Multifunction Panel
Introduction and Applications ................................................................................................................................ 1
Modules
DS1 Interconnect Module: 4-Termination ........................................................................................................ 4
DS1 Interconnect Module: 8-Termination ........................................................................................................ 4
DS1 Monitor Module...................................................................................................................................... 4
DS1 Front Cross-Connect Module: 8-Termination ........................................................................................... 5
DS3 Interconnect Module ............................................................................................................................... 6
Individual DS3 Circuit ..................................................................................................................................... 6
Splice/Storage Fiber Plug-In Module: 6-Termination ........................................................................................ 7
Ethernet Category 5e Module ........................................................................................................................ 7
Module Ordering Information ................................................................................................................................ 8
Chassis Ordering Information
Swing-out Chassis ........................................................................................................................................ 10
Bulkhead Chassis.......................................................................................................................................... 10
QCP Wire Distribution Panels
Introduction and Applications .............................................................................................................................. 11
QCP Standard Panel Ordering Information
200/400-Pair Standard Panel – 19" EIA ........................................................................................................ 12
200/400-Pair Standard Panel – 23" WECO ................................................................................................... 12
300/600-Pair Standard Panel – 19" EIA ........................................................................................................ 13
300/600-Pair Standard Panel – 23" WECO ................................................................................................... 13
QCP DCS Panel Ordering Information .................................................................................................................. 14
QCP Accessories Ordering Information ................................................................................................................. 15


Impedance Matching Panel
Introduction and Applications .............................................................................................................................. 16
Impedance Matching Panel Ordering Information ................................................................................................ 18
Wired Assemblies
Introduction and Applications .............................................................................................................................. 19
Bantam Connectorized Jackfields
2-wire Jackfield ............................................................................................................................................ 21
4-wire Jackfield ............................................................................................................................................ 21
6-wire Jackfield ............................................................................................................................................ 21
Ordering Information ................................................................................................................................... 22
Voice Frequency Jackfield Ordering Information ................................................................................................... 23
Bantam Prewired Jackfields
2-wire Jackfield ............................................................................................................................................ 24
4-wire Jackfield ............................................................................................................................................ 24
6-wire Jackfield ............................................................................................................................................ 24
Ordering Information ................................................................................................................................... 25
Telephone Line Isolation Panel Ordering Information ............................................................................................ 27
Timing Jackfields Ordering Information ................................................................................................................ 28
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Connectorized Cables
Introduction ......................................................................................................................................................... 29
Category 2, 3 and 5 Cables Ordering Information ................................................................................................ 30
Terminal Blocks
Connectorized Terminal Blocks Ordering Information ........................................................................................... 31
Wire-wrap Terminal Blocks Ordering Information ................................................................................................. 32
Molded Terminal Blocks Ordering Information ...................................................................................................... 32
Terminal Blocks Accessories Ordering Information ................................................................................................ 33
Specifications

QCP Wire Distribution Panels ............................................................................................................................... 34
Impedance Matching Panel .................................................................................................................................. 36
Wired Assemblies................................................................................................................................................. 37
Connectorized Cables .......................................................................................................................................... 49
Connectorized Terminal Blocks ............................................................................................................................. 53
Index .................................................................................................................................................................. 56
Table of Contents
Termination and Access Products
Multifunction Panel ............................................................... 1
QCP Wire Distribution Panels .............................................. 11
Impedance Matching Panel ................................................. 16
Wired Assemblies ................................................................ 19
Connectorized Cables ......................................................... 29
Terminal Blocks .................................................................... 31
Specifications....................................................................... 34
Index ................................................................................... 56

1
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Introduction
The compact, modular universal multifunction chassis provides a point for nonintrusive monitoring,
testing and patching of circuits in PCS, wireless, utilities, CAP, CATV and customer premises applications.
The common chassis accepts three individual plug-in modules or one CSU and one plug-in module. This
concept eliminates the need to purchase separate panels for each application.
Multifunction Swing-Out Universal Chassis
(Loaded with a ber, DS1 and DS3 module)
Multifunction Swing-Out Chassis

