BIỆN PHÁP THI CÔNG CHỐNG THẤM/ WATERPROOFING METHOD STATEMENT
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________
NỘI DUNG
CONTENTS
BIỆN PHÁP & QUY TRÌNH THI CƠNG:
METHOD STATEMENT
1. NHÀ VỆ SINH:
TOILET:
+ SẢN PHẨM BETEC FLEX S150 (1.5 Kg/m²)
BETEC FLEX S150 (1.5 Kg/m²)
2. LÔ GIA, BAN CÔNG:
BALCONY:
+ SẢN PHẨM BETEC FLEX S150 (1.5 Kg/m²)
BETEC FLEX S150 (1.5 Kg/m²)
3. BIỆN PHÁP XỬ LÝ VÀ GIA CỐ LỖ TY ( TY CHẾT):
TREATMENT METHOD FOR TIE-ROD
+ SẢN PHẨM BETEC FLEX S150 (1.5 Kg/m²)
BETEC FLEX S150 (1.5 Kg/m²)
BIỆN PHÁP THI CÔNG CHỐNG THẤM/ WATERPROOFING METHOD STATEMENT
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________
PHẦN 1
NHÀ VỆ SINH
PART 1
TOILET
NHÀ VỆ SINH/ TOILET
(BETEC FLEX S150)
Lớp hồn thiện
Finishing layer
Lưới thủy tinh gia cố góc
CHI TIẾT A
DETAIL A
CHI TIẾT B
DETAIL B
LỚP CHỐNG THẤM: BETEC FLEX S150 (2 LỚP)
R.C SLAB
SÀN BÊ TÔNG CỐT THÉP
W.P LAYER - CORNER REINFORCEMENT: BETEC FLEX S150
LỚP CHỐNG THẤM - GIA CỐ GÓC: BETEC FLEX S150
CHAMFER
XỬ LÝ GĨC
BIỆN PHÁP THI CƠNG CHỐNG THẤM/ WATERPROOFING METHOD STATEMENT
Nhà vệ sinh
Toilet
Khu vực chống thấm
Waterproofing area
- BetecFlex S150
Sản phẩm
Product
_______________________________________________________________________________________________________________________________________________________________________
W.P LAYER: BETECFLEX S150 (2 COATS)
FIRBE GLASS - CORNER REINFORCEMENT
LƯỚI THỦY TINH - GIA CỐ GĨC
BIỆN PHÁP THI CƠNG CHỐNG THẤM NHÀ VỆ SINH
WATERPROOFING METHOD STATEMENT FOR TOILET
VỮA BẢO VỆ LỚP CHỐNG THẤM M75
Screeding protection M75
Lớp vữa bảo vệ chống thấm M75
Lớp hoàn thiện
Finishing layer
Screeding protection M75
WP layer: Betecflex S150
Lớp chống thấm: Betecflex S150
R.C. wall, slab
Tường, sàn BTCT
WP layer: Betecflex S150
Lưới thủy tinh gia cố góc
Firbe glass - corner reinforcement
WP layer - Reinforcement: Betecflex S150
Lớp chống thấm - gia cố góc: Betecflex S150
R.C. wall, slab
Tường, sàn BTCT
CHI TIẾT A
DETAIL A
CHI TIẾT B
DETAIL B
Lớp chống thấm: Betecflex S150
Lớp vữa bảo vệ chống thấm M75
Lớp hoàn thiện
Finishing layer
SCREEDING PROTECTION M75
FINISHING LAYER
Screeding protection M75
Lớp vữa bảo vệ chống thấm M75
WP layer: Betec flex S150
Lớp chống thấm: Betec flex S150
R.C. wall, slab
Định vị và gia cố cổ ống
thuộc bên nhà thầu M&E
Locate & reinforce pile
by M&E contractor
Tường, sàn BTCT
Grout
Vữa khơng co ngót
LỚP HỒN THIỆN
PU sealant
PU trám khe
Firbe glass - corner reinforcement
Lớp Betecflex S150 gia cố góc
WP layer: Betecflex S150
CHI TIẾT XỬ LÝ CỔ ỐNG
PIPE TREATMENT
236/6 Điện Biên Phủ, Phường 17, Quận Bình Thạnh, Tp.Hồ Chí Minh
Tel: 08.35142255 - 3.5142266 Fax: 08. 35142277
COTEC CONSTRUCTION JOINT STOCK Co.
