Speed and Coverage
When seconds count…
Cover 70cm in as little as 6 sec
 Multi-trauma case: cover the whole-body with a 2000 mm
scannable range

 Helps to scan patients with rapid respiration and high
irregular heart rates

 Fast Triple-rule Out & Rapid trauma examination: entire
thorax in 2.5s
voice forwith multiple
 Reduce sedation requirementsCustomer
for patient

fractures
or uncooperative patients
* Trademark of General Electric Company.

coverage

“In polytrauma study, Optima* CT660 offers the
possibility to scan quickly from the Circle of Willis to
lower limbs in one pass with high image
performance”
Dr. Nicolas Poussange, CH Pellegrin Bordeaux France

1


Speed and Coverage


When seconds count…

VolumeShuttle***

In Stroke cases, VolumeShuttle
improves the selection of different
treatment options up to 80 mm
coverage
for Head Perfusion study

Volume Helical Shuttle***

Abdominal pain with Volume
Helical Shuttle, up to 500 slices or
312.5mm coverage for 4D imaging
and Body Perfusion

* Trademark of General Electric Company.

2

** Option *** Trademark +


Speed and Coverage
Still with high image quality
 See more anatomical details and visualize smallest bone structures
 May help medical staff in clinical decision making: “surgical vs.
medical“ issue


Adaptive Enhance
Level Adjustment
(AELA)

Improves visual spatial
resolution while maintaining
pixel noise standard deviation
and artifact

IQ Enhance
(Pitch Booster)
Without IQE

With IQE

Allows faster pitch scanning covering more
anatomy at similar image quality (based
on artifact index). Up to 90% helical pitch
acceleration which can provide higher helical
pitch at same IQ level (based on artifact
index).

3


Polytrauma
Optima* CT660

Head to Pelvis
Region

• Patient History
82-year-old woman : accidental fall
Patient had hip and shoulder prosthesis
The emergency team decides to transfer the
patient in Emergency Department to undergo a
CT-scan on Optima* CT660



Acquisition Protocol

- 815 mm table travel in 6.7 s (Pitch 1.531)
- 0.5 sec/rot
-

40 mm collimation
0.625 mm slice thickness
120 kV
mA mod : 100-510
Noise index : 22
Kernel reconstruction : standard
ASiR: 50 %
DLP : 747 mGy.cm (eff dose value : 10.3 mSv)*1

*1 Courtesy of Pellegrin University Hospital, Bordeaux, 4
France
* Trademark of General Electric Company.


Polytrauma

Optima* CT660

Facial Region

Speed & Coverage

815 mm in 6.7 s
(Pitch 1.531)
0.5 sec/rot

Right fractured orbital bone showing a herniation of fat

Image Quality
Slice thickness 0.625 mm

Dose
DLP 747 mGy.cm
120 kV
mA mod 100-510
* Trademark of General Electric Company.
5
Courtesy of Pellegrin University Hospital, Bordeaux,


Polytrauma

Speed & Coverage

815 mm in 6.7 s
(Pitch 1.531)

0.5 sec/rot

Optima* CT660

Cervical, Thoracic
and Spine Region

Cervico-thoracic subcutaneous
emphysema

Traumatic pneumatoceles
localized to posterior segment
of the culmen

Image Quality
Slice thickness 0.625 mm
Dose
DLP 747 mGy.cm
120 kV
mA mod 100-510

Compression of T9 and T12
vertebrea

Bi-pediculare fracture of C2
6
* Trademark of General Electric Company.
Courtesy of Pellegrin University Hospital, Bordeaux,



Polytrauma
Optima* CT660

Pelvis Region

Speed & Coverage

815 mm in 6.7 s
(Pitch 1.531)
0.5 sec/rot

Fracture of the inferior pubic
ramus
Fracture of the posterior pillars of
acetabulum

Image Quality
Slice thickness 0.625 mm
Dose
DLP 747 mGy.cm
120 kV
mA mod 100-510

Fracture of Ischio-pubic segment
* Trademark of General Electric Company.
7
Courtesy of Pellegrin University Hospital, Bordeaux,


Polytrauma

Optima* CT660

Head Region

Speed & Coverage

815 mm in 6.7 s
(Pitch 1.531)
0.5 sec/rot

Swelling of soft tissues with significant premaxillary bone loss
associated

Image Quality
Slice thickness 0.625 mm
Dose
DLP 747 mGy.cm
120 kV
mA mod 100-510

8
* Trademark of General Electric Company.
Courtesy of Pellegrin University Hospital, Bordeaux,


Polytrauma
Optima* CT660

Technology
Workflow

Radiographer was able to quickly position the trauma patient on the table thanks to Default Patient
Positioning on gantry display.
With one stop scanning mode, prescanning was performed in only five touches including: patient and
protocol selection.
Imaging Performance
The Optima* CT660’s high helical pitch of 1.531 enabled coverage from head to pelvis
(815 mm) in 6.7 sec with 40 mm beam width at 0.5sec rotation speed.
The patient was scanned at a low dose of 747 mGy.cm (10.3 mSv*1) thanks to ASiR* while maintaining a
high image performance with 0.625 mm slice thickness.
(*1 Obtained by EUR-16262
EN)

Conclusion

With its imaging capabilities, the Optima* CT660 allowed the radiologist conduct a head-to-pelvis scan within a
few seconds with low dose.
More important the CT-scan offered a high diagnostic image quality, which enabled in this case detection of a
thin fracture near the metallic hip prosthesis.
Courtesy of Pellegrin University Hospital, Bordeaux,
France
* Trademark of General Electric Company.

