B9000FXS : 60 – 300 kVA
B9600FXS : 400-800 kVA
Syed Hasan
Technical Product Executive
Ha Noi, Viet Nam, January 2012
Distributed CanBus
Loop load sharing and
paralleling
Triple Intelligence-
Tricore (Dual DSP + uC)
total digital control
Double IGBT power
electronics
Double conversion
on-line topology
High power
performance
Galvanic protection
B9000 Series UPS
High feature solutions for large
mission critical systems
3 phase input / 3 phase output
Capacity range:
60kVA, 80kVA,
100kVA, 120kVA,
160kVA, 200kVA,
250kVA, 300kVA.
B9000 UPS
3 phase input / 3 phase output
Capacity range:
400kVA


500kVA
600kVA
800kVA
B9600 UPS
UPS Topology & Technology Layout
B9000
B9000
UPS
UPS


s are
s are
DOUBLE-CONVERSION ON-LINE
DOUBLE-CONVERSION ON-LINE
the most reliable conguration
against any kind of power problem
(overvoltage, undervoltage, black-
out, brown-out, frequency variation
etc.)
According to the standards IEC EN 62040-3 the
classication is VFI (Voltage and Frequency
Independent)
IR E
IU G
IB Y
R E C T. IN V.
S SI
SS B
IR P

Type of UPS Topology
1.
1.
Offline / Standby UPS
Offline / Standby UPS
Type of UPS Topology
2.
2.
Line Interactive
Line Interactive
On-Line Double conversion
(B9000 & B9600)

DCO: Supplies clean continuously regulated
DCO: Supplies clean continuously regulated
power and guarantees the voltage and
power and guarantees the voltage and
frequency will be stabilize at nominal value
frequency will be stabilize at nominal value
independently from mains status
independently from mains status

On-Line: by contrast to off-line or line-
On-Line: by contrast to off-line or line-
interactive topology, the E2001.e inverter
interactive topology, the E2001.e inverter
is continuously supplying the load. This is
is continuously supplying the load. This is
an important aspect when even few
an important aspect when even few

milliseconds switchover could be critical.
milliseconds switchover could be critical.
B9000 : Dimension & Weight

Compare to
Compare to
other brand (300kVA):
other brand (300kVA):

Width = from 1600mm to 2280mm
Width = from 1600mm to 2280mm

Weight = from 2200kg to 2540kg
Weight = from 2200kg to 2540kg
Width 815 mm
Width 1200 mm
Depth 820 mm
Height 1670 mm
200-250-300 kVA
60-80-100-125-160 kVA
580-600-630-662-720 kg 870-1020-1200 kg
Height 1900 mm
Depth 860 mm
B9000 : Internal Layout
200-250-300 kVA
60-80-100-125-160 kVA
Front access
Communication ports
and service outlet
In/out/batt terminals

(dual input)
Auxiliary terminals

External manual bypass

Diesel generator

Auxiliary battery contact

Remote emergency power off (EPO)
Removable blowers
B9600 : Mechanical data
Modular layout
500-600 kVA
500-600 kVA
1200mm800mm
1200mm
1200mm 1200mm

Module maximum width = 1200mm for easy logistic
800 kVA
800 kVA
400 kVA
400 kVA
B9000 : Mechanical data
Overall dimensions & weights (with output isolation
transformer as standard)
Removable blowers
Internal Layout
Full front access

Communication ports
and service outlet
In/out/batt terminals
(dual input)
Internal Layout
Less disturbance to mains with 0.99 Input Power
factor

Low <3% input current harmonics

No need for oversizing cables,
transformers, breakers, generator set, etc.

No need for additional harmonic filters

Less malfunction of other equipment.
GenSet
10 kV, 50 Hz
400/230V, 50 Hz
Input Performance
Loads
PFC IGBT rectifier
Rectifier Technology
- Lower price
- Smaller size/footprint
- High THDi
- Need additional filter
- Higher price
- Bigger size/footprint

- Better THDi with
additional filter
- Moderate price
- Compact size / smaller footprint
- Much better THDi
- No need additional filter
Technical specifications

Rating: B9000: 60-80-100-125-160- 200-250-300
Rating: B9000: 60-80-100-125-160- 200-250-300
kVA
kVA


B9600: 400-500-600-800 kVA
B9600: 400-500-600-800 kVA




380 - 415 V (three-phase) -20% +15%
380 - 415 V (three-phase) -20% +15%
Freq. 50-60Hz
Freq. 50-60Hz

Double conversion On-line
Double conversion On-line

Input:
Input:

THDi < 3 % @100%load
THDi < 3 % @100%load
PF 0.99
PF 0.99

Output:
Output:
THDv < 1 %
THDv < 1 %
THDv < 5 % (non linear load)
THDv < 5 % (non linear load)
Dynamic Response
Dynamic Response
±
±
5% (100% load step)
5% (100% load step)
Overload 125% 10min, 150% 1min (Pn)
Overload 125% 10min, 150% 1min (Pn)
Short circuit 1.5In up to 2In
Short circuit 1.5In up to 2In

