
a. CÁC GIẢI PHÁP CHỦ YẾU:
Giải pháp vận chuyển:
Vận chuyển trên mặt bằng công trình, bốc xếp nguyên vật liệu theo phương đứng
phục vụ cho thi công bằng vận thăng
Giải pháp cốp pha, giáo chống
Giải pháp cốp pha:
EF$GaLQh&&i&jklmnibb&Trang
15
Thi công hoàn
thiện thô
Thi công phần
hoàn thiện
Tổng nghiệm thu, bàn giao
Thi công phần điện
chống sét, nước
Thi công phần sân
hè ngoài nhà,
Thi công
phần kết cấu
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
- Cột vách toàn khối: sử dựng cốp pha gia công sẵn thành mảng hoặc tổ hợp
riêng lẻ
- Dầm toàn khối, sàn mái toàn khối sử dụng tổ hợp riêng lẻ cốp pha đònh hình,
giáo chống + phụ kiện.
Giải pháp giáo chống: Chống cốp pha cột, dầm, sàn, bằng giáo thép, kết hợp với
cây chống đơn bằng ống thép φ48, dài từ 1,2 ÷ 4,5m, giáo thép và cây chống đơn
đều có bộ phận vi chỉnh độ dài bằng kích tại cả 2 đầu, tối đa được 50cm theo
nguyên tắc, tại các vách biên dùng thêm thép hộp. Hệ cốp pha được đònh vò vững
chắc, chính xác ổn đònh cả 3 chiều không gian.
Sàn thao tác phục vụ công tác xây trát sử dụng giáo thép với hệ tấm sàn thao tác
bằng thép chuyên dụng, có cầu thang lên xuống đồng bộ kết hợp với giáo sàn
thao tác.
b. Giải pháp phối hợp khi thi công phần thô:
Phần thô thân công trình gồm 2 công việc chủ yếu là: Thi công kết cấu BTCT,
cột dầm sàn và xây bao che, ngăn cách từ mặt móng đến mái. Có nhiều cách phối
hợp thi công hoặc độc lập thi công giữa hai phần việc đó, hoặc xen kẽ, hoặc kết
hợp cả hai. Với kinh nghiệm của mình, dạng công trình khung BTCT nhiều tầng
nhà thầu chọn cách thi công sau đây:
Tiến hành thi công BTCT trước một bước như sau:
+ Trước hết lắp dựng cốt thép vách tầng hầm đến sàn tầng trệt cốt +1,500m (từng
tầng một).
+ Ghép cốt pha thép được gia công đinh hình cho từng tầng một .
+ Tiến hành đổ bê tông cho từng tầng cột vách từ cốt sàn tầng hầm đến đáy dầm
của sàn tầng trệt.
+ Khi cột vách, vấu chờ được đổ bê tông xong một số trục, tiến hành ngay việc
thi công giáo chống đáy dầm tiền chế .
Từ tầng lửng đến hết tầng mái trình tự tương tự như trên .
Tại điểm thi công tầng 1 cốt +7.3 khi đã đủ thời gian cho phép giải phóng cốp
pha giáo chống tầng hầm đến hết sàn tầng trệt cốt +1,5, lúc đó sẽ bắt đầu tiến
hành mũi thi công thứ hai: đó là xây tường ngăn, công tác xây được thực hiện
đồng bộ theo bảng tiến độ tổng thể dựa trên cơ sở: phần xây luôn cách phần bê
tông sàn là 03 tầng giáo.
Từ đó trở đi hai mũi đổ bê tông cốt thép từ tầng 2 trở lên và mũi xây tường bao
che từ tầng hầm trở lên được tiến hành đồng thời theo phương pháp cuốn
chiếu, xong đến đâu gọn đó cho đến mái.
Công tác trát tường cũng được bắt đầu thực hiện khi các mảng tường xây đầu tiên
đã đủ thời gian đặc chắc và khô hết nước (ít nhất phải ≥15-20 ngày).
c. Biện pháp chống lạt lỡ hố đào
Vật liệu sử dụng Thép hình : I200,I150,U120, thép tấm dày 2mm.
