Tải bản đầy đủ (.ppt) (43 trang)

Tài liệu đẹnn xe ô tô Hyundai I10 Getz

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (1.19 MB, 43 trang )

2002. 3.
2002. 3.
Technical Service Training Center
Technical Service Training Center
New Model Service Training
VEHICLE : TB(Gets)
- 2 -
Chonan TSTC
Newly Adapted Item in the Body Electrical other parts when compare with
New ACCENT.

ETACS section
- Power window timer
- Crash door unlock control from A/BAG
- Battery Saver Control(Tail Lamp Auto Cut Control)
- One button in-key type transmitter
- Using B/Alarm horn instead of siren & receive antenna built in ETACSCM
- Key Code Saving Use by Hi-scan

Body Electrical section
- In-Panel Junction Box
- Head Lamp Circuit Relay-less type
- Front Wiper Motor Control Relay-less type
- One Cooling Fan Motor type
- Body-less Multi function switch


Body Electrical System section
- Trip Computer

Electrical General


- 3 -
Chonan TSTC
ETACS Functions
Usually, functions that is controlled in ETACSCM are as flow items
However It explains about new function that explain here.

Defogger Timer Control

Ignition Key Reminder Control

Key Operated Warning Control WWW.OTO-HUI.COM

Seat Belt Warning Timer Control

Central Door Lock/Unlock Control

Power Window Timer Control

Crash Door Unlock Control

Battery Saver Control(Tail Lamp Auto Cut Control)

Room Lamp Decay Out Control & Keyless Unlock Timer

Keyless Entry Control

Anti-theft Control
- 4 -
Chonan TSTC
ETACS FUNCTION COMPARISON

Kind different function compare.
- 5 -
Chonan TSTC
Power Window Timer Control
Power Window Timer Control Time Chart
IGN. S/W
Driver’s or Assist
DR S/W
POWER
WINDOW MOT.
ON
OFF
OPEN
CLOSE
ON
OFF
* T1 : 30 ± 3 sec.
Power Window Off
T1
T1
Description
1. Power window output is “ON”, when IG. switch is turned “ON”.
2. Power window output should be OFF after maintaining ON for 30 seconds, when IG. switch is
turned OFF.
3. If the driver door or front passenger door is opened within 30 seconds, the power window output
must be off.
Remained time
- 6 -
Chonan TSTC
Crash Door Unlock Control

T1
T1 : 200mSEC. T2 : 40mSEC. T3 : 5 sec.
Air Bag Module
Crash Signal
Door Unlock
Output signal
Low
High
Unlock
Lock
Door Lock
Actuator
Unlock
Lock
T3
Door unlock signal output
from A/BAG control module
Air Bag Deploy
Condition
Deployment
Normal
T2
Crash Door Unlock Control Time Chart
Description
1. If the airbag signal is inputted to the ETACS when the door is locked, the
unlock signal is executed immediately for safety.
2. At this time, all door should be unlocked for operating above “unlock execution”.
WWW.OTO-HUI.COM
WWW.OTO-HUI.COM
- 7 -

Chonan TSTC
Battery Saver Control
Description
1. In case of the tail lamp switch is turned ON after IG. SW ON or the driver door
is opened after IG. SW OFF, the tail lamp is extinguished automatically.
2. In addition, the IG. SW is turned OFF after driver door is opened with IG. SW is ON
condition, the tail lamp will be extinguished automatically too.
3. After automatic extinguish, if the tail lamp switch is turned ON again,
then, the tail lamp will be ON (illuminating) and the auto cut function will be released.
IG. KEY
Switch
Inserted
Removed
ON
OFF
OPEN
CLOSE
TAIL LAMP
SWITCH
Driver’s Door
Switch
Lamp Auto Off
TAIL LAMP
(REALY)
ON
OFF
Lamp Auto Off
Battery Saver Control Time Chart(Tail Lamp Auto Cut)
- 8 -
Chonan TSTC

Room Decay Out Control
Room Lamp Delay Out after receive “Keyless Unlock” signal
FRT LH or RH
Door S/W
ON
OFF
IG. S/W
TX Button
T1
T2
Room Lamp
ON
OFF
UNLOCK
LOCK
ON
OFF
75%
* T1 : 5.5 ± 0.5 sec. * T2 : 30 ± 2 esc.
Description
1. Room lamp must be light ON when the door is opened. (door switch is ON)
2. The brightness of room lamp should be reduced to 75% immediately, and be dimmed off gradually
till the room lamp is OFF within 5 - 6seconds after the door is closed (door switch is OFF).
3. In case of the door open (door switch is ON) time is less than 0.1 second, then this function should
not be operated.
4. This system takes 32 steps to dim the room lamp.
5. While the delay and brightness dimming room lamp are operating, output of them must be OFF
immediately after IG. switch is ON.
- 9 -
Chonan TSTC

Room Decay Out Control
Room Lamp control after receive “Keyless Unlock or Lock” signal.
Description
1. The room lamp prolongs light “ON” about 30 sec. If the Transmitter unlock signal
receive with door is closed.
2. During room lamp operating by unlock signal of the Transmitter, lamp light goes OFF immediately
if receive ignition switch ON or lock signal of the Transmitter.
3. The room lamp keeps lighting “ON” in light “ON” when opening the door, the room
lamp is back to the delay function.
FRT LH or RH
Door S/W
Opened
Closed
Transmitter
T1
Room Lamp
UNLOCK
LOCK
ON
OFF
* T1 : 30 ± 2 esc. * T2 : 5.5 ± 0.5 sec.
T2
- 10 -
Chonan TSTC
Burglar Alarm Horn
1. Using Burglar Alarm Horn instead of Siren
2. Keyless Receive Antenna Built in the ETACS CM
3. Transmitter One Button type in Key
4. Door's Lock and unlock by ONE BUTTON that is combined with Ignition key.
ETACS CM