Battery:
Battery:
300 cells or 312 cells
300 cells or 312 cells
680V floating
680V floating

Inverter efficiency : up to 95 % (98% in ECO MODE)

Inverter efficiency : up to 95 % (98% in ECO MODE)

LCD display and LED mimic
LCD display and LED mimic

Wide connectivity options
Wide connectivity options
Single line diagram (B9000)
Automatic static
by-pass
Standard internal
Maintenance by-pass
Dual input: separated
input for rectifier and
emergency line
Galvanic
protection
Embedded backfeed
protection
Single line diagram (B9600)
Automatic static
by-pass
Optional
Maintenance
by-pass
Dual input: separated
input for rectifier and
emergency line
Galvanic
protection

Embedded backfeed
protection
Main Features

B9600 UPS is designed
B9600 UPS is designed
following low environmental impact criteria
following low environmental impact criteria

B9600 UPS is equipped with an advanced built-in
B9600 UPS is equipped with an advanced built-in
self diagnostic
self diagnostic
program indicating the problems and
program indicating the problems and
suggesting to the service people how to repair the
suggesting to the service people how to repair the
faults.
faults.

The high overall
The high overall
efficiency
efficiency
minimizes power
minimizes power
consumption.
consumption.




Eco-mode
Eco-mode
function. In this intelligent mode, mains
function. In this intelligent mode, mains
line is continuously being monitored in order to
line is continuously being monitored in order to
supply with high reliability the load.
supply with high reliability the load.
In Eco-mode, efficiency is considerably increased,
In Eco-mode, efficiency is considerably increased,
allowing high energy saving.
allowing high energy saving.
Efficiency vs Load %
0,84
0,86
0,88
0,9
0,92
0,94
0,96
25 50 75 100
Load %
Rectifier/charger features

Large input mains variations
Large input mains variations
are allowed without
are allowed without
affecting battery charge conditions.

affecting battery charge conditions.

AC/DC converter has
AC/DC converter has
built in battery charger function
built in battery charger function
.
.

Dynamic Charging Mode
Dynamic Charging Mode
, AC/DC converter is designed
, AC/DC converter is designed
to recharge batteries for extended time autonomies,
to recharge batteries for extended time autonomies,
with no increase in battery charging time.
with no increase in battery charging time.
all the rated
all the rated
power which is not drained from the inverter shall be
power which is not drained from the inverter shall be
available to the battery charger, by means of an
available to the battery charger, by means of an
automatic function.
automatic function.

Automatic and Manual Battery Test
Automatic and Manual Battery Test

Accurate Battery Management

Accurate Battery Management
according to the battery
according to the battery
manufacturers’ requirements.
manufacturers’ requirements.

Charge starts at a constant current , preventing detrimental
excess charging

float voltage level and boost charge (optional)

reduced residual current ripple

Protection against deep discharges

temperature compensation (optional) of battery charge
Rectifier/charger features
By means of the DCM (Dynamic Charging Mode)
By means of the DCM (Dynamic Charging Mode)
function, very long autonomy time batteries can be
function, very long autonomy time batteries can be
achieved without increasing total charging time. It is
achieved without increasing total charging time. It is
achieved further increasing the maximum battery
achieved further increasing the maximum battery
charge current, without the whole inverter power
charge current, without the whole inverter power
being drawn by the load.
being drawn by the load.



Dynamic Charging Mode
-
~
~
-
Mains Output
Bypass
Rectifier/charger features

Adjustable rectifier
Adjustable rectifier
walk-in
walk-in
time
time


5-30s
5-30s
(default 10sec) and
(default 10sec) and
hold-off
hold-off
time 1-300s
time 1-300s
(default 1sec) for full GenSet
(default 1sec) for full GenSet
compatibility
compatibility

Walk-in 5-30s
hold-off
1-300s


Inverter main features

Inverter design is based on a
Inverter design is based on a
full bridge 6-IGBT
full bridge 6-IGBT


matrix
matrix
,
,
fully digitally controlled
fully digitally controlled
, for high
, for high


output voltage stability and dynamic response.
output voltage stability and dynamic response.

Embedded galvanic protection
Embedded galvanic protection



prevents
prevents
direct feed-through of battery potential into critical
direct feed-through of battery potential into critical
loads and provides a very high rejection ratio of
loads and provides a very high rejection ratio of
power supply disturbances (spikes, surges etc
power supply disturbances (spikes, surges etc
.).
.).
ZigZag connection provides harmonic cancellation thus
reducing neutral conductor loading, and high output
voltage stability under severe unbalanced load conditions

×