CÔNG TY CP XÂY DỰNG COTEC
_____________________________________________________________________________________________________________________________________________________________________________________________________________________
≥10mm
300
QUY TRÌNH THI CƠNG
METHOD STATEMENT
I.CHUẨN BỊ BỀ MẶT / SURFACE PREPARATION:
1. Vệ sinh loại bỏ các tạp chất trên bề mặt như hồ, vữa, cát, bùn đất,… Dùng các phương pháp cơ
học để vệ sinh bề mặt.
All adhesion inhibiting substances such as dirt, cement, oil, hardeners, loose components, paint etc.
Must be removed by mechanical method
2. Các vị trí rỗ, tổ ong phải được trám trét lại bằng vữa latex
Repair honey comb concrete by latex motar.
3. Xử lý lỗ ty, cắt bỏ sắt lồi trên bề mặt bằng cách đục lỗ rộng 50x50mm sau đó trám bằng vữa latex
Cut back any protrusions and patching coin holes by chip to form a hole 50x50mm then fill the hole
with latex motar.
4. Xử lý các mạch ngừng, khe nứt trên bề mặt bằng cách đục vị trí mạch ngừng thành hình chữ V
Đục chữ V
Fill with Grout
Trám vữa khơng co ngót
Apply Waterproofing layer
Thi cơng lớp chống thấm
sau đó trám vữa khơng co ngót (nếu có)
Repair construction joints by chip of form V after fill non-shink grout (if any).
V-Shape hack
5. Xử lý, trám trét tại các vị trí góc, nách tường
Do chamfer at corner
6. Xử lý các cổ ống (nếu có)
Pipe treatment (if any)
7. Tạo ẩm trước khi thi công
Pre-water or damp the surface prior to application
BIỆN PHÁP THI CÔNG CHỐNG THẤM/ WATERPROOFING METHOD STATEMENT
_______________________________________________________________________________________________________________________________________________________________________
Nên trộn vật liệu bằng máy tốc độ chậm (600v/phút) có gắn lưỡi trộn thích hợp. Cho khoảng 75% thành
II.CÁCH TRỘN / MIXING:
phần A (lỏng) vào trong một thùng sạch, cho máy chạy và cho thành phần B (bột) vào từ từ. Trộn trong
vịng 3 phút cho tới khi có được hỗn hợp đồng nhất. Tiếp tục trộn, cho toàn bộ phần cịn lại của thành
phần A vào nếu thi cơng trên bề mặt ngang, hoặc chỉ một phần nếu thi công trên bề mặt đứng, và trộn tiếp
cho đều.
Pour Part A (liquid) into a pail, and pour Part B (powder) slowly into the pail and mix with a low speed
mixing machine or with paddle by hand. Mix until a slurry of even consistency is achieved (apx. 3minutes).
III.THI CÔNG / APPLICATION:
· Bước 1: Thi công quét một lớp dán lưới sợi thuỷ tinh tại các vị trí góc, nách tường.
Step 1: Apply one coat stick fibre glass at corner of wall - slab
· Bước 2: Thi công quét lớp thứ nhất (định mức 0.75 kg/m2) lên bề mặt sàn, tường đã được
tạo ẩm và gia cố.
