Tải bản đầy đủ (.pdf) (2 trang)

KRONE F/FTP 450/23 F/FTP 450/23 FRNC Cat. 6 Cable

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (46.2 KB, 2 trang )





Subject to availability and technical change without
notice

Copyright © 2003 MK


0637-0013-15_Krone-U_FTP450_23_Kat.6_e.doc


KRONE F/FTP 450/23
F/FTP 450/23 FRNC Cat. 6 Cable

Application
The KRONE F/FTP 450/23 cable is designed for applications up to 450 MHz and provides transmission
performance meeting Category 6 specifications. This cables are low skew products, i.e. the difference in
propagation delay between the individual pairs is very low.
This is increasingly being requested for Gigabit Ethernet. The suitability of the cable for high-bit-rate
transmission systems ensures a high degree of future proofing. Additional features are the slim design and
low weight of the cables. Each pair is individually shielded (FTP).
The cable thus exceeds the requirements for EN 55022 Class B emission and EN 55024 immunity, enabling
networks to be built which are compliant with the standards on electromagnetic compatibility.














Characteristics
For up to 450 MHz
Excellent electrical characteristics
Each pair is individually shielded with foil (FTP)
Drain wire between foiled pairs
Halogenfree version LS0H (Low Smoke Zero Halogen)
Flame retardant to IEC 60332-1 and DIN VDE 0472, part 804, test type C
Non corrosive to IEC 60754-2
Low smoke to IEC 61034
Print: “KRONE PREMISNET CAT6 F/FTP LSZH FR 4P AWG23 SBC ISO/IEC 11801/ EN50173-1 IEC 60332-1
CAT C“ <week/year> CA KRONE 0637001315 <METERMARKER> + <Charge>

Design

Type designation

Category


Diameter
conductor
Number
of pairs

Fire rating
(MJ/m)
Halogen-
free
Tensile
strength for
installation [N]
Outside-ø
[mm]
Weight
[kg/km]
F/FTP 450/23 4P
LS0H-1

6

AWG 23

4

0,57

yes

145

7,4
58
* Cable description in compliance to ISO/IEC 11801 (2002) appendix E
Simplex (F/FTP 450/23 4P)

Cu-conductor AWG 23
Foam/Skin-PE-Insulation
Pair foil shield
2 wires stranded
foil
Sheath zero halogen, flame
retardant
Drain wire

page 2 of 2


Subject to availability and technical change without
notice

Copyright © 2003 MK


0637-0013-15_Krone-F/FTP 450_23_Kat.6_e.doc


KRONE F/FTP 450/23
F/FTP 450/23 FRNC Cat. 6 Cable

Electrical Characteristics at 20°C

Frequency in MHz
1 10 16 20 31,25 62,5 100 250 450
Attenuation in dB/ 100 m per Standard *
2,1 6,0 7,6 8,5 10,8 15,5 19,9 33,0 -

Typical data dB / 100 m
1,9 5,5 7,1 7,8 9,9 14,0 17,7 28,1 38,6
Near-end crosstalk loss in dB per Standard *
66,0 59,3 56,2 54,8 51,9 47,4 44,3 38,3 -
Typical data dB / 100 m
100,0 100,0 100,0 100,0 100,0 95,0 93,0 88,0 83,0
PSNEXT in dB/ 100 m per Standard *
64,0 57,3 54,2 52,8 49,9 45,4 42,3 36,3 -
Typical data dB / 100 m
98,0 98,0 98,0 98,0 98,0 93,0 91,0 86,0 80,0
ELFEXT in dB/ 100 m per Standard *
66,0 50,0 45,9 44,0 40,1 34,1 30,0 22,0 -
Typical data dB / 100 m
93,0 93,0 93,0 93,0 90,0 84,0 81,0 67,0 51,0
PSELFEXT in dB/ 100 m per Standard *
64,0 47,0 43,0 41,0 37,1 31,1 27,0 19,0 -
Typical data dB / 100 m
91,0 91,0 91,0 91,0 86,0 82,0 79,0 66,0 50,0
ACR in dB
98,1 94,5 92,9 92,2 90,1 72,0 75,3 59,9 44,4
*) Standard: Requirements on 100 m installed Category 6 cable for Class E cabling links (corresponds to pr EN 50288-5-1)

Max. loop resistance: 146 Ohm/km
Max. resistance difference: 1%
Insulation resistance: > 5000 MOhm x km
Impedance Zo at 0,064 MHz: 125 Ohm ± 20%
Impedance Zo at 1 - 100 MHz: 100 Ohm ± 15%
Impedance Zo at 101 - 250 MHz: 100 Ohm ± 18%
Transfer impedance: < 10 mOhm per meter bei 10 MHz
Longitudinal conversion loss dB/ref. Length = 1000 m: > 46 dB bei 64 kHz

Longitudinal conversion loss dB/ref. Length = 100 m: > 40 dB bei 1 MHz
Longitudinal conversion loss dB/ref. Length = 100 m: > 20 dB bei 100 MHz
Mutual capacity: 43 pF/m
Max. capacitance at 0,001 MHz: 1000 pF/km
Propagation velocity > 10 MHz (NVP*c): 0,79 c
Propagation delay ≥ 10 MHz: 4,2 ns/m
Skew: 4 ns/100m

Mechanical Characteristics
Wire insulation: Zero halogen foam/skin material
Sheath material: FRNC
Deployment area: Dry and damp rooms
Max. temperature range during installation: 0°C up to +50 °C
Max. operating temperature: -20 up to +60°C
Min. bend radius for single flexure: 40 mm
Min. bend radius during installation or pulling: 60 mm

Ordering Information
Type designation: F/FTP 450/23 4P FRNC
Delivery: 1000 m on one way drum
Ordering number 4 pairs: 7053 3 271-55

×