(Loaded with one CSU and an 8-termination front
cross-connect DS1 module)
Features
• Compact, modular multifunction chassis provides a point for nonintrusive monitoring, testing and
patching of circuits
• Rack, wall or cabinet mounting
• Multiservice, multimedia
• Provides termination for: Voice, Data, Video, RF, Fiber, Ethernet, DS1/T1/FT, DS3/T3, Fuse and Alarm
Plug-in modules
• 4- and 8-termination DS1 interconnect modules available in wire-wrap or RJ IN/OUT connections
• 8-termination monitor module
• 8-termination DSX-1 cross-connect modules available in wire-wrap or RJ IN/OUT connections
• 1-circuit DS3 MPOP interconnect module with a modular design for growth up to three DS3 circuits
• Fiber connector module
• CSU mounting shelf
• 4-termination Cat 5e Ethernet module
2
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Applications
Customer Premise Applications
As end customers require more and more services, service providers (CAPs, CATV, utilities and RBOCs)
are taking a more active role in providing and maintaining the switch services at the customer premises
location. Figure 1 shows an integrated access concentrator at the customer premises location, with
the multifunction panel providing a demarcation point, as well as nonintrusive monitoring, testing and
patching, all within one integrated chassis.
Wireless Cell Site Applications
In today’s competitive wireless market, the ability to test, monitor and patch the RF signal prior

to sending the signal is essential in ensuring the downstream signal’s quality. Figure 2 illustrates
a typical base station with incoming signals connected to the multifunction panel before going
to the up/down converter.
MUX
DS3
T1
Voice
Data
SONET
Multifunction
Panel
Multifunction
Panel with
RF Module
Up/Down
Converter
Radio
Equipment
Demarcation
Multifunction
Panel
Multifunction
Panel
T1/E1
OR
T3/STS-1
Integrated Access
Concentrator
SERVICE PROVIDER CUSTOMER
Protector

Demarcation
Figure 2
Figure 1
3
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Applications
Wireless Multifunction Panel with DS1, DS3, Ethernet or Fiber Applications
The multifuction panel enables patching, termination and rearranging of circuits as traffic patterns
change and demands on the network grow. It connects network elements such as office repeaters,
digital switches, channel banks, digital loop carriers, multiplexers and digital loop switches.
SERVICE PROVIDER
Switch
M1/3
DSX-1
DSX-1
DSX-3
DSX-3
DS1 TEST
FOT
FDF
Multifunction
Panel
DSX
MTSO
Mobile Telephone Switching Office
Option 1: Mutifunction Panel with DSX
DS3

Module
M3/1 DSX
BTS
Cross-Connect w/ Loopback
N
E
T
W
O
R
K
Multifunction
Panel
FOT
DSX-3 DSX-3 DSX-1 DSX-1M3/1 BTS
BTS
Fiber Dist.
Panel
Fiber
Optic
Terminal
Cross-
Connect
Cross-
Connect
Base
Station
Base Station
Multi-
Plexer

Option 2: Mutifunction Panel
FDP
Figure 3
(Cellular/PCS Site Options)
4
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Modules
DS1 Interconnect Modules
4-Termination
8-Termination
DS1 Monitor Module
(Front View) (Rear View)
MFP-241000
(Front View) (Rear View)
(Front View) (Rear View)
MFP-242001
MFP-261001
4
5
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Modules
DS1 Front Cross-Connect Modules
8-Termination
(Front View) (Rear View)

MFP-231002
MFP-232001
MFP-232002
(Front View) (Rear View)
(Front View) (Rear View)
5
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Modules
DS3 Interconnect Module (Modular)
Individual DS3 Circuit
Mounts in module MFP-243002
(Front View) (Rear View)
MFP-243002
MFP-243001
(Front View) (Rear View)
6
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Modules
Splice/Storage Fiber Plug-In Module
(Front View)
(Rear View)
MFP-250002
7
Ethernet Category 5e Module