Step 2: Apply first coat (consumption 0,75 kg/m2), over the pre-wetted wall, slab and reinforcement
· Bước 3: Sau khi lớp thứ nhất khô (từ 4-5 tiếng) tiến hành thi cơng tiếp lớp thứ 2 vng góc với lớp
thứ nhất (định mức 0.75 kg/m2)
Step 3: Apply second coat (consumption 0.75 kg/m2) after the first coat has dried (4-5 hours)
· Bước 4: Tiến hành thử nước trong vòng 24-48 giờ
Step 4: Do fluid test within 24-48 hours
Thi công các lớp chống thấm
· Bước 5: Cán/ tô vữa bảo vệ lớp chống thấm sau khi thi thử nước xong
Step 5: Screeding/ plastering for protection after fluid test
Vệ sinh chuẩn bị mặt bằng thi cơng
CƠNG TY CP XÂY DỰNG COTEC
_____________________________________________________________________________________________________________________________________________________________________________________________________________________
COTEC CONSTRUCTION JOINT STOCK Co.
236/6 Điện Biên Phủ, Phường 17, Quận Bình Thạnh, Tp.Hồ Chí Minh
Tel: 08.35142255 - 3.5142266 Fax: 08. 35142277
BIỆN PHÁP THI CÔNG CHỐNG THẤM/ WATERPROOFING METHOD STATEMENT
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________
PHẦN 2
PART 2
LÔ GIA, BAN CÔNG
BALCONY
LÔ GIA, BAN CÔNG/ BALCONY
(BETEC FLEX S150)
Xử lý góc
Chamfer
R.C SLAB
SÀN BÊ TƠNG CỐT THÉP
LỚP CHỐNG THẤM - GIA CỐ GÓC: BETEC FLEX S150
CHAMFER
XỬ LÝ GÓC
PVC WATERSTOP V-200
BĂNG CẢN NƯỚC PVC V-200
FIRBE GLASS - CORNER REINFORCEMENT
LƯỚI THỦY TINH GIA CỐ GÓC
W.P LAYER - CORNER REINFORCEMENT: BETEC FLEX S150
LỚP CHỐNG THẤM: BETEC FLEX S150 (2 LỚP)
W.P LAYER: BETECFLEX S150 (2 COATS)
VỮA BẢO VỆ LỚP CHỐNG THẤM M75
SCREEDING PROTECTION M75
FINISHING LAYER
LỚP HỒN THIỆN
Lớp hồn thiện
Finishing layer
Screeding protection M75
Lớp vữa bảo vệ chống thấm M75
Lớp hoàn thiện
Finishing layer
Screeding protection M75
WP layer: Betecflex S150
Lớp chống thấm: Betecflex S150
Lớp vữa bảo vệ chống thấm M75
WP layer: Betecflex S150
Lớp chống thấm: Betecflex S150
Lưới thủy tinh - gia cố góc
R.C. wall, slab
Tường, sàn BTCT
Firbe glass - corner reinforcement
WP layer - Reinforcement: Betecflex S150
CHI TIẾT B
DETAIL B
Lớp chống thấm - gia cố góc: Betecflex S150
R.C. wall, slab
Tường, sàn BTCT
CHI TIẾT A
DETAIL A
CÔNG TY CP XÂY DỰNG COTEC
_____________________________________________________________________________________________________________________________________________________________________________________________________________________
COTEC CONSTRUCTION JOINT STOCK Co.
236/6 Điện Biên Phủ, Phường 17, Quận Bình Thạnh, Tp.Hồ Chí Minh
Tel: 08.35142255 - 3.5142266 Fax: 08. 35142277
QUY TRÌNH THI CƠNG
METHOD STATEMENT
I. CƠNG TÁC CHUẨN BỊ TRƯỚC KHI THI CÔNG / PREPARATION BEFORE THE CONSTRUCTION:
Kiểm tra chất lượng bê tông trước khi thi công chống thấm bằng phương pháp test nước .
Check the quality of the concrete before applying waterproofing water test.
1. Vệ sinh loại bỏ các tạp chất trên bề mặt như hồ, vữa, cát, bùn đất,… Dùng các phương pháp
II.CHUẨN BỊ BỀ MẶT / SURFACE PREPARATION:
cơ học để vệ sinh bề mặt.