EF$GaLQh&&i&jklmnibb&Trang
16
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
PHẦN 4
CÔNG TÁC KIỂM TRA VÀ NGHIỆM THU CỐT THÉP BÊ TÔNG
I/ Biện pháp gia công cốt thép:
•
•
Đònh vò các tuyến tim cột, dầm, kiểm tra ván khuôn cột bằng : máy kinh vỉ, dăy
Đònh vò các tuyến tim cột, dầm, kiểm tra ván khuôn cột bằng : máy kinh vỉ, dăy
dọi…
dọi…
•
•
Xác đònh độ cao thiết kế, quy họach độ cao chuẩn bằng dụng cụ: Máy kinh vỉ, dây
Xác đònh độ cao thiết kế, quy họach độ cao chuẩn bằng dụng cụ: Máy kinh vỉ, dây
dọi, thước thép…
dọi, thước thép…
Cốt thép được đưa tới công trình và được tập kết tại bãi có bạc che chắn .
Thép gồm các loại CI, CII, CIII: Loại D<10 CI có Ra = 2200kg/cm2. Loại d ≥10 CII có
Ra = 2800kg/cm2. Loại d ≥ 18 CIII có Ra=3400kg/cm2.
hép được bốc xếp vận chuyển trên mặt bằng và lên các tầng cao bằng cẩu vận thăng.
Thép được gia công bằng máy cắt uốn tại bãi hiện trường.
Công tác kéo thép, nắn thép: Công tác này được thực hiện đối với thép D <10 dùng tời
kéo có mâm quay.
Cắt cốt thép: Sử dụng máy cắt C150
Uốn cốt thép: Sử dụng máy uốn thép Viltara để gia công.
Trước khi cắt uốn Kỹ sư của đơn vò thi công sẽ tiến hành thống kê thép - bản đề tay
chuyển cho công nhân lành nghề đọc hiểu và cắt mẫu sau đó cắt, uốn đại trà.
Để đảm bảo kích thước thanh được chính xác sau khi uốn thì ta cần phải tiến hành kiểm
tra độ dài thanh trước khi uốn, mọi tính toán độ dài thanh cần phải dựa vào độ giãn dài
của thép.
Với các kết cấu thép đòi hỏi độ chính xác về chiều dài thanh, tuyệt đối quan tâm tới độ
dài của thanh thép trước khi uốn.
Công tác hàn cốt thép (với những mối nối yêu cầu hàn): Mối hàn phải đảm bảo đặc
chắc không rỗ, không vẩy.
Chiều dài mối hàn không < 10d ( ≥ 10d )/mối
Buộc cốt thép: Liên kết thép cột, dầm sàn áp dụng cho công trình là thép buộc, thép
buộc được sử dụng là loại thép dây 1mm.
Biện pháp lắp dựng cốt thép :
+ Lắp dựng cốt thép cột: Xác đònh chính xác tim cốt của cột theo 2 phương
Vệ sinh sạch sẽ khu vực chân cột + thép chờ bằng máy nén khí, bàn chải sắt
Kiểm tra số lượng, đường kính, chủng loại thép theo hồ sơ thiết kế.
Căn chỉnh cốt thép dọc (chờ) cho đúng kích thước
Lồng sẵn cốt thép đai với số lượng đã đếm đủ cho chiều dài tiêu chuẩn kết cấu.
Đưa cốt thép dọc chòu lực nối với thép chờ theo đúng tiêu chuẩn neo nối.
Sau khi nối xong cốt thép dọc ta nâng cốt đai lên buộc theo khoảng cách đai thiết kế
yêu cầu cho tới độ cao 1,5m thì bắc giáo rồi buộc tiếp lên phía trên.
Giữ ổn đònh cột bằng dây neo 2 phương (nếu cần)
Nghiệm thu nội bộ đạt yêu cầu trước khi mời tư vấn giám sát nghiệm thu.
EF$GaLQh&&i&jklmnibb&Trang
17
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
+ Lắp dựng cốt thép dầm (cho các dầm khoá toàn khối): Sau khi lắp dựng xong ván đáy
dầm ta tiến hành lắp dựng cốt thép của dầm.
Vệ sinh bề mặt cốp pha, lắp dựng giáo + sàn thao tác.
Luồn cốt thép cấu tạo vào các thanh đỡ bên trên, cốt đai được đếm đủ số lượng luồn
vào thép cấu tạo và được gom thành từng bó phù hợp với số lượng từng đoạn sau đó
luồn cốt thép chòu lực vào cốt đai .
Rải cốt đai kết cấu theo thiết kế và buộc các cốt thép chòu lực vào cốt đai tạo lên
khung dầm theo đúng thiết kế về cấu tạo và hình học.