(Front View)
(Rear View)
MFP 242003-8W
6-Termination
8
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Modules
Additional congurations available.
Description Catalog Number
DS1 interconnect modules
For applications in which cross-connect functionality is not required
4-termination – supports 2 T1 circuits
Wire-wrap IN/OUT MFP-241000
RF48X IN/OUT MFP-242000
8-termination – supports 4 T1 circuits
1 50-pin connector IN/OUT, 4 RJ48X IN/OUT MFP-242001
4 wire-wrap IN/OUT, 4 RJ48X IN/OUT MFP-242002
14-termination – supports up to 7 T1 circuits
Wire-wrap IN/OUT MFP-231000
DS1 monitor module
8 circuit DS1 with monitor ports front IN/OUT RJ48X, Rear wire-wrap IN/OUT
MFP-261001
DS1 front cross-connect module
8-termination – supports 4 T1 circuits
Wire-wrap MFP-231002
RJ48X IN/OUT MFP-232001
RJ48C IN/OUT MFP-232005

4 wire-wrap IN/OUT
4 RJ48X IN/OUT
MFP-232002
DS3 interconnect module
One-position interconnect module with space for growth; total capacity of 3 DS3 circuits
Standard size coax jack access ports for testing or patching MFP-243002
Midsize coax jack access ports for testing or patching MFP-243006
Individual DS3 circuits
Standard size jack (mounts only in the MFP-243002 module) MFP-243001
Midsize (mini-WECO) coax jack (mounts only in the MFP-243006 module) MFP-243005
Ordering Information
9
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Modules
Description Catalog Number
Splice/storage fiber plug-in module
Singlemode SC adapters, no pigtails MFP-250004
Singlemode FC adapters, no pigtails MFP-250001
Singlemode ST
®
adapters, no pigtails MFP-250002
Multimode ST
®
adapters, no pigtails MFP-250003
Multimode SC adapters, no pigtails MFP-250005
6-position splice chips for fiber module
Heat shrink fusion FSC-HS

Bare fusion FSC-FT
Fiber cable clamp for incoming fiber MFP-251005
Fiber pigtails – 2 m (6.56') 900 µm
Singlemode FC FPT9-SPFC-S-2M
Singlemode ST
®
FPT9-SPST-S-2M
Singlemode SC FPT9-SPSC-S-2M
Multimode ST
®
with 62.5/125 µm FPT9-MST-B-2M
Ethernet category 5e module
RJ45-RJ45 Category 5e module MFP-242003-8W
Ordering Information
10
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Multifunction Panel
Chassis
The common chassis accepts three individual plug-in modules or one CSU and one plug-in module.
This concept eliminates the need to purchase separate chassis panels for each application.
Swing-Out Chassis
(MFP-100000)
Bulkhead Chassis
(MFP-110000)
Description Dimensions (HxWxD) Catalog Number
Swing-out chassis
3-position, swing-out chassis, front and rear access,
cable management for twisted pair, fiber and coax,

mounts in 19" (483 mm) or 23" (584 mm) EIA/WECO
racks or wall mount, adjustable flush, 25 mm (1"), 51
mm (2") or 127 mm (5") mounting.
89 mm x 439 mm x 267 mm
(3.5" x 17.3" x 10.5")
MFP-100000
Bulkhead chassis
3-positions 89 mm x 483 mm
(3.5" x 19")
MFP-110000
4-positions 89 mm x 584 mm
(3.5" x 23")
MFP-120000
Ordering Information
11
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Benefits
• Circuit traceability and simplicity in wiring.
• Greater accuracy resulting in less time required
during system installation, maintenance and
future updating since all contacts are color-
coded and all connections are made at the
front of the QCP bays
• Easy accommodation of traffic pattern
changes, since reconfiguring is done mostly
at the front of the QCP bays
• Simpler office layouts, since office equipment
can be installed where space is available.

The QCP system is then installed in the same
equipment rack for rack lineup and serves
as the intermediate distribution frame for
that equipment.
• Greater accuracy in office record-keeping,
since the panel labeling and color-coding
correspond to office record keeping formats
Features
• Color-coded wire termination contacts
• Fanning panels and wireways to keep all
wire parallel with minimum crossover
• Easy to read panel designations on
white panels
• Single-sided frame administration
• Various densities of wire termination are
available, with the maximum density
allowing up to 10,000 terminations on
an 8’ bay. Circuit identification and wire
routing are still manageable, even at these
maximum densities.
QCP Wire Distribution Panel
Introduction
Connectorized
or Non-Connectorized
Connectorized
Non-Connectorized
ADC’s quick connect panel (QCP) provides an
excellent means of connecting communications
circuits displaying easy circuit identification and
efficient wire management.

