The Soneplex System
from ADC. The T1/E1
Service Delivery Experts
E1 Q
UAD
F
IBRE
L
OOP
C
ONVERTER

AND
U
NIVERSAL
M
OUNTING
C
HASSIS
21/02
449
E1 Quad Fibre Loop Converter
ADC has designed a family of Fibre Loop Converters (FLCs) that provide a cost-effective
alternative to deploying service over copper while avoiding the high capital investment
of primary multiplexers and Fibre optic terminals. This family includes products
designed for economical distribution of single or multiple 2.048 Mb signals.
The E1 Quad FLC multiplexes up to four 2.048 Mb signals for transport over two fibres
at typical distances of 72 Km (44 miles). The E1 QFLC system consists of a rack
mounted central exchange shelf and a wall or rack mounted customer premises shelf.
In contrast to fibre optic terminal systems (FOTS), which require a variety of modules to
start up operation, the E1 QFLC module is a stand-alone system and does not require


additional plug-in equipment.
The E1 QFLC was designed to be installed quickly. Installation is accomplished by
simply plugging a single module into the chassis and conducting basic checks. Exten-
sive, built-in self-test circuitry allows the E1 QFLC to isolate module failures and alert
maintenance personnel via standard office alarms.
The E1 QFLC supports 1+1 redundancy to protect against single point failures of both
optical facilities or electronic equipment. The E1 QFLC features two sets of bit-error
rate (BER) threshold select switches. These switches enable the technicians to select the
BER at which the module will: 1) declare a minor alarm to indicate that the BER has
exceeded an early warning level and 2) initiate protection switching in a system config-
ured in a protect mode. The BER threshold at which protection switching occurs may be
set according to the performance levels developed for access systems.
Utilizing remote loopback, end-to-end performance can be tested at the local end. By
pressing the remote alarm display switch, local front panel LEDs instantly display remote
module status. This is used to determine the cause of a remote alarm, and provide detail
necessary to determine whether or not to dispatch a technician to the far end.
Description
Features and Benefits
• Universal chassis concept supports optical hubs and is compatible with ADC’s entire FLC
family of O/E products
Mechanical housing can accommodate a wide variety of plug-in modules.
The universal chassis provides a broad platform from which new services can be delivered.
• Single module system
No need to inventory different working and protect modules, or different near and far-end modules.
One part number does it all, reducing investment in spare inventory and simplifying circuit provision-
ing and installation.
• Optional 1+1 redundancy
Protection against Fibre facility or equipment failures. Unprotected circuits can be upgraded later to
provide protection, thereby lowering the initial cost of installation.
• Dual selectable BER threshold setting

Provides selectable BER thresholds for protection switching and early warning minor alarm. Switching
and minor alarm levels can be set according to service requirements.
Features and
Benefits
31/02
449
E1 Quad Fibre Loop Converter
• Remote (far-end) alarms can be displayed locally
Simplifies trouble diagnostics and allows single-ended trouble shooting. This reduces field dispatches
and improves responsiveness to potential service interruption.
• Remote housekeeping alarm transport
Housekeeping alarm inputs provide monitoring of external equipment at the remote site, such as fire
and door alarms. Reduces investment in external alarm reporting systems.
• Individual E1 remote loopback capability
Allows single-ended testing of each E1 link to aid in trouble sectionalization.
• Automatic configuration matching
Simplifies installation by allowing a technician to provision only one module in a link. The remaining
local, remote and protection modules automatically provision themselves correctly.
• Optional wall mount battery back-up
Provides a minimum of eight hours back-up in the event of commercial power failure,
ensuring uninterrupted service. Available in 110 VAC or 220/240 VAC versions.
• Voice service channel
- One full duplex connection per QFLC module
- Eliminate separate voice facility during installation
• Laser cutoff safety
- Automatically shuts off laser upon cable disconnect
- Eliminates hazardous conditions
• High power laser transmitter
- Optical power budget at 30-33 dB
• Temperature hardened design

