COLLEGE OF ENGINEERING TECHNOLOGY
DEPARTMENT OF AUTOMATION TECHNOLOGY
COURSE PROJECT
Course: Mechatronic system design (CN416)
Topic: “Smart medicine box for COVID-19 patients”
Lecturer: Ph.D Nguyễn Chánh Nghiệm
CONTENT REPORTS
1. Introduction
2. System overview
3. Result
4. Development orientation
INTRODUCTION
Identify opportunity
•
Designing self-driving cars to transport food for patients receiving isolation at home.
•
Contactless temperature meter.
•
Smart medicine box for COVID-19 patients (SMB)
•
Disinfection system for human transport vehicles.
•
Coronavirus detection system in enclosed space.
Why we choose "Smart medicine box for COVID-19 patients“ ?
INTRODUCTION
Why we choose "Smart medicine box for COVID-19 patients“ ?
•
•
•
Large market demand
Contributing to support the community to reverse the pandemic
Help elderly patients, patients in isolation at home, forgetful patients will take the medicine on
time, the right dosage and quickly healthy .
•
Project size is in line with team membership, budget and limited time
INTRODUCTION
Description: A medicine box, with a bell to remind the patient to take the medicine
on time, can be reminded through the application and message on
the smartphone .
H1. Outfit of SMB
SYSTEM OVERVIEW
Shape of product:
H2. The view of users when using SMB
H3. Inside view of SMB
SYSTEM OVERVIEW
The medicine container:
H4. The top view of part
H5. The bottom view of SMB
SYSTEM OVERVIEW
The schematic circuit:
H6. The schematic of MCU block
SYSTEM OVERVIEW
The schematic circuit:
H7. The schematic of other blocks
SYSTEM OVERVIEW
Testing circuit wiring
H8. The testing circuit wiring
SYSTEM OVERVIEW
The printed circuit board
H9. The printed circuit board
SYSTEM OVERVIEW
Actual testing circuit
H10. Actual testing circuit wiring
SYSTEM OVERVIEW
Video actual testing circuit
SYSTEM OVERVIEW
Users interface on smartphones
H11. Users interface on smartphones
RESULT
•
The team has completed the phone user interface and product drawings, and can
proceed to machining. Besides, the program code and actual circuit testing are still
making good progress.
•
Due to limited conditions and the difficulties of the COVID-19 epidemic, the team was
unable to complete the project as originally planned.
DEVELOPMENT ORIETATION
•
•
Can finish the product completely.
The product size can be optimized to be able to apply the product in many different
environments.
•
Can integrate other necessary functions for patients such as Heart rate measurement,
blood sugar measurement, emergency call when the user is in danger of health status.
THANKS FOR YOUR ATTENTION!