Wire Termination Contacts
This panel is available with either the insulation
displacement split cylinder contacts or wire-wrap
pins. The split cylinder contact provides for a
quick punch-down method of termination, which
is much faster than other methods requiring
patch cords, soldering, or wire-wrapping; yet
this contact termination is just as reliable as
wire-wrapping. The QCP insulation displacement
contact evenly distributes the holding force of
the cylinder, allowing many insertion/withdrawal
cycles and providing strain relief for the wire
resulting in a safe insulated termination. This
contact furnishes a gas tight connection, while
handling a variety of wire types.
Cable and Wire Routing
QCP Panels are provided with an arrangement of
fanning panels and wireways for easy wiring and
minimal wire congestion. A quadrant dressing
scheme is used to route wires to the side of the
bay and then up or down the vertical wireways,
either to other panels or to an express trough
to another bay. The backsides of the bays are
provided with brackets for easy routing and tying
of cables.
See pages 34-35 for specifications.
Individual QCP
Cylinder
Correct Strain
Relief for Wire

Stress Point Caused by
Incorrect Strain Relief
12
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
11
QCP Wire Distribution Panel
Standard Panel (200/400-Pair)
Description Catalog Number
19" EIA 1.75" rack spacing
Connectorized panels with rear 50-pin plug connector
400-pair wire-wrap W69F4-0825M
200-pair wire-wrap W39X2-0825M
Non-connectorized panels; 400-pair QCP punch down to QCP punch down Q69F4-0825X
23" WECO 2" rack spacing
Connectorized panels with rear 50-pin plug connector
400-pair wire-wrap W73F4-0825M
200-Pair QCP punch down Q43U2-0825M
200-pair wire-wrap W43X2-0825M
Non-connectorized panels
400-pair wire-wrap to wire-wrap W73F4-0825X
200-pair QCP punch down to QCP punch down Q43U2-0825X
200-pair wire-wrap to wire-wrap W43X2-0825X
Ordering Information
Custom panels are available. Minimum quantities apply.
13
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products

QCP Wire Distribution Panel
Standard Panel (300/600-Pair)
Description Catalog Number
19" EIA 1.75" rack spacing
Connectorized panels with rear 50-pin plug connector
300-pair QCP punch down Q39U2-1225M
300-pair wire-wrap W39X2-1225M
Non-connectorized panels
600-pair QCP punch down to wire-wrap QW89F4-1225X
300-pair wire-wrap to wire-wrap W39X2-1225X
23" WECO 2" rack spacing
Connectorized panels with rear 50-pin plug connector
300-pair QCP punch down Q43U2-1225M
300-pair wire-wrap W43X2-1225M
Non-connectorized panels
600-pair QCP punch down to wire-wrap W93F4-1225X
300-pair wire-wrap to wire-wrap W43X2-1225X
Ordering Information
Custom panels are available. Minimum quantities apply.
14
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
QCP Wire Distribution Panel
DCS Panel
Features and Benefits
• Convenient access point to monitor, test or
reconfigure circuits, eliminating work on the
DCS backplane and enabling troubleshooting
without uncabling.

• Preplanned, durable access point for
troubleshooting in a "direct connect"
application: a 1 for 1 circuit connection,
through the front and rear side of the same
termination contact by terminating network
element wires on the front and the DCS cable
on the back of the panel.
• In an interconnect application, allows rerouting
of circuits by terminating the DCS and network
element cables on the rear of the panel and
interconnecting them on the front.
• Available in 112- and 224-circuit sizes. The 112-
circuit panel is configured with pin groups of
4x28 and provides the easiest work access. The
224-circuit panel is configured with pin groups
of 8x28 and provides the highest termination
density, saving space.
• Excellent cable management with a variety of
filler panels, stand-off brackets, fanning panels,
fanning rings and dust covers.
• Available with shield pins as optional bonding
points. If used, the shield pins provide a means
for DCS/network element sheath continuity.
• Easily tested without clipping shortened
pigtails within the same cable sheath. The QCP
contacts are available for applications needing
frequent test access.
• Centralized termination, interconnection and
access to digital transmission lines between
the DCS and the network elements.