- Operating temperature range -40°C to 65°C
- Humidity range 5% to 95%, non-condensing
• Backward compatible with E1Q-B2LDFC E1 QLFC module
• Extended DC input voltage operating range -40 VDC to -72 VDC
• SNMP access through SNMP map system
- Central control for up to 192 E1 service delivery points
Features and
Benefits
41/02
449
E1 Quad Fibre Loop Converter
Applications
Providing fibre-based E1 services in urban applications requires low first cost installa-
tion and the capability to serve multiple customer locations. By placing the universal
rack mount shelf in the central exchange, up to eight different customer locations may
be served from a single platform. Service turn-up is fast, as only one plug-in part
number is needed, whether the service is 1:1 protected or unprotected.
KEY
–––––––––––––––––––––––––
DDF: Digital Distribution Frame
FDP: Fibre Distribution Panel
NID: Network Interface Device
QFLC: E1 Quad Fibre Loop Converter
Point to Multipoint
By installing the universal chassis at a central location, service providers can support
multiple customers in a variety of applications. Since the universal chassis supports all
FLC modules, modules can be mixed or matched depending on service requirements.
Described on the following pages are several applications which take advantage of the
flexibility in the Fibre Loop Converter system.
For more information on ADC products supporting service delivery in the local loop,

contact your nearest ADC sales office, listed on the back cover.
ADC product offering includes:
• Fibre cable management products
• Copper access and cross-connect products
• Premises multiplexers and circuit termination units
• Outside plant enclosures
Point to Multipoint
Building High Rise
Hut
REH Remote
Pedestal
REH
Remote
Pedestal
Central
Exchange
Hut
Business Park
Office Building
Office Building
Office Building
QFLC
N
I
D
N
I
D
QFLC
E1

Electrical
Central Exchange
DDF QFLC
Office Building
FDP
QFLC
N
I
D
QFLC
N
I
D
Point to
Multipoint
Central
Exchange
51/02
449
E1 Quad Fibre Loop Converter
Remote Pedestals
As fibre deployment extends into the loop, remote pedestals and cabinets are being fed
with fibre optic cable from a hut or central exhange. The QFLC is ideal for this applica-
tion, providing up to 8 E1s in a 4" chassis
KEY
–––––––––––––––––––––––––
DDF: Digital Distribution Frame
FDP: Fibre Distribution Panel
FOT: Fibre Optic Terminal
QFLC: E1 Quad Fibre Loop Converter

AS: Access Server
To Central
Exchange
Remote
Pedestal
Hut
1 - 240
Homes



E1
Electrical
QFLC
DDF
FDP
1 - 240
Homes



FOT
QFLC
AS
Remote
Pedestal
QFLC
AS
Hut
REH Remote

Pedestal
REH
Remote
Pedestal
Central
Exchange
Suburban
Business Parks
With the installation of an eight position rack mount shelf in a central exchange or
controlled environmental vault (CEV), a service provider can support multiple custom-
ers, each of which would have a wall or rack mount chassis on their premises. The E1
Quad Fibre Loop Converter allows the service provider to take advantage of any unused
Fibre already terminated at the building premises, thereby providing E1 service in the
most economical means possible. As the customer’s service requirements become more
critical, the service provider can install an additional E1 QFLC on each end of the link to
fully protect the system.
KEY
–––––––––––––––––––––––––
DDF: Digital Distribution Frame
FDP: Fibre Distribution Panel
FOT: Fibre Optic Terminal
QFLC: E1 Quad Fibre Loop Converter
Central
Exchange
Hut
Business Park
To Central
Exchange
Hut
E1

Electrical
QFLC
DDF
FDP
FOT
Factory
Headquarters
Warehouse
QFLC
QFLC
QFLC
61/02
449
E1 Quad Fibre Loop Converter
High Rise
Customer Premises
E1 Distribution
The Fibre Loop Converter family makes all-fibre
building risers an economical reality. Referenc-
ing the application drawing, you can see many
possible configurations that allow for fibre
drops on each floor. A primary or higher
level multiplexer can be located in the base-
ment of a high rise building and the E1s can
be deployed to the various floors of the build-
ing via E1 QFLC modules.
A series of wall mount chassis can be
mounted in the wiring closets of each floor.
In all situations, an AC power receptacle is
all that is required to power the units;

battery back-up is also available.
KEY
–––––––––––––––––––––––––
DDF: Digital Distribution Frame
FOT: Fibre Optic Terminal
MUX: Primary Multiplexer
QFLC: E1 Quad Fibre Loop Converter
Central
Exchange
Building
High Rise
Ordering
Information
Description
Eight Position Universal Rack Mount Chassis
19" or 23" (48.26 or 58.42 cm), -48 VDC, wire-wrap connector
Front access       FRM-FAW08B
Rear access
Two Position QFLC Chassis
Wire-wrap connector, front access
23" (58.42 cm) rack mounting     FRM-FAW02B
23" (58.42 cm) rack mounting (BNC)    FRM-FAW02D
Four Position Universal Wall Mount Chassis
RJ48 terminations
Wire-wrap terminations
110 VAC redundant power supplies
110 VAC with battery back-up
-48 VDC
Catalog Number
FRM-RAW08B