B/ALARM HORN
ONE BUTTON Type IN KEY
Transmitter
Lock LockUnlock Unlock
Unlock
Lock
Unlock
Lock
- 11 -
Chonan TSTC
Code Saving
ETACS CM
10 Pin RCT
Connector
ETACS CM
Key Code Saving Use for Hi-scan
Adapter Cable
Pin No 2 :Battery
Pin No 3 : Code Save for Anti theft system
- 12 -
Chonan TSTC
Code Saving Method by tool
Code saving method procedure when using Hi-scan. – non immobilizer vehicle
※ Application vehicle : New EF SONATA, Elantra XD, Metrix(FC), XG, TB
Code Saving Method using Hi-scan
- 13 -
Chonan TSTC
Code Saving Comparison
Vehicle
ETACS

Receiver
Location
Code Saving Tool
ICM Location
Code Saving Method
OFF/SET
S/W
Hi-scan Immobilizer
Non
Immobilizer
RCT
ground
Accent(LC) In ETACSCM O X In ECM Method 1 Method 1
Elantra XD In ETACSCM O O In ECM Method 1 Method 1
Metrix(FC) In ETACSCM O O In ECM Method 1 Method 1
EF Sonata
Out side of
ETACSCM
O X ETACS RX. Method 2 Method 1 O
New EF
Out side of
ETACSCM
O O ETACS RX Method 2 Method 1
XG In ETACSCM O O In ECM Method 1 Method 1 O
Traget XG In ETACSCM O X In ECM Method 1 Method 1
Santa-Fe In ETACSCM O X In ECM Method 1 Method 1
Atoz
Out side of
ETACSCM
O X In ECM Method 2 Method 2

Tarrcan(HP)
Out side of
ETACSCM
O X
ETACS RX
(3.5,2.5L)
In ECM(2.9L)
Method 2
Method 1
Method 1
New Coupe In BCM X O In BCM Method 1 Method 1
Centennial
Out side of
ETACSCM
O X ETACS RX. Method 3 Method 3
TB In ETACSCM X O In ECM Method 1 Method 1
Code Saving Method Comparison
- 14 -
Chonan TSTC
Code Saving Method 1 Non Immobilizer
Code Saving Method by tool – “Method 1” Non immobilizer
Code saving method procedure when using OFF/SET switch.
※ Application vehicle : All Vehicle except New EF SONATA, Elantra XD, Metrix(FC), XG,
TB, Centennial
1. Remove the IGN. key from the key cylinder.
OFF/SET switch is on “OFF” position at first.
2.Move the “OFF/SET” switch to “SET” position.

3.Push “Lock or Unlock” button of the Transmitter.


4.Move the “OFF/SET” switch to “OFF” position again.
OFF
SET
1
OFF SET
2
OFF
SET
4
Lock / Unlock Button
3
- 15 -
Chonan TSTC
Code Saving Method 2 immobilizer
.
2.Move the “OFF/SET” switch to “SET” position.
◐ OFF/SET switch is on “OFF” position at first
3. Push “Lock & Unlock” button of the
transmitter at the same time while 1sec.
and Lock or Unlock push once again while
1sec. If make to code save two transmitter
have do finish within 10seconds from
moved OFF/SET switch.
OFF SET
2
OFF
SET
4
4.Move the “OFF/SET” switch to “OFF”
position again

1. Ignition Key “ON” and wait for
more than 5 sec.
1
Off/Set switch
ICM
Antenna
※Off/Set switch
located on the ICM
※ ICM : Immobilizer Control Module
Off
Set
Code Saving Method by tool – “Method 2” with Immobilizer
Code saving method procedure when using OFF/SET switch
※ Application vehicle : New EF SONATA, Atoz, Terrcan 2.5L&3.5L, Centennial
Lock/Unlock Button
3
- 16 -
Chonan TSTC
Code Saving Method 3 Non immobilizer
Code Saving Method by tool – “Method 3” Non immobilizer
Code saving method procedure when using OFF/SET switch
※ Application vehicle : Centennial
※Off/Set switch
located on the ICM.
1.Move the “OFF/SET” switch to “SET” position.
◐ OFF/SET switch is on “OFF” position at first
2. Push “Lock & Unlock” button of the
transmitter at the same time while 1sec.
and Lock or Unlock push once again
while 1sec. If make to code save two

transmitter have do finish within 10seconds
from moved OFF/SET switch.
.
OFF SET
1
OFF
SET
3
3.Move the “OFF/SET” switch to “OFF”
position again
Off/Set switch
Antenna
Off
Set
Lock/Unlock Button
2
- 17 -
Chonan TSTC
IN-Panel Junction Box
Adapted IN-Panel Junction Box
IN-Panel Junction Box
FUSE & Relay Box
Fuse & Relay Box Back side
IN-Panel Junction Box
Circuit Board
New
ACCENT
Fuse
&
Relay Box

TB
Junction
Box

×