Rút thanh đỡ, hạ cốt thép xuống đáy dầm khi đã bố trí con kê bê tông đầy đủ dưới đáy
dầm.
Nghiệm thu nội bộ đạt yêu cầu trước khi mời tư vấn giám sát thi công nghiệm thu.
Lắp dựng ván thành sau khi lắp dựng xong cốt thép dầm đã được nghiệm thu.
Lắp dựng cốt thép sàn: Cốt thép sàn được lắp dựng sau khi đã lắp dựng xong côppha
sàn
Kiểm tra lại tim cốt, kích thước hình học
Buộc cốt thép theo phương chòu lực hoặc cấu tạo. Buộc thành lưới cốt thép sàn bằng
dây thép buộc 1 mm tại các nút. Các nút buộc có thể bố trí buộc so le. Cốt thép âm,
thép gia cường sẽ được tổ hợp và lắp buộc sau cùng khi lưới thép sàn đã cơ bản ổn đònh
về hình học.
Thép ngang mặt dầm phai buộc 100% vào thép dọc của dầm.
Dùng các viên kê bê tông có chiều dày lớp bảo vệ theo thiết kế được qui đònh cho công
trình cho mỗi hạng mục, buộc chặt vào lưới thép tại các nút.
Nghiệm thu nội bộ đạt yêu cầu trước khi mời tư vấn giám sát thi công nghiệm thu
EF$GaLQh&&i&jklmnibb&Trang
18
Cốp pha cột
Cốp thép sàn
Bê tông sàn sàn
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
ghi chó
d©y thõng
sµn c«ng t¸c
d©y an toµn
cét ®· ®ỉ bª t«ng
thÐp chê cét, v¸ch
biƯn ph¸p l¾p bc cèt thÐp dÇm sµn
bb
r©u thÐp neo s½n trong bª t«ng
a-a
sµn bª t«ng ®· ®ỉ
b-b
sµn bª t«ng ®· ®ỉ
d©y neo xµ gå ngang xng sµn
chi tiÕt lan can an toµn
®Ĩ mãc d©y an toµn
D©y thõng (bc vµo thÐp chê cét)
thÐp chê cét
d©y an toµn
lan can an toµn
xµ gç ®ì ®¸y dÇm
xµ gå ngang
sµn c«ng t¸c
500
D©y thõng (bc vµo thÐp chê cét)
d©y an toµn
®Ĩ mãc d©y an toµn
thÐp chê cét
sµn c«ng t¸c
d42
èng thÐpd©y thõng
lan can an toµn
xµ gç ®ì ®¸y dÇm
xµ gå ngang
sµn c«ng t¸c (b»ng t«n)
d©y thõng (bc vµo thÐp chê cét)
®Ĩ mãc d©y an toµn
a a
sµn c«ng t¸c
thÐp chê cét, v¸ch
sµn bª t«ng ®· ®ỉ
- biƯn ph¸p nµy ®c ¸p dơng cho tÊt c¶ c¸c dÇm biªn, gi÷a
- c«ng t¸c chn bÞ ph¶i xong vµ ®c cbkt nghiƯm thu
trc khi lµm viƯc.
II / Công tác kiểm tra và nghiệm thu cốt thép.
Kiểm tra công tác công tác cốt thép bao gồm các phần việc sau: Sự phù hợp của
các loại cốt thép đưa vào sử dụng so với thiết kế. Công tác gia công cốt thép; phương
pháp cắt, uốn và làm sạch bề mặt cốt thép trước khi gia công.
Công tác hàn : Công trình không cho phép hàn nối cột thép, mọi công tác hàn
trên công trường chủ yếu là phục vụ cho biện pháp thi công, vì vậy vấn đề cần lưu ý
nhất trong quá trình hàn là biện pháp an toàn cháy nổ, chập điện
Việc nghiệm thu công tác cốt thép phải tiến hành tại hiện trường để đánh giá
chất lượng công tác cốt thép so với thiết kế trước khi đổ bê tông.
Biện pháp vận chuyển cẩu lắp
Do diện thi công hẹp và phải vận chuyển vật liệu theo phương thẳng đứng, đơn vò
thi công sử dụng vận thăng để vận chuyển thép từ vò trí bãi tập kết dưới đất lên sàn
công tác trên cao.