FWM-WWA04A
FWM-WWD04B
FWM-WWX04A
* See Accessories section for 220 VAC battery backup option.
Building High Rise
To Central
Exchange
QFLCDDF FDPFOT
M
U
X
QFLC
M
U
X
QFLC
E1
Electrical
To Central
Exchange
QFLCDDF FDPFOT
M
U
X
QFLC
M
U
X
QFLC
E1

Electrical
71/02
449
E1 Quad Fibre Loop Converter
Description Catalog Number
Ordering
Information
Modules
E1 Quad Fibre Loop Converter
Micro Processor Unit (MPU)
One per eight position universal chassis; mounts in MPU card slot
Accessories
Optional Equipment for Wall Mount Chassis
Swing out bracket for universal wall mount chassis
Mounting bracket to rack mount the four position wall mount chassis or
battery back-up system
110 VAC battery back-up system for use with FWM-WWX04A
220/240 VAC battery back-up system for use with FWM-WWX04A
Optional Equipment for Two Position Chassis
Used to vertically mount two position chassis
Bracket to mount two position QFLC chassis vertically in a cabinet FLC-HDW007
or on a wall
12 position bulkhead      BNC-BLK-12-WC
Balun converter, 120 Ω to 75 Ω     BA-1

E1Q-B2LDFC
FLC-A10MPU
FLC-HDW005
FLC-HDW006
FLC-AC/48V

FLC-AC/BB2
Specifications
ELECTRICAL
Input Frequency:
Input Level:
Output Frequency:
Interface Standard:
Output Signal:
Input/Output Impedance:
OPTICAL
Fibre Cable:
Operating Wavelength:
Optical Connector:
Transmit Device:
Receive Device:
2.048 Mbps ± 200 bps; up to four E1 lines; shaped line loss
relative to nominal DDF level
0 to -6.0 dB; up to four E1 lines; HDB3 format
2.048 Mbps ± 200 bps
Bipolar
Within CCITT G.703 template and level standards
120 Ω nominal at 1024 kHz
9/125 µm singlemode nominal
1305 nm ± 35 nm
FC
Laser
PIN Photodiode
Specifications continue on next page.
449 1/02 Revision © 2002 ADC Telecommunications, Inc. All Rights Reserved An Equal Opportunity Employe r
Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products,

ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our
headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously
enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents.
ADC Telecommunications, Inc.
P.O. Box 1101
Minneapolis, Minnesota 55440-1101
FAX: (612) 946-3292
From North America, Call Toll Free: 1-800-366-3891, Ext. 3223
Outside of North America: 612-938-8080
Home Page Address:
International Sales Offices: Belgium 32-2-712-6500 • United Kingdom 44-734-441955
• Montreal, Quebec (514) 677-9166 • Vancouver, BC (604) 270-1675 • Toronto, Ont.
(905) 629-3104 • Ottawa, Ont. (613) 723-2171 • Singapore 65-225-8228 •Venezuela 58-
2-286-1444 • Mexico City, Mexico 525-658-4519 • Buenos Aires, Argentina (541) 449-
2669 • Sao Paulo, Brasil 55-11-3040-0666 • Sydney, Australia 61-2-9975-1499 •
Melbourne, Australia 61-3-9585-3931 • Beijing, China 86-10-6500-7001 • Dusseldorf,
Germany 49-211-530-6550 • Seoul, Korea 82-2-333-8989
E1 Quad Fibre Loop Converter
OUTPUT POWER
Low Power Setting:
High Power Setting:
Receiver Dynamic Range:
Minimum Optical Budget:
Low Power Setting:
High Power Setting:
BER Threshold
For Protection Switching:
For Minor Alarm:
POWER
Supply Voltage:

Supply Current:
PHYSICAL
Dimensions (HxWxD):
Weight:
ENVIRONMENTAL
Temperature
Operating:
Storage:
Humidity
Operating:
Storage:
-5 to -8 dBm; -6.2 dBm typical
-3 to -6 dBm, -4.6 dBm typical
-4 to -39 dBm
30 dB; 32.8 dB typical
33 dB; 34.4 dB typical
8.5 x 10
-4
to 1 x 10
-10
user selectable threshold
1 x 10
-6
to 1 x 10
-10
user selectable threshold
-40 VDC to -72 VDC
275 mA typical @ -48V/300 mA maximum @ -48V
27.2 x 3.8 x 25.4 cm (10.7" x 1.5" x 10.0")
.64 kg (1 lb. 6.5 oz.)

-40°C to 65°C (-40°F to 149°F)
-55°C to 80°C (-67°F to 176°F)
5% to 95%, non-condensing
5% to 95%, non-condensing
Specifications

×