• An alternative to hardwiring digital
telecommunications equipment directly
to the DCS.
• A fallback option for interconnection of
network elements if the DCS fails.
Description Dimensions (HxW) Catalog Number
Connectorized panel wire-wrap
112-circuit 102 mm x 584 mm (4" x 23") QCP-YDXXA1
448-circuit 152 mm x 584 mm (6" x 23") QCP-YGXXA4
Ordering Information
Non-connectorized panels are available. Please contact ADC.
15
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
QCP Wire Distribution Panel
Accessories
Accessories Insulated Bridging Clips
Description Catalog Number
Tools
Impact tool QB-2
Replacement tip for QB-2 QB-2T
Manual tool (no spring loaded mechanism) Q115
Tool holder, bracket style Q150
QCP replacement kit includes instructions and the following:
– 25 red QCP housings
– 25 black QCP housings
– 25 white QCP housings
– 12 blue QCP housings
– 12 orange QCP housings

– 100 split cylinder contacts
QRK-25
Sleeving kit includes 100 pieces 63.5 mm (2.5"); PVC white SLVG-1
Ordering Information
16
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Impedance Matching Panel
75/120 Ohm Conversion
The 75/120 Ohm impedance-matching panel provides a solution for incompatible network interfaces
by creating an interchange between twisted pair and coaxial network elements. A balun converts the
unbalanced 75 Ohm impedance of a coaxial cable into the balanced 120 Ohm impedance of a twisted
pair. While ensuring quality and reliability, the panel allows continuous signal transmission through
otherwise incompatible interfaces. Frequently used in central office environments, this panel is often
deployed by system integrators in co-location facilities.
17
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products
Impedance Matching Panel
75/120 Ohm Conversion
Application
The impedance matching panel ensures digital signal reliability during the conversion from 75 Ohms
to 120 Ohms. This panel is ideal for central office and co-location facilities where original equipment
manufacturer (OEM) product interface incompatibilities frequently occur.
Network
Element A
Network
Element B

Twisted Pair
Cable
120 Ohms
Coax Cable
75 Ohms
Conversion Panel
Conversion Panel
Conversion Panel
Conversion Panel
Conversion Panel
Conversion Panel
Conversion Panel
Conversion Panel
Features and Benefits
Panels available with 8, 16, 24, or 32 circuits
Easily matches existing network equipment circuit counts
Multiple connector interface type and location options
Variety of configurations available to complement existing network designs
Preinstalled cable management bars
Reduces cable congestion and simplifies maintenance
Cable management rings with labeling
Ensures proper cable routing and circuit identification
Reversible mounting brackets
Each panel fits into 19" or 23-inch racks, or can be wall mounted
Support signal rates up to E1 (2.048 Mbps)
Impedance Matching Bay in Network
18
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products

Impedance Matching Panel
Balun Interface Location
F Front
Catalog Number
BAL - __ F __ __ - __
Balun Interface Type
A BNC
B 1.6/5.6
C Type 43*
D 1.0/2.3*
Number of Circuits
08 8 circuits
16 16 circuits
24 24 circuits
32 32 circuits
Twisted Pair Interface Location
F Front
R Rear
Twisted Pair Interface Type
A Wire-wrap
B Punch down (QCP)
C 64-pin receptacle connectors
D 64-pin plug connectors
E RJ45
See page 36 for panel dimensions and specifications
* Minimum order required for these connectors
19
www.adc.com • +1-952-938-8080 • 1-800-366-3891
3/08 • 102964AE
Termination and Access Products

Wired Assemblies
Introduction
In the central office, wired assembly jackfields,
inserted into VF circuits between different office
equipment, provide jack access for testing and
rerouting (patching) circuits.
Pioneered by ADC, these jackfields with bantam
jacks are available in a prewired, prewired
and connectorized, or connectorized only
configuration; and completely assembled in our
plant. No need for expensive wiring connections
in the field. ADC bantam jackfields are available
in virtually any circuit configuration required.
Included are 2-wire, 4-wire, and 6-wire circuits
for primary, secondary, intermediate, test and
out-of-service functions. Equally important, each
jackfield is checked, inspected and tested in
our plant.
See pages 37-48 for Specifications
JC6/48M

×