Tải bản đầy đủ (.pdf) (9 trang)

Tài liệu Notes on the use of hand-held test devices for installation of the KRONE Cat.6 KM8 products doc

Bạn đang xem bản rút gọn của tài liệu. Xem và tải ngay bản đầy đủ của tài liệu tại đây (211.53 KB, 9 trang )

23
Notes on the use of hand-held test devices for installation of the KRONE Cat.6 KM8 products Page 1 of 9
December 2001
Notes on the use of hand-held test devices for
installation of the KRONE Cat.6
K
K
M
M
8
8


p
p
r
r
o
o
d
d
u
u
c
c
t
t
s
s
§ FLUKE DSP 4000 / 4100 / 4300
§ MICROTEST OMNIScanner2™


§ Agilent WireScope 350
§ IDEAL LT8600LT
23
Notes on the use of hand-held test devices for installation of the KRONE Cat.6 KM8 products Page 2 of 9
December 2001
FLUKE DSP 4000 / 4100 / 4300
The FLUKE DSP 4X00 performs all tests required by
ISO/IEC 11801; DIN EN 50173, for example:
§ Cabling errors
§ NEXT
§ Power Sum NEXT
§ Return Loss
§ ELFEXT
§ Power Sum ELFEXT
§ Characteristic Impedance
§ Attenuation
§ ACR
§ Power Sum ACR
§ DC resistance
§ Length
§ Delay Skew
For further details please refer to the FLUKE documents.
Before you start a large-scale series of measurements go to the FLUKE homepage to see whether there
are current drivers, etc. for downloading:
/>The following releases are the most current ones
DSP 4000: Software Release 3.8
DSP 4100: Software Release 4.8
CableManager Software: Software V 4.6
Accessories:
§ Permanent Link Interface Adapter DSP LIA101S:

Includes:
§ 2 interface adapters
§ one set Personality module DSP-PM01
for KRONE KM8 (this is included in the standard delivery)
§ PM02 to PMxx are not relevant for measurement of the KRONE KM8
Note:
§ FLUKE DSP 4300 with new accessories (channel Cat.6 test head) is in preparation!
23
Notes on the use of hand-held test devices for installation of the KRONE Cat.6 KM8 products Page 3 of 9
December 2001
Cat 6/5e Channel Adapter DSP-LIA012S:
§ Contains two interface adapters for use with the DSP 4000 family
Basic Link Adapter:
§ DSP-LIA041S KRONE basic link adapter set for KRONE HighBand
§ This adapter cannot be used with the KM8
Required Settings:
§ Cable type
§ Category 5e, 6 or 7
§ UTP or STP
§ NVP´s (nominal velocity propagation) are in general already set as instrument default values;
otherwise see the table below
§ Measurement of shield influence: Yes / No (generally the choice is "No")
NVP settings for KRONE cables:
Cable Order No. NVP *
KRONE Cat 7 S-STP 7053 3 062-25 0.80
KRONE Cat 6 S-STP 7053 2 062-25 0.80
KRONE Cat 6 FTP 7053 2 021-04 0.68
KRONE Cat 6 UTP 7053 2 001-00 0.68
KRONE Cat 5e S-FTP 7053 1 052-25 0.66
KRONE Cat 5 FTP 7053 1 021-04 0.68

KRONE Cat 5 UTP 7053 1 001-00 0.68
KRONE C6 TrueNet UTP 7052 2 110-00 0.70
KRONE C5e TrueNet UTP 7052 1 110-00 0.70
* Note: The correct NVP setting is necessary; it has an influence on the determination of the cable length
by the instrument.
23
Notes on the use of hand-held test devices for installation of the KRONE Cat.6 KM8 products Page 4 of 9
December 2001
MICROTEST OMNIScanner2™
The MICROTEST OMNIScanner2™ performs all
tests required by ISO/IEC 11801, for example:
§ Cabling errors
§ NEXT
§ Power Sum NEXT
§ Return Loss
§ ELFEXT
§ Power Sum ELFEXT
§ Attenuation
§ ACR
§ Power Sum ACR
§ DC resistance
§ Length
§ Delay Skew
For further details please refer to the
MICROTEST documents
Before you start a large-scale series of measurements go to the MICROTEST homepage to see whether
there are current drivers, etc. for downloading:

The following releases are the most current ones:
OMNIScanner2™: OMNIScanner 5.11

Scanlink PC Software: Software V 7.0
Accessories:
§ Permanent Link Interface Adapter 8262-38:
Includes:
§ 2 interface adapters, suitable
§ for the KRONE KM8
23
Notes on the use of hand-held test devices for installation of the KRONE Cat.6 KM8 products Page 5 of 9
December 2001
Cat 6/5e Channel Adapter 8262-02:
Basic Link Adapter:
§ 8262-22: KRONE Basic Link Adapter Set for the KRONE HighBand
§ This adapter is not recommended for the KM8
Required settings:
§ Type of cable
§ Category 5e, 6 or 7
§ UTP or STP
§ NVP´s (nominal velocity propagation) are in general already set as instrument default values;
otherwise see the table below
NVP settings for KRONE cables:
Cable Order No. NVP *
KRONE Cat 7 S-STP 7053 3 062-25 0.80
KRONE Cat 6 S-STP 7053 2 062-25 0.80
KRONE Cat 6 FTP 7053 2 021-04 0.68
KRONE Cat 6 UTP 7053 2 001-00 0.68
KRONE Cat 5e S-FTP 7053 1 052-25 0.66
KRONE Cat 5 FTP 7053 1 021-04 0.68
KRONE Cat 5 UTP 7053 1 001-00 0.68
KRONE C6 TrueNet UTP 7052 2 110-00 0.70
KRONE C5e TrueNet UTP 7052 1 110-00 0.70

* Note: The correct NVP setting is necessary; it has an influence on the determination of the cable length