9


Acquisition from Head to legs
Polytrauma
Multi reconstructions in Standard, Lung, Bone

CT Angiography from C.O.W. to Iliac arteries in only one

acquisition

Outstanding Image Quality with ASiR*

Optima* CT660

41-year-old Patient : Motor Vehicle
Accident

Courtesy of Pellegrin University Hospital, Bordeaux,
France
* Trademark of General Electric Company.


Optima* CT660

Full Body
CT

peed & Coverage

696 mm in 14.5 sec
Pitch 1.531)
.5 sec/rot

mage Quality
ice thickness 1.25 mm

ose
LP 1455 mGy.cm

TDI 8.3
20 kV
A mod 100-491

11
* Trademark of General Electric Company.
Courtesy of Pellegrin University Hospital, Bordeaux,


Speed & Coverage

Optima* CT660

Femur
Fractur
e
635 mm in 5.4 sec
(Pitch 1.531)
0.5 sec /rot
Image Quality
Slice thickness 0.625 mm
Dose
DLP 988 mGy.cm
CTDI 9
120 kV
mA mod 100-521

12
* Trademark of General Electric Company.
Courtesy of Pellegrin University Hospital, Bordeaux,



Optima* CT660

L3
Fracture

Speed & Coverage

910 mm*1 in 7.8 sec
(Pitch 1.531)
0.5 sec /rot
Image Quality
Slice thickness 0.625 mm
Dose
DLP 969 mGy.cm*1
CTDI 10.1
120 kV
mA mod 100-340

5 anatomical regions acquired in
969mGy.cm (2,300mGy.cm EUR)
*1 Head-neck-thoracic-abdomen-pelvis

* Trademark of General Electric Company.
13
Courtesy of Pellegrin University Hospital, Bordeaux,


Optima* CT660


Pelvis
Fracture

peed & Coverage

01 mm in 7.72 sec
Pitch 1.531)
.5 sec/rot

mage Quality
ice thickness 0.625 mm

ose
LP 752 mGy.cm
TDI 7.7
20 kV
mA mod 100-407

* Trademark of General Electric Company.

14
Courtesy of Pellegrin University Hospital, Bordeaux,


Speed & Coverage

Optima* CT660

Rib Fractures

&
Pneumothora
621
mm in 7.4 sec
x
(Pitch 1.531)
0.7 sec/rot
Image Quality
Slice thickness 1.25 mm
Dose
DLP 1196 mGy.cm
CTDI 17
120 kV
mA mod 420-437

15
* Trademark of General Electric Company.
Courtesy of Pellegrin University Hospital, Bordeaux,


Optima* CT660 Capabilities in ER
Image gallery
 Trauma

Abdominal Pain
 Stroke & Head Injuries
16
* Trademark of General Electric Company.



Speed & Coverage

Optima* CT660

AAA
Prosthesi
s
505 mm in 4.3 sec
(Pitch 1.531)
0.5 sec/rot
Image Quality
Slice thickness 0.625 mm
Dose
DLP 670 mGy.cm
CTDI 11.7
120 kV
mA mod 320-460

* Trademark of General Electric Company.
17
Courtesy of Pellegrin University Hospital, Bordeaux,


Speed & Coverage

Optima* CT660

AAA
Prosthes
is

505 mm in 4.3 sec
(Pitch 1.531)
0.5 sec/rot
Image Quality
Slice thickness 0.625 mm
Dose
DLP 670 mGy.cm
CTDI 11.7
120 kV
mA mod 320-460

* Trademark of General Electric Company.
18
Courtesy of Pellegrin University Hospital, Bordeaux,


Optima* CT660

Left Kidney
Hemorrhage

peed & Coverage

445 mm in 5,34 sec
Pitch 1.531)
0.7 sec/rot

mage Quality
lice thickness 0.625 mm


ose
LP 575.7 mGy.cm
TDI 11.3
20 kV
mA mod 250-319

19
* Trademark of General Electric Company.
Courtesy of Pellegrin University Hospital, Bordeaux,


Optima* CT660 Capabilities in ER
Image gallery
 Trauma
 Abdominal Pain

Stroke & Head
Injuries
20
* Trademark of General Electric Company.


Speed & Coverage

168 mm in 2.3 sec
(Pitch 1.531)
0.8 sec/rot

Optima* CT660


Head
Injury

Image Quality
Slice thickness 0.625 mm
Dose
DLP 237.8 mGy.cm
CTDI 12.5
120 kV
mA mod 119-147

* Trademark of General Electric Company.
21
Courtesy of Pellegrin University Hospital, Bordeaux,


COW
Optima* CT660

Speed & Coverage

157 mm in 1.3 sec
(Pitch 1.531)
0.5 sec/rot

Image Quality
Slice thickness 0.625 mm

Dose
DLP 159.6 mGy.cm

CTDI 8
120 kV
mA mod 118-166

22
* Trademark of General Electric Company.
Courtesy of Pellegrin University Hospital, Bordeaux,


TMax

CBF

MTT

Optima* CT660

Stroke
CT Perfusion 4D

CBV

Tissue
Classification

Courtesy of Pellegrin University Hospital, Bordeaux,

23

* Trademark of General Electric Company.



Optima* CT660

Angio 4D
* Trademark of General Electric Company.
24
Courtesy of Pellegrin University Hospital, Bordeaux,


Optima* CT660

Brain
Hemorrhage
Speed & Coverage

181 mm in 2.5
sec
(Pitch 1.531)
0.8 sec/rot
Image Quality
Slice thickness
1.25 mm

Pre-surgery

Dose
DLP 217.7 mGy.cm
CTDI 10.8
120 kV

mA mod 119-248

Post-surgery
* Trademark of General Electric Company.

Courtesy of Pellegrin University Hospital, Bordeaux,

25


×