Khâu chuẩn bò:Thép thành phẩm phải được bó chặt thành từng bó. Cáp buộc, vật
kê cần phải kiểm tra chuẩn bò đầy đủ. Sàn thao tác phải đủ rộng và đảm bảo đủ độ chắc
chắn để có thể tập kết thép thành phẩm.
Tổ chức thi công cốt thép
Để thi công liên tục, nhòp nhàng và đảm bảo các yêu cầu công việc chúng ta chia
mặt bằng thi công phần thân từ tầng hầm đến mái được chia làm từng tầng:
An toàn lao động:
- Tuân thủ nội quy an toàn chung.
- Ngoài ra còn phải thực hiện các điều kiện sau:
EF$GaLQh&&i&jklmnibb&Trang
19
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
+ Gia công cốt thép:
- Trước khi vận hành máy phải kiểm tra tình trạng máy.
- Tại các máy phải có nội quy an toàn riêng của từng máy.
- Thợ vận hành máy phải là thợ có kinh nghiệm, được hướng dẫn sử dụng máy và
các quy trình vận hành an toàn.
- Hết giờ làm việc phải cắt điện và che đậy máy đúng yêu cầu.
+ Lắp buộc cốt thép:
- Thi công đứng trên cao cách mặt sàn > 2m phải đeo dây an toàn và móc vào vò
trí chắc chắn.
- Đứng trên giáo thi công phải neo buộc chắc chắn
- Thi công dầm biên phải có lan can an toàn chắc chắn, công nhân làm việc phải
deo dây an toàn
III. Biện pháp thi công cốt pha.
a. Vật tư sử dụng.
Căn cứ vào hình dạng, kích thước, tiết diện của các hạng mục kết cấu công trình,
đơn vò thi công chọn phương án sử dụng cốp pha thép đònh hình bao gồm:
- Các tấm ván khuôn đònh hình cho vách (dùng tôn panen đònh hình)
- Các phụ kiện liên kết móc thép U, chốt A, bu lông
- Tăng đơ + cáp kéo D12
- Xà gồ thép Hôp100x50,40x80,50x50
- Cây chống kim loại (chống đơn)
- Hệ giáo chống( giàn giáo thép)
b. Biện pháp lắp dựng ván khuôn vách, dầm, sàn.
Trình tự thi công cụ thể:
- Thi công cốp pha chia làm từng tầng
- Thi công cốp pha vách:
+ Công tác chuẩn bò:
-Trắc đạc: Đònh vò tim và mép cốp pha trên mặt sàn bê tông đã đổ. Đường gửi
cách tim cấu kiện 1000 mm để kiểm tra.
-Hàn chân cữ vào vò trí các góc vách.
-Vệ sinh sạch tấm cốp pha, bôi dầu chống dính.
+ Công tác lắp dựng:
- Tổ hợp tôn đúng vò trí, kích thước hình học
- Lắp dựng chống chéo.
- Căng cáp và tăng đơ.
- Căn chỉnh thep phương đứng (dùng cây chống và tăng đơ)
- Chèn các khe hở nhỏ bằng mút mềm hoặc vữa
EF$GaLQh&&i&jklmnibb&Trang
20
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
c. Tháo dỡ cốp pha đà giáo.
Cốp pha đà giáo chỉ được tháo dỡ khi bê tông đạt cường độ cần thiết để kết cấu
chòu được trọng lượng bản thân và các tải trọng tác động khác trong giai đoạn thi công
sau. Khi tháo dỡ cốp pha, đà giáo, cần tránh không gây ứng suất đột ngột hoặc va chạm
mạnh làm hư hại đến kết cấu bê tông.
Các bộ phận đà giáo không còn chòu lực sau khi bê tông đã đông rắn (như cốp
pha thành bên của dầm, cột, vách) có thể được tháo dỡ khi bê tông đạt các giá trò cường
độ trên 50 daN/cm
2
- sau từ 12 đến 24 giờ.
Đối với cốp pha đà giáo chòu lực của các kết cấu (đáy dầm, sàn, cột chống), nếu
không có các chi tiết chỉ dẫn đặc biệt của thiết kế thì được tháo dỡ khi bê tông đạt các
giá trò cường độ và được phép của tổ giám sát và Chủ đầu tư.
Các kết cấu ô văng, công xôn, sê nô chỉ được tháo cột chống và cốp pha đáy khi
cường độ bê tông đạt đủ mác thiết kế và đã có đối trọng chống lật.
Trình tự tháo dỡ cốp pha theo trình tự từ ngoài vào trong và từ trên xuống dưới.
Khi tháo dỡ cốp pha ở các tấm sàn đổ bê tông toàn khối phải giữ lại toàn bộ đà giáo và
cột chống ở tấm sàn đổ bê tông nằm kề dưới tấm sàn sắp đổ bê tông, tháo dỡ từng bộ
phận cột chống cốp pha của tấm sàn phía dưới nữa và giữ lại các cột chống an toàn
cách nhau 3 m dưới các dầm có nhòp lớn hơn 4m.
d. An toàn lao động:
- Tuân thủ các nội quy an toàn chung.
- Giáo, cốp pha tôn vận chuyển bằng vận thăng.
- Ống nối và chân kích phải cho vào ben và vận chuyển lên cao.
- An toàn về điện khi sử dụng máy hàn.
- Thi công trên cao, ngoài mép công trình bắt buộc phải đeo dây an toàn và móc
buộc vào vò trí chắc chắn.
IV. Biện pháp thi công bê tông
EF$GaLQh&&i&jklmnibb&Trang
21
Cốp pha sàn
Cốp pha cổ cột
Cốp pha cầu thang
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
Bê tông kết cấu công trình (cột, dầm, sàn vv) sử dụng loại bê tông, sản xuất tại:
trạm thương phẩm, được trộn và vận chuyển tại công trường bằng xe chuyên dụng vừa
dừng vừa quay, sức chứa tối đa là 6m
3
/xe, có thể yêu cầu đến khối lượng tối thiểu
là 0,5m3/xe đối với bê tông của các kết cấu đặc biệt như vai đỡ dầm, bê tông giáp
lõi,khi xe bê tông đến công trường phải lay mẫu kiểm tra độ sục như sau:
Mẫu thí nghiệm được lấy theo lô, theo cấu kiện và theo chức năng đại diện cho
từng loại kết cấu (cột vách,dầm, sàn vv) theo tiêu chuẩn bằng khuôn cơ khí chính xác
150x150x150, mỗi tổ gồm ba mẫu, trên mặt mẫu nghi rõ ngày tháng mã mác (có biên
bản lấy mẫu thí nghiệm kèm theo) bảo dưỡng tại hiện trường ít nhất 72 giờ sau đó
lập lý lòch chuyển đến phòng thí nghiệm thành phố (hợp chuẩn quốc gia) tiếp tục bảo
dưỡng để nén ở tuổi 7 ngày và 28 ngày trước sự chứng kiến của Tư vấn giám sát.
Bê tông được đổ chủ yếu bằng xe bơm chuyên dụng cho các cấu kiện lớn,các cấu
kiện nhỏ còn lại được đổ bằng thủ công
Đơn vò cấp bê tông sẽ trình bản thiết kế cấp phối bê tông các mác thiết kế cho
Chủ đầu tư và Tư vấn giám sát trước khi đưa sản phẩm bê tông vào sử dụng. Lấy mẫu
bê tông tại hiện trường nhằm đảm bảo chất lượng cho việc đổ bê tông và kiểm tra
cường độ bê tông theo thời gian liên kết.
Kiểm soát kích thước khối đổ bê tông và cao độ đổ bê tông bằng máy thuỷ bình
và thước thép.
EF$GaLQh&&i&jklmnibb&Trang
22
Bảo dưỡng
bê tông
Kiểm tra độ sục
Lấy mẫu
Đo độ sục
Đổ bê tông sàn
Phòng thí nghiệm
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
Kiểm tra cốp pha, cốt thép và chỉ được tiến hành đổ bê tông khi đã được nghiệm
thu nội bộ của đơn vò, nghiệm thu của Tổ tư vấn giám sát thi công.
V. Biện pháp thi công bê tông vách tầng hầm
Trước khi đổ bê tông cần vệ sinh bên trong cốp pha thông qua cửa vệ sinh, tưới
nước để cốt thép và ván khuôn có đủ độ ẩm tránh hiện tượng vữa bê tông bò khô tại vò
trí tiếp giáp với cốt thép và thành cốp pha
Đổ bê tông thành nhiều lớp mỗi lớp dày ≤ 0.5m đều xung quanh sau đó đổ lớp
tiếp theo.
Đầm bê tông theo từng lớp. Khi sử dụng đầm dùi, bước di chuyển của đầm không
vượt quá 1,5 lần bán kính tác dụng của đầm và phải cắm sâu vào lớp bê tông đã đổ
trước 10cm. Sau khi đầm xong 1 vò trí đầm phải rút lên từ từ và không được tắt công tắc.
Vách được đổ bê tông đến cốt đáy dầm.
Sau khi đổ xong cần phải kiểm tra lại độ thẳng đứng của vách (nhằm khắc phục
ngay sai lệch có thể xảy ra trong quá trình thi công)
VI Biện pháp đổ bê tông.
Trước khi đổ bê tông sàn ta phải vệ sinh ván khuôn bằng cách dùng máy nén khí
kéo dây dẫn mềm và cần xòt khí dài 1.2m đi thổi toàn bộ mặt sàn, đáy dầm và đặc biệt
là các đầu cột. Đối với các mẩu phoi bào, gỗ vụn không thể thổi bay được sẽ dùng
thanh thép mài nhọn đầu để xâu từng mẩu một và chuyển ra khỏi mặt ván sau đó tưới
nước rửa sàn đảm bảo cho ván khuôn đủ độ ẩm và sạch sẽ.
Đổ bê tông đổ từ xa tới gần theo các mạch ngừng đã đặt.
Trong quá trình đổ bê tông và làm mặt đơn vò thi công luôn bố trí các mốc cao độ
sẵn trên mặt sàn kiểm tra và báo hiệu cốt mặt trên của dầm, sàn.
Quá trình đổ BT sàn phải chú ý tới bề dày thiết kế của sàn để đảm bảo bê tông
đổ đủ kích thước, không được đi lại nhiều trên cốt thép trong khi đổ.
Trong quá trình thi công bê tông ngoài yêu cầu về kỹ thuật cần quan tâm đặc biệt
tới các chi tiết chôn sẵn, thép chờ, hộp kỹ thuật trong bê tông để tránh phải đục sửa sau
khi đổ bê tông.
VII. Phương pháp đầm bê tông.
Việc đầm bê tông phải đảm bảo các yêu cầu sau:
Có thể dùng các loại đầm khác nhau, nhưng phải đảm bảo sao cho sau khi đầm
bê tông được đầm chặt và không bò rỗ. Thời gian đầm tại mỗi vò trí phải đảm bảo cho
bê tông được đầm kỹ. Dấu hiệu để nhận biết bê tông đã được đầm kỹ là vữa xi măng
nổi lên bề mặt và bọt khí không còn nữa.
Khi sử dụng đầm dùi, bước di chuyển của đầm không vượt quá 1,5 lần bán kính
tác dụng của đầm và phải cắm sâu vào lớp bê tông đã đổ trước 10cm. Sau khi đầm xong
1 vò trí đầm phải rút lên từ từ và không được tắt công tắc.
Phương pháp bảo dường bê tông:
Sau khi đổ từ 6-8 giờ, bê tông phải được bảo dưỡng trong điều kiện có độ ẩm và
nhiệt độ cần thiết để đóng rắn nhờ phản ứng thuỷ hoá của xi măng và ngăn ngừa các
chấn động trong quá trình đóng rắn của bê tông .
EF$GaLQh&&i&jklmnibb&Trang
23
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
Bảo dưỡng ẩm là quá trình giữ cho bê tông có đủ độ ẩm cần thiết để ninh kết và
đóng rắn sau khi tạo hình. Phương pháp và qui trình bảo dưỡng ẩm thực hiện theo
TCVN 5592 : 1991.
Thực hiện theo qui phạm TCVN 4055-85 và vữa XD theo TCVN 4459-87.
VIII.Công tác xây.
Quá trình xây chỉ được thực hiện sau khi đã tháo dỡ toàn bộ cây chống và cốp
pha sàn tầng 4 (Theo bảng tổng tiến độ thi công). Quá trình xây được tiến hành từ tầng
1 trở lên.Trước khi xây dùng máy kinh vó, thuỷ bình xác đònh tim trục, cao độ đầy đủ.
Bật mực màu nối các mốc xác đònh chính xác vò trí bức tường trên mặt bằng sàn.
Vữa xây: dùng cốt liệu theo yêu cầu thiết kế, có bảng thiết kế cấp phối cho từng
mác vữa, vữa được trộn bằng máy, bên cạnh máy có đặt 01 bảng trắng ghi rõ tỉ lệ cấp
phối trộn cho từng mác vữa
Gạch xây: dùng gạch chỉ theo mác thiết kế do Nhà máy sản xuất, được sự đồng ý
của Ban quản lý dự án và tư vấn giám sát trước khi tập kết vào công trình, gạch có kích
thước theo tiêu chuẩn.Vữa xây theo hồ sơ thiết kế và theo bảng chỉ dẫn của Ban quản
lý dự án.
Tổ chức hệ thống giáo xây, mỗi đợt giáo cao 1,5m.
Trên công trường sử dụng dàn giáo thép để thi công.
Khi xây phải căng dây để đảm bảo độ phẳng của tường. Để đảm bảo độ thẳng
đứng của mặt phẳng tường phải dùng dây dọi và thước nivô dài 2m.
Trước khi xây phải tưới nước ướt gạch để đảm bảo độ ẩm và tăng cường sự liên
kết của khối xây.
Khối xây phải đảm bảo độ đặc chắc, không trùng mạch, no mạch. Khi kết thúc
phần xây của mỗi đợt đều phải được kiểm tra và hoàn công tim cốt.
EF$GaLQh&&i&jklmnibb&Trang
24
Xây tường
Tường ngăn
BÁO CÁO THỰC TẬP TỐT NGHIỆP XDDD & CN
Các lỗ chờ, đường điện nước, thông gió, thông tin, cứu hoả được đònh vò trước khi
đặt gạch để tránh đục phá làm ảnh hưởng đến chất lượng khối xây. Các trục điện nước
tập trung cần đặt sẵn trước khi xây tường.
Bảo dưỡng khối xây theo quy phạm. Khi xây và mới xây xong cần được tưới
nước một vài lần trong những ngày đầu để khối xây phát triển cường độ tốt, tránh vữa
bò khô xác do gạch hút hết nước.
Vữa xây được sàng kỹ loại sạn sỏi, tạp chất, trộn nhuyễn. Mác vữa và tỷ lệ cấp
phối đúng thiết kế.
Không đi lại trên bức tường mới xây. Không gây chấn động, rung chuyển, tựa các
vật nặng vào tường
PHẦN 5
BIỆN PHÁP THI CÔNG GIÁO NGOÀI
I. GIỚI THIỆU CHUNG
- Công trình Nhà thuộc dự án: Nhà cao KoRđộ đỉnh mái 33m, để đảm
bảo an toàn trong quá trình thi công và đảm bảo vệ sinh môi trường xung quanh không
làm ảnh hưởng đến sinh hoạt của các hộ dân cũng như việc đi lại của dân trong khu vực
lân cận.
- Xung quanh công trình cần thiết phải có hệ thống lưới bảo vệ ngăn bụi và vật
văng ra ngoài theo chiều đứng, lưới ngang để đỡ các vật rơi từ trên xuống.
- Trong quá trình thi công để đảm bảo an toàn lao động xung quanh công trình
phải lắp hệ thống dàn giáo bao
II. BIỆN PHÁP DÀN GIÁO:
Giáo được lắp cách mép công trình 0,3m và được giằng vào công trình bằng bộ
neo giáo (xem bản vẽ chi tiết). Từ đợt 2 trở đi dàn giáo được lắp trên hệ giá đỡ bằng
thép I150 kết hợp với cây chống và các chi tiết neo
III. BIỆN PHÁP LƯỚI AN TOÀN:
*) Lưới đỡ vật rơi từ trên cao:
-Hệ thống lưới được mắc bao quanh chu vi công trình với khẩu độ 4 tầng một lần
-Lưới phải đảm bảo độ bền để hứng được vật nặng rơi từ độ cao 4 tầng xuống
*) Lưới chắn bụi và đỡ vật rơi cao văng ra:
Để đảm bảo an toàn cho các công trình lân cận và vệ sinh môi trường cần thiết
phải có hệ thống lưới bao quanh công trình. Hệ thống lưới này được lắp từ tầng 3 lên
đến quá tầng cuối cùng. Hệ thống lưới bao gồm:
Lưới chắn bụi và đỡ vật văng phải đảm bảo các yếu tố về độ bền lâu dài, ít chòu ảnh
hưởng của khí hậu.
EF$GaLQh&&i&jklmnibb&Trang
25