All adhesion inhibiting substances such as dirt, cement, oil, hardeners, loose components, paint etc. Must be
removed by mechanical method .
2. Các vị trí rỗ, tổ ong phải được trám trét lại bằng vữa latex
Repair honey comb concrete by latex motar.
4. Xử lý các mạch ngừng, khe nứt trên bề mặt bằng cách đục vị trí mạch ngừng thành hình chữ V sau đó trám
3. Xử lý lỗ ty, cắt bỏ sắt lồi trên bề mặt bằng cách đục lỗ rộng 50x50mm sau đó trám bằng vữa latex
Cut back any protrusions and patching coin holes by chip to form a hole 50x50mm then fill the hole with latex
motar.
Đục chữ V
Fill with Grout
Trám vữa không co ngót
Apply Waterproofing layer
Thi cơng lớp chống thấm
vữa khơng co ngót (nếu có)
Repair construction joints by chip of form V after fill non-shink grout (if any).
V-Shape hack
5. Xử lý, trám trét tại các vị trí góc, nách tường
Do chamfer at corner
6. Xử lý các cổ ống (nếu có)
Pipe treatment (if any)
7. Tạo ẩm trước khi thi công
Pre-water or damp the surface prior to application
Nên trộn vật liệu bằng máy có gắn lưỡi trộn thích hợp. Cho khoảng 75% thành phần A (lỏng) vào trong
III. CÁCH TRỘN / MIXING:
một thùng sạch, cho máy chạy và cho thành phần B (bột) vào từ từ. Trộn trong vịng 3 phút cho tới khi có
được hỗn hợp đồng nhất. Tiếp tục trộn, cho toàn bộ phần còn lại của thành phần A vào nếu thi công trên
bề mặt ngang, hoặc chỉ một phần nếu thi công trên bề mặt đứng, và trộn tiếp cho đều.
Pour Part A (liquid) into a pail, and pour Part B (powder) slowly into the pail and mix with a low speed
mixing machine or with paddle by hand. Mix until a slurry of even consistency is achieved (apx. 3minutes).
IV.THI CÔNG / APPLICATION:
· Bước 1: Thi công quét một lớp dán lưới sợi thuỷ tinh tại các vị trí góc, nách tường.
Step 1: Apply one coat stick fibre glass at corner of wall - slab
· Bước 2: Thi công quét lớp thứ nhất (định mức 0.75 kg/m2) lên bề mặt sàn, tường đã được tạo
ẩm và gia cố.
Step 2: Apply first coat (consumption 0.75 kg/m2), over the pre-wetted wall, slab and reinforcement
· Bước 3: Sau khi lớp thứ nhất khô (từ 4-5 tiếng) tiến hành thi công tiếp lớp thứ 2 vuông góc với
lớp thứ nhất (định mức 0.75kg/m2)
Step 3: Apply second coat (consumption 0.75 kg/m2) after the first coat has dried (4-5 hours)
· Bước 4: Tiến hành thử nước trong vòng 24-48 giờ
Step 4: Do fluid test within 24-48 hours
· Bước 5: Cán/ tô vữa bảo vệ lớp chống thấm sau khi thi thử nước xong
Step 5: Screeding/ plastering for protection after fluid test
CÔNG TY CP XÂY DỰNG COTEC
_____________________________________________________________________________________________________________________________________________________________________________________________________________________
COTEC CONSTRUCTION JOINT STOCK Co.
236/6 Điện Biên Phủ, Phường 17, Quận Bình Thạnh, Tp.Hồ Chí Minh
Tel: 08.35142255 - 3.5142266 Fax: 08. 35142277
PHẦN 3
BIỆN PHÁP XỬ LÝ LỖ TY
PART 3
TREATMENT METHOD FOR TIE-ROD
BIỆN PHÁP THI CÔNG CHỐNG THẤM/ WATERPROOFING METHOD STATEMENT
_______________________________________________________________________________________________________